SQUARE D

Power quality meter, PowerLogic PM8000, Advanced, transducer, 512MB, 512s/c

Power quality meter, PowerLogi

SQDMETSEPM8343 METSEPM8343 3606486874769
22637.48 / EA
http://schema.org/OutOfStock
  • Country of Origin: Canada
  • Depth: 90.8 mm
  • Number of Outputs: 1 Pulse
QTY
  • Specifications
  • Communications & Management Attributes
    • Communication Port Protocol : Modbus RTU 115 kbauds - 2-wire, ION 115 kbauds - 2-wire, DNP3, IEC 61850, Modbus TCP/IP, Ethernet Modbus TCP/IP daisy chain 10/100 Mbit/s, RSTP 801.1d 2004
    • Communication Port Support : ETHERNET, screw terminal block RS485
    • Communication Service : SMTP e-mail notification, DHCP, RSTP support, NTP time synchronization, PTP time synchronization
    • Communication Network Type : IPv6 (internet protocol)
  • Complementary Attributes
    • Line Rated Current : 1 A, 10 A, 5 A
  • Important Information Attributes
    • Cybersecurity : password protection, port hardening, enable/disable communication ports, robust security logs, Syslog protocol support
    • Data Recording : harmonics logs, sag and swell logs, GPS synchronisation, time stamping, data logs, trending/forecasting, waveform logs, alarm logs, sequence of event recording, min/max of instantaneous values, event logs, 64 data recorders
    • Device Application : WAGES metering, power monitoring
    • Electromagnetic Compatibility : electrostatic discharge conforming to IEC 61000-4-2, radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3, electrical fast transient/burst immunity test conforming to IEC 61000-4-4, surge immunity test conforming to IEC 61000-4-5, conducted RF disturbances conforming to IEC 61000-4-6, magnetic field at power frequency conforming to IEC 61000-4-8, voltage dips and interruptions immunity test conforming to IEC 61000-4-11, immunity to impulse waves conforming to IEC 61000-4-12, conducted and radiated emissions conforming to EN 55022, conducted and radiated emissions conforming to EN 55011, conducted and radiated emissions conforming to FCC part 15, conducted and radiated emissions conforming to ICES-003, conducted RF disturbances (2...150 Hz) conforming to CLC/TR 50579, surge withstand (2...150 Hz) conforming to IEEE C37.90.1
    • Information Displayed : voltage, current, frequency, power, energy consumption, harmonic distortion
    • Isolation Voltage : III400-690 V conforming to IEC 61010-1:ed. 3, III400-690 V conforming to EN 61010-1:ed. 3, III347-600 V conforming to UL 61010-1:ed. 3, III347-600 V conforming to CSA C22.2 No 61010-1:ed. 3
    • Market Segment : buildings large building network management: main incomer, buildings large building network management: sub feeder, buildings multi-site network management: sub feeder, data center large building network management: sub feeder, healthcare network management: sub feeder, industry network management: sub feederbuildings large building cost management: billing: sub feeder, buildings small building network management: main incomer, buildings medium building network management: main incomer, buildings multi-site network management: main incomer, data center medium building network management: main incomer, healthcare multi-site network management: main incomer, industry network management: main incomer, utility network management: sub feeder
    • Measurement Accuracy : current +/- 0.1 %, voltage +/- 0.1 %, active energy +/- 0.2 %
    • Measurement Voltage : 57-400 V AC 42...69 Hz between phase and neutral, 100-690 V AC 42...69 Hz between phases
    • Network Frequency : 50 Hz, 60 Hz
    • Number Of Poles : 1P + N, 3P + N, 3P
    • Power Quality Analysis : EN 50160 2010 compliance report, IEEE 519 2014 compliance report, IEC 61000-4-30 class A power quality measurement, IEC 61000-4-15 up to the 63rd harmonic, harmonic distortion, waveform capture, voltage sag and swell detection, IEEE 519 2014 programmablity (logic and math functions), IEC 62586 power quality monitoring, disturbance direction detection, IEC 61000-4-15 flicker, rapid voltage change
    • Type Of Measurement : active and reactive power per phase, rms, apparent power per phase, rms, power factor per phase, rmscurrent per phase, rms, voltage, frequency total, active and reactive power total, apparent power total, power factor total
    • Web Services : customizable home page, file upload/download via FTP, file upload/download via SFTP, web server, alarm notification by e-mail, viewing of captured waveform (FTP), viewing of captured waveform (web), HTTPS server
    • Certificate Agency : CE, cULus, N998
    • [Us] Rated Supply Voltage : 90...415 V AC 45...65 Hz +/- 10 %, 110...415 V DC +/- 10 %
    • Carbon Footprint Of The Distribution Phase [A4] : 0.5737616077149312, 0.6 kg CO2 eq.
    • Carbon Footprint Of The End-of-life Phase [C1 To C4] : 2 kg CO2 eq., 1.530093881154107
    • Carbon Footprint Of The Installation Phase [A5] : 0.45060626220352684, 0.5 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase [A1 To A3] : 32 kg CO2 eq., 32.04606541588121
    • Carbon Footprint Of The Use Phase [B2, B3, B4, B6] : 203 kg CO2 eq., 202.64310837690203
