SQUARE D

plug-in relay, Harmony electromechanical relays, 15A, 2CO, lockable test button, 24V DC

plug-in relay, Harmony electromechanical relays, 15A, 2CO, lockable test button, 24V DC

SQDRPM21BD RPM21BD 3389119401814
10.55 / EA
http://schema.org/OutOfStock
  • Country of Origin: China
  • Warranty Length: 18 mth
This Harmony RPM power plug-in relay has a coil control voltage of 24V DC and has 1 changeover contact DPDT (double pole double throw) with a rating of 15A. It has large choice of number of contacts for high rated current use. It helps to reduce the size
QTY
  • Product Description
  • Features
  • Specifications
This Harmony RPM power plug-in relay has a coil control voltage of 24V DC and has 1 changeover contact DPDT (double pole double throw) with a rating of 15A. It has large choice of number of contacts for high rated current use. It helps to reduce the size
  • IE Rated Operational Current
    • 15 A 277 V AC) UL
    • 15 A 28 V DC) UL
    • 15 A 250 V AC) NO IEC
    • 15 A
  • Test Levels
    • level A group mounting
  • IP Degree Of Protection
    • IP40 conforming to IEC 60529
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Nickel compounds, which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproduc
  • Carbon Footprint Of The Installation Phase A5
    • 0.000126916
    • 0 kg CO2 eq.
  • Load Current
    • 15 A 250 V AC
    • 15 A 28 V DC
  • Carbon Footprint Of The End Of Life Phase C1 To C4
    • 0 kg CO2 eq.
    • 0.0052298009
  • Operating Time
    • 20 ms at nominal voltage
  • Maximum Switching Voltage
    • 250 V IEC
  • UC Control Circuit Voltage
    • 24 V DC
  • Carbon Footprint Of The Manufacturing Phase A1 To A3
    • 0.4 kg CO2 eq.
    • 0.3731820802
  • UI Rated Insulation Voltage
    • 250 V IEC
    • 300 V CSA
    • 300 V UL
  • Electrical Durability
    • 100000 cycles resistive
  • Reset Time
    • 20 ms at nominal voltage
  • Vibration Resistance
    • 3 gn +/- 1 mm 10-150 Hz)5 cycles in operation
    • 5 gn +/- 1 mm 10-150 Hz)5 cycles not operating
    • 5 gn +/- 1 mm 10-150 Hz
  • Market Segmentation
    • Commercial
    • Industrial
  • Rated Operational Voltage Limits
    • 19.2...26.4 V DC
  • Persona Type Names
    • Charge Point Operator
    • End User
    • Contractor
    • Original Equipment Manufacturer
    • OEM - Control Panelbuilder
    • Panel Builder
    • Electrician
    • System Integrator
    • IT Channel Partner
  • Drop Out Voltage Threshold
    • >= 0.1 Uc DC
  • Carbon Footprint Of The Use Phase B2 B3 B4 B6
    • 11 kg CO2 eq.
    • 11.4679406061
  • ITHE Conventional Enclosed Thermal Current
    • 15 A -40-55 °C
  • Persona Type Ids
    • BM9
    • EU
    • LC
    • OM
    • OM8
    • PB
    • SC
    • SI
    • VR
  • Dielectric Strength
    • 1500 V AC between contacts with micro disconnection
    • 2000 V AC between coil and contact with reinfo
  • Carbon Footprint Of The Distribution Phase A4
    • 0.0050318889
    • 0 kg CO2 eq.
