SQUARE D

Reversing Contactor, TeSys Deca, 3P(3NO), AC-3, <=440V, 32A, 12V DC coil, screw clamp terminals

TeSys Deca reversing contactor

SQDLC2D32JL LC2D32JL 3389110545029
579.54 / EA
http://schema.org/OutOfStock
  • Depth: 101 mm
  • Warranty Length: 18 mth
TeSys Deca reversing contactor, 3 poles (3NO),for motor control applications 32A/440V,AC-3/3e 15kW@400V. Pre-wired power connections, with mechanical interlock,without electrical interlocking. It provides a low consumption 12V DC coil with transient suppressor module, 1NO+1NC built-in auxiliary contacts (NC mirror certified), connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures reliability and durability to standard applications. Compact (90mm width), with DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EN).
QTY
  • Product Description
  • Specifications
TeSys Deca reversing contactor, 3 poles (3NO),for motor control applications 32A/440V,AC-3/3e 15kW@400V. Pre-wired power connections, with mechanical interlock,without electrical interlocking. It provides a low consumption 12V DC coil with transient suppressor module, 1NO+1NC built-in auxiliary contacts (NC mirror certified), connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures reliability and durability to standard applications. Compact (90mm width), with DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EN).
  • Conformance Attributes
    • Product Certifications : RINA, GOST, CCC, UL, LROS (Lloyds register of shipping), CSA, DNV, GL, BV, CB
    • Standards : CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 60335-2-40:Annex JJ
  • Complementary Attributes
    • Control Circuit Type : DC low consumption, DC low consumption
    • Control Circuit Voltage Limits : 0.1...0.3 Uc (-40-70 °C):drop-out DC, 0.8...1.25 Uc (-40-60 °C):operational DC, 1...1.25 Uc (60-70 °C):operational DC
    • Irms Rated Making Capacity : 140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1, 550 A at 440 V for power circuit conforming to IEC 60947
    • Maximum Horse Power Rating : 2 hp at 115 V AC 60 Hz for 1 phase motors, 5 hp at 230/240 V AC 60 Hz for 1 phase motors, 7.5 hp at 200/208 V AC 60 Hz for 3 phase motors, 10 hp at 230/240 V AC 60 Hz for 3 phase motors, 20 hp at 460/480 V AC 60 Hz for 3 phase motors, 30 hp at 575/600 V AC 60 Hz for 3 phase motors
    • Icw Rated Short Time Withstand Current : 60 A 40 °C - 10 min for power circuit, 138 A 40 °C - 1 min for power circuit, 260 A 40 °C - 10 s for power circuit, 430 A 40 °C - 1 s for power circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit
    • Ie Rated Operational Current : 32 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 50 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
    • Uc Control Circuit Voltage : 12 V, 12 V DC
    • Ue Rated Operational Voltage : power circuit <= 690 V AC 25...400 Hz, power circuit <= 300 V DC
    • Ui Rated Insulation Voltage : signalling circuit 600 V CSA, signalling circuit 600 V UL, power circuit 690 V IEC 60947-4-1, power circuit 600 V CSA, power circuit 600 V UL, signalling circuit 690 V IEC 60947-1
    • Maximum Motor Phase Current : 32 A
    • Maximum Operating Rate : 3600 cyc/h 60 °C
    • Minimum Switching Current : 5 mA for signalling circuit
    • Minimum Switching Voltage : 17 V for signalling circuit
    • Rated Breaking Capacity : 550 A at 440 V for power circuit conforming to IEC 60947
    • Uimp Rated Impulse Withstand Voltage : 6 kV IEC 60947
  • Important Information Attributes
    • Persona Type Ids : EU, LC, OM, OM8, PB, SI
    • Persona Type Names : End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, System Integrator
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Associated Fuse Rating : 10 A gG for signalling circuit conforming to IEC 60947-5-1, 63 A gG at <= 690 V coordination type 1 for power circuit, 63 A gG at <= 690 V coordination type 2 for power circuit
