Regulated Power Supply, 100 to 240V AC, 24V, 5A, single phase, Optimized

POWER SUPPLY 24V 5.0A

SQDABLS1A24050 ABLS1A24050 3606481500236
338.30 / EA
http://schema.org/OutOfStock
  • Depth: 117.6 mm
  • Dielectric Strength: 3000 V
  • Enclosure Material: Aluminum
  • Input Voltage: ...240 V, ...340 V
  • Output Voltage: 24 V
This ABLS regulated switch mode power supply (SMPS) supplies direct current voltage. It has a rated input of 100V to 240V AC and 140 V to 340 V DC, a rated output current of 5A at 24V DC and a rated power output of 120W. It is ideal for supplying DC voltage necessary for automation equipment designed for applications in industrial, commercial and residential applications such as conveying, packaging, control, food & beverage, mining, oil & gas and water. It installs on omega rail or fixing by screw. Its width is 40mm, its height is 123,6mm, its depth is 117,6mm. It ensures a protection against overloads and short-circuits with automatic restart after the source of overload/short-circuit has been corrected. It weighs 0.550kg. It is a power supply for industrial use, rail mounting. It conforms to EN62368-1, ENIEC61010-1/2-201, ENIEC61204-3, EN61000-6-1/2/3/4, EN61000-3-2-3, UL62368-1, UL61010-2-201/-1-201, CSAC22.2No62368-1/No61010-2-201/No61010-1 standards, and certified by CE, CUL listed/recognized, RCM, CBscheme. The Acti9 iC60 range of Miniature Circuit Breakers is recommanded for its protection. The type of protection is 13A, C-Curve. It has in the front face a LED indicating presence of DC output voltage, and a QR code for access to the latest technical documentation. Thanks to its book housing, it can be installed either in enclosures or industrial panels by clipping on omega (DIN) rail. It brings energy to your automated systems. Designed for simple machines and applications, modular power supplies are primarily appreciated for their extreme compactness.
QTY
  • Features
  • Specifications
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Complementary Attributes
    • Maximum Leakage Current : 1 mA 240 V AC
    • Rated Power In W : 120 W
  • Important Information Attributes
    • Persona Type Ids : EU, OM, OM8
    • Persona Type Names : End User, Original Equipment Manufacturer, OEM - Control Panelbuilder
    • Current Consumption : < 2.5 A 115 V AC, < 2.5 A 115 V AC, < 2.5 A 115 V AC, < 1.4 A 230 V AC, < 1.4 A 230 V AC, < 1.4 A 230 V AC, < 1.3 A 140 V DC, < 1.3 A 140 V DC, < 1.3 A 140 V DC< 2.5 A 115 V AC, < 2.5 A 115 V AC, < 2.5 A 115 V AC, < 1.4 A 230 V AC, < 1.4 A 230 V AC, < 1.3 A 140 V DC, < 1.3 A 140 V DC, < 1.3 A 140 V DC
    • Earthing System : TN, TT, IT
    • Efficiency : 85 % 115 V AC, 88 % 230 V AC
    • Efficiency At Full Load : 85...264 V AC without temperature derating, 120...375 V DC without temperature derating
    • Electromagnetic Compatibility : immunity to electrostatic discharge - test level: 8 kV (contact discharge) conforming to IEC 61000-4-2, immunity to electrostatic discharge - test level: 15 kV (air discharge) conforming to IEC 61000-4-2, immunity to conducted RF disturbances - test level: 15 V/m (80 MHz...2 GHz) conforming to IEC 61000-4-3, immunity to conducted RF disturbances - test level: 5 V/m (2...2.7 GHz) conforming to IEC 61000-4-3, immunity to conducted RF disturbances - test level: 5 V/m (2.7...6 GHz) conforming to IEC 61000-4-3, immunity to fast transients - test level: 4 kV (on input-output) conforming to IEC 61000-4-4, surge immunity test - test level: 4 kV (between power supply and earth) conforming to IEC 61000-4-5, surge immunity test - test level: 3 kV (between phases) conforming to IEC 61000-4-5, immunity to conducted RF disturbances - test level: 15 V (0.15...80 MHz) conforming to IEC 61000-4-6, immunity to magnetic fields - test level: 30 A/m (50...60 Hz) conforming to IEC 61000-4-8, immunity to voltage dips conforming to IEC 61000-4-11, disturbing field emission conforming to EN 55016-2-3, limits for harmonic current emissions conforming to IEC 61000-3-2, conforming to EN 55016-1-2, conforming to EN 55016-2-1
    • Electromagnetic Emission : conducted emissions IEC 61000-6-3, radiated emissions IEC 61000-6-4
    • Holding Time : > 20 ms 115 V AC, > 20 ms 115 V AC, > 20 ms 115 V AC, > 40 ms 230 V AC, > 40 ms 230 V AC, > 40 ms 230 V AC> 20 ms 115 V AC, > 20 ms 115 V AC, > 20 ms 115 V AC, > 40 ms 230 V AC, > 40 ms 230 V AC
