PowerLogic P5M30 48-250V 3CT 2Io 4VT 31DI-15DO 3 Arc Sensors Advanced Logic and Cybersec Backup memory ANSI

PowerLogic P5M30 48-250V 3CT 2

SQDREL50482 REL50482 3606482117860
9828.16 / EA
http://schema.org/OutOfStock
  • Country of Origin: Latvia
  • Depth: 205 mm
  • Display Type: LCD 128 X 64 Pixels With Single Line Diagram
  • Height: 6.67 in
  • Number of Outputs: 1 Watchdog, 8 Watchdog
  • Warranty Length: 10 yr, 2 yr
  • Width: 6.69 in
QTY
  • Features
  • Specifications
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Communications & Management Attributes
    • Communication Port Protocol : IEC 61850 ed. 1, IEC 61850 ed. 2, IEC 60870-5-101, DNP3 TCP, Modbus TCP, EtherNet/IP
    • Redundancy Communication Port Protocol : RSTP, PRP
  • Physical Attributes
    • Mounting Case Size : 30TE
  • Complementary Attributes
    • Integrated Connection Type : front USB port 1, rear RJ45 2 with backup memory
  • Important Information Attributes
    • Control Type : switchgear control and monitoring, programmable switchgear interlocking, local control on single-line diagram, local control with I/O keys, local/remote control, 2 function keys, mobile application with Easergy SmartApp, web-server, programmable logic
    • Cybersecurity : port hardening, firmware signature, client IP address filter, secured communication with assciated tools, security policy management, role-based access control, security log, LDAP, RADIUS based user authentication, IEC 62443-4-2 SL1
    • Electromagnetic Compatibility : emission tests class A IEC/EN 60255-26 ed. 3, emission tests class A CISPR 11, emission tests class A CISPR 32, EMC immunity IEC/EN 60255-26 ed. 3, EMC immunity EN/IEC 61000-4-18, EMC immunity level 4 EN/IEC 61000-4-2, EMC immunity level 3 EN/IEC 61000-4-3, EMC immunity level 4 EN/IEC 61000-4-4, EMC immunity level 3 EN/IEC 61000-4-5, EMC immunity level 3 EN/IEC 61000-4-6, EMC immunity level 3 EN/IEC 61000-4-8, EMC immunity level 4 level 5 EN/IEC 61000-4-9, EMC immunity level 4 EN/IEC 61000-4-29, EMC immunity level 3 EN/IEC 61000-4-11, EMC immunity level 5 EN/IEC 61000-4-17, EMC immunity level 5 IEC 61000-4-9, EMC immunity level 5 IEC 61000-4-10, EMC immunity IEC 61000-4-12, EMC immunity level 4 IEC 61000-4-16, EMC immunity level 3 IEC 61000-4-18
    • Environmental Characteristic : exposure to dry heat Bb EN/IEC 60068-2-2, exposure to cold Ad EN/IEC 60068-2-1, exposure to damp heat in service Db EN/IEC 60068-2-30, exposure to damp heat in service Cab EN/IEC 60068-2-78, temperature variation IEC 60068-2-14, salt mist IEC 60068-2-52, influence of corrosion/gas test 2 IEC 60068-2-60, influence of corrosion/gas test 4 IEC 60068-2-60, stationary use at weather protected locations IEC 60721-3-3
    • Local Signalling : 10 x 4 LEDs tri-colour programmable, 4 x 8 LEDs red programmable
    • Mechanical Robustness : bumpsEa IEC 60068-2-27vibrations class II) IEC 60255-21-1, vibrations class 2) Fc IEC 60068-2-6, shocks class II) IEC 60255-21-2, shocksEa IEC 60068-2-27, seismic tests method A class II) IEC 60255-21-3, bumps class II) IEC 60255-21-2
    • Monitoring Function : trip circuit supervision 74, circuit breaker monitoring, relay self-monitoring
    • Network And Machine Diagnosis Type : event recording, disturbance recording, tripping context
    • Number Of Sensors : 0 temperature sensor(s), 0 arc sensor(s)
    • Protection Type : phase overcurrent 50/51, directional phase overcurrent 67, earth fault overcurrent 50N/51N, directional earth fault 67N, transient earth fault 67NI, capacitor bank unbalance 51C, broken conductor 46 I2/I1, cold load pick-up 64REF, switch ON to fault (SOTF) 46 I2/I1, breaker failure 50BF, directional active underpower 37P, fault locator 21FL, recloser 79, phase undercurrent 37, excessive starting time, locked rotor 48/51LR, motor restart inhibition 66, capacitor overvoltage 59C, negative sequence overcurrent 46, overvoltage 59, undervoltage 27, positive sequence undervoltage 27P, earth fault overvoltage 59N, underfrequency 81/81N, rate of change of frequency 81R, synchro-check 25, lockout relay 86, CT supervision 60, VT supervision 60, H2 detection 68H2, H5 detection 68H5, negative sequence overcurrent 47, programmable stages 99, programmable curve
