Regulated Power Supply, modicon power supply, 100...240V AC, 12V, 8.5A, single phase, Panel Mount

REGULATED POWER SUPPLY, 100...

SQDABLP1A12085 ABLP1A12085 3606481500274
182.44 / EA
http://schema.org/OutOfStock
  • Depth: 129 mm
  • Dielectric Strength: 3750 V
  • Enclosure Material: Aluminum
  • Input Voltage: ...240 V
  • Output Voltage: 12 V
This Modicon ABLP regulated switch mode power supply (SMPS) supplies direct current voltage. It has a rated input of 100V to 240V AC, a rated output current of 8.5A at 12V DC and a rated power of 100W. It is ideal for supplying DC voltage necessary for automation equipment designed for applications in industrial, commercial and residential applications such as conveying, packaging, control, food & beverage, mining, oil & gas and water. It provides a protection against overloads and short-circuits with automatic restart after the source of overload/short-circuit has been corrected It has LED diagnostics indicator available in the front for troubleshooting instantly. Its width is 97mm, its height is 30mm, its depth is 129mm. It weighs 0.300kg. It is certified with CB-Scheme, cULus Listed, cURus recognized, RCM and EAC. It is a power supply for commercial use, panel mount; It is compatible with ABLPA01 mounting plate. It installs on panel on side or on base with mounting plate fixing by screw. ABLP power supplies bring energy to your automated systems. ABLP power supplies are designed for simple and repetitive machines, dedicated power supplies are particularly quality/price competitive due to their simplicity and compactness. The main applications to use Modicon ABLP power supply are lifts, display panels, escalators, carwash, foodstuff ovens, etc.
QTY
  • Features
  • Specifications
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Complementary Attributes
    • Maximum Leakage Current : 1 mA 240 V AC
    • Rated Power In W : 100 W
  • Important Information Attributes
    • Persona Type Ids : EU, OM, OM8
    • Persona Type Names : End User, Original Equipment Manufacturer, OEM - Control Panelbuilder
    • Current Consumption : < 2.3 A 115 V AC, < 2.3 A 115 V AC, < 2.3 A 115 V AC, < 1.5 A 230 V AC, < 1.5 A 230 V AC, < 1.5 A 230 V AC< 2.3 A 115 V AC, < 2.3 A 115 V AC, < 2.3 A 115 V AC, < 1.5 A 230 V AC, < 1.5 A 230 V AC
    • Earthing System : TN, TT, IT
    • Electromagnetic Compatibility : immunity to electrostatic discharge - test level: 8 kV (contact discharge) conforming to IEC 61000-4-2, immunity to electrostatic discharge - test level: 15 kV (air discharge) conforming to IEC 61000-4-2, immunity to conducted RF disturbances - test level: 15 V/m (80 MHz...2 GHz) conforming to IEC 61000-4-3, immunity to conducted RF disturbances - test level: 5 V/m (2...2.7 GHz) conforming to IEC 61000-4-3, immunity to conducted RF disturbances - test level: 5 V/m (2.7...6 GHz) conforming to IEC 61000-4-3, immunity to fast transients - test level: 4 kV (on input-output) conforming to IEC 61000-4-4, surge immunity test - test level: 4 kV (between power supply and earth) conforming to IEC 61000-4-5, surge immunity test - test level: 3 kV (between phases) conforming to IEC 61000-4-5, immunity to conducted RF disturbances - test level: 15 V (0.15...80 MHz) conforming to IEC 61000-4-6, immunity to magnetic fields - test level: 30 A/m (50...60 Hz) conforming to IEC 61000-4-8, immunity to voltage dips conforming to IEC 61000-4-11, disturbing field emission conforming to EN 55016-2-3, limits for harmonic current emissions conforming to IEC 61000-3-2, conforming to EN 55016-1-2, conforming to EN 55016-2-1
    • Electromagnetic Emission : conducted emissions IEC 61000-6-3, radiated emissions IEC 61000-6-4
    • Holding Time : > 20 ms 115 V AC, > 20 ms 115 V AC, > 20 ms 115 V AC, > 40 ms 230 V AC, > 40 ms 230 V AC, > 40 ms 230 V AC> 20 ms 115 V AC, > 20 ms 115 V AC, > 20 ms 115 V AC, > 40 ms 230 V AC, > 40 ms 230 V AC
    • Inrush Current : 45 A 115 V, 85 A 230 V
