plug-in relay, Harmony electromechanical relays, 15A, 1CO, lockable test button, 24V AC

PLUG-IN RELAY 250V 15A RPM +OP

SQDRPM11B7 RPM11B7 3389119401647
7.91 / EA
http://schema.org/OutOfStock
  • Country of Origin: China
  • Warranty Length: 18 mth
This Harmony RPM power plug-in relay has a coil control voltage of 24V AC and has 1 changeover contact SPDT (single pole double throw) with a rating of 15A. It has large choice of number of contacts for high rated current use. It helps to reduce the size
QTY
  • Product Description
  • Features
  • Specifications
This Harmony RPM power plug-in relay has a coil control voltage of 24V AC and has 1 changeover contact SPDT (single pole double throw) with a rating of 15A. It has large choice of number of contacts for high rated current use. It helps to reduce the size
  • IE Rated Operational Current
    • 15 A 277 V AC) UL
    • 15 A 28 V DC) UL
    • 15 A 250 V AC) NO IEC
    • 15 A
  • Test Levels
    • level A group mounting
  • IP Degree Of Protection
    • IP40 conforming to IEC 60529
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Nickel compounds, which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproduc
  • Carbon Footprint Of The Installation Phase A5
    • 0 kg CO2 eq.
    • 0.0000781022
  • Load Current
    • 15 A 250 V AC
    • 15 A 28 V DC
  • Carbon Footprint Of The End Of Life Phase C1 To C4
    • 0.003218339
    • 0 kg CO2 eq.
  • Operating Time
    • 20 ms at nominal voltage
  • Maximum Switching Voltage
    • 250 V IEC
  • UC Control Circuit Voltage
    • 24 V AC 50/60 Hz
  • Carbon Footprint Of The Manufacturing Phase A1 To A3
    • 0.2 kg CO2 eq.
    • 0.2296505109
  • UI Rated Insulation Voltage
    • 250 V IEC
    • 300 V CSA
    • 300 V UL
  • Electrical Durability
    • 100000 cycles resistive
  • Reset Time
    • 20 ms at nominal voltage
  • Vibration Resistance
    • 3 gn +/- 1 mm 10-150 Hz)5 cycles in operation
    • 5 gn +/- 1 mm 10-150 Hz)5 cycles not operating
    • 5 gn +/- 1 mm 10-150 Hz
  • Market Segmentation
    • Commercial
    • Industrial
  • Rated Operational Voltage Limits
    • 19.2...26.4 V AC
  • Persona Type Names
    • Charge Point Operator
    • End User
    • Contractor
    • Original Equipment Manufacturer
    • OEM - Control Panelbuilder
    • Panel Builder
    • Electrician
    • System Integrator
    • IT Channel Partner
  • Drop Out Voltage Threshold
    • >= 0.15 Uc AC
  • Carbon Footprint Of The Use Phase B2 B3 B4 B6
    • 16 kg CO2 eq.
    • 15.8199210606
  • ITHE Conventional Enclosed Thermal Current
    • 15 A -40-55 °C
  • Persona Type Ids
    • BM9
    • EU
    • LC
    • OM
    • OM8
    • PB
    • SC
    • SI
    • VR
  • Dielectric Strength
    • 1500 V AC between contacts with micro disconnection
    • 2000 V AC between coil and contact with reinfo
  • Average Coil Consumption In VA
    • 1.6 60 Hz
  • Carbon Footprint Of The Distribution Phase A4
    • 0.003096547
    • 0 kg CO2 eq.
