Power quality meter, PowerLogic ION7400, Standard, transducer, 512 MB, 256 s/c

POWERLOGIC ION7410 LV DC - DIN

SQDMETSEION7413 METSEION7413 SQDMETSEION7413
0.00 / EA
http://schema.org/OutOfStock
  • Depth: 90.8 mm
  • Number of Outputs: 1 Pulse
PowerLogic ION7400 utility feeder power meters combine capabilities not typically available in compact meters. They offers a hight flexibility and usability, along with accurate 3-phase energy and power measurements with data logging. Use Power Monitoring Expert software for data analysis or share operation data with SCADA systems through multiple communication channels and protocols. Certified by third party labs for energy accuracy (IEC 62052-11, IEC 62052-22, IEC 62052-24) and power quality (IEC 62586-2, IEC 61000-4-30 Class S). Cybersecurity features include secure protocols (HTTPS, SFTP), security event logging, Syslog protocol. Ability to enable/disable communication ports, and 16 user configurable accounts. With 512 MB of memory to support 50 data logs, 50+ user-definable alarms, waveform captures, 1/2 cycle RMS logging, custom web pages, min/max logs, energy trends, and Time of Use. The ability to timestamp events to +/-1 ms utilizing time synchronization method that include PTP (IEEE1588), NTP, IRIG-B, GPS ASCII (RS485) and network time set function. 3 digital inputs and one digital output. I/O option modules include 2 relays and 6 digital inputs or 2 analog outputs and 4 analog inputs. Wide control power range of 20-60 VDC. Operating environment of -25 to +70C; Humidity rating of 5% to 95%; Altitude up to 3000 m. DIN rail mounting (no display).
QTY
  • Features
  • Specifications
  • Prop 65
    • WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
  • Communications & Management Attributes
    • Communication Port Protocol : Modbus RTU 115 kbauds - 2-wire, ION 115 kbauds - 2-wire, DNP3, IEC 61850, Modbus TCP/IP, Ethernet Modbus TCP/IP daisy chain 10/100 Mbit/s, RSTP 801.1d 2004, DLMS
    • Communication Port Support : ETHERNET, screw terminal block RS485, mini B USB USB
    • Communication Service : NTP time synchronization, SMTP e-mail notification, RSTP support, DHCP, SNMP, PTP time synchronization
    • Communication Network Type : IPv6 (internet protocol)
  • Complementary Attributes
    • Line Rated Current : 10 A, 1 A, 5 A
    • Us Rated Supply Voltage : 20...60 V DC +/- 10 %
  • Important Information Attributes
    • Cybersecurity : enable/disable communication ports, robust security logs, port hardening, password protection, Syslog protocol support
    • Data Recording : sequence of event recording, trending/forecasting, harmonics logs, time stamping, GPS synchronisation, waveform logs, min/max of instantaneous values, sag and swell logs, data logs, event logs, alarm logs, 50 data recorders
    • Device Application : WAGES metering, power monitoring, data aggregation, revenue billing
    • Electromagnetic Compatibility : electrostatic discharge conforming to IEC 61000-4-2, radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3, electrical fast transient/burst immunity test conforming to IEC 61000-4-4, surge immunity test conforming to IEC 61000-4-5, conducted RF disturbances conforming to IEC 61000-4-6, magnetic field at power frequency conforming to IEC 61000-4-8, voltage dips and interruptions immunity test conforming to IEC 61000-4-11, immunity to impulse waves conforming to IEC 61000-4-12, conducted and radiated emissions conforming to EN 55022, conducted and radiated emissions conforming to EN 55011, conducted and radiated emissions conforming to FCC part 15, conducted and radiated emissions conforming to ICES-003, conducted RF disturbances (2...150 Hz) conforming to CLC/TR 50579, surge withstand conforming to IEEE C37.90.1
    • Information Displayed : voltage, current, frequency, power, energy consumption, harmonic distortion
    • Isolation Voltage : III400-690 V conforming to IEC 61010-1:ed. 3, III400-690 V conforming to EN 61010-1:ed. 3, III347-600 V conforming to UL 61010-1:ed. 3, III347-600 V conforming to CSA C22.2 No 61010-1:ed. 3
    • Measurement Accuracy : current +/- 0.1 %, voltage +/- 0.1 %, active energy +/- 0.2 %
    • Measurement Voltage : 57-400 V AC 42...69 Hz between phase and neutral, 100-690 V AC 42...69 Hz between phases
    • Mounting Support : DIN rail
    • Network Frequency : 50 Hz, 60 Hz
    • Poles Description : 1P + N, 3P, 3P + N
    • Power Quality Analysis : EN 50160 2010 compliance report, IEEE 519 2014 compliance report, IEC 61000-4-30 class S power quality measurement, up to the 63rd harmonic, harmonic distortion, waveform capture, voltage sag and swell detection, programmablity (logic and math functions), IEC 62586 power quality monitoring, IEC 61000-4-15 disturbance direction detection, rapid voltage change
    • Type Of Measurement : apparent power per phase, rms, power factor per phase, rmscurrent, voltage, frequency, active and reactive power total, apparent power total, power factor total, active and reactive power per phase, rms, active and reactive energy, apparent energy
    • Web Services : customizable home page, file upload/download via FTP, file upload/download via SFTP, web server, alarm notification by e-mail, viewing of captured waveform (FTP), viewing of captured waveform (web), HTTPS server