    • Protective Treatment : conformal coating conforming to IEC 60068-2-52:Kb/1, conformal coating conforming to IEC 60068-2-60:Ke, conformal coating conforming to IEC 60721-3-3:3C2
    • Software Name : EcoStruxure Power Device virtual simulation test, eSetup Easergy Pro
    • Switchgear Diagnosis Type : CT/VT supervision 60, CT supervision, trip circuit supervision TCS
    • Type Of Measurement : voltage zero sequence, voltage positive sequence, voltage negative sequence, voltage ratio of negative and positive, voltage phasor diagram view, current phasor diagram view, voltage 2nd, 15th harmonics with THDcurrent 3-phase, current zero sequence, current positive sequence, current negative sequence, current ratio of negative and positive, voltage phase to earth, voltage phase to phase, short circuit fault reactance negative sequence, fault location current phasor diagram view, earth fault reactance, frequency, active power, RMS active power, reactive power, RMS reactive power, apparent power, RMS apparent power, active energy, reactive energy, cos φ, tan φ, power angle, power factor, current 2nd, 15th harmonics with THD, voltage interruption, condition monitoring CB wear
    • [Us] Rated Supply Voltage : 48...230 V AC/DC, 48...250 V DC
    • Connections - Terminals : ring lugs (voltage transformer)screw removable (digital input/output), ring lugs removable (current transformer), pin removable (voltage transformer)
    • Carbon Footprint Of The Distribution Phase [A4] : 0.580604602, 0.6 kg CO2 eq.
    • Carbon Footprint Of The End-of-life Phase [C1 To C4] : 2 kg CO2 eq., 2.1163418643
    • Carbon Footprint Of The Installation Phase [A5] : 0.0528905846, 0.1 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase [A1 To A3] : 171 kg CO2 eq., 171.1458088753
    • Carbon Footprint Of The Use Phase [B2, B3, B4, B6] : 229 kg CO2 eq., 228.549
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-06-03
    • Return Indicator : N
    • Stocking Flag : Y
    • Stock Policy : 2
    • Device Type : Relay, Control & Measurement - Protection relay
    • Serviceability : Yes
    • Traceability : Yes
    • Field Service Division : DPIBS
    • Average Life Duration : 15 year(s)
    • Use Carbon Footprint : 228.549
    • Weee Scope : Out
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI1901010_V2
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : No
    • Rohs Eur Status : Compliant By Exemption
    • Rohs Eur Conformity Date : 2435
    • Rohs Eur Full Compliance Status : Compliant By Exemption
    • China Rohs In Scope : Yes
    • China Rohs Label : 4
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : No
    • Product Contributes To Saved And Avoided Emissions : No
    • Product Kit Identifier : N
    • Arc Flash Protection : no
    • Device Short Name : P5M30-CECE-GAAAH-BAFK
    • Display Type : LCD 128 x 64 pixels with single line diagram
    • Mounting Mode : withdrawable
    • Mounting Support : rack
    • Number Of Key : 2 customizable
    • Operating Threshold : 24...230 V AC/DC
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Or Component Type : protection and control relay
    • Range Of Product : PowerLogic P5
    • Relay Application : universal
    • Returnability : No
    • Setting : 4
    • Single Line Diagram : 4 controlled + 8 displayed
    • Software Version : EIME v5.6.0.1
    • Sustainable Packaging : No
    • Time Synchronisation Protocol : SNTP
    • Total Lifecycle Carbon Footprint : 402 kg CO2 eq.
