Residual current protection relay, VigiPacT RH10P, 300mA, 220/240VAC 50/60Hz, front panel mounting

RESIDUAL CURRENT PROTECTION RE

SQD56235 56235 3303430562351
1577.23 / EA
http://schema.org/OutOfStock
  • Country of Origin: France
  • Depth: 78 mm
  • Warranty Length: 18 mth
VigiPacT RH10P is a front panel mounting residual current protection relay. It protects against people direct or indirect contact, property fire hazards and motors. It measures the earth leakage current in an electrical installation via its associated toroid. It trips the associated circuit breaker when the set residual operation current is overrun. The operational supply voltage is 220/240VAC 50/60Hz. It is a type A earth-leakage protection class. The current sensitivity (IDn) is fixed to 300mA. The time delay (Dt) is instantaneous. It requires a local manual reset after a fault clearance. The monitored distribution system voltage is up to 1000VAC 50/60/400Hz. It is installed on a front panel switchboard and the protection degree is IP40. It must be associated with a compatible Schneider Electric type A toroid or rectangular sensor.
QTY
  • Product Description
  • Features
  • Specifications
VigiPacT RH10P is a front panel mounting residual current protection relay. It protects against people direct or indirect contact, property fire hazards and motors. It measures the earth leakage current in an electrical installation via its associated toroid. It trips the associated circuit breaker when the set residual operation current is overrun. The operational supply voltage is 220/240VAC 50/60Hz. It is a type A earth-leakage protection class. The current sensitivity (IDn) is fixed to 300mA. The time delay (Dt) is instantaneous. It requires a local manual reset after a fault clearance. The monitored distribution system voltage is up to 1000VAC 50/60/400Hz. It is installed on a front panel switchboard and the protection degree is IP40. It must be associated with a compatible Schneider Electric type A toroid or rectangular sensor.
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Physical Attributes
    • Wire Stripping Length : auxiliary power supply: 7 mm, fault: 7 mm, relay test and fault reset: 7 mm, sensor: 7 mm, voltage presence: 7 mm
  • Complementary Attributes
    • Network Rated Voltage : 1000-1000 V - AC 50/60 Hz maximum), 1000-1000 V - AC 400 Hz maximum)
    • Minimum Load : 10 mA 12 V
  • Important Information Attributes
    • Persona Type Ids : LC, PB
    • Persona Type Names : Contractor, Panel Builder
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Earthing System : IT, TN-S, TT
    • Electromagnetic Compatibility : conducted and radiated emissionsB CISPR 11, conducted radio-frequency immunity test3 IEC 61000-4-6, electrostatic discharge immunity test4 IEC 61000-4-2high-energy conducted susceptibility4 IEC 61000-4-5low-energy conducted susceptibility4 IEC 61000-4-4radiated susceptibility3 IEC 61000-4-3
    • Mechanical Robustness : fire resistance IEC 60695-2-1IK protection 2 joulesIK07 EN 50102, vibrations 13.2...100 Hz0.7 gvibrations 2...13.2 Hz+/- 1 mm
    • Monitoring : electronics continuous), power supply continuous), relay/sensor link continuous)
    • Mounting Support : front panel, front panel
    • Test Function : local, remote test
    • Tightening Torque : auxiliary power supply: 0.6-0.6 N.m, fault: 0.6-0.6 N.m, relay test and fault reset: 0.6-0.6 N.m, sensor: 0.6-0.6 N.m, voltage presence: 0.6-0.6 N.m
    • Certificate Agency : EN/IEC 60947-2 Annex M, EN/IEC 60755, UL 1053, CAN/CSA C22.2 No. 144
    • Connections - Terminals : fault terminal block 0.2-2.5 mm² rigid 24 AWG...12 AWG, fault terminal block 0.25-2.5 mm² flexible 24 AWG...12 AWGrelay test and fault reset terminal block 0.2-2.5 mm² rigid 24 AWG...12 AWG, relay test and fault reset terminal block 0.25-2.5 mm² flexible 24 AWG...12 AWGsensor terminal block 0.2-2.5 mm² rigid 24 AWG...12 AWG, sensor terminal block 0.25-2.5 mm² flexible 24 AWG...12 AWGvoltage presence terminal block 0.2-2.5 mm² rigid 24 AWG...12 AWG, voltage presence terminal block 0.25-2.5 mm² flexible 24 AWG...12 AWGauxiliary power supply terminal block 0.2-2.5 mm² flexible 24 AWG...12 AWG, auxiliary power supply terminal block 0.2-2.5 mm² rigid 24 AWG...12 AWG, auxiliary power supply terminal block 0.25-2.5 mm² flexible 24 AWG...12 AWG, fault terminal block 0.2-2.5 mm² flexible 24 AWG...12 AWG, relay test and fault reset terminal block 0.2-2.5 mm² flexible 24 AWG...12 AWG, sensor terminal block 0.2-2.5 mm² flexible 24 AWG...12 AWG, voltage presence terminal block 0.2-2.5 mm² flexible 24 AWG...12 AWG
    • Carbon Footprint Of The Distribution Phase [A4] : 0.047731299163239045, 0 kg CO2 eq.
    • Carbon Footprint Of The End-of-life Phase [C1 To C4] : 0.890860002790115, 0.9 kg CO2 eq.
