Protection and control relay, PowerLogic P7, feeder standard, 5CT, 4VT, 24BI, 20BO, 24-34V, ethernet RJ45

Protection and control relay, PowerLogic P7, feeder standard, 5CT, 4VT, 24BI, 20BO, 24-34V, ethernet RJ45

SQDREL71500 REL71500 3606486926680
8219.87 / EA
http://schema.org/OutOfStock
  • Depth: 282 mm
  • Display Type: Colour Touchscreen 800 X 640 Pixels
  • Height: 7.01 in
  • Number of Outputs: 201 Watchdog
  • Warranty Length: 10 yr, 2 yr
  • Width: 8.08 in
QTY
  • Features
  • Specifications
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Communications & Management Attributes
    • Communication Compatibility : DNP3, Modbus, IEC 61850 Ed 2.1
    • Communication Port Protocol : Modbus serial and TCP, DNP3 serial and TCP, IEC 61850 Ed 2.1, IEC 61869-9, IEC 61850-9-2 LE
    • Redundancy Communication Port Protocol : HSR, PRP, RSTP, failover
  • Physical Attributes
    • Display Size : 7 inch
    • Mounting Case Size : 40TE
  • Complementary Attributes
    • Integrated Connection Type : 1 CAN port, 1 Ethernet TCP/IP, 2 SFP ports, 1 USB port, 1 COM serial link
    • Maximum Power Consumption In W : 24 W typical
  • Important Information Attributes
    • Control Button Type : 1 home physical key, 1 reset physical key, 12 customizable virtual function keys
    • Control Type : switchgear control and monitoring, programmable switchgear interlocking, local/, programmable logic, remote control, function keys
    • Cybersecurity : IEC 62443 SL2, LDAP, RADIUS based user authentication, port hardening, role-based access control, secure boot, security log, Syslog protocol support, firmware signature, client IP address filter, pre-login banner, security policy management
    • Electromagnetic Compatibility : electromagnetic immunity class A CISPR 11, electromagnetic immunity class A CISPR 22electromagnetic immunity level 3 IEC 6100-4-3, radiated radio-frequency electromagnetic field immunity test level 4 ANSI C37.90.2electrostatic discharge level 4 IEC 6100-4-2electrostatic discharge level 5 ANSI C37.90.3immunity to magnetic fields level 4 IEC 61000-4-8, immunity to magnetic fields level 5 IEC 61000-4-9fast transient bursts level 4 IEC 61000-4-4damped oscillatory wave level 3 IEC 61000-4-18damped oscillatory wave A ANSI C37.90.1, damped oscillatory wave level 3 IEC 61000-4-12conducted disturbance emission A IEC 61000-4-16surges level 4 IEC 61000-4-5
    • Environmental Characteristic : exposure to cold Ae IEC 60068-2-1, exposure to dry heat Be IEC 60068-2-2, exposure to damp heat in service Cab IEC 60068-2-78, temperature variation Nb IEC 60068-2-14exposure to damp heat not in service Cab IEC 60068-2-30, salt mist Kb/1 IEC 60068-2-52, influence of corrosion/gas test 2 Ke IEC 60068-2-60, influence of corrosion/gas test 4 Ke IEC 60068-2-60
    • Information Displayed : single line diagram, menu-driven user interface
    • Local Signalling : 4 LEDs red/orange device status, 24 LEDs tri-colour programmable
    • Mechanical Robustness : vibrations class 2) IEC 60255-21-1shocks class 2) IEC 60255-21-2, shocks class 1) IEC 60255-21-2, bumps class 1) IEC 60255-21-2seismic tests class 2) IEC 60255-21-3
    • Monitoring Function : circuit breaker monitoring, switch monitoring, relay self-monitoringtrip circuit supervision 74, event counters, watchdog
    • Mounting Mode : flush mounting, rack-mounted
    • Network And Machine Diagnosis Type : disturbance recording, event recording, fault recording, operation log
    • Protection Type : phase overcurrent 50/51ground fault protection 50N/51Nsensitive earth fault overcurrent 50G/51Gnegative sequence overcurrent 46inrush detection 68voltage-dependent overcurrent 51Vundervoltage 27overvoltage 59underfrequency 81Udirectional phase overcurrent 67directional earth fault 67Noverfrequency 81Otemperature monitoring (8 RTDs) 38/49Tpositive sequence undervoltage 47neutral voltage displacement 59Ndirectional reactive overpower 32Qearth fault wattmetric 32Nearth fault admittance 21Ndirectional active overpower 32Pdirectional active underpower 37Prate of change of frequency 81Rthermal overload for feeder 49FCT supervision 60VT supervision 60FLbreaker failure 50 BFsynchro-check 25, programmable logic
