PowerLogic™ ION9000 meter, DIN mount, Low Voltage input current, 192 mm display, B2B adapter, HW kit

POWERLOGIC� ION9000 METER, DIN

SQDMETSEION93040 METSEION93040 SQDMETSEION93040
15205.68 / EA
http://schema.org/OutOfStock
  • Depth: 135.3 mm
  • Display Type: Remote LCD Display, Colour Touchscreen
  • IsSustainable: Yes
  • Number of Outputs: 4 Digital, 2 Form C Relay Output
The PowerLogic ION9000 is your 24/7 power quality expert, providing information, not just data. A comprehensive, industry-leading Power Quality Instrument (PQI-A) certified to IEC 62586-1/-2 ensures reliable, precision performance that is perfect for both supply and demand side applications. Third-party lab verified accuracy to Class 0.1S (ANSI C12.20, IEC 62053-22). Highly customizable and modular, ION technology programmability and field installable option modules can satisfy any solution, protecting your investment now and into the future. Providing power quality analysis according to both EN 50160 and IEEE 519, and patented Disturbance Direction Detection, you become a PQ expert and will be able to respond rapidly to system events. Cybersecurity features include secure protocols (HTTPS, SFTP), security event logging, Syslog protocol, ability to enable/disable communication ports, and 50 user configurable accounts. With 2 GB of memory to support 50 data logs, 50+ user-definable alarms, disturbance and transient waveforms. 1/2 cycle RMS logging, custom web pages, min/max logs, energy trends, and Time of Use. The ability to timestamp events to +/-1 ms utilizing time synchronization method that include PTP (IEEE1588), NTP, IRIG-B, GPS ASCII (RS485) and network time set function. 8 digital inputs, 4 digital outputs and 2 relay outputs, plus the ability to add up to 4 option modules. Option modules include 2 relays and 6 digital inputs or 2 analog outputs and 4 analog inputs. Ability to capture power quality events as short as 20 µs and record both waveforms and 1/2-cycle RMS concurrently on any event. Voltage inputs of 100 to 690 V between phases; Current inputs with low voltage transducer; Frequency of 20-450 Hz. Wide control power range of 90 to 480 VAC or 110 to 480 VDC. DIN rail mounting with remote display and panel mounting (with back to back adapter), plus 2 display options, further enhance the flexibility and adaptability of the ION9000.
QTY
  • Features
  • Specifications
  • Features
    • Fast access to timely, critical information for energy, electrical network, and asset management
    • Help operations personnel avoid downtime by making power quality understandable
    • Makes energy and power quality actionable to support your op and sustainability goals
    • More detailed PQ compliance reporting, and expertlevel power quality and rootcause analytics
    • Forecasting to help ensure your electrical system avoid overloads, unbalances or high peak demand
    • Ensure energy efficiency and optimized costs by understanding how energy is being consumed
    • Perform subbilling or allocate cost to encourage energyefficient behavior, reduce PF penalities
    • Support participation in demand response or variable tariff (TOU, RTP) programs
    • Maximize use of capacity by performing load studies and infrastructure expansion planning
    • Patented ION Programming allows for full alarm/calc customization, control and more
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Communications & Management Attributes
    • Communication Port Protocol : Modbus RTU 2400...115200 bps - 2-wire, ION 2400...115200 bps - 2-wire, DNP3 2400...115200 bps - 2-wire, Modbus TCP 10/100 Mbit/s, ION TCP 10/100 Mbit/s, DNP3 TCP 10/100 Mbit/s, IEC 61850, Ethernet Modbus TCP/IP daisy chain 10/100 Mbit/s, DHCP, DNS, DLMS
    • Communication Service : compliant reports, power quality summary, energy report, EcoStruxure Power Events Analysis, SMTP e-mail notification, SNMP
    • Communication Port Support : 2 RS485 removable screw terminal block
    • Communication Gateway : Ethernet/serial
  • Conformance Attributes
    • Standards : ANSI C12.20, ANSI C37.90.1, IEC 61000-4-15, IEC 61000-4-30, IEC 61010-1, IEC 61326-1, IEC 61557-12, IEC 61850, IEC 62052-11, IEC 62052-31, IEC 62053-22, IEC 62053-23, IEC 62053-24, IEC 62586, UL 61010-1
  • Complementary Attributes
    • Maximum Power Consumption In Va : 80 VA 480 V AC
  • Important Information Attributes
    • Cybersecurity : Syslog protocol support, robust security logs, port hardening, enable/disable communication ports, hardware metrology lock