  • Average Resistance
    • 640 Ohm at 20 °C +/- 10 %
  • Minimum Switching Capacity
    • 170 mW 10 mA, 17 V
  • Market Segmentation Id
    • COMMERCIAL
    • INDUSTRIAL
  • Operating Rate
    • <= 1200 cycles/hour under load
    • <= 18000 cycles/hour no-load
  • Maximum Switching Capacity
    • 3750 VA
    • 420 W
  • Shock Resistance
    • 15 gnin operation
    • 30 gnnot operating
  • UIMP Rated Impulse Withstand Voltage
    • 4 kV 1.2/50 µs
  • Important Information Attributes
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-10-15
    • Manufacturing Carbon Footprint : 0.3731820802
    • Distribution Carbon Footprint : 0.0050318889
    • Installation Carbon Footprint : 0.000126916
    • Use Carbon Footprint : 11.4679406061
    • End Of Life Carbon Footprint : 0.0052298009
    • Legacy WEEE Scope : Out
    • WEEE Product Category : 5
    • Scope Perimeter : At least in Europe
    • EOLI Availability Display : No need of specific recycling operations
    • Reach Full Compliance Status : Free of Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : NOT_CONTAINING_SVHC
    • Reach Compliance Directive : Free of Substances of Very High Concern above the threshold
    • ROHS EUR In Scope : No
    • ROHS EUR Status : Compliant
    • ROHS EUR Conformity Date : 1930
    • ROHS EUR Full Compliance Status : Pro-active compliance (Product out of EU RoHS legal scope)
    • ROHS EUR Full Compliance Status Id : PRO_ACTIVE_COMPLIANCE
    • China ROHS In Scope : Yes
    • China ROHS Label : 1
    • Green Premium Status For Reporting : Green Premium product
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Return Indicator : Y
    • WD Status : 1 - GSC certified
    • Tier Id : 1
    • Tier : 1
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Average Coil Consumption : 0.85 W
    • Compatibility Code : RPM
    • Package Weight Lbs : 39 g
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Or Component Type : plug-in relay
    • Protection Category : RT I
    • Range Of Product : Harmony Electromechanical Relays
    • Returnability : Yes
    • Series Name : RPM series
    • Shape Of Pin : flat (faston type)
    • Sustainable Packaging : Yes
    • Total Lifecycle Carbon Footprint : 12 kg CO2 eq.
    • Utilisation Coefficient : 20 %
    • Carbon Footprint Kg Co2 Eq Total Life Cycle : 11.8515112921
    • Pep Code : ENVPEP2506026EN
    • Pep Verification Date : 2018-05-01
    • PCR Version : PCR-ed3-EN-2015 04 02
    • PSR Version : PSR-0005-ed2-EN-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
    • Product Weight In G : 39
    • Functional Unit Description : To control a circuit by a low-power signal with complete electrical isolation between control and controlled circuits, or where several circuits must be controlled by one signal during 20 years with a 30% use rate, in compliance with French standards.
    • Functional Unit Quantity : 1
    • Functional Unit Unit : unité (unit)
    • Reference Lifetime In Y : 20
    • Energy Consumption On Product Lifetime In Kwh : 23.40672
    • Energy Model Manufacturing A1 A3 : Energy model used: China
    • Energy Model Installation A5 : Electricity mix; AC; < 1kV; EU-27
    • Energy Model Use B6 : Electricity mix; AC; < 1kV; EU-27
    • Energy Model End Of Life C1 C4 : Electricity mix; AC; < 1kV; EU-27
    • Components For Re Use Kg Total Life Cycle : 0
    • Components For Re Use Kg Manufacturing A1 A3 : 0
    • Components For Re Use Kg Distribution A4 : 0
    • Components For Re Use Kg Installation A5 : 0
    • Components For Re Use Kg Operational Energy Use B6 : 0
    • Components For Re Use Kg End Of Life C1 C4 : 0
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Total Life Cycle : 0.0032159169
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Manufacturing A1 A3 : 0.0032149201
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Distribution A4 : 0.0000000002
