SQUARE D

Power module, TeSys island, 15A at AC-1, 9A at AC-3, 4kW, 5hp

POWER INTERFACE MODULE, TESYS

SQDTPRPM009 TPRPM009 SQDTPRPM009
266.78 / EA
http://schema.org/OutOfStock
  • Depth: 115 mm
TeSys island power module, 3 poles, 9A/690V. Connected to a TPRBC bus coupler it protects and monitors loads up to 9A and motors up to 4kW@400V / 5hp@480V. External power switching devices could be controlled if associated to a digital IO module TPRDG4X2. It provides motor protection functions including thermal overload (setting 0.18-9A, tripping class 5-30), phase loss, phase unbalance and reversal, long start (stall), locked rotor (jam), rapid cycle lockout, ground current detection. Monitoring of the load includes max/average voltages and currents, number of faults, active and reactive power/energy when associated to a TPRVM001 voltage module. Mounting on DIN rail together with the other modules of the TeSys island configuration. Multi standards certified (IEC, UL, CSA, CCC, EAC).
QTY
  • Product Description
  • Specifications
TeSys island power module, 3 poles, 9A/690V. Connected to a TPRBC bus coupler it protects and monitors loads up to 9A and motors up to 4kW@400V / 5hp@480V. External power switching devices could be controlled if associated to a digital IO module TPRDG4X2. It provides motor protection functions including thermal overload (setting 0.18-9A, tripping class 5-30), phase loss, phase unbalance and reversal, long start (stall), locked rotor (jam), rapid cycle lockout, ground current detection. Monitoring of the load includes max/average voltages and currents, number of faults, active and reactive power/energy when associated to a TPRVM001 voltage module. Mounting on DIN rail together with the other modules of the TeSys island configuration. Multi standards certified (IEC, UL, CSA, CCC, EAC).
  • Assets
    • Cad : https://download.schneider-electric.com/files?p_Doc_Ref=MCADPD0005279_3D-CAD&p_File_name=MCADPD0005279_3D-simplified.stp, https://download.schneider-electric.com/files?p_Doc_Ref=MCADPD0005279_3D-CAD&p_File_name=MCADPD0005279_2D-back.dwg, https://download.schneider-electric.com/files?p_Doc_Ref=MCADPD0005279_3D-CAD&p_File_name=MCADPD0005279_2D-back.dxf, https://download.schneider-electric.com/files?p_Doc_Ref=MCADPD0005279_3D-CAD&p_File_name=MCADPD0005279_2D-bottom.dwg, https://download.schneider-electric.com/files?p_Doc_Ref=MCADPD0005279_3D-CAD&p_File_name=MCADPD0005279_2D-bottom.dxf, https://download.schneider-electric.com/files?p_Doc_Ref=MCADPD0005279_3D-CAD&p_File_name=MCADPD0005279_2D-front.dwg, https://download.schneider-electric.com/files?p_Doc_Ref=MCADPD0005279_3D-CAD&p_File_name=MCADPD0005279_2D-front.dxf, https://download.schneider-electric.com/files?p_Doc_Ref=MCADPD0005279_3D-CAD&p_File_name=MCADPD0005279_2D-isometric.dwg, https://download.schneider-electric.com/files?p_Doc_Ref=MCADPD0005279_3D-CAD&p_File_name=MCADPD0005279_2D-isometric.dxf, https://download.schneider-electric.com/files?p_Doc_Ref=MCADPD0005279_3D-CAD&p_File_name=MCADPD0005279_2D-left.dwg, https://download.schneider-electric.com/files?p_Doc_Ref=MCADPD0005279_3D-CAD&p_File_name=MCADPD0005279_2D-left.dxf, https://download.schneider-electric.com/files?p_Doc_Ref=MCADPD0005279_3D-CAD&p_File_name=MCADPD0005279_2D-right.dwg, https://download.schneider-electric.com/files?p_Doc_Ref=MCADPD0005279_3D-CAD&p_File_name=MCADPD0005279_2D-right.dxf, https://download.schneider-electric.com/files?p_Doc_Ref=MCADPD0005279_3D-CAD&p_File_name=MCADPD0005279_2D-top.dwg, https://download.schneider-electric.com/files?p_Doc_Ref=MCADPD0005279_3D-CAD&p_File_name=MCADPD0005279_2D-top.dxf
  • Conformance Attributes
    • Product Certifications : CCC, CSA, EAC, UL
    • Standards : EN/IEC 60947-1, EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1
  • Complementary Attributes