    • Inrush Current : 30.0 A 115 V, 60.0 A 230 V
    • Line And Load Regulation : < 0.5 % network 0 to 100 % load at 25 °C, < 0.5 % network 0 to 100 % load at 25 °C, < 0.5 % network 0 to 100 % load at 25 °C, < 1 % network full voltage range in line at 25 °C, < 1 % network full voltage range in line at 25 °C, < 1 % network full voltage range in line at 25 °C< 0.5 % network 0 to 100 % load at 25 °C, < 0.5 % network 0 to 100 % load at 25 °C, < 0.5 % network 0 to 100 % load at 25 °C, < 1 % network full voltage range in line at 25 °C, < 1 % network full voltage range in line at 25 °C
    • Mounting Support : top hat type TH35-15 rail IEC 60715, top hat type TH35-7.5 rail IEC 60715, double-profile DIN rail
    • Power Factor : 0.55 at 115 V AC, 0.45 at 230 V AC
    • Residual Ripple : < 120 mV, < 120 mV
    • Response Time : < 1 s, < 1 s
    • Supply : SELV IEC 60950-1, SELV IEC 60204-1, SELV IEC 60364-4-41
    • Vibration Resistance : 3 mm (f= 2-9 Hz) conforming to IEC 60068-2-6, 10 m/s² (f= 9-200 Hz) conforming to IEC 60068-2-6
    • Connections Terminals : screw connection 0.75...4 mm², AWG 18...AWG 12) with wire end ferrule inputscrew connection 0.5...4 mm², AWG 20...AWG 12) without wire end ferrule output, screw connection 0.5...2.5 mm², AWG 20...AWG 14) with wire end ferrule output, screw connection 0.75...4 mm², AWG 18...AWG 12) without wire end ferrule input
    • Carbon Footprint Of The Distribution Phase A4 : 0.2814372922210785, 0.3 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 1.317561161917302, 1 kg CO2 eq.
    • Carbon Footprint Of The Installation Phase A5 : 0 kg CO2 eq., 0.01136038423392367
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 7 kg CO2 eq., 6.538260491663987
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 1 243 kg CO2 eq., 1242.774451102273
    • Certificate Agency : CE, cUL Listed, cUL Recognized, RCM, CB Scheme, EAC, KC
    • Other Technical Guide : https://download.schneider-electric.com/files?p_Doc_Ref=ESXP1G003EN&p_File_name=ESXP1G003EN_web.pdf, ESXP1G003EN
    • Local Data Status : Publishable
    • Local Publishable Date : 2026-01-12
    • Return Indicator : Y
    • Stocking Flag : Y
    • Stock Policy : 1
    • Device Type : PLC System - PLC Component
    • Serviceability : No
    • Traceability : Yes
    • Field Service Division : IDIBS
    • Weee Scope : In
    • Weee Product Category : 5
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI2007005EN
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : No
    • Rohs Eur Status : Compliant By Exemption
    • Rohs Eur Conformity Date : 2010
    • Rohs Eur Full Compliance Status : Compliant By Exemption
    • China Rohs In Scope : Yes
    • China Rohs Label : 5
    • With Recycled Cardboard : No
    • Without Single Use Plastic : No
    • Product Contributes To Saved And Avoided Emissions : No
    • Tier Id : 1
    • Tier : 1
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Market Segmentation Id : INDUSTRIAL
    • Market Segmentation : Industrial
    • Product Kit Identifier : N
    • Dielectric Strength : 3000 V AC with input to output
    • Electrical Shock Protection Class : class I
    • Enclosure Material : Aluminum
    • Load Capacitance : 8000 µF
    • Network Frequency Limits : 50-60 Hz
    • Overvoltage Category : II
    • Power Dissipation In W : 25 W
    • Power Supply Type : regulated switch mode
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Or Component Type : power supply
    • Range Of Product : Modicon Power Supply
    • Returnability : Yes
    • Service Life : 10 year(s)
    • Shock Resistance : 150 m/s² 11 ms
    • Software Version : v6.2.5-6
    • Status Led : 1 LED (Green) output voltage
    • Sustainable Packaging : No
    • Total Lifecycle Carbon Footprint : 1 251 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Meantime Between Failure Mtbf : 700000 h at 25 °C, full load conforming to SR 332
    • Warranty In Months : 18
    • Pep Code : ENVPEP2007005_V2
    • Database Version : 45311
    • Pep Verification Date : 2025-09-18
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent internal review
    • Data Source : referent product
    • Functional-unit Description : To supply control circuits in industrial atmosphere up to 480W at 100% for 10 years.To supply control circuits in industrial atmosphere up to 480W at 100% for 10 years.