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Installation A5 : 0
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Operational Energy Use B6 : 0.0000009965
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb End Of Life C1 C4 : 0.0000000001
    • Depletion Of Abiotic Resources Fossil Fuels Mj Total Life Cycle : 135.293569642
    • Depletion Of Abiotic Resources Fossil Fuels Mj Manufacturing A1 A3 : 5.0006746136
    • Depletion Of Abiotic Resources Fossil Fuels Mj Distribution A4 : 0.0706945245
    • Depletion Of Abiotic Resources Fossil Fuels Mj Installation A5 : 0.0016517527
    • Depletion Of Abiotic Resources Fossil Fuels Mj Operational Energy Use B6 : 130.1709333333
    • Depletion Of Abiotic Resources Fossil Fuels Mj End Of Life C1 C4 : 0.0496154179
    • Exported Energy Mj By Energy Vector Total Life Cycle : 0.0000074133
    • Exported Energy Mj By Energy Vector Manufacturing A1 A3 : 0.0000006969
    • Exported Energy Mj By Energy Vector Distribution A4 : 0
    • Exported Energy Mj By Energy Vector Installation A5 : 0.0000067164
    • Exported Energy Mj By Energy Vector Operational Energy Use B6 : 0
    • Exported Energy Mj By Energy Vector End Of Life C1 C4 : 0
    • Hazardous Waste Disposed Of Kg Total Life Cycle : 8.5432339114
    • Hazardous Waste Disposed Of Kg Manufacturing A1 A3 : 8.4809929264
    • Hazardous Waste Disposed Of Kg Distribution A4 : 0
    • Hazardous Waste Disposed Of Kg Installation A5 : 0.0000000062
    • Hazardous Waste Disposed Of Kg Operational Energy Use B6 : 0.0059786
    • Hazardous Waste Disposed Of Kg End Of Life C1 C4 : 0.0562623788
    • Materials For Energy Recovery Kg Total Life Cycle : 0.000574476
    • Materials For Energy Recovery Kg Manufacturing A1 A3 : 0
    • Materials For Energy Recovery Kg Distribution A4 : 0
    • Materials For Energy Recovery Kg Installation A5 : 0
    • Materials For Energy Recovery Kg Operational Energy Use B6 : 0
    • Materials For Energy Recovery Kg End Of Life C1 C4 : 0.000574476
    • Materials For Recycling Kg Total Life Cycle : 0.0241194105
    • Materials For Recycling Kg Manufacturing A1 A3 : 0.0038091669
    • Materials For Recycling Kg Distribution A4 : 0
    • Materials For Recycling Kg Installation A5 : 0.0023331543
    • Materials For Recycling Kg Operational Energy Use B6 : 0
    • Materials For Recycling Kg End Of Life C1 C4 : 0.0179770893
    • Net Use Of Fresh Water M3 Total Life Cycle : 41.5869967415
    • Net Use Of Fresh Water M3 Manufacturing A1 A3 : 0.0050035355
    • Net Use Of Fresh Water M3 Distribution A4 : 0.0000004503
    • Net Use Of Fresh Water M3 Installation A5 : 0.0000000139
    • Net Use Of Fresh Water M3 Operational Energy Use B6 : 41.5819878788
    • Net Use Of Fresh Water M3 End Of Life C1 C4 : 0.000004863
    • Non Hazardous Waste Disposed Of Kg Total Life Cycle : 42.9383133474
    • Non Hazardous Waste Disposed Of Kg Manufacturing A1 A3 : 0.1798781766
    • Non Hazardous Waste Disposed Of Kg Distribution A4 : 0.0001787798
    • Non Hazardous Waste Disposed Of Kg Installation A5 : 0.0000172266
    • Non Hazardous Waste Disposed Of Kg Operational Energy Use B6 : 42.7580727273
    • Non Hazardous Waste Disposed Of Kg End Of Life C1 C4 : 0.0001664371
    • Ozone Depletion Kg Equivalent Cfc 11 Total Life Cycle : 0.0000008078
    • Ozone Depletion Kg Equivalent Cfc 11 Manufacturing A1 A3 : 0.0000000604
    • Ozone Depletion Kg Equivalent Cfc 11 Distribution A4 : 0
    • Ozone Depletion Kg Equivalent Cfc 11 Installation A5 : 0
    • Ozone Depletion Kg Equivalent Cfc 11 Operational Energy Use B6 : 0.0000007471
    • Ozone Depletion Kg Equivalent Cfc 11 End Of Life C1 C4 : 0.0000000003
    • Radioactive Waste Disposed Of Kg Total Life Cycle : 0.0286673232
    • Radioactive Waste Disposed Of Kg Manufacturing A1 A3 : 0.0001109411
    • Radioactive Waste Disposed Of Kg Distribution A4 : 0.0000001273