    • Data Recording : time stamping, min/max of instantaneous values, user-definablecontinuous logging or snapshot, trending/forecasting, event logs, alarm logs, configuration change, power outage, user login/logout, data logs, GPS synchronisation, sequence of event recording
    • Device Application : power monitoring, WAGES metering, Net metering, medium voltage, high voltage
    • Display Type : remote LCD display, colour touchscreen
    • Electromagnetic Compatibility : EMC immunity conforming to IEC 62052-11, EMC immunity conforming to IEC 61326-1, EMC immunity conforming to IEC 61000-6-5, electrostatic discharge immunity test conforming to IEC 61000-4-2, immunity to radiated fields conforming to IEC 61000-4-3, immunity to fast transients conforming to IEC 61000-4-4, surge immunity test conforming to IEC 61000-4-5, immunity to conducted disturbances conforming to IEC 61000-4-6, immunity to magnetic fields at network frequency conforming to IEC 61000-4-8, immunity to conducted disturbances - test level: 2...150 kHz conforming to CLC/TR 50579, voltage dips and interruptions immunity test conforming to IEC 61000-4-11, immunity to impulse waves conforming to IEC 61000-4-12, conducted and radiated emissions conforming to EN 55011, conducted and radiated emissions class B conforming to EN 55032, conducted and radiated emissions class B conforming to FCC part 15, conducted and radiated emissions class B conforming to ICES-003, surge withstand conforming to ANSI C37.90.1, surge withstand conforming to IEEE C37.90.1
    • Ethernet Service : DHCP client, Device Profile Web Services (DPWS), Rapid Scanning Tree Protocol (RSTP), FTP/HTTP/HTTPS
    • Market Segment : data center, healthcare, semiconductor, pharmaceutical, chemical, energy, mining
    • Measurement Accuracy : voltage +/- 0.1 %, current +/- 0.1 %
    • Measurement Voltage : 57-400 V AC 42...69 Hz between phase and neutral, 100-690 V AC 42...69 Hz between phases
    • Mounting Support : DIN rail meter device, door cut-out remote display
    • Network Frequency : 50 Hz, 60 Hz
    • Power Quality Analysis : IEEE 519 compliance reporting, EN 50160 compliance checking, IEEE 519 harmonic limit, IEC 61000-4-30 class A compliance reporting, waveform capture, total demand distortion, total harmonic distortion, up to the 63rd harmonic, up to the 127th harmonic with software, disturbance direction detection, dip, swell and transient, half cycle data acquisition, transient detection (20 µs)
    • Provided Equipment : remote display, remote display adapter, mounting instructions, Mounting Hardware
    • Quality Labels : ISO 9001, ISO 14000
    • Type Of Measurement : apparent power per phase, power factor per phase, voltage sags and swells, current sags and swells, voltage, current, frequency, active and reactive power total, apparent power total, active and reactive power per phase, power factor total, active and reactive energy, apparent energy, harmonic distortion (I THD & U THD)
    • Web Services : viewing of captured waveform, web page, pass/fail report for IEEE 519, pass/fail report for EN 50160, ITIC (CBEMA) curve, SEMI curve, NEMA motor derating curve, alarm notification by e-mail, TLS 1.2, push historical data via mail
    • Us Rated Supply Voltage2 : 90...480 V AC 45...66 Hz +/- 10 %, 90...120 V AC 400 Hz +/- 10 %, 110...480 V DC +/- 10 %
    • Carbon Footprint Of The Distribution Phase A4 : 2.046440319308898, 2 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 7 kg CO2 eq., 6.65757678679156
    • Carbon Footprint Of The Installation Phase A5 : 2.173543325025806, 2 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 250 kg CO2 eq., 249.93315245923222
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 603 kg CO2 eq., 602.9313330204241
    • Isolation Voltage : III400-690 V conforming to EN 61010-1:ed. 3, III347-600 V conforming to UL 61010-1:ed. 3, III347-600 V conforming to CSA C22.2 No 61010-1:ed. 3
    • Metering Type : demand current I1, I2, I3, I4, I5, peak demand currents, demand power P, Q, S, peak demand power PM, QM, SM, calculated active and reactive energy (+/- W.h, +/- VAR.h)
    • Ride Through Time : 100 ms 6 cycles at 60 Hz 120 V AC typical, 400 ms 24 cycles at 60 Hz 240 V AC typical, 1200 ms 72 cycles at 60 Hz 480 V AC typical
    • Time Synchronisation Protocol : GPS, IRIG-B, NTP, SNTP, PTP
    • Us Rated Supply Voltage5 : 90...480 V AC 45...66 Hz +/- 10 %, 90...120 V AC 400 Hz +/- 10 %, 110...480 V DC +/- 10 %
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-07-10
    • Device Type : Relay, Control & Measurement - measuring, monitoring device
    • Serviceability : Yes
