SQUARE D

Circuit breaker, PowerPacT Q, 100A, 2 pole, 240VAC, 10kA, lugs, thermal magnetic, 80%, bottom of panel

Circuit breaker, PowerPacT Q, 100A, 2 pole, 240VAC, 10kA, lugs, thermal magnetic, 80%, bottom of panel

SQDQBP22100TM QBP22100TM 785901662716
504.38 / EACH
http://schema.org/OutOfStock
  • Depth: 3.93 in
  • Warranty Length: 18 mth
PowerPacT Q-Frame circuit breakers are used for overcurrent protection and switching on 240VAC systems. They are rated for 240VAC operational voltage and provide thermal magnetic trip protection. PowerPacT Q circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. This unit has terminal nuts on the line side and lugs on the load side. It has studs on line end with nuts and washers. This PowerPacT Q, 100A, 2 pole, circuit breaker has an interrupting rating of 10kA at 208Y/120VAC and 240VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT Q circuit breakers comply to UL, CSA, and NOM standards and are IEC certified.
QTY
  • Product Description
  • Features
  • Specifications
PowerPacT Q-Frame circuit breakers are used for overcurrent protection and switching on 240VAC systems. They are rated for 240VAC operational voltage and provide thermal magnetic trip protection. PowerPacT Q circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. This unit has terminal nuts on the line side and lugs on the load side. It has studs on line end with nuts and washers. This PowerPacT Q, 100A, 2 pole, circuit breaker has an interrupting rating of 10kA at 208Y/120VAC and 240VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT Q circuit breakers comply to UL, CSA, and NOM standards and are IEC certified.
  • Features
    • Available in 2 or 3 pole design
    • Overcurrent protection and switching on AC systems
    • Common accessories across the range
    • Confidence and power reliability
    • UL 489 Listed, CSA, ANCE, IEC certified
  • Assets
    • Cad : https://download.schneider-electric.com/files?p_Doc_Ref=48996-020-01&p_File_name=48996-020-01.dwg, https://download.schneider-electric.com/files?p_Doc_Ref=48996-020-01&p_File_name=48996-020-01.dxf
  • Physical Attributes
    • Wire Stripping Length : 22 mm
  • Conformance Attributes
    • Product Certifications : UL, CSA, NOM
    • Standards : UL, CSA, NEMA, NOM-003-SCFI-2000
  • Complementary Attributes
    • Line Rated Current : 100-100 A
    • Ue Rated Operational Voltage : 240 V AC 50/60 Hz UL
    • Uimp Rated Impulse Withstand Voltage : 8 kV UL
  • Important Information Attributes
    • Persona Type Ids : EU, EUA, LC, OM, SC
    • Persona Type Names : End User, Consumer, Contractor, Original Equipment Manufacturer, Electrician
    • Electrical Connection : terminal nut, line, lugs, load
    • Mechanical Durability : 1000 cycles loaded, 5000 cycles no load
    • Carbon Footprint Of The Distribution Phase A4 : 0.319968823, 0.3 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 2 kg CO2 eq., 2.149821148
    • Carbon Footprint Of The Installation Phase A5 : 0, 0 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 12 kg CO2 eq., 11.68928785
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 172 kg CO2 eq., 172.4063063
    • Medium Desc : Circuit breaker, PowerPacT Q, 100A, 2 pole, 240VAC, 10kA, lugs, thermal magnetic, 80%, bottom of panel
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-11-13
    • Global Commercial Status : Commercialised
    • Return Indicator : Y
    • Stocking Flag : N
    • H And D Domain : Safety
    • H And D Subrange : RESI
    • H And D Enrichment Assignment : no
    • H And D Enrichment Function : ENCLOSURES
    • H And D Enrichment Class 3 : Circuit Breakers
    • H And D Enrichment Class 4 : MCCB
    • Device Type : LV equipment - Low voltage circuit breaker
    • Serviceability : No
    • Traceability : Yes
    • Field Service Division : PPIBS