  • Average Resistance
    • 177 Ohm at 20 °C +/- 15 %
  • Minimum Switching Capacity
    • 170 mW 10 mA, 17 V
  • Market Segmentation Id
    • COMMERCIAL
    • INDUSTRIAL
  • Operating Rate
    • <= 1200 cycles/hour under load
    • <= 18000 cycles/hour no-load
  • Maximum Switching Capacity
    • 3750 VA
    • 420 W
  • Shock Resistance
    • 15 gnin operation
    • 30 gnnot operating
  • UIMP Rated Impulse Withstand Voltage
    • 4 kV 1.2/50 µs
  • Assets
    • CAD : https://download.schneider-electric.com/files?p_Doc_Ref=MCADID0001789_3D-CAD
  • Important Information Attributes
    • Local Data Status : Publishable
    • Local Publishable Date : 2024-07-03
    • HTML Description : Power Plug-in Relay - Zelio RPM - 1 C/O - 24 V AC - 15 A
    • Manufacturer : Schneider Electric
    • Manufacturing Carbon Footprint : 0.2296505109
    • Distribution Carbon Footprint : 0.003096547
    • Installation Carbon Footprint : 0.0000781022
    • Use Carbon Footprint : 15.8199210606
    • End Of Life Carbon Footprint : 0.003218339
    • Legacy WEEE Scope : Out
    • WEEE Product Category : 5
    • Scope Perimeter : At least in Europe
    • EOLI Availability Display : No need of specific recycling operations
    • Reach Full Compliance Status : Free of Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : NOT_CONTAINING_SVHC
    • Reach Compliance Directive : Free of Substances of Very High Concern above the threshold
    • ROHS EUR In Scope : No
    • ROHS EUR Status : Compliant
    • ROHS EUR Conformity Date : 1930
    • ROHS EUR Full Compliance Status : Pro-active compliance (Product out of EU RoHS legal scope)
    • ROHS EUR Full Compliance Status Id : PRO_ACTIVE_COMPLIANCE
    • China ROHS In Scope : Yes
    • China ROHS Label : 1
    • Green Premium Status For Reporting : Green Premium product
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Return Indicator : Y
    • WD Status : 1 - GSC certified
    • Tier Id : 1
    • Tier : 1
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Compatibility Code : RPM
    • Package Weight Lbs : 24.000 g
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Or Component Type : plug-in relay
    • Protection Category : RT I
    • Range Of Product : Harmony Electromechanical Relays
    • Returnability : Yes
    • Series Name : RPM series
    • Shape Of Pin : flat (faston type)
    • Sustainable Packaging : Yes
    • Total Lifecycle Carbon Footprint : 16 kg CO2 eq.
    • Utilisation Coefficient : 20 %
    • Carbon Footprint Kg Co2 Eq Total Life Cycle : 16.0559645597
    • Relationship Type : Compatible relationship
    • Accessories : RPZF1
    • Pep Code : ENVPEP2506026EN
    • Pep Verification Date : 2018-05-01
    • PCR Version : PCR-ed3-EN-2015 04 02
    • PSR Version : PSR-0005-ed2-EN-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
    • Product Weight In G : 24
    • Functional Unit Description : To control a circuit by a low-power signal with complete electrical isolation between control and controlled circuits, or where several circuits must be controlled by one signal during 20 years with a 30% use rate, in compliance with French standards.
    • Functional Unit Quantity : 1
    • Functional Unit Unit : unité (unit)
    • Reference Lifetime In Y : 20
    • Energy Consumption On Product Lifetime In Kwh : 32.28936
    • Energy Model Manufacturing A1 A3 : Energy model used: China
    • Energy Model Installation A5 : Electricity mix; AC; < 1kV; EU-27
    • Energy Model Use B6 : Electricity mix; AC; < 1kV; EU-27
    • Energy Model End Of Life C1 C4 : Electricity mix; AC; < 1kV; EU-27
    • Components For Re Use Kg Total Life Cycle : 0
    • Components For Re Use Kg Manufacturing A1 A3 : 0
    • Components For Re Use Kg Distribution A4 : 0
    • Components For Re Use Kg Installation A5 : 0
    • Components For Re Use Kg Operational Energy Use B6 : 0
    • Components For Re Use Kg End Of Life C1 C4 : 0