    • Switchgear Diagnosis Type : CT/VT supervision 60, auxiliary power supply monitoring, cumulative breaking current, number of operations, DC battery voltage monitoring
    • Time Synchronisation Protocol : IRIG-B, SNTP, IEEE 1588
    • Type Of Measurement : RMS voltage sequencereactive demand minimumapparent demand minimumRMS phase current demand minimumcurrent 3-phase, RMS current 3-phase, current sequence, current 1-phase, voltage 3-phase, RMS voltage 3-phaseactive fundamental frequency, apparent fundamental frequency, reactive fundamental frequency, RMS active 1-phase, RMS reactive 1-phase, RMS apparent 3-phaseactive demand maximum, active demand minimum, reactive demand maximum, apparent demand maximum, RMS phase current demand maximum, power, power factor, harmonic distortion (I THD & U THD), voltage sags and swells, earth fault current external measurement
    • Certificate Agency : cUL Listed, UKCA, KETOP, CE, DNV
    • Carbon Footprint Of The Distribution Phase [A4] : 2.424296070676455, 2 kg CO2 eq.
    • Carbon Footprint Of The End-of-life Phase [C1 To C4] : 12 kg CO2 eq., 12.138714057358866
    • Carbon Footprint Of The Installation Phase [A5] : 1.2459526085230819, 1 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase [A1 To A3] : 683 kg CO2 eq., 682.728649177306
    • Carbon Footprint Of The Use Phase [B2, B3, B4, B6] : 1 011 kg CO2 eq., 1010.7000000000003
    • Other Technical Guide : https://download.schneider-electric.com/files?p_Doc_Ref=&p_File_name=PowerLogic P7_DNP3Profile_V2.4.1.xlsx, https://download.schneider-electric.com/files?p_Doc_Ref=&p_File_name=PowerLogic P7_ModbusProfile_V2.4.1.xlsx, https://download.schneider-electric.com/files?p_Doc_Ref=&p_File_name=PowerLogic P7_T103Profile_V2.4.1.xlsx, P7_Protocol_profiles
    • Local Data Status : Publishable
    • Local Publishable Date : 2024-11-18
    • Pre Comm Date : 2024-01-16
    • Return Indicator : N
    • Stocking Flag : Y
    • Stock Policy : 2
    • Device Type : Relay, Control & Measurement - Protection relay
    • Serviceability : Yes
    • Traceability : Yes
    • Field Service Division : DPIBS
    • Average Life Duration : 15 year(s)
    • Weee Scope : In
    • Weee Product Category : 5
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI2202030_V1
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : Yes
    • Rohs Eur Status : Compliant By Exemption
    • Rohs Eur Conformity Date : 2349
    • Rohs Eur Full Compliance Status : Compliant By Exemption
    • China Rohs In Scope : Yes
    • China Rohs Label : 4
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : No
    • Product Contributes To Saved And Avoided Emissions : No
    • Product Kit Identifier : N
    • Device Connection : connection to a PC USBextension port extension cableEthernet port RJ45serial port RS485 cableSFP redundant Ethernet port fibre optic/RJ45 multi/single mode optional
    • Device Short Name : P7
    • Display Type : colour touchscreen 800 x 640 pixels
    • Mounting Support : 19" rack
    • Operating Threshold : 24 V DC
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Or Component Type : protection and control relay
    • Protective Treatment : conformal coating conforming to IEC 60068-2-52:Kb/1conformal coating conforming to IEC 60068-2-60:Ke
    • Range Of Product : PowerLogic P7
    • Relay Application : feeder application and bay control
    • Returnability : No
    • Setting : 8
    • Single Line Diagram : 11 controlled objects including 2 CBs
    • Software Name : PowerLogic Engineering Suite
    • Software Version : v5.9.4
    • Sustainable Packaging : No
    • Total Lifecycle Carbon Footprint : 1 709 kg CO2 eq.