    • Line And Load Regulation : < 0.5 % network 0 to 100 % load at 25 °C, < 0.5 % network 0 to 100 % load at 25 °C, < 0.5 % network 0 to 100 % load at 25 °C, < 1 % network full voltage range in line at 25 °C, < 1 % network full voltage range in line at 25 °C, < 1 % network full voltage range in line at 25 °C< 0.5 % network 0 to 100 % load at 25 °C, < 0.5 % network 0 to 100 % load at 25 °C, < 0.5 % network 0 to 100 % load at 25 °C, < 1 % network full voltage range in line at 25 °C, < 1 % network full voltage range in line at 25 °C
    • Mounting Support : top hat type TH35-15 rail IEC 60715, top hat type TH35-7.5 rail IEC 60715, double-profile DIN rail, panel mounting
    • Power Factor : 0.55 at 115 V AC, 0.45 at 230 V AC
    • Residual Ripple : < 120 mV, < 120 mV
    • Response Time : < 500 ms, < 500 ms
    • Supply : SELV IEC 60950-1, SELV IEC 60204-1, SELV IEC 60364-4-41
    • Vibration Resistance : 3 mm (f= 2-9 Hz) conforming to IEC 60068-2-6, 10 m/s² (f= 9-200 Hz) conforming to IEC 60068-2-6
    • Connections Terminals : screw connection 0.75...2.5 mm², AWG 18...AWG 14) without wire end ferrule, screw connection 0.75...1.5 mm², AWG 18...AWG 16) with wire end ferrule
    • Carbon Footprint Of The Distribution Phase A4 : 0.0541889607, 0.1 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 0.2283768591, 0.2 kg CO2 eq.
    • Carbon Footprint Of The Installation Phase A5 : 0 kg CO2 eq., 0.0071802674
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 6 kg CO2 eq., 5.7846671388
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 901 kg CO2 eq., 901.299
    • Certificate Agency : CE, cULus, EAC, RCM, CB Scheme, KC
    • Local Data Status : Publishable
    • Local Publishable Date : 2026-01-12
    • Return Indicator : Y
    • Stocking Flag : N
    • Stock Policy : 2
    • Device Type : PLC System - PLC Component
    • Serviceability : No
    • Traceability : Yes
    • Field Service Division : IDIBS
    • Use Carbon Footprint : 901.299
    • Weee Scope : In
    • Weee Product Category : 5
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI2007017EN
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : No
    • Rohs Eur Status : Compliant By Exemption
    • Rohs Eur Conformity Date : 2010
    • Rohs Eur Full Compliance Status : Compliant By Exemption
    • China Rohs In Scope : Yes
    • China Rohs Label : 5
    • With Recycled Cardboard : No
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Tier Id : 1
    • Tier : 1
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Market Segmentation Id : INDUSTRIAL
    • Market Segmentation : Industrial
    • Product Kit Identifier : N
    • Dielectric Strength : 3750 V AC with input to output
    • Efficiency : 88 % 230 V AC
    • Efficiency At Full Load : 90...264 V AC
    • Electrical Shock Protection Class : class I
    • Enclosure Material : Aluminum
    • Load Capacitance : 4000 µF
    • Network Frequency Limits : 50-60 Hz
    • Overvoltage Category : II
    • Power Dissipation In W : 21 W
    • Power Supply Type : regulated switch mode
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Or Component Type : power supply
    • Range Of Product : Modicon Power Supply
    • Returnability : Yes
    • Service Life : 10 year(s)
    • Shock Resistance : 150 m/s² 11 ms
    • Software Version : EIME v5.8.1
    • Status Led : 1 LED (Green) output voltage
    • Sustainable Packaging : No
    • Total Lifecycle Carbon Footprint : 907 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Meantime Between Failure Mtbf : 700000 h at 25 °C, full load conforming to SR 332
    • Warranty In Months : 18
    • Pep Code : ENVPEP2007017EN
    • Database Version : 2016-11
    • Pep Verification Date : 2020-08-01
    • Pcr Version : PCR-ed3-EN-2015 04 02
    • Psr Version : PSR-0010-ed1.1-EN-2015 10 16
    • Type Of Verification For The Pep : Independent internal review
    • Data Source : extrapolated product
    • Functional-unit Description : To supply control circuits in commercial automation up to 240W at 100% for 10 years.