    • Carbon Footprint Of The Distribution Phase A4 : 0.6920075596561817, 0.7 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 2 kg CO2 eq., 1.8454293882772015
    • Carbon Footprint Of The Installation Phase A5 : 0.5434712530089375, 0.5 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 39 kg CO2 eq., 38.65040676622675
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 203 kg CO2 eq., 202.64310837690203
    • Certificate Agency : CE, cULus, N998
    • Other Technical Guide : https://download.schneider-electric.com/files?p_Doc_Ref=PLSED310113EN&p_File_name=PLSED310113EN_Web.pdf, PLSED310113EN
    • Local Data Status : Publishable
    • Local Publishable Date : 2026-03-10
    • Return Indicator : N
    • Stocking Flag : Y
    • Stock Policy : 2
    • Device Type : Relay, Control & Measurement - measuring, monitoring device
    • Serviceability : Yes
    • Traceability : Yes
    • Field Service Division : DPIBS
    • Weee Scope : In
    • Weee Product Category : 5
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI1512006EN
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : Yes
    • Rohs Eur Status : Compliant By Exemption
    • Rohs Eur Conformity Date : 2333
    • Rohs Eur Full Compliance Status : Compliant By Exemption
    • China Rohs In Scope : Yes
    • China Rohs Label : 7
    • With Recycled Cardboard : No
    • Without Single Use Plastic : No
    • Product Contributes To Saved And Avoided Emissions : No
    • Dangerous Goods Code : LITHIUM METAL BATTERIES IN EQUIP. BUTTON CELL-BAT EXEMPT
    • Product Kit Identifier : N
    • Device Short Name : ION7413
    • Display Type : Without Display
    • Energy Efficiency Optimized : False
    • Frequency Measurement Range : 42-69 Hz
    • Installation Category : III
    • Measurement Current : 50-10000 mA
    • Memory Capacity : 512 MB
    • Mounting Mode : clip-on
    • Power Consumption In W : 17 W
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Name : PowerLogic ION7400
    • Product Or Component Type : power meter
    • Range : PowerLogic
    • Returnability : No
    • Sampling Rate : 256 samples/cycle
    • Software Version : v6.3.2-2
    • Sustainable Packaging : No
    • Total Lifecycle Carbon Footprint : 244 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Warranty In Months : 18
    • Pep Code : ENVPEP1406022_V2
    • Database Version : 2025-04
    • Pep Verification Date : 2025-11-28
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent external review
    • Data Source : extrapolated product
    • Functional-unit Description : The functional unit of the PowerLogic PM8000 series is a high-precision power and energy meter designed for advanced monitoring and analysis. It operates with a low power consumption of 4.7 W in active mode and supports 100% runtime, with a total energy consumption of 411.72 kWh for active components for 10 years. It features robust cybersecurity with secure protocols (HTTPS, SFTP), Syslog support, and 50 configurable user accounts. With 512 MB memory, it supports 50 data logs, waveform captures, alarms, energy trends, and custom web pages. It offers precise event timestamping to ±1 ms using PTP, NTP, IRIG-B, GPS, and network time sync. The device includes 3 digital inputs, 1 digital output, and supports up to 4 I/O modules (relays, analog/digital I/Os). It operates in harsh environments (-25 to +70°C, 5–95% humidity, up to 3000 m altitude) and mounts via DIN rail with optional remote display.
    • Functional-unit Quantity : 1
    • Functional-unit Unit : unit
    • Reference Lifetime, In Y : 10
    • Energy Consumption On Product Lifetime, In Kwh : 411.72
    • Energy Model - Manufacturing [A1-a3] : Electricity Mix; Low voltage; 2020; Canada, CA
    • Energy Model - Installation [A5] : No energy used
    • Energy Model - Use [B6] : Electricity Mix; Low voltage; 2020; United States, US
    • Energy Model - End Of Life [C1-c4] : Global, European and French datasets are used.
    • Recyclability Potential, In % : 12
    • Offer Owner Code : 190781
    • Pn : 1
    • Height Nominal : 90.5 mm
    • Width Nominal : 90.5 mm
  • Environment Attributes Main
    • Ambient Air Temperature For Storage : -40-85 °C, -40-85 °C
    • Ip Degree Of Protection : IP30 conforming to IEC 60529
    • Relative Humidity : 5-95 %
    • Take Back : No
    • Recycled Metal Content At Cr Level : 0 %
    • China Rohs Regulation : X
    • Carbon Footprint : 244.37442334407112
    • Ambient Air Temperature For Operation : -25-70 °C-25-70 °C
    • Circularity Profile : ENVEOLI1512006EN
    • Environmental Disclosure : ENVPEP1406022_V2
    • Eu Rohs Directive : Compliant By Exemption
    • Operating Altitude : 9842.52 ft (3000 m)
    • Packaging Made With Recycled Cardboard : No
    • Packaging Without Single Use Plastic : No
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP1406022_V2
    • Pep Verification Date : 2025-11-28
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent external review
  • General Attributes
    • Product Or Component Type : power meter
  • ETIM
    • ETIM 8 : EC002301
    • ETIM 9 : EC002301
  • Output Attributes
    • Number Of Outputs : 1 pulse
  • Input Attributes
    • Analogue Input Type : voltage (impedance 5 MOhm), current (impedance 0.3 mOhm)
    • Number Of Inputs : 3 digital 30 V AC, 3 digital 60 V DC
  • Specifications
    • Country of Origin : Brazil, Canada, France, Sweden, United States
    • Depth : |90.8 mm