    • Field Service Division : DPIBS
    • Legacy WEEE Scope : In
    • Scope Perimeter : At least in Europe
    • EOLI Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI1801009EN
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • ROHS EUR In Scope : Yes
    • ROHS EUR Status : Compliant with Exemptions
    • ROHS EUR Full Compliance Status : Compliant with Exemptions
    • ROHS EUR Full Compliance Status Id : COMPLIANT_WITH_EXEMPTIONS
    • China ROHS In Scope : Yes
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : No
    • Product Contributes To Saved And Avoided Emissions : No
    • Return Indicator : Y
    • Device Short Name : ION93040
    • Display Resolution : 800 x 480 pixels
    • Electrical Insulation Class : class III EN/IEC 62052-11
    • Energy Efficiency Optimized : False
    • Frequency Measurement Range : 20-450 Hz
    • Memory Capacity : 2 GB
    • Package Weight Lbs : 3.6 kg
    • Poles Description : 3P + N + E
    • Port Ethernet : 10/100BASE-TX 2 RJ45
    • Power Consumption In VA : 38 VA 480 V AC
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Or Component Type : energy and power quality meter
    • Range : PowerLogic
    • Returnability : Yes
    • Sampling Rate : 1024 samples/cycle
    • Sustainable Packaging : No
    • Tamperproof Of Settings : protected by sealable cover
    • Total Lifecycle Carbon Footprint : 864 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Medium Desc : PowerLogic™ ION9000 meter, DIN mount, Low Voltage input current, 192 mm display, B2B adapter, HW kit
    • Stocking Flag : Y
    • Product Kit Identifier : N
    • Pep Code : ENVPEP1801009EN
    • Database Version : 2024-01
    • Pep Verification Date : 2025-05-20
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent external review
    • Data Source : extrapolated product
    • Functional Unit Description : The functional unit for the PowerLogic™ ION9000T meter (METSEION95040) is to provide accurate power quality monitoring and energy metering for a period of 10 years, ensuring compliance with international power quality standards and delivering high-resolution data for energy management. This includes measuring voltage and current with an accuracy of +/- 0.1%, operating at a rated supply voltage of 90...480 V AC or 110...480 V DC, and consuming approximately 11 W in active mode. The meter's lifecycle encompasses raw material extraction, manufacturing, distribution, use phase (with 100% runtime), and end-of-life disposal or recycling, with a total energy consumption calculated based on continuous operation over 10 years. This comprehensive approach allows for a detailed assessment of the environmental impacts associated with the meter.
    • Functional Unit Unit : unit
    • Energy Model Manufacturing A1 A3 2 : Electricity Mix; Low voltage; 2020; Canada, CA
    • Energy Model Installation A5 2 : No energy used
    • Energy Model Use B6 2 : Electricity Mix; Low voltage; 2020; United States, US
    • Energy Model End Of Life C1 C4 2 : Global
    • Installation Category : III
    • Global Commercial Status : Commercialised
    • Product Name : PowerLogic ION9000
  • Environment Attributes Main
    • Take Back : No, Nej
    • Ambient Air Temperature For Operation : -25-70 °C, -25-70 °C
    • EU ROHS Directive : Compliant By Exemption , Compliant with Exemptions
    • IP Degree Of Protection : IP65 front:, IP30 rear:
    • ROHS Exemption Information : Yes
    • Recycled Metal Content At Cr Level : 0 %
    • China ROHS Regulation : X
    • Mercury Free : Yes
    • Carbon Footprint : 863.7420459107825
    • Ambient Air Temperature For Storage : -40-85 °C
    • Circularity Profile : ENVEOLI1801009EN
    • Environmental Disclosure : ENVPEP1801009EN
    • Operating Altitude : 0...9842.52 ft (0...3000 m)
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : No
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Relative Humidity : 5-95 %
    • Pep Code : ENVPEP1801009EN
    • Pep Verification Date : 2025-05-20
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent external review
  • General Attributes
    • Provided Equipment : remote display, remote display adapter, mounting instructions, Mounting Hardware
    • Product Or Component Type : energy and power quality meter
  • Output Attributes
    • Number Of Outputs : 4 digital, 2 form C relay output
  • Input Attributes
    • Analogue Input Type : voltage (impedance 5 MOhm), split core current transducer (impedance 200 kOhm)5 x
    • Number Of Inputs : 8 digital 30 V AC/60 V DC
  • Specifications
    • Depth : 135.3 mm