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Total Life Cycle : 0.0019797872
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Manufacturing A1 A3 : 0.0019784124
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Distribution A4 : 0.0000000001
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Installation A5 : 0
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Operational Energy Use B6 : 0.0000013746
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb End Of Life C1 C4 : 0.0000000001
    • Depletion Of Abiotic Resources Fossil Fuels Mj Total Life Cycle : 182.7220249079
    • Depletion Of Abiotic Resources Fossil Fuels Mj Manufacturing A1 A3 : 3.0773382237
    • Depletion Of Abiotic Resources Fossil Fuels Mj Distribution A4 : 0.0435043228
    • Depletion Of Abiotic Resources Fossil Fuels Mj Installation A5 : 0.0010164632
    • Depletion Of Abiotic Resources Fossil Fuels Mj Operational Energy Use B6 : 179.5696333333
    • Depletion Of Abiotic Resources Fossil Fuels Mj End Of Life C1 C4 : 0.0305325648
    • Exported Energy Mj By Energy Vector Total Life Cycle : 0.000004562
    • Exported Energy Mj By Energy Vector Manufacturing A1 A3 : 0.0000004288
    • Exported Energy Mj By Energy Vector Distribution A4 : 0
    • Exported Energy Mj By Energy Vector Installation A5 : 0.0000041332
    • Exported Energy Mj By Energy Vector Operational Energy Use B6 : 0
    • Exported Energy Mj By Energy Vector End Of Life C1 C4 : 0
    • Hazardous Waste Disposed Of Kg Total Life Cycle : 5.2619430013
    • Hazardous Waste Disposed Of Kg Manufacturing A1 A3 : 5.2190725701
    • Hazardous Waste Disposed Of Kg Distribution A4 : 0
    • Hazardous Waste Disposed Of Kg Installation A5 : 0.0000000038
    • Hazardous Waste Disposed Of Kg Operational Energy Use B6 : 0.008247425
    • Hazardous Waste Disposed Of Kg End Of Life C1 C4 : 0.0346230024
    • Materials For Energy Recovery Kg Total Life Cycle : 0.0003535237
    • Materials For Energy Recovery Kg Manufacturing A1 A3 : 0
    • Materials For Energy Recovery Kg Distribution A4 : 0
    • Materials For Energy Recovery Kg Installation A5 : 0
    • Materials For Energy Recovery Kg Operational Energy Use B6 : 0
    • Materials For Energy Recovery Kg End Of Life C1 C4 : 0.0003535237
    • Materials For Recycling Kg Total Life Cycle : 0.0148427142
    • Materials For Recycling Kg Manufacturing A1 A3 : 0.0023441027
    • Materials For Recycling Kg Distribution A4 : 0
    • Materials For Recycling Kg Installation A5 : 0.0014357873
    • Materials For Recycling Kg Operational Energy Use B6 : 0
    • Materials For Recycling Kg End Of Life C1 C4 : 0.0110628242
    • Net Use Of Fresh Water M3 Total Life Cycle : 57.3650611649
    • Net Use Of Fresh Water M3 Manufacturing A1 A3 : 0.0030790988
    • Net Use Of Fresh Water M3 Distribution A4 : 0.0000002771
    • Net Use Of Fresh Water M3 Installation A5 : 0.0000000085
    • Net Use Of Fresh Water M3 Operational Energy Use B6 : 57.3619787879
    • Net Use Of Fresh Water M3 End Of Life C1 C4 : 0.0000029926
    • Non Hazardous Waste Disposed Of Kg Total Life Cycle : 59.0952945774
    • Non Hazardous Waste Disposed Of Kg Manufacturing A1 A3 : 0.1106942625
    • Non Hazardous Waste Disposed Of Kg Distribution A4 : 0.0001100183
    • Non Hazardous Waste Disposed Of Kg Installation A5 : 0.000010601
    • Non Hazardous Waste Disposed Of Kg Operational Energy Use B6 : 58.9843772727
    • Non Hazardous Waste Disposed Of Kg End Of Life C1 C4 : 0.0001024228
    • Ozone Depletion Kg Equivalent Cfc 11 Total Life Cycle : 0.0000010679
    • Ozone Depletion Kg Equivalent Cfc 11 Manufacturing A1 A3 : 0.0000000372
    • Ozone Depletion Kg Equivalent Cfc 11 Distribution A4 : 0
    • Ozone Depletion Kg Equivalent Cfc 11 Installation A5 : 0
    • Ozone Depletion Kg Equivalent Cfc 11 Operational Energy Use B6 : 0.0000010306
    • Ozone Depletion Kg Equivalent Cfc 11 End Of Life C1 C4 : 0.0000000002
