The purpose of ground-fault protection is to measure the ground leakage current of an electrical installation, or part of an installation, and interrupt the power supply if the ground-fault current becomes dangerous to property. Vigirex™ ground-fault relays, with associated sensors (current transformers), measure the leakage current in an electrical installation to detect levels that may be damaging. When used for protection, they cause an associated circuit breaker or switch to interrupt the supply of power to the protected system. They may also be used for monitoring only, with output to an alarm. The Vigirex product line can be used with loads up to 3200A. It includes fixed sensitivities from 30 mA to 1 A and adjustable sensitivities up to 30 A, providing a solution that offers both flexibility and performance. The responsiveness of the Vigirex relay is determined from a combination of their sensitivity (measured in milliamperes or amps) and their time delays (duration that the threshold of ground-fault is exceeded). These can range from instantaneous (no intentional delay) to 4.5 seconds. The shortest delay will provide the greatest protection, while the longest will minimize nuisance tripping. The range of time delays is also helpful when providing a coordinated ground-fault protection scheme. This Vigirex, time delay switch is DIN rail mounted. This product has a control current voltage of 240 VAC. This product complys to UL standards.
QTY
  • Product Description
  • Features
  • Specifications
The purpose of ground-fault protection is to measure the ground leakage current of an electrical installation, or part of an installation, and interrupt the power supply if the ground-fault current becomes dangerous to property. Vigirex™ ground-fault relays, with associated sensors (current transformers), measure the leakage current in an electrical installation to detect levels that may be damaging. When used for protection, they cause an associated circuit breaker or switch to interrupt the supply of power to the protected system. They may also be used for monitoring only, with output to an alarm. The Vigirex product line can be used with loads up to 3200A. It includes fixed sensitivities from 30 mA to 1 A and adjustable sensitivities up to 30 A, providing a solution that offers both flexibility and performance. The responsiveness of the Vigirex relay is determined from a combination of their sensitivity (measured in milliamperes or amps) and their time delays (duration that the threshold of ground-fault is exceeded). These can range from instantaneous (no intentional delay) to 4.5 seconds. The shortest delay will provide the greatest protection, while the longest will minimize nuisance tripping. The range of time delays is also helpful when providing a coordinated ground-fault protection scheme. This Vigirex, time delay switch is DIN rail mounted. This product has a control current voltage of 240 VAC. This product complys to UL standards.
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Physical Attributes
    • Wire Stripping Length : auxiliary power supply: 7 mm, fault: 7 mm, relay test and fault reset: 7 mm, sensor: 7 mm, voltage presence: 7 mm
  • Complementary Attributes
    • Network Rated Voltage : 1000-1000 V - AC 50/60 Hz maximum), 1000-1000 V - AC 400 Hz maximum)
    • Minimum Load : 10 mA 12 V
  • Important Information Attributes
    • Persona Type Ids : LC, PB
    • Persona Type Names : Contractor, Panel Builder
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Earthing System : TT, TN-S
    • Electromagnetic Compatibility : conducted and radiated emissionsB CISPR 11, conducted radio-frequency immunity test3 IEC 61000-4-6, electrostatic discharge immunity test4 IEC 61000-4-2high-energy conducted susceptibility4 IEC 61000-4-5low-energy conducted susceptibility4 IEC 61000-4-4radiated susceptibility3 IEC 61000-4-3
    • Mechanical Robustness : fire resistance IEC 60695-2-1IK protection 2 joulesIK07 EN 50102, vibrations 13.2...100 Hz0.7 gvibrations 2...13.2 Hz+/- 1 mm
    • Monitoring : electronics continuous), power supply continuous), relay/sensor link continuous)
    • Test Function : local, remote test
    • Tightening Torque : auxiliary power supply: 0.6-0.6 N.m, fault: 0.6-0.6 N.m, relay test and fault reset: 0.6-0.6 N.m, sensor: 0.6-0.6 N.m, voltage presence: 0.6-0.6 N.m
    • Certificate Agency : EN/IEC 60947-2 Annex M, EN/IEC 60755, UL 1053, CAN/CSA C22.2 No. 144
    • Connections - Terminals : fault terminal block 0.2-2.5 mm² rigid 24 AWG...12 AWG, fault terminal block 0.25-2.5 mm² flexible with ferrule 24 AWG...12 AWGrelay test and fault reset terminal block 0.2-2.5 mm² rigid 24 AWG...12 AWG, relay test and fault reset terminal block 0.25-2.5 mm² flexible with ferrule 24 AWG...12 AWGsensor terminal block 0.2-2.5 mm² rigid 24 AWG...12 AWG, sensor terminal block 0.25-2.5 mm² flexible with ferrule 24 AWG...12 AWGvoltage presence terminal block 0.2-2.5 mm² rigid 24 AWG...12 AWG, voltage presence terminal block 0.25-2.5 mm² flexible with ferrule 24 AWG...12 AWGauxiliary power supply terminal block 0.2-2.5 mm² flexible 24 AWG...12 AWG, auxiliary power supply terminal block 0.2-2.5 mm² rigid 24 AWG...12 AWGauxiliary power supply terminal block 0.25-2.5 mm² flexible with ferrule 24 AWG...12 AWG, fault terminal block 0.2-2.5 mm² flexible 24 AWG...12 AWG, relay test and fault reset terminal block 0.2-2.5 mm² flexible 24 AWG...12 AWG, sensor terminal block 0.2-2.5 mm² flexible 24 AWG...12 AWG, voltage presence terminal block 0.2-2.5 mm² flexible 24 AWG...12 AWG
    • Carbon Footprint Of The Distribution Phase [A4] : 0.03143779518914882, 0 kg CO2 eq.