    • Radioactive Waste Disposed Of Kg Installation A5 : 0.0000000034
    • Radioactive Waste Disposed Of Kg Operational Energy Use B6 : 0.0285559879
    • Radioactive Waste Disposed Of Kg End Of Life C1 C4 : 0.0000002635
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 204.5228597507
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 4.4796358397
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0.0710521352
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0.001654869
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 : 199.9162060606
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 0.0543108462
    • Total Use Of Primary Energy During The Life Cycle Mj Total Life Cycle : 234.2426613169
    • Total Use Of Primary Energy During The Life Cycle Mj Manufacturing A1 A3 : 5.0724521876
    • Total Use Of Primary Energy During The Life Cycle Mj Distribution A4 : 0.0711492009
    • Total Use Of Primary Energy During The Life Cycle Mj Installation A5 : 0.0016574745
    • Total Use Of Primary Energy During The Life Cycle Mj Operational Energy Use B6 : 229.043030303
    • Total Use Of Primary Energy During The Life Cycle Mj End Of Life C1 C4 : 0.0543721509
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 29.7177740332
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 0.5928163479
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0.0000948179
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0.0000025742
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 : 29.1248
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 0.0000602932
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 0.3215635316
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 0.3215635316
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 0
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 204.2012655668
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 4.1580416558
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0.0710521352
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0.001654869
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 : 199.9162060606
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 0.0543108462
    • Use Of Non Renewable Secondary Fuels Mj Total Life Cycle : 0
    • Use Of Non Renewable Secondary Fuels Mj Manufacturing A1 A3 : 0
    • Use Of Non Renewable Secondary Fuels Mj Distribution A4 : 0
    • Use Of Non Renewable Secondary Fuels Mj Installation A5 : 0
    • Use Of Non Renewable Secondary Fuels Mj Operational Energy Use B6 : 0
    • Use Of Non Renewable Secondary Fuels Mj End Of Life C1 C4 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 0.0463335735
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 0.0463335735
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 0
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 29.6714379053
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 0.5464802201
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0.0000948179
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0.0000025742
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 : 29.1248
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 0.0000602932
    • Use Of Renewable Secondary Fuels Mj Total Life Cycle : 0
    • Use Of Renewable Secondary Fuels Mj Manufacturing A1 A3 : 0
    • Use Of Renewable Secondary Fuels Mj Distribution A4 : 0
    • Use Of Renewable Secondary Fuels Mj Installation A5 : 0
    • Use Of Renewable Secondary Fuels Mj Operational Energy Use B6 : 0
    • Use Of Renewable Secondary Fuels Mj End Of Life C1 C4 : 0
    • Use Of Secondary Materials Kg Total Life Cycle : 0.0018418994
    • Use Of Secondary Materials Kg Manufacturing A1 A3 : 0.0018418994
    • Use Of Secondary Materials Kg Distribution A4 : 0
    • Use Of Secondary Materials Kg Installation A5 : 0
    • Use Of Secondary Materials Kg Operational Energy Use B6 : 0