    • Radioactive Waste Disposed Of Kg Total Life Cycle : 0.0394612428
    • Radioactive Waste Disposed Of Kg Manufacturing A1 A3 : 0.0000682714
    • Radioactive Waste Disposed Of Kg Distribution A4 : 0.0000000784
    • Radioactive Waste Disposed Of Kg Installation A5 : 0.0000000021
    • Radioactive Waste Disposed Of Kg Operational Energy Use B6 : 0.0393927288
    • Radioactive Waste Disposed Of Kg End Of Life C1 C4 : 0.0000001622
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 278.6174744153
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 2.7566989783
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0.0437243909
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0.0010183809
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 : 275.7826106061
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 0.0334220592
    • Total Use Of Primary Energy During The Life Cycle Mj Total Life Cycle : 319.1625759619
    • Total Use Of Primary Energy During The Life Cycle Mj Manufacturing A1 A3 : 3.1215090385
    • Total Use Of Primary Energy During The Life Cycle Mj Distribution A4 : 0.0437841237
    • Total Use Of Primary Energy During The Life Cycle Mj Installation A5 : 0.0010199843
    • Total Use Of Primary Energy During The Life Cycle Mj Operational Energy Use B6 : 315.9628030303
    • Total Use Of Primary Energy During The Life Cycle Mj End Of Life C1 C4 : 0.0334597852
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 40.5423070973
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 0.3648100603
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0.0000583495
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0.0000015841
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 : 40.1774
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 0.0000371035
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 0.1978852502
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 0.1978852502
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 0
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 278.4195703022
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 2.5587948651
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0.0437243909
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0.0010183809
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 : 275.7826106061
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 0.0334220592
    • Use Of Non Renewable Secondary Fuels Mj Total Life Cycle : 0
    • Use Of Non Renewable Secondary Fuels Mj Manufacturing A1 A3 : 0
    • Use Of Non Renewable Secondary Fuels Mj Distribution A4 : 0
    • Use Of Non Renewable Secondary Fuels Mj Installation A5 : 0
    • Use Of Non Renewable Secondary Fuels Mj Operational Energy Use B6 : 0
    • Use Of Non Renewable Secondary Fuels Mj End Of Life C1 C4 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 0.0285129683
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 0.0285129683
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 0
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 40.5137925571
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 0.33629552
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0.0000583495
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0.0000015841
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 : 40.1774
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 0.0000371035
    • Use Of Renewable Secondary Fuels Mj Total Life Cycle : 0
    • Use Of Renewable Secondary Fuels Mj Manufacturing A1 A3 : 0
    • Use Of Renewable Secondary Fuels Mj Distribution A4 : 0
    • Use Of Renewable Secondary Fuels Mj Installation A5 : 0
    • Use Of Renewable Secondary Fuels Mj Operational Energy Use B6 : 0
    • Use Of Renewable Secondary Fuels Mj End Of Life C1 C4 : 0
    • Use Of Secondary Materials Kg Total Life Cycle : 0.0011334766
    • Use Of Secondary Materials Kg Manufacturing A1 A3 : 0.0011334766
    • Use Of Secondary Materials Kg Distribution A4 : 0