    • Functional-unit Quantity : 1
    • Functional-unit Unit : unit
    • Reference Lifetime, In Y : 10
    • Energy Consumption On Product Lifetime, In Kwh : 1839.6
    • Energy Model - Manufacturing [A1-a3] : Energy model used: China
    • Energy Model - Installation [A5] : Electricity mix; AC; < 1kV; EU-27
    • Energy Model - Use [B6] : Electricity mix; AC; < 1kV; EU-27
    • Energy Model - End Of Life [C1-c4] : Electricity mix; AC; < 1kV; EU-27
    • Height Nominal : 30 mm
    • Width Nominal : 97 mm
    • Air Pollution (M3) Operational Energy Use [B6] : 38792.25
    • Depletion Of Abiotic Resources - Fossil Fuels (Mj) Operational Energy Use [B6] : 10230.57
    • Global Warming (Kg.Equivalent.Co2) Operational Energy Use [B6] : 901.299
    • Net Use Of Fresh Water (M3) Operational Energy Use [B6] : 3268.02
    • Non-hazardous Waste Disposed Of (Kg) Operational Energy Use [B6] : 3360.42
    • Total Use Of Non-renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Operational Energy Use [B6] : 15712.2
    • Total Use Of Primary Energy During The Life Cycle (Mj) Operational Energy Use [B6] : 18001.2
    • Total Use Of Renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Operational Energy Use [B6] : 2289
    • Use Of Non-renewable Primary Energy, Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Operational Energy Use [B6] : 15712.2
    • Use Of Renewable Primary Energy, Excluding Renewable Primary Energy Resources Used As Raw Materials (Mj) Operational Energy Use [B6] : 2289
    • Water Pollution (M3) Operational Energy Use [B6] : 37191
  • Environment Attributes Main
    • Ambient Air Temperature For Operation : -30-50 °C without derating mounting position A, B, F, G < 6561.68 ft (2000 m), -30-50 °C without derating mounting position A, B, F, G < 6561.68 ft (2000 m), -30-50 °C without derating mounting position A, B, F, G < 6561.68 ft (2000 m), -30-50 °C without derating mounting position A, B, F, G < 6561.68 ft (2000 m)-30-50 °C without derating mounting position A, B, F, G < 6561.68 ft (2000 m), -30-50 °C without derating mounting position A, B, F, G < 6561.68 ft (2000 m), -30-50 °C without derating mounting position A, B, F, G < 6561.68 ft (2000 m), -30-50 °C without derating mounting position A, B, F, G < 6561.68 ft (2000 m), 50-70 °C with current derating of 2 % per °C mounting position A, B, F, G < 6561.68 ft (2000 m)
    • Take Back : No
    • Recycled Metal Content At Cr Level : 0 %
    • China Rohs Regulation : X
    • Mercury Free : Yes
    • Carbon Footprint : 907.3734132259
    • Circularity Profile : ENVEOLI2007017EN
    • Environmental Disclosure : ENVPEP2007017EN
    • Eu Rohs Directive : Compliant By Exemption
    • Ip Degree Of Protection : IP10
    • Operating Altitude : 5000 m
    • Packaging Made With Recycled Cardboard : No
    • Packaging Without Single Use Plastic : Yes
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP2007017EN
    • Pep Verification Date : 2020-08-01
    • Pcr Version : PCR-ed3-EN-2015 04 02
    • Psr Version : PSR-0010-ed1.1-EN-2015 10 16
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Product Or Component Type : power supply
    • Range Of Product : Modicon Power Supply
  • ETIM
    • ETIM 8 : EC002540
    • ETIM 9 : EC002540
  • Output Attributes
    • Output Coupling : parallel, serial
    • Output Protection Type : against overload and short-circuits, protection technology: automatic reset, against over temperature, protection technology: manual reset, against overvoltage, protection technology: manual reset
    • Output Voltage : 12 V DC
    • Output Voltage Limits : 10.8...13.2 V
    • Power Supply Output Current : 8.5 A
  • Input Attributes
    • Efficiency : 88 % 230 V AC
    • Efficiency At Full Load : 90...264 V AC
    • Input Protection Type : integrated fuse (not interchangeable) 4 A
    • Input Voltage : 100...240 V AC single phase
  • Specifications
    • Country of Origin : China, France, Philippines, United States
    • Depth : 129 mm