    • Use Of Secondary Materials Kg End Of Life C1 C4 : 0
    • Air Pollution M3 Total Life Cycle : 620.0601128687
    • Air Pollution M3 Manufacturing A1 A3 : 125.8585276395
    • Air Pollution M3 Distribution A4 : 0.2140504323
    • Air Pollution M3 Installation A5 : 0.0050615195
    • Air Pollution M3 Operational Energy Use B6 : 493.5912727273
    • Air Pollution M3 End Of Life C1 C4 : 0.3912005502
    • Water Pollution M3 Total Life Cycle : 534.4153040564
    • Water Pollution M3 Manufacturing A1 A3 : 59.9048991354
    • Water Pollution M3 Distribution A4 : 0.8274600472
    • Water Pollution M3 Installation A5 : 0.0192471182
    • Water Pollution M3 Operational Energy Use B6 : 473.2071515152
    • Water Pollution M3 End Of Life C1 C4 : 0.4565462405
    • Acidification Of Soil And Water Kg Equivalent So2 Total Life Cycle : 0.0513342034
    • Photochemical Ozone Formation Kg Equivalent C2h4 Total Life Cycle : 0.0028179698
    • Water Eutrophication Kg Equivalent P04 3 Total Life Cycle : 0.0032340172
    • Acidification Of Soil And Water Kg Equivalent So2 Manufacturing A1 A3 : 0.0034626932
    • Acidification Of Soil And Water Kg Equivalent So2 Distribution A4 : 0.000022975
    • Acidification Of Soil And Water Kg Equivalent So2 Installation A5 : 0.0000005288
    • Acidification Of Soil And Water Kg Equivalent So2 Operational Energy Use B6 : 0.047836897
    • Acidification Of Soil And Water Kg Equivalent So2 End Of Life C1 C4 : 0.0000111094
    • Global Warming Kg Equivalent Co2 Total Life Cycle : 11.8515112921
    • Global Warming Kg Equivalent Co2 Manufacturing A1 A3 : 0.3731820802
    • Global Warming Kg Equivalent Co2 Distribution A4 : 0.0050318889
    • Global Warming Kg Equivalent Co2 Installation A5 : 0.000126916
    • Global Warming Kg Equivalent Co2 Operational Energy Use B6 : 11.4679406061
    • Global Warming Kg Equivalent Co2 End Of Life C1 C4 : 0.0052298009
    • Photochemical Ozone Formation Kg Equivalent C2h4 Manufacturing A1 A3 : 0.0001866472
    • Photochemical Ozone Formation Kg Equivalent C2h4 Distribution A4 : 0.0000016395
    • Photochemical Ozone Formation Kg Equivalent C2h4 Installation A5 : 0.0000000395
    • Photochemical Ozone Formation Kg Equivalent C2h4 Operational Energy Use B6 : 0.0026284788
    • Photochemical Ozone Formation Kg Equivalent C2h4 End Of Life C1 C4 : 0.0000011648
    • Water Eutrophication Kg Equivalent P04 3 Manufacturing A1 A3 : 0.0003374414
    • Water Eutrophication Kg Equivalent P04 3 Distribution A4 : 0.0000052916
    • Water Eutrophication Kg Equivalent P04 3 Installation A5 : 0.0000001285
    • Water Eutrophication Kg Equivalent P04 3 Operational Energy Use B6 : 0.0028881891
    • Water Eutrophication Kg Equivalent P04 3 End Of Life C1 C4 : 0.0000029665
    • Warranty In Months : 18
  • General Attributes
    • Product Or Component Type : plug-in relay
    • Range Of Product : Harmony Electromechanical Relays
  • Environment Attributes
    • ROHS Exemption Information : Yes
    • China ROHS url : https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=exportPdfRoHSChina&pid=648636&lang=en-us
    • Take Back : No
    • Reach Free SHVC : Yes
    • Recycled Metal Content At Cr Level : 0 %
    • China ROHS Regulation : X
    • Carbon Footprint : 11.8515112921
    • Ambient Air Temperature For Operation : -40-55 °C
    • Environmental Disclosure : ENVPEP2506026EN
    • EU ROHS Directive : Pro-active compliance (Product out of EU RoHS legal scope)
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Free Of SVHC : Yes
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP2506026EN
    • Pep Verification Date : 2018-05-01
    • PCR Version : PCR-ed3-EN-2015 04 02
    • PSR Version : PSR-0005-ed2-EN-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Specifications
    • Country of Origin : China
  • Overview Attributes
    • Device Presentation : complete product