    • Functional-unit Quantity : 1
    • Functional-unit Unit : unit
    • Reference Lifetime, In Y : 10
    • Energy Consumption On Product Lifetime, In Kwh : 2190
    • Energy Model - Manufacturing [A1-a3] : Electricity Mix; Low voltage; 2020; China, CN
    • Energy Model - Installation [A5] : No energy used
    • Energy Model - Use [B6] : Electricity Mix; Low voltage; 2020; United States, US
    • Energy Model - End Of Life [C1-c4] : Global, European and French datasets are used.
    • Recyclability Potential, In % : 12
    • Height Nominal : 123.6 mm
    • Width Nominal : 40 mm
    • Total Use Of Non-renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Benefits/Loads Beyond System Boundaries [D] : 1.1724
    • Use Of Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Benefits/Loads Beyond System Boundaries [D] : 1.1724
  • Environment Attributes Main
    • Ambient Air Temperature For Operation : -20--10 °C with current derating of 2 % per °C mounting position A < 6561.68 ft (2000 m), -20--10 °C with current derating of 2 % per °C mounting position A < 6561.68 ft (2000 m), -20--10 °C with current derating of 2 % per °C mounting position A < 6561.68 ft (2000 m), -20--10 °C with current derating of 2 % per °C mounting position A < 6561.68 ft (2000 m), -10-40 °C without derating mounting position A 115 V AC < 6561.68 ft (2000 m), -10-40 °C without derating mounting position A 115 V AC < 6561.68 ft (2000 m), -10-40 °C without derating mounting position A 115 V AC < 6561.68 ft (2000 m), -10-40 °C without derating mounting position A 115 V AC < 6561.68 ft (2000 m), -10-40 °C without derating mounting position A 115 V AC < 6561.68 ft (2000 m), -10-50 °C without derating mounting position A 230 V AC < 6561.68 ft (2000 m), -10-50 °C without derating mounting position A 230 V AC < 6561.68 ft (2000 m), -10-50 °C without derating mounting position A 230 V AC < 6561.68 ft (2000 m), -10-50 °C without derating mounting position A 230 V AC < 6561.68 ft (2000 m), -10-50 °C without derating mounting position A 230 V AC < 6561.68 ft (2000 m)-20--10 °C with current derating of 2 % per °C mounting position A < 6561.68 ft (2000 m), -20--10 °C with current derating of 2 % per °C mounting position A < 6561.68 ft (2000 m), -20--10 °C with current derating of 2 % per °C mounting position A < 6561.68 ft (2000 m), -20--10 °C with current derating of 2 % per °C mounting position A < 6561.68 ft (2000 m), -10-40 °C without derating mounting position A 115 V AC < 6561.68 ft (2000 m), -10-40 °C without derating mounting position A 115 V AC < 6561.68 ft (2000 m), -10-40 °C without derating mounting position A 115 V AC < 6561.68 ft (2000 m), -10-50 °C without derating mounting position A 230 V AC < 6561.68 ft (2000 m), 40-70 °C with current derating of 1.67 % per °C mounting position A 115 V AC < 6561.68 ft (2000 m), 50-70 °C with current derating of 2.5 % per °C mounting position A 230 V AC < 6561.68 ft (2000 m)
    • Take Back : No
    • Recycled Metal Content At Cr Level : 0 %
    • China Rohs Regulation : X
    • Mercury Free : Yes
    • Carbon Footprint : 1250.9230704323093
    • Circularity Profile : ENVEOLI2007005EN
    • Environmental Disclosure : ENVPEP2007005_V2
    • Eu Rohs Directive : Compliant By Exemption
    • Ip Degree Of Protection : IP20
    • Operating Altitude : < 5000 m< 5000 m
    • Packaging Made With Recycled Cardboard : No
    • Packaging Without Single Use Plastic : No
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP2007005_V2
    • Pep Verification Date : 2025-09-18
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Product Or Component Type : power supply
    • Range Of Product : Modicon Power Supply
  • ETIM
    • ETIM 8 : EC002540
    • ETIM 9 : EC002540
  • Output Attributes
    • Output Coupling : parallel, serial
    • Output Protection Type : against overload and short-circuits, protection technology: automatic reset, against over temperature, protection technology: manual reset, against overvoltage, protection technology: manual reset
    • Output Voltage : 24 V DC
    • Output Voltage Limits : 22...28 V
    • Power Supply Output Current : 5 A
  • Input Attributes
    • Efficiency : 85 % 115 V AC, 88 % 230 V AC
    • Efficiency At Full Load : 85...264 V AC without temperature derating, 120...375 V DC without temperature derating
    • Input Protection Type : integrated fuse (not interchangeable) 4 A, external protection (recommended) 20 A Curve C, external protection (recommended) 13 A Curve C
    • Input Voltage : 100...240 V AC single phase, 100...240 V AC phase to phase, 140...340 V DC
  • Specifications
    • Country of Origin : India, Singapore, United States
    • Depth : 117.6 mm