    • Use Of Secondary Materials Kg Installation A5 : 0
    • Use Of Secondary Materials Kg Operational Energy Use B6 : 0
    • Use Of Secondary Materials Kg End Of Life C1 C4 : 0
    • Air Pollution M3 Total Life Cycle : 758.7317058213
    • Air Pollution M3 Manufacturing A1 A3 : 77.4514016243
    • Air Pollution M3 Distribution A4 : 0.1317233429
    • Air Pollution M3 Installation A5 : 0.0031147812
    • Air Pollution M3 Operational Energy Use B6 : 680.9047272727
    • Air Pollution M3 End Of Life C1 C4 : 0.2407388001
    • Water Pollution M3 Total Life Cycle : 690.4515705615
    • Water Pollution M3 Manufacturing A1 A3 : 36.8645533141
    • Water Pollution M3 Distribution A4 : 0.5092061829
    • Water Pollution M3 Installation A5 : 0.0118443804
    • Water Pollution M3 Operational Energy Use B6 : 652.7850151515
    • Water Pollution M3 End Of Life C1 C4 : 0.2809515326
    • Acidification Of Soil And Water Kg Equivalent So2 Total Life Cycle : 0.0681427583
    • Photochemical Ozone Formation Kg Equivalent C2h4 Total Life Cycle : 0.0037425727
    • Water Eutrophication Kg Equivalent P04 3 Total Life Cycle : 0.0041970482
    • Acidification Of Soil And Water Kg Equivalent So2 Manufacturing A1 A3 : 0.0021308881
    • Acidification Of Soil And Water Kg Equivalent So2 Distribution A4 : 0.0000141384
    • Acidification Of Soil And Water Kg Equivalent So2 Installation A5 : 0.0000003254
    • Acidification Of Soil And Water Kg Equivalent So2 Operational Energy Use B6 : 0.0659905697
    • Acidification Of Soil And Water Kg Equivalent So2 End Of Life C1 C4 : 0.0000068366
    • Global Warming Kg Equivalent Co2 Total Life Cycle : 16.0559645597
    • Global Warming Kg Equivalent Co2 Manufacturing A1 A3 : 0.2296505109
    • Global Warming Kg Equivalent Co2 Distribution A4 : 0.003096547
    • Global Warming Kg Equivalent Co2 Installation A5 : 0.0000781022
    • Global Warming Kg Equivalent Co2 Operational Energy Use B6 : 15.8199210606
    • Global Warming Kg Equivalent Co2 End Of Life C1 C4 : 0.003218339
    • Photochemical Ozone Formation Kg Equivalent C2h4 Manufacturing A1 A3 : 0.0001148598
    • Photochemical Ozone Formation Kg Equivalent C2h4 Distribution A4 : 0.0000010089
    • Photochemical Ozone Formation Kg Equivalent C2h4 Installation A5 : 0.0000000243
    • Photochemical Ozone Formation Kg Equivalent C2h4 Operational Energy Use B6 : 0.0036259629
    • Photochemical Ozone Formation Kg Equivalent C2h4 End Of Life C1 C4 : 0.0000007168
    • Water Eutrophication Kg Equivalent P04 3 Manufacturing A1 A3 : 0.0002076563
    • Water Eutrophication Kg Equivalent P04 3 Distribution A4 : 0.0000032564
    • Water Eutrophication Kg Equivalent P04 3 Installation A5 : 0.0000000791
    • Water Eutrophication Kg Equivalent P04 3 Operational Energy Use B6 : 0.0039842309
    • Water Eutrophication Kg Equivalent P04 3 End Of Life C1 C4 : 0.0000018255
  • General Attributes
    • Product Or Component Type : plug-in relay
    • Range Of Product : Harmony Electromechanical Relays
  • Environment Attributes
    • ROHS Exemption Information : Yes
    • China ROHS url : https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=exportPdfRoHSChina&pid=648586&lang=en-us
    • Take Back : No
    • Reach Free SHVC : Yes
    • China ROHS Regulation : X
    • Carbon Footprint : 16.0559645597
    • Ambient Air Temperature For Operation : -40-55 °C
    • Environmental Disclosure : ENVPEP2506026EN
    • EU ROHS Directive : Pro-active compliance (Product out of EU RoHS legal scope)
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Free Of SVHC : Yes
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP2506026EN
    • Pep Verification Date : 2018-05-01
    • PCR Version : PCR-ed3-EN-2015 04 02
    • PSR Version : PSR-0005-ed2-EN-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Specifications
    • Country of Origin : China
  • Overview Attributes
    • Device Presentation : complete product