  • Dielectric Strength: 1500 V, 2000 V
  • Warranty Length: 18 mth
This Harmony RPM power plug-in relay has a coil control voltage of 48V DC and has 2 changeover contacts DPDT (double pole double throw) with a rating of 15A. It has large choice of number of contacts for high rated current use. It also offers LED indicator to alert on the current status of the relay. It helps to reduce the size of enclosures and increase machine reliability, you can mount nearly everywhere. This RPM product is IP40. Workability for hard-wired logic automated systems to complement the functions of industrial programmable logic controllers (PLCs). Status display with LED, clearly signal both in the day and night. 0 0 0 0 0 0 0 0 0 0 0 0
QTY
  • Product Description
  • Features
  • Specifications
This Harmony RPM power plug-in relay has a coil control voltage of 48V DC and has 2 changeover contacts DPDT (double pole double throw) with a rating of 15A. It has large choice of number of contacts for high rated current use. It also offers LED indicator to alert on the current status of the relay. It helps to reduce the size of enclosures and increase machine reliability, you can mount nearly everywhere. This RPM product is IP40. Workability for hard-wired logic automated systems to complement the functions of industrial programmable logic controllers (PLCs). Status display with LED, clearly signal both in the day and night. 0 0 0 0 0 0 0 0 0 0 0 0
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Nickel compounds, which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Complementary Attributes
    • Maximum Switching Capacity : 3750 VA, 420 W
    • Maximum Switching Voltage : 250 V IEC, 250 V IEC
    • Minimum Switching Capacity : 170 mW 10 mA, 17 V, 170 mW 10 mA, 17 V, 170 mW 10 mA, 17 V
    • Rated Operational Voltage Limits : 38.4...52.8 V DC, 38.4...52.8 V DC
    • IE Rated Operational Current : 15 A 277 V AC) UL, 15 A 277 V AC) UL, 15 A 277 V AC) UL, 15 A 277 V AC) UL, 15 A 28 V DC) UL, 15 A 28 V DC) UL, 15 A 28 V DC) UL, 15 A 28 V DC) UL, 15 A 250 V AC) NO IEC, 15 A 250 V AC) NO IEC, 15 A 250 V AC) NO IEC, 15 A 250 V AC) NO IEC, 15 A 250 V AC) NO IEC, 15 A 28 V DC) NO IEC, 15 A 28 V DC) NO IEC, 15 A 28 V DC) NO IEC, 15 A 28 V DC) NO IEC, 15 A 28 V DC) NO IEC, 7.5 A 250 V AC) NC IEC, 7.5 A 250 V AC) NC IEC, 7.5 A 250 V AC) NC IEC, 7.5 A 250 V AC) NC IEC, 7.5 A 250 V AC) NC IEC, 7.5 A 28 V DC) NC IEC, 7.5 A 28 V DC) NC IEC, 7.5 A 28 V DC) NC IEC, 7.5 A 28 V DC) NC IEC, 7.5 A 28 V DC) NC IEC
    • UC Control Circuit Voltage : 48 V DC, 48 V DC
    • UI Rated Insulation Voltage : 250 V IEC, 250 V IEC, 300 V CSA, 300 V CSA, 300 V UL, 300 V UL
    • UIMP Rated Impulse Withstand Voltage : 4 kV 1.2/50 µs, 4 kV 1.2/50 µs
  • Important Information Attributes
    • Persona Type Ids : BM9, EU, LC, OM, OM8, PB, SC, SI, VR
    • Persona Type Names : Charge Point Operator, End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, Electrician, System Integrator, IT Channel Partner
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Average Resistance : 2560 Ohm at 20 °C +/- 10 %, 2560 Ohm at 20 °C +/- 10 %, 2560 Ohm at 20 °C +/- 10 %
    • Dielectric Strength : 1500 V AC between contacts with micro disconnection, 1500 V AC between contacts with micro disconnection, 1500 V AC between contacts with micro disconnection, 1500 V AC between contacts with micro disconnection, 2000 V AC between coil and contact with reinforced, 2000 V AC between coil and contact with reinforced, 2000 V AC between coil and contact with reinforced, 2000 V AC between coil and contact with reinforced, 2000 V AC between poles with basic, 2000 V AC between poles with basic, 2000 V AC between poles with basic, 2000 V AC between poles with basic
    • Drop Out Voltage Threshold : >= 0.1 Uc DC, >= 0.1 Uc DC
    • Electrical Durability : 100000 cycles resistive, 100000 cycles resistive
    • Load Current : 15 A 250 V AC, 15 A 250 V AC, 15 A 250 V AC, 15 A 28 V DC, 15 A 28 V DC, 15 A 28 V DC
    • Operating Rate : <= 1200 cycles/hour under load, <= 1200 cycles/hour under load, <= 18000 cycles/hour no-load, <= 18000 cycles/hour no-load
    • Operating Time : 20 ms at nominal voltage, 20 ms at nominal voltage
    • Reset Time : 20 ms at nominal voltage, 20 ms at nominal voltage
    • Shock Resistance : 15 gnin operation, 15 gnin operation, 30 gnnot operating, 30 gnnot operating
    • Test Levels : level A group mounting, level A group mounting
