SQUARE D

Power quality meter, PowerLogic ION7400, Essential, transducer, 64 MB, 128 s/c

Power quality meter, PowerLogi

SQDMETSEION7413E METSEION7413E 3606486995815
9091.41 / EA
http://schema.org/OutOfStock
  • Country of Origin: Canada
  • Depth: 90.8 mm
  • Number of Outputs: 1 Pulse
The PowerLogic ION7413E comes in a DIN Rail mount form factor with LVDC control power. It is designed to bring operational awareness and efficiency for your Utility Feeder applications in substation. With its modular, flexible, and power ION technology, you can build custom applications for each meter. It comes with revenue grade accuracy, multiple communication ports, and a color graphical display. Certified by third party labs for Class 0.2S energy accuracy (IEC62052-11, IEC62053-24, IEC62053-22). Cybersecurity features include secure protocols (HTTPs, sFTP, Secure ION), security event logging, Syslog protocol. Ability to enable/disable communication ports and support 50 configurable user account to help manage access. With 64MB of memory to support up to 10 data logs (160 channels), 50+ user-definable alarms, waveform captures upto 128 samples/cycle, 1/2 cycle RMS logging. The storage can also be used for custom web pages, min/max logs, energy trends, and Time of Use. The ability to timestamp events to +/-1ms utilizing time synchronization. Time synch method that include PTP (IEEE1588), NTP, IRIG-B, GPS ASCII (RS485) and network time set function. 3 digital inputs and one digital output, plus the ability to add up to 4 option modules. I/O option modules include 2 relays and 6 digital inputs or 2 analog outputs and 4 analog inputs Wide control power range of 20-60 VDC. Operating environment of -25 to +70°C; Humidity rating of 5% to 95%; Altitude up to 3000 m.
QTY
  • Product Description
  • Features
  • Specifications
The PowerLogic ION7413E comes in a DIN Rail mount form factor with LVDC control power. It is designed to bring operational awareness and efficiency for your Utility Feeder applications in substation. With its modular, flexible, and power ION technology, you can build custom applications for each meter. It comes with revenue grade accuracy, multiple communication ports, and a color graphical display. Certified by third party labs for Class 0.2S energy accuracy (IEC62052-11, IEC62053-24, IEC62053-22). Cybersecurity features include secure protocols (HTTPs, sFTP, Secure ION), security event logging, Syslog protocol. Ability to enable/disable communication ports and support 50 configurable user account to help manage access. With 64MB of memory to support up to 10 data logs (160 channels), 50+ user-definable alarms, waveform captures upto 128 samples/cycle, 1/2 cycle RMS logging. The storage can also be used for custom web pages, min/max logs, energy trends, and Time of Use. The ability to timestamp events to +/-1ms utilizing time synchronization. Time synch method that include PTP (IEEE1588), NTP, IRIG-B, GPS ASCII (RS485) and network time set function. 3 digital inputs and one digital output, plus the ability to add up to 4 option modules. I/O option modules include 2 relays and 6 digital inputs or 2 analog outputs and 4 analog inputs Wide control power range of 20-60 VDC. Operating environment of -25 to +70°C; Humidity rating of 5% to 95%; Altitude up to 3000 m.