    • Web Server : embedded HTTP server
    • Pep Code : ENVPEP1901010EN
    • Database Version : 2016-11
    • Pep Verification Date : 2022-08-01
    • Pcr Version : PCR-ed3-EN-2015 04 02
    • Psr Version : PSR-0005-ed2-EN-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
    • Data Source : extrapolated product
    • Functional-unit Description : Protect distribution and transmission networks and high voltage equipment (typically from 1 to 500 KV) like feeder, transformer, motor and generator against faults, (short circuit, over load …) 24h per day, 7 days on 7.& 10Calculations done in this document for LCA use a period of 10 years of operations, in Europe environmental conditions. This time is not representative of the effective lifetime of PowerLogic P5 protection relays, which is more than 10 years.
    • Functional-unit Quantity : 1
    • Functional-unit Unit : unit
    • Reference Lifetime, In Y : 10
    • Energy Consumption On Product Lifetime, In Kwh : 466.47
    • Energy Model - Manufacturing [A1-a3] : Energy model used: France
    • Energy Model - Installation [A5] : Electricity mix; AC; < 1kV; EU-27
    • Energy Model - Use [B6] : Electricity mix; AC; < 1kV; EU-27
    • Energy Model - End Of Life [C1-c4] : Electricity mix; AC; < 1kV; EU-27
    • Recyclability Potential, In % : 27
    • Height Nominal : 169.5 mm
    • Height Useful : 169.5 mm
    • Width Nominal : 170 mm
    • Width Real : 170 mm
    • Certificate Agency : IEC
    • Nbr. Of Units In Pkg. : 1
    • Package Weight(Lbs) : 4.5 kg
    • Take-back : No
    • Warranty (In Months) : 24
    • Global Warming (Kg.Equivalent.Co2) Operational Energy Use [B6] : 228.549
    • Total Use Of Renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Operational Energy Use [B6] : 580.425
    • Use Of Renewable Primary Energy, Excluding Renewable Primary Energy Resources Used As Raw Materials (Mj) Operational Energy Use [B6] : 580.425
    • Customs Code : 9027504060
  • Environment Attributes Main
    • Ambient Air Temperature For Operation : -40-65 °C 16 h ), -40-65 °C 16 h ), -40-70 °C 96 h ), -40-70 °C 96 h )-40-65 °C 16 h ), -40-65 °C 16 h ), -40-70 °C 96 h )
    • Relative Humidity : 0-95 % at 40-40 °C, without condensation, 56 days, 93-95 % at 25-55 °C, 6 cycles, 12 + 12 hours
    • Take Back : No
    • Recycled Metal Content At Cr Level : 0 %
    • China Rohs Regulation : X
    • Mercury Free : Yes
    • Carbon Footprint : 402.4446459263
    • Ambient Air Temperature For Storage : -40-70 °C-40-70 °C
    • Circularity Profile : ENVEOLI1901010_V2
    • Environmental Disclosure : ENVPEP1901010EN
    • Eu Rohs Directive : Compliant By Exemption
    • Ip Degree Of Protection : IP54 IEC 60529
    • Operating Altitude : 6561.68 ft (2000 m)
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : No
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP1901010EN
    • Pep Verification Date : 2022-08-01
    • Pcr Version : PCR-ed3-EN-2015 04 02
    • Psr Version : PSR-0005-ed2-EN-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Product Or Component Type : protection and control relay
    • Range Of Product : PowerLogic P5
  • Output Attributes
    • Number Of Outputs : 1 watchdog, 8 watchdog
    • Analogue Output Number : 0
  • Contractual Warranty Attributes
    • Warranty Period : up to 10 years (Standard warranty 2 years. Please check with your local SE representative for extended warranty availability and conditions))
    • Warranty : up to 10 years (Standard warranty 2 years. Please check with your local SE representative for extended warranty availability and conditions))
  • Input Attributes
    • Input Type : 3 1/5 A CT phase current, 1 1/5 A CT residual current, 4 100 V/110 V VT voltage, 4 voltage, 31 digital
    • Analogue Input Number : 0
    • Digital Input Number : 16
  • Specifications
    • Country of Origin : Latvia
    • Height : 6.67 in
    • Width : 6.69 in
    • Depth : 205 mm