    • Vibration Resistance : 3 gn +/- 1 mm 10-150 Hz)5 cycles in operation, 3 gn +/- 1 mm 10-150 Hz)5 cycles in operation, 3 gn +/- 1 mm 10-150 Hz)5 cycles in operation, 3 gn +/- 1 mm 10-150 Hz)5 cycles in operation, 5 gn +/- 1 mm 10-150 Hz)5 cycles not operating, 5 gn +/- 1 mm 10-150 Hz)5 cycles not operating, 5 gn +/- 1 mm 10-150 Hz)5 cycles not operating, 5 gn +/- 1 mm 10-150 Hz)5 cycles not operating
    • IE Rated Operational Current : 15 A 277 V AC) UL, 15 A 277 V AC) UL, 15 A 277 V AC) UL, 15 A 277 V AC) UL, 15 A 28 V DC) UL, 15 A 28 V DC) UL, 15 A 28 V DC) UL, 15 A 28 V DC) UL, 15 A 250 V AC) NO IEC, 15 A 250 V AC) NO IEC, 15 A 250 V AC) NO IEC, 15 A 250 V AC) NO IEC, 15 A 250 V AC) NO IEC, 15 A 28 V DC) NO IEC, 15 A 28 V DC) NO IEC, 15 A 28 V DC) NO IEC, 15 A 28 V DC) NO IEC, 15 A 28 V DC) NO IEC, 7.5 A 250 V AC) NC IEC, 7.5 A 250 V AC) NC IEC, 7.5 A 250 V AC) NC IEC, 7.5 A 250 V AC) NC IEC, 7.5 A 250 V AC) NC IEC, 7.5 A 28 V DC) NC IEC, 7.5 A 28 V DC) NC IEC, 7.5 A 28 V DC) NC IEC, 7.5 A 28 V DC) NC IEC, 7.5 A 28 V DC) NC IEC
    • ITHE Conventional Enclosed Thermal Current : 15 A -40-55 °C, 15 A -40-55 °C
    • Carbon Footprint Of The Distribution Phase A4 : 0.0051609117, 0 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 0.0053638983, 0 kg CO2 eq.
    • Carbon Footprint Of The Installation Phase A5 : 0 kg CO2 eq., 0.0001301703
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 0.4 kg CO2 eq., 0.3827508515
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 13 kg CO2 eq., 12.7864104242
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-12-02
    • Legacy WEEE Scope : Out
    • Scope Perimeter : At least in Europe
    • EOLI Availability Display : No need of specific recycling operations
    • Reach Full Compliance Status : Free of Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : NOT_CONTAINING_SVHC
    • Reach Compliance Directive : Free of Substances of Very High Concern above the threshold
    • ROHS EUR In Scope : No
    • ROHS EUR Status : Compliant
    • ROHS EUR Full Compliance Status : Pro-active compliance (Product out of EU RoHS legal scope)
    • ROHS EUR Full Compliance Status Id : PRO_ACTIVE_COMPLIANCE
    • China ROHS In Scope : Yes
    • Green Premium Status For Reporting : Green Premium product
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Return Indicator : N
    • WD Status : 1 - GSC certified
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Average Coil Consumption : 0.85 W
    • Compatibility Code : RPM
    • Package Weight Lbs : 40 g
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Or Component Type : plug-in relay
    • Protection Category : RT I
    • Range Of Product : Harmony Electromechanical Relays
    • Returnability : No
    • Series Name : RPM series
    • Shape Of Pin : flat (faston type)
    • Sustainable Packaging : Yes
    • Total Lifecycle Carbon Footprint : 13 kg CO2 eq.
    • Utilisation Coefficient : 20 %
    • Pep Code : ENVPEP2506026EN
    • Pep Verification Date : 2018-05-01
    • PCR Version : PCR-ed3-EN-2015 04 02
    • PSR Version : PSR-0005-ed2-EN-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
    • Functional Unit Description : To control a circuit by a low-power signal with complete electrical isolation between control and controlled circuits, or where several circuits must be controlled by one signal during 20 years with a 30% use rate, in compliance with French standards.
    • Functional Unit Unit : unité (unit)
    • Product Kit Identifier : N
  • Environment Attributes Main
    • EU ROHS Directive : Compliant​, Pro-active compliance (Product out of EU RoHS legal scope)
    • IP Degree Of Protection : IP40 conforming to IEC 60529, IP40 conforming to IEC 60529
    • Reach Regulation : Free of Substances of Very High Concern above the threshold, Free of Substances of Very High Concern above the threshold
    • ROHS Exemption Information : Yes
    • Take Back : No
    • Reach Free SHVC : Yes
    • Recycled Metal Content At Cr Level : 0 %
    • China ROHS Regulation : X
    • Carbon Footprint : 13.179816256
    • Ambient Air Temperature For Operation : -40-55 °C
    • Environmental Disclosure : ENVPEP2506026EN
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Free Of SVHC : Yes
    • Pep Code : ENVPEP2506026EN
    • Pep Verification Date : 2018-05-01
    • PCR Version : PCR-ed3-EN-2015 04 02
    • PSR Version : PSR-0005-ed2-EN-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Product Or Component Type : plug-in relay
    • Range Of Product : Harmony Electromechanical Relays
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Overview Attributes
    • Device Presentation : complete product