    • Contactor Application : resistive load, motor control
    • Electrical Durability : 1.65 Mcycles 32 A AC-3 <= 440 V, 1.4 Mcycles 50 A AC-1 <= 440 V
    • Insulation Resistance : > 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit
    • Mechanical Robustness : vibrations contactor open2 Gn, 5...300 Hz, vibrations contactor closed4 Gn, 5...300 Hz, shocks contactor closed15 Gn for 11 ms, shocks contactor open8 Gn for 11 ms
    • Motor Power Kw : 7.5 kW at 220...230 V AC 50 Hz, 15 kW at 380...400 V AC 50 Hz, 15 kW at 415...440 V AC 50 Hz, 18.5 kW at 500 V AC 50 Hz, 18.5 kW at 660...690 V AC 50 Hz
    • Mounting Support : rail, plate
    • Non Overlap Time : 1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact
    • Operating Time : 65.45...88.55 ms closing, 20...30 ms opening
    • Power Dissipation Per Pole : 2 W AC-3, 5 W AC-1
    • Safety Reliability Level : B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
    • Tightening Torque : power circuit 2.5 N.m screw clamp terminals Philips No 2, control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm, control circuit 1.7 N.m screw clamp terminals Philips No 2, power circuit 2.5 N.m screw clamp terminals flat Ø 6 mm
    • Utilisation Category : AC-3, AC-1
    • Connections Terminals : control circuit screw clamp terminals 2 1-2.5 mm²flexible with cable end, control circuit screw clamp terminals 2 1-4 mm²solid, power circuit screw clamp terminals 2 2.5-10 mm²flexible without cable end, power circuit screw clamp terminals 1 1-10 mm²flexible with cable end, power circuit screw clamp terminals 1 1.5-10 mm²solid, power circuit screw clamp terminals 2 2.5-10 mm²solid, control circuit screw clamp terminals 1 1-4 mm²flexible without cable end, control circuit screw clamp terminals 2 1-4 mm²flexible without cable end, control circuit screw clamp terminals 1 1-4 mm²flexible with cable end, control circuit screw clamp terminals 1 1-4 mm²solid, power circuit screw clamp terminals 1 2.5-10 mm²flexible without cable end, power circuit screw clamp terminals 2 1.5-6 mm²flexible with cable end
    • Icw Rated Short Time Withstand Current : 60 A 40 °C - 10 min for power circuit, 138 A 40 °C - 1 min for power circuit, 260 A 40 °C - 10 s for power circuit, 430 A 40 °C - 1 s for power circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit
    • Ie Rated Operational Current : 32 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 50 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
    • Ith Conventional Free Air Thermal Current : 10 A (at 60 °C) for signalling circuit, 50 A (at 60 °C) for power circuit
    • Carbon Footprint Of The Distribution Phase A4 : 0.3407466641464256, 0.3 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 3 kg CO2 eq., 2.9858129163967595
    • Carbon Footprint Of The Installation Phase A5 : 0.09435853552632247, 0.1 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 6 kg CO2 eq., 6.165334274865126
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 46 kg CO2 eq., 45.65318918918919
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-11-13
    • Global Commercial Status : Commercialised
    • Return Indicator : Y
    • Stocking Flag : Y
    • Stock Policy : 1
    • Device Type : LV equipment - LV contactor
    • Serviceability : No
    • Traceability : No
    • Field Service Division : PPIBS
    • Average Life Duration : 20 year(s)
    • Legacy Weee Scope : In
    • Weee Product Category : 5
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI1102030EN
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : Yes
    • Rohs Eur Status : Compliant By Exemption
    • Rohs Eur Conformity Date : 1929
    • Rohs Eur Full Compliance Status : Compliant By Exemption
    • China Rohs In Scope : No
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Tier Id : 1
    • Tier : 1
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Product Kit Identifier : N