    • Transmission Support Medium : 2 twisted, type A, shielded wires (RS485)
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Pep Code : ENVPEP2202030EN
    • Database Version : 2022-01
    • Pep Verification Date : 2025-03-18
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed2-2016 03 29
    • Type Of Verification For The Pep : Independent external review
    • Data Source : extrapolated product
    • Functional-unit Description : To protect a Motor, Generator, Feeder, Transformer, Distance, Line-Differential. Display is 192mm by 192mm color graphical LCD with a touchscreen interface. The information available from the display: power, energy consumption, harmonics, frequency, voltage, current, alarms, and input-output status. The Energy consumption is 24W power in active mode & 20W in Standby mode. 5% Time repartition in Active mode & 95% Time repartition in Standby mode during the reference lifetime of 10 years.
    • Functional-unit Quantity : 1
    • Functional-unit Unit : unité (unit)
    • Reference Lifetime, In Y : 10
    • Energy Consumption On Product Lifetime, In Kwh : 1769.52
    • Energy Model - Manufacturing [A1-a3] : Electricity Mix; Production mix; Low voltage; CH
    • Energy Model - Installation [A5] : Electricity Mix; AC; consumption mix, at consumer; 1kV - 60kV; EU-27
    • Energy Model - Use [B6] : Electricity Mix; AC; consumption mix, at consumer; 1kV - 60kV; EU-27
    • Energy Model - End Of Life [C1-c4] : Electricity Mix; AC; consumption mix, at consumer; 1kV - 60kV; EU-27
    • Recyclability Potential, In % : 38
    • Height Nominal : 178 mm
    • Height Useful : 178 mm
    • Width Nominal : 205.2 mm
    • Width Real : 205.2 mm
    • [Us] Rated Supply Voltage : 24...34 V DC
    • Connections - Terminals : screw type terminals (digital input/output)ring terminal (analogue input)
    • Nbr. Of Units In Pkg. : 1
    • Package Weight(Lbs) : 8.217 kg
    • Take-back : No
    • Warranty (In Months) : 24
    • Customs Code : 8537109170
  • Environment Attributes Main
    • Ambient Air Temperature For Operation : -40-70 °C 96 h ), -40-70 °C 96 h )-40-70 °C 96 h ), -40-70 °C 96 h )
    • Ambient Air Temperature For Storage : -40-85 °C (96 h), -40-85 °C (96 h)-40-85 °C (96 h), -40-85 °C (96 h)
    • Take Back : No
    • Recycled Metal Content At Cr Level : 0 %
    • China Rohs Regulation : X
    • Carbon Footprint : 1709.2376119138646
    • Circularity Profile : ENVEOLI2202030_V1
    • Environmental Disclosure : ENVPEP2202030EN
    • Eu Rohs Directive : Compliant By Exemption
    • Ip Degree Of Protection : IP54 front IEC 60529IP30 case IEC 60529IP20 rear IEC 60529
    • Operating Altitude : 6561.68 ft (2000 m)
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : No
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Relative Humidity : 0-93 % at 40-40 °C, without condensation, 56 days
    • Pep Code : ENVPEP2202030EN
    • Pep Verification Date : 2025-03-18
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed2-2016 03 29
    • Type Of Verification For The Pep : Independent external review
  • General Attributes
    • Product Or Component Type : protection and control relay
    • Range Of Product : PowerLogic P7
  • Output Attributes
    • Number Of Outputs : 201 watchdog
  • Contractual Warranty Attributes
    • Warranty Period : up to 10 years extended warranty (Standard warranty 2 years. Please check with your local SE representative for extended warranty availability and conditions)
    • Warranty : up to 10 years extended warranty (Standard warranty 2 years. Please check with your local SE representative for extended warranty availability and conditions)
  • Input Attributes
    • Number Of Inputs : 4 CT 1/5 A1 CT 1 A, 4 VT
    • Analogue Input Number : 8 RTD optional
    • Digital Input Number : 24
    • Input Power Interruption : 50 ms
  • Specifications
    • Country of Origin : China, Latvia
    • Height : 7.01 in
    • Width : 8.08 in
    • Depth : 282 mm