    • Carbon Footprint Of The End-of-life Phase [C1 To C4] : 0.6 kg CO2 eq., 0.5867570085226158
    • Carbon Footprint Of The Installation Phase [A5] : 0.05244381884677071, 0.1 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase [A1 To A3] : 2 kg CO2 eq., 2.014500246460156
    • Carbon Footprint Of The Use Phase [B2, B3, B4, B6] : 46 kg CO2 eq., 46.31700000000001
    • Local Data Status : Publishable
    • Local Publishable Date : 2026-05-16
    • Return Indicator : N
    • Stocking Flag : Y
    • Stock Policy : 2
    • Device Type : Relay, Control & Measurement - Protection relay
    • Serviceability : Yes
    • Traceability : Yes
    • Field Service Division : PPIBS
    • Average Life Duration : 15 year(s)
    • Weee Applicability : Finished product
    • Weee Scope : In
    • Weee Product Category : 5
    • Scope Perimeter : Outside of Europe
    • Eoli Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI2310023EN
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : Yes
    • Rohs Eur Status : Compliant By Exemption
    • Rohs Eur Conformity Date : 1902
    • Rohs Eur Full Compliance Status : Compliant By Exemption
    • China Rohs In Scope : No
    • China Rohs Label : 7
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : No
    • Product Contributes To Saved And Avoided Emissions : No
    • Tier Id : 1
    • Tier : 1
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Product Kit Identifier : N
    • Compatibility Code : RH99P
    • Device Short Name : RH99P
    • Earth Leakage Current : 0.03-30 A
    • Electrical Shock Protection Class : class II
    • Energy Efficiency Optimized : False
    • Mounting Support : front panel
    • Overvoltage Category : IV
    • Power Consumption In Va : 4 VA
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Or Component Type : monitoring relay
    • Range : Vigirex
    • Range Of Product : Vigirex
    • Relay Application : monitoring relay
    • Returnability : No
    • Software Version : v5.9.4
    • Sustainable Packaging : No
    • Tamperproof Of Settings : protected by sealable cover
    • Threshold Setting : 0.03...30 A alarm
    • Total Lifecycle Carbon Footprint : 49 kg CO2 eq.
    • Type Of Measurement : earth fault current internal measurement 80...100 %
    • Type Of Setting : selector
    • Pep Code : ENVPEP2310023EN
    • Database Version : 2022-01
    • Pep Verification Date : 2023-12-05
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed2-2016 03 29
    • Type Of Verification For The Pep : Independent external review
    • Data Source : extrapolated product
    • Functional-unit Description : Protect during 10 years people and premises at risk of fire or explosion with assigned voltage 220-240V by detecting and measuring the earth leakage current sensitivity is selectable with 9 thresholds from 30 mA to 30 A.
    • Functional-unit Quantity : 1
    • Functional-unit Unit : Unit
    • Reference Lifetime, In Y : 10
    • Energy Model - Manufacturing [A1-a3] : Electricity Mix; Production mix; Low voltage; FR
    • Energy Model - Installation [A5] : Electricity Mix; Production mix; Low voltage; UE-27
    • Energy Model - Use [B6] : Electricity Mix; Production mix; Low voltage; UE-27
    • Energy Model - End Of Life [C1-c4] : Electricity Mix; Production mix; Low voltage; UE-27
    • Recyclability Potential, In % : 27
    • Height Nominal : 72 mm
    • Width Nominal : 72 mm
    • [Ithe] Conventional Enclosed Thermal Current : 8 A
    • [Uimp] Rated Impulse Withstand Voltage : 8 kV
    • [Us] Rated Supply Voltage : 240 V AC 50/60 Hz 70...110 %
    • Cut-out Dimensions : 68 x 68 mm
    • Residual Earth-leakage Time Delay Adjustment Type : instantaneous for 0.03-0.03 Aadjustable 9 settings 0-4.5 s for 0.03-30 A
    • Residual Earth-leakage Sensitity Adjustment Type : adjustable 9 settings
    • Halogen-free Status : Product contains halogen above thresholds
    • Nbr. Of Units In Pkg. : 1
    • Package Weight(Lbs) : 240.404 g
    • Take-back : No
    • Warranty (In Months) : 18
    • Customs Code : 8536490075
  • Environment Attributes Main
    • China Rohs Regulation : Product out of China RoHS scope , Product out of China RoHS scope. Substance declaration for your information.
    • Ambient Air Temperature For Operation : -35-70 °C, -35-70 °C
    • Ambient Air Temperature For Storage : -55-85 °C, -55-85 °C
    • Take Back : No
    • Halogene Performance : Product contains halogen above thresholds
    • Recycled Metal Content At Cr Level : 0 %
    • Mercury Free : Yes
    • Carbon Footprint : 49.0021388690187
    • Circularity Profile : ENVEOLI2310023EN
    • Environmental Disclosure : ENVPEP2310023EN
    • Eu Rohs Directive : Compliant By Exemption
    • Halogen Content Performance : Product contains halogen above thresholds
    • Ip Degree Of Protection : IP40 on front face: conforming to EN/IEC 60529IP30 on side parts: conforming to EN/IEC 60529IP20 on connection terminals: conforming to EN/IEC 60529
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : No
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Relative Humidity : 95-95 % 55-55 °C
    • Pep Code : ENVPEP2310023EN
    • Pep Verification Date : 2023-12-05
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed2-2016 03 29
    • Type Of Verification For The Pep : Independent external review
  • General Attributes
    • Product Or Component Type : monitoring relay
    • Range Of Product : Vigirex
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Specifications
    • Country of Origin : France, United States