    • Other Technical Guide : https://download.schneider-electric.com/files?p_Doc_Ref=PLSED310058EN&p_File_name=PLSED310058EN_Web.pdf, PLSED310058EN
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-12-02
    • Return Indicator : Y
    • Stocking Flag : Y
    • Device Type : Relay, Control & Measurement - measuring, monitoring device
    • Serviceability : No
    • Weee Scope : In
    • Weee Product Category : 5
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI1406022EN
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : Yes
    • Rohs Eur Status : Compliant By Exemption
    • Rohs Eur Conformity Date : 2345
    • Rohs Eur Full Compliance Status : Compliant By Exemption
    • China Rohs In Scope : Yes
    • China Rohs Label : 7
    • With Recycled Cardboard : No
    • Without Single Use Plastic : No
    • Product Contributes To Saved And Avoided Emissions : No
    • Dangerous Goods Code : LITHIUM METAL BATTERIES IN EQUIP. BUTTON CELL-BAT EXEMPT
    • Product Kit Identifier : N
    • Compatibility Code : PM8243
    • Device Short Name : PM8343
    • Display Type : Without Display
    • Energy Efficiency Optimized : False
    • Frequency Measurement Range : 42-69 Hz
    • Installation Category : III
    • Measurement Current : 50-10000 mA
    • Memory Capacity : 512 MB
    • Mounting Mode : clip-on
    • Mounting Support : DIN rail
    • Power Consumption In Va : 16 VA 230 V AC
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Name : PowerLogic PM8000
    • Product Or Component Type : power meter
    • Range : PowerLogic
    • Returnability : Yes
    • Sampling Rate : 512 samples/cycle
    • Software Version : v6.3.2-2
    • Sustainable Packaging : No
    • Total Lifecycle Carbon Footprint : 237 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Pep Code : ENVPEP1406022_V2
    • Database Version : 2025-04
    • Pep Verification Date : 2025-11-28
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent external review
    • Data Source : extrapolated product
    • Functional-unit Description : The functional unit of the PowerLogic PM8000 series is a high-precision power and energy meter designed for advanced monitoring and analysis. It operates with a low power consumption of 4.7 W in active mode and supports 100% runtime, with a total energy consumption of 411.72 kWh for active components for 10 years. It features robust cybersecurity with secure protocols (HTTPS, SFTP), Syslog support, and 50 configurable user accounts. With 512 MB memory, it supports 50 data logs, waveform captures, alarms, energy trends, and custom web pages. It offers precise event timestamping to ±1 ms using PTP, NTP, IRIG-B, GPS, and network time sync. The device includes 3 digital inputs, 1 digital output, and supports up to 4 I/O modules (relays, analog/digital I/Os). It operates in harsh environments (-25 to +70°C, 5–95% humidity, up to 3000 m altitude) and mounts via DIN rail with optional remote display.
    • Functional-unit Quantity : 1
    • Functional-unit Unit : unit
    • Reference Lifetime, In Y : 10
    • Energy Consumption On Product Lifetime, In Kwh : 411.72
    • Energy Model - Manufacturing [A1-a3] : Electricity Mix; Low voltage; 2020; Canada, CA
    • Energy Model - Installation [A5] : No energy used
    • Energy Model - Use [B6] : Electricity Mix; Low voltage; 2020; United States, US
    • Energy Model - End Of Life [C1-c4] : Global, European and French datasets are used.
    • Recyclability Potential, In % : 12
    • Height Nominal : 90.5 mm
    • Width Nominal : 90.5 mm
    • Nbr. Of Units In Pkg. : 1
    • Package Weight(Lbs) : 854.000 g
    • Take-back : No
    • Warranty (In Months) : 18
    • Use Of Renewable Primary Energy Resources Used As Raw Materials (Mj) Benefits/Loads Beyond System Boundaries [D] : 2.6586
  • Environment Attributes Main
    • Ambient Air Temperature For Storage : -40-85 °C, -40-85 °C
    • Take Back : No
    • Recycled Metal Content At Cr Level : 0 %
    • China Rohs Regulation : X
    • Carbon Footprint : 237.2436355438558
    • Ambient Air Temperature For Operation : -25-70 °C-25-70 °C
    • Circularity Profile : ENVEOLI1406022EN
    • Environmental Disclosure : ENVPEP1406022_V2
    • Eu Rohs Directive : Compliant By Exemption
    • Ip Degree Of Protection : IP30 conforming to IEC 60529
    • Operating Altitude : 9842.52 ft (3000 m)
    • Packaging Made With Recycled Cardboard : No
    • Packaging Without Single Use Plastic : No
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Relative Humidity : 5-95 %
    • Pep Code : ENVPEP1406022_V2
    • Pep Verification Date : 2025-11-28
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent external review
  • General Attributes
    • Product Or Component Type : power meter
  • ETIM
    • ETIM 8 : EC002301
    • ETIM 9 : EC002301
  • Output Attributes
    • Number Of Outputs : 1 pulse
  • Input Attributes
    • Analogue Input Type : voltage (impedance 5 MOhm), current (impedance 0.3 mOhm)
    • Number Of Inputs : 3 digital 30 V AC, 3 digital 60 V DC
  • Specifications
    • Country of Origin : Canada
    • Depth : 90.8 mm