    • Average Life Duration : 15 year(s)
    • Legacy Weee Scope : In
    • Scope Perimeter : Outside of Europe
    • Eoli Availability Display : No need of specific recycling operations
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : Yes
    • Rohs Eur Status : Compliant By Exemption
    • Rohs Eur Full Compliance Status : Compliant By Exemption
    • China Rohs In Scope : No
    • With Recycled Cardboard : No
    • Without Single Use Plastic : No
    • Product Contributes To Saved And Avoided Emissions : No
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Market Segmentation Id : COMMERCIAL
    • Market Segmentation : Commercial
    • Product Kit Identifier : N
    • Circuit Breaker Application : HACR rated
    • Continuous Current Rating : 80 %
    • Control Type : operating handle
    • Device Application : distribution
    • Energy Efficiency Optimized : False
    • Halogen Free Status : Halogen free product
    • Local Signalling : 1 trip indicator green)
    • Magnetic Hold Current : 1200 A
    • Magnetic Tripping Current : 2400-2400 A
    • Mounting Mode : unit mount lug)
    • Mounting Support : lug
    • Network Frequency : 50/60 Hz
    • Poles Description : 2P
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Name : PowerPact Q
    • Product Or Component Type : circuit breaker
    • Range : PowerPact
    • Returnability : Yes
    • Software Version : v6.1
    • Sustainable Packaging : No
    • Tightening Torque : 28-28 N.m 25-150 mm² (AWG 4...300 kcmil)
    • Total Lifecycle Carbon Footprint : 187 kg CO2 eq.
    • Trip Unit Technology : thermal-magnetic
    • Utilisation Category : category A
    • Pep Code : ENVPEP2311048EN
    • Database Version : 2023-02
    • Pep Verification Date : 2024-03-01
    • Pcr Version : PCR-4-ed4-EN-2021 09 06
    • Psr Version : PSR-0005-ed3-EN-2023 06 06
    • Type Of Verification For The Pep : Independent internal review
    • Data Source : extrapolated product
    • Functional Unit Description : Protect the installation from overloads and short circuits in a circuit with rated voltage Ue, rated current In, with Np poles, a rated breaking capacity Icn, and the tripping curve Cd if applicable, and, if applicable, the specific specifications, in the Household/Commercial application area, according to the appropriate use scenario, and during the reference service life of the product of 20 years.
    • Functional Unit Unit : unit
    • Energy Model Manufacturing A1 A3 2 : Mexico, MX
    • Energy Model Installation A5 2 : Electricity Mix; Low voltage; 2018; United States, US
    • Energy Model Use B6 2 : Electricity Mix; Low voltage; 2018; United States, US
    • Energy Model End Of Life C1 C4 2 : Electricity Mix; Low voltage; 2018; United States, US
    • Height Nominal : 6.47 in
    • Width Nominal : 3.00 in
  • Environment Attributes Main
    • China Rohs Regulation : Product out of China RoHS scope , Product out of China RoHS scope. Substance declaration for your information.
    • Take Back : Nej
    • Halogene Performance : Halogen free product
    • Recycled Metal Content At Cr Level : 0 %
    • Mercury Free : Yes
    • Carbon Footprint : 186.5653841
    • Ambient Air Temperature For Operation : 40-70 °C
    • Environmental Disclosure : ENVPEP2311048EN
    • Eu Rohs Directive : Compliant By Exemption
    • Halogen Content Performance : Halogen free product
    • Packaging Made With Recycled Cardboard : No
    • Packaging Without Single Use Plastic : No
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP2311048EN
    • Pep Verification Date : 2024-03-01
    • Pcr Version : PCR-4-ed4-EN-2021 09 06
    • Psr Version : PSR-0005-ed3-EN-2023 06 06
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Product Or Component Type : circuit breaker
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Specifications
    • Depth : 3.93 in