  • Prop 65
    • WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
  • Communications & Management Attributes
    • Communication Port Protocol : Modbus RTU 115 kbauds - 2-wire, ION 115 kbauds - 2-wire, DNP3, IEC 61850, Modbus TCP/IPEthernet Modbus TCP/IP daisy chain 10/100 Mbit/s, RSTP 801.1d 2004, DLMS
    • Communication Service : NTP time synchronization, SMTP e-mail notification, RSTP support, DHCP, SNMP, PTP time synchronization
    • Communication Network Type : IPv6 (internet protocol)
    • Communication Port Support : ETHERNETscrew terminal block RS485mini B USB USB
  • Complementary Attributes
    • Line Rated Current : 10 A, 1 A, 5 A
  • Important Information Attributes
    • Cybersecurity : enable/disable communication ports, robust security logs, port hardening, password protection, Syslog protocol support
    • Data Recording : sequence of event recording, trending/forecasting, harmonics logs, time stamping, GPS synchronisation, waveform logs, min/max of instantaneous values, sag and swell logs, data logs, event logs, alarm logs, 10 data recorders
    • Device Application : revenue billing, WAGES metering, data aggregation, power monitoring
    • Electromagnetic Compatibility : electrostatic discharge conforming to IEC 61000-4-2radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3electrical fast transient/burst immunity test conforming to IEC 61000-4-4surge immunity test conforming to IEC 61000-4-5conducted RF disturbances conforming to IEC 61000-4-6magnetic field at power frequency conforming to IEC 61000-4-8voltage dips and interruptions immunity test conforming to IEC 61000-4-11immunity to impulse waves conforming to IEC 61000-4-12conducted and radiated emissions conforming to EN 55022, conducted and radiated emissions conforming to EN 55011, conducted and radiated emissions conforming to FCC part 15, conducted and radiated emissions conforming to ICES-003conducted RF disturbances (2...150 Hz) conforming to CLC/TR 50579surge withstand conforming to IEEE C37.90.1
    • Information Displayed : voltage, current, frequency, power, energy consumption, harmonic distortion
    • Isolation Voltage : III400-690 V conforming to IEC 61010-1:ed. 3, III400-690 V conforming to EN 61010-1:ed. 3III347-600 V conforming to UL 61010-1:ed. 3, III347-600 V conforming to CSA C22.2 No 61010-1:ed. 3
    • Measurement Accuracy : current +/- 0.1 %, voltage +/- 0.1 %active energy +/- 0.2 %
    • Network Frequency : 50 Hz, 60 Hz
    • Number Of Poles : 1P + N, 3P, 3P + N
    • Power Quality Analysis : EN 50160 2010 compliance reportIEEE 519 2014 compliance report, up to the 63rd harmonic, harmonic distortion, waveform capture, voltage sag and swell detection, programmablity (logic and math functions)IEC 62586 power quality monitoring
    • Type Of Measurement : active and reactive power per phase, rmsapparent power per phase, rmspower factor per phase, rmscurrent totalvoltage per phase, rms, frequency per phase, rms, active and reactive power total, apparent power total, power factor total, active and reactive energy, apparent energy total
    • Web Services : customizable home page, file upload/download via FTP, file upload/download via SFTP, web server, alarm notification by e-mail, viewing of captured waveform (FTP), viewing of captured waveform (web), HTTPS server
    • Certificate Agency : CE, cULus, N998
    • Carbon Footprint Of The Distribution Phase [A4] : 0.5737616077149312, 0.6 kg CO2 eq.
    • Carbon Footprint Of The End-of-life Phase [C1 To C4] : 2 kg CO2 eq., 1.530093881154107
    • Carbon Footprint Of The Installation Phase [A5] : 0.45060626220352684, 0.5 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase [A1 To A3] : 32 kg CO2 eq., 32.04606541588121
    • Carbon Footprint Of The Use Phase [B2 B3 B4 B6] : 203 kg CO2 eq., 202.64310837690203
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-07-10
    • Return Indicator : N
    • Stocking Flag : Y
    • Device Type : Relay, Control & Measurement - measuring, monitoring device
    • Serviceability : No
    • Weee Scope : In
    • Weee Product Category : 5
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI1512006EN
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : Yes
    • Rohs Eur Status : Compliant By Exemption
    • Rohs Eur Conformity Date : 2333
    • Rohs Eur Full Compliance Status : Compliant By Exemption
    • China Rohs In Scope : Yes
    • China Rohs Label : 7
    • With Recycled Cardboard : No