    • Carbon Footprint Of The Installation Phase [A5] : 0.1 kg CO2 eq., 0.07962427363551068
    • Carbon Footprint Of The Manufacturing Phase [A1 To A3] : 3 kg CO2 eq., 3.0585705310974727
    • Carbon Footprint Of The Use Phase [B2, B3, B4, B6] : 46 kg CO2 eq., 46.31700000000001
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-07-10
    • Return Indicator : N
    • Stocking Flag : Y
    • Stock Policy : 2
    • Device Type : Relay, Control & Measurement - Protection relay
    • Serviceability : Yes
    • Traceability : Yes
    • Field Service Division : PPIBS
    • Average Life Duration : 15 year(s)
    • Weee Applicability : Finished product
    • Weee Scope : In
    • Weee Product Category : 5
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI2310023EN
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : Yes
    • Rohs Eur Status : Compliant By Exemption
    • Rohs Eur Conformity Date : 1902
    • Rohs Eur Full Compliance Status : Compliant By Exemption
    • China Rohs In Scope : No
    • China Rohs Label : 7
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : No
    • Product Contributes To Saved And Avoided Emissions : No
    • Tier Id : 1
    • Tier : 1
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Product Kit Identifier : N
    • Compatibility Code : RH10P
    • Device Short Name : RH10P
    • Earth Leakage Current : 0.3-0.3 A
    • Electrical Shock Protection Class : class II
    • Energy Efficiency Optimized : False
    • Overvoltage Category : IV
    • Power Consumption In Va : 4 VA
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Or Component Type : residual current protection relay
    • Range : VigiPacT
    • Relay Application : protection relay
    • Reset : manual reset
    • Returnability : No
    • Software Version : v5.9.4
    • Sustainable Packaging : No
    • Tamperproof Of Settings : protected by sealable cover
    • Total Lifecycle Carbon Footprint : 50 kg CO2 eq.
    • Type Of Measurement : earth fault current internal measurement 80...100 %
    • Type Of Setting : none
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Supply Voltage Num 7 Network Type : AC
    • Supply Voltage Num 7 Supply Voltage Num : 220...240 V
    • R Earth Leakage Current 1 R Earth Leakage Current : 0.3-0.3 A
    • Pep Code : ENVPEP2310023EN
    • Database Version : 2022-01
    • Pep Verification Date : 2023-12-05
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed2-2016 03 29
    • Type Of Verification For The Pep : Independent external review
    • Data Source : extrapolated product
    • Functional-unit Description : Protect during 10 years people and premises at risk of fire or explosion with assigned voltage 220-240V by detecting and measuring the earth leakage current sensitivity is selectable with 9 thresholds from 30 mA to 30 A.
    • Functional-unit Quantity : 1
    • Functional-unit Unit : Unit
    • Reference Lifetime, In Y : 10
    • Energy Model - Manufacturing [A1-a3] : Electricity Mix; Production mix; Low voltage; FR
    • Energy Model - Installation [A5] : Electricity Mix; Production mix; Low voltage; UE-27
    • Energy Model - Use [B6] : Electricity Mix; Production mix; Low voltage; UE-27
    • Energy Model - End Of Life [C1-c4] : Electricity Mix; Production mix; Low voltage; UE-27
    • Recyclability Potential, In % : 27
    • Height Nominal : 72 mm
    • Width Nominal : 72 mm
    • [Ithe] Conventional Enclosed Thermal Current : 8 A
    • [Uimp] Rated Impulse Withstand Voltage : 8 kV
    • [Us] Rated Supply Voltage : 220...240 V AC 50/60 Hz 55...110 %
    • Cut-out Dimensions : 68 x 68 mm
    • Residual Earth-leakage Time Delay Adjustment Type : instantaneous
    • Earth-leakage Protection Class : type A
    • Residual Earth-leakage Sensitity Adjustment Type : fixed
    • Halogen-free Status : Product contains halogen above thresholds
    • Nbr. Of Units In Pkg. : 1
    • Package Weight(Lbs) : 365 g
    • Take-back : No
    • Warranty (In Months) : 18
    • Customs Code : 8536490080
  • Environment Attributes Main
    • China Rohs Regulation : Product out of China RoHS scope , Product out of China RoHS scope. Substance declaration for your information.
    • Ambient Air Temperature For Operation : -35-70 °C, -35-70 °C
    • Ambient Air Temperature For Storage : -55-85 °C, -55-85 °C
    • Take Back : No
    • Halogene Performance : Product contains halogen above thresholds
    • Recycled Metal Content At Cr Level : 0 %
    • Mercury Free : Yes
    • Carbon Footprint : 50.39378610668634
    • Circularity Profile : ENVEOLI2310023EN
    • Environmental Disclosure : ENVPEP2310023EN
    • Eu Rohs Directive : Compliant By Exemption
    • Halogen Content Performance : Product contains halogen above thresholds
    • Ip Degree Of Protection : IP40 on front face: conforming to EN/IEC 60529IP30 on side parts: conforming to EN/IEC 60529IP20 on connection terminals: conforming to EN/IEC 60529
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : No
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Relative Humidity : 95-95 % 55-55 °C
    • Pep Code : ENVPEP2310023EN
    • Pep Verification Date : 2023-12-05
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed2-2016 03 29
    • Type Of Verification For The Pep : Independent external review
  • General Attributes
    • Product Or Component Type : residual current protection relay
  • ETIM
    • ETIM 8 : EC001445
    • ETIM 9 : EC001445
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Specifications
    • Country of Origin : France
    • Depth : 78 mm