    • Average Impedance : 2 mOhm - Ith 50 A 50 Hz for power circuit
    • Coil Technology : built-in bidirectional peak limiting diode suppressor
    • Compatibility Code : LC2D
    • Contact Compatibility : M5
    • Device Short Name : LC2D
    • Energy Efficiency Optimized : False
    • Fire Resistance : 850 °C IEC 60695-2-1
    • Flame Retardance : V1 conforming to UL 94
    • Hold In Power Consumption In W : 2.4-2.4 W 20 °C
    • Inrush Power In W : 2.4-2.4 W 20 °C)
    • Interlocking Type : mechanical
    • Mechanical Durability : 30 Mcycles
    • Overvoltage Category : III
    • Pole Contact Composition : 3 NO
    • Poles Description : 3P
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Name : TeSys D
    • Product Or Component Type : reversing contactor
    • Protective Treatment : TH IEC 60068-2-30
    • Range : TeSys
    • Range Of Product : TeSys D
    • Returnability : Yes
    • Signalling Circuit Frequency : 25...400 Hz
    • Software Version : v5.9.4
    • Sustainable Packaging : Yes
    • Time Constant : 40 ms
    • Total Lifecycle Carbon Footprint : 55 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Rated Thermal Current Ith : 50 A
    • Warranty In Months : 18
    • Control Circuit Voltage : 12 V
    • Inf Motor Phase Current : 32 A
    • Pep Code : ENVPEP110230EN
    • Database Version : 2022-01
    • Pep Verification Date : 2025-08-05
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed2-2016 03 29
    • Type Of Verification For The Pep : Independent external review
    • Data Source : extrapolated product
    • Functional Unit Description : Switch on and off during 20 years electrical power supply of a downstream installation with an electrical and/or mechanical control.The functional unit is characterized by a type 3NO, a control circuit voltage 24V DC,a power circuit voltage 690V and a rated operational current 9A.
    • Functional Unit Quantity : 1
    • Functional Unit Unit : unit
    • Product Weight In G2 : 1217
    • Reference Lifetime In Y2 : 20
    • Energy Consumption On Product Lifetime In Kwh : 683.28
    • Energy Model Manufacturing A1 A3 2 : Electricity Mix; Production mix; Low voltage; FR
    • Energy Model Installation A5 2 : Electricity Mix; Production mix; Low voltage; FR
    • Energy Model Use B6 2 : Electricity Mix; Production mix; Low voltage; FR
    • Energy Model End Of Life C1 C4 2 : Electricity Mix; Production mix; Low voltage; FR
    • Recyclability Potential In 2 : 75
    • Offer Owner Code : 190788
    • Height Nominal : 85 mm
    • Width Nominal : 90 mm
  • Environment Attributes Main
    • China Rohs Regulation : Product out of China RoHS scope , Product out of China RoHS scope. Substance declaration for your information.
    • Ambient Air Temperature For Operation : -40-60 °C, -40-60 °C, 60-70 °C with derating
    • Climatic Withstand : IACS E10, IEC 60947-1 Annex Q category D
    • Take Back : Nej
    • Recycled Metal Content At Cr Level : 0 %
    • Mercury Free : Yes
    • Carbon Footprint : 55.239441580123824
    • Ambient Air Temperature For Storage : -60-80 °C
    • Circularity Profile : ENVEOLI1102030EN
    • Environmental Disclosure : ENVPEP110230EN
    • Eu Rohs Directive : Compliant By Exemption
    • Ip Degree Of Protection : IP20 front face IEC 60529
    • Operating Altitude : 0...9842.52 ft (0...3000 m)
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP110230EN
    • Pep Verification Date : 2025-08-05
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed2-2016 03 29
    • Type Of Verification For The Pep : Independent external review
  • General Attributes
    • Product Or Component Type : reversing contactor
    • Range Of Product : TeSys D
  • ETIM
    • ETIM 8 : EC000010
    • ETIM 9 : EC000010
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Specifications
    • Depth : 101 mm
  • Overview Attributes
    • Device Presentation : preassembled with reversing power busbar