    • Without Single Use Plastic : No
    • Product Contributes To Saved And Avoided Emissions : No
    • Dangerous Goods Code : LITHIUM METAL BATTERIES IN EQUIP. BUTTON CELL-BAT EXEMPT
    • Product Kit Identifier : N
    • Device Short Name : ION7413
    • Display Type : Without Display
    • Frequency Measurement Range : 42-69 Hz
    • Installation Category : III
    • Measurement Current : 50-10000 mA
    • Measurement Voltage : 57-400 V AC 42...69 Hz between phase and neutral100-690 V AC 42...69 Hz between phases
    • Memory Capacity : 64 MB
    • Mounting Mode : clip-on
    • Mounting Support : DIN rail
    • Power Consumption In W : 17 W
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Name : PowerLogic ION7400
    • Product Or Component Type : power meter
    • Range : PowerLogic
    • Returnability : No
    • Sampling Rate : 128 samples/cycle
    • Software Version : v6.3.2-2
    • Sustainable Packaging : No
    • Total Lifecycle Carbon Footprint : 237 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Pep Code : ENVPEP1406022_V2
    • Database Version : 2025-04
    • Pep Verification Date : 2025-11-28
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent external review
    • Data Source : extrapolated product
    • Functional-unit Description : The functional unit of the PowerLogic PM8000 series is a high-precision power and energy meter designed for advanced monitoring and analysis. It operates with a low power consumption of 4.7 W in active mode and supports 100% runtime, with a total energy consumption of 411.72 kWh for active components for 10 years. It features robust cybersecurity with secure protocols (HTTPS, SFTP), Syslog support, and 50 configurable user accounts. With 512 MB memory, it supports 50 data logs, waveform captures, alarms, energy trends, and custom web pages. It offers precise event timestamping to ±1 ms using PTP, NTP, IRIG-B, GPS, and network time sync. The device includes 3 digital inputs, 1 digital output, and supports up to 4 I/O modules (relays, analog/digital I/Os). It operates in harsh environments (-25 to +70°C, 5–95% humidity, up to 3000 m altitude) and mounts via DIN rail with optional remote display.
    • Functional-unit Quantity : 1
    • Functional-unit Unit : unit
    • Reference Lifetime In Y : 10
    • Energy Consumption On Product Lifetime In Kwh : 411.72
    • Energy Model - Manufacturing [A1-a3] : Electricity Mix; Low voltage; 2020; Canada, CA
    • Energy Model - Installation [A5] : No energy used
    • Energy Model - Use [B6] : Electricity Mix; Low voltage; 2020; United States, US
    • Energy Model - End Of Life [C1-c4] : Global, European and French datasets are used.
    • Recyclability Potential In % : 12
    • Height Nominal : 90.5 mm
    • Width Nominal : 90.5 mm
    • [Us] Rated Supply Voltage : 20...60 V DC +/- 10 %
    • Nbr. Of Units In Pkg. : 1
    • Package Weight(Lbs) : 854 g
    • Take-back : No
    • Warranty (In Months) : 18
    • Use Of Renewable Primary Energy Resources Used As Raw Materials (Mj) Benefits/Loads Beyond System Boundaries [D] : 2.6586
    • Customs Code : 9028300000
    • Other Technical Guide Name : PLSED310113EN
  • Environment Attributes Main
    • Ambient Air Temperature For Storage : -40-85 °C, -40-85 °C
    • Take Back : No
    • Recycled Metal Content At Cr Level : 0 %
    • China Rohs Regulation : X
    • Carbon Footprint : 237.2436355438558
    • Ambient Air Temperature For Operation : -25-70 °C-25-70 °C
    • Circularity Profile : ENVEOLI1512006EN
    • Environmental Disclosure : ENVPEP1406022_V2
    • Eu Rohs Directive : Compliant By Exemption
    • Ip Degree Of Protection : IP30 conforming to IEC 60529
    • Operating Altitude : 9842.52 ft (3000 m)
    • Packaging Made With Recycled Cardboard : No
    • Packaging Without Single Use Plastic : No
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Relative Humidity : 5-95 %
    • Pep Code : ENVPEP1406022_V2
    • Pep Verification Date : 2025-11-28
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent external review
  • General Attributes
    • Product Or Component Type : power meter
  • ETIM
    • ETIM 8 : EC002301
    • ETIM 9 : EC002301
  • Output Attributes
    • Number Of Outputs : 1 pulse
  • Input Attributes
    • Analogue Input Type : voltage (impedance 5 MOhm)current (impedance 0.3 mOhm)
    • Number Of Inputs : 3 digital 30 V AC3 digital 60 V DC
  • Specifications
    • Country of Origin : Canada
    • Depth : 90.8 mm