    • Maximum Horse Power Rating : 2 hp at 240 V AC 60 Hz for 3 phase motors, 0.33 hp at 120 V AC 60 Hz for 1 phase motors, 1 hp at 240 V AC 60 Hz for 1 phase motors, 2 hp at 208 V AC 60 Hz for 3 phase motors, 5 hp at 480 V AC 60 Hz for 3 phase motors, 7.5 hp at 600 V AC 60 Hz for 3 phase motors
    • Ie Rated Operational Current : 9 A (at <50 °C) at <= 440 V AC-3, 15 A (at <50 °C) at <= 440 V AC-1, 15 A (at <50 °C) AC-3e
    • Ue Rated Operational Voltage : <= 690 V AC 47...63 Hz, <= 690 V AC 47...63 Hz, <= 690 V AC 47...63 Hz, <= 690 V AC 47...63 Hz, <= 690 V AC 47...63 Hz, <= 690 V AC 47...63 Hz
    • Ui Rated Insulation Voltage : 690 V IEC 60947-4-1, 600 V UL 60947-4-1, 600 V CSA C22.2 No 60947-4-1
    • Uc Control Circuit Voltage : 24 V DC supplied by the bus coupler
    • Uimp Rated Impulse Withstand Voltage : 6 kV
  • Important Information Attributes
    • Electromagnetic Compatibility : electrostatic discharge immunity test, level 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2, radiated RF field immunity test, level 3, 10 V/m, conforming to EN/IEC 61000-4-3, fast transient immunity test, level 4, 4 kV, conforming to EN/IEC 61000-4-4, surge immunity test (differential mode), level 3, 2 kV, conforming to EN/IEC 61000-4-5, surge immunity test (common mode), level 4, 4 kV, conforming to EN/IEC 61000-4-5, conducted RF disturbance immunity test, 20 V, conforming to EN/IEC 61000-4-6
    • Fire Resistance : 960 °C UL 94, 850 °C IEC 60695-2-1, 650 °C IEC 60695-2-12
    • Function Available : upstream voltage presence detection, electronic thermal overload protection, monitoring of currents, control of third party power devices when associated to TPRDG IO module
    • Local Signalling : 1 LED (green/red) for DS (device status), 1 LED (green/red) for LS (load status)
    • Metering Type : time device ON, number of faults, number of device power cycles, average current Iavg, average voltage Vavg, max current Imax, max voltage Vmax
    • Motor Power Kw : 2.2 kW at 230 V AC 50 Hz, 4 kW at 380...415 V AC 50 Hz, 4 kW at 440 V AC 50 Hz, 5.5 kW at 500 V AC 50 Hz, 5.5 kW at 690 V AC 50 Hz
    • Protection Type : thermal overload protection, motor overheat, overcurrent, undercurrent, jam, long start, stall, rapid cycle lockout, phase loss, rapid restart lockout, phase reversal, phase unbalance, phase sequence, ground current
    • Tightening Torque : 1.7-1.7 N.m flat Ø 6 mm, 1.7-1.7 N.m Philips No 2
    • Vibration Resistance : 1.5 mm peak to peak 3-13 Hz) IEC 60068-2-6, 1 gn 13-200 Hz) IEC 60068-2-6
    • Connections Terminals : screw-clamp terminals 2 1.5-4 mm² AWG 16...AWG 12)flexible without cable end, screw-clamp terminals 1 1-4 mm² AWG 16...AWG 12)rigid, screw-clamp terminals 2 1-4 mm² AWG 16...AWG 12)rigid, screw-clamp terminals 1 1.5-4 mm² AWG 16...AWG 12)flexible without cable end, screw-clamp terminals 1 1-4 mm² AWG 16...AWG 12)flexible with cable end, screw-clamp terminals 2 1-2.5 mm² AWG 16...AWG 14)flexible with cable end
    • Ie Rated Operational Current : 9 A (at <50 °C) at <= 440 V AC-3, 15 A (at <50 °C) at <= 440 V AC-1, 15 A (at <50 °C) AC-3e
    • Medium Desc : Power module, TeSys island, 15A at AC-1, 9A at AC-3, 4kW, 5hp
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-02-26
    • Global Commercial Status : Commercialised
    • Return Indicator : Y
    • Stocking Flag : N
    • Device Type : Relay, Control & Measurement - measuring, monitoring device
    • Serviceability : No
    • Traceability : No
    • Weee Applicability : Finished product
    • Weee Scope : In
    • Legacy Weee Scope : In
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI1904009EN
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : Yes
    • Rohs Eur Status : Compliant By Exemption
    • Rohs Eur Full Compliance Status : Compliant By Exemption
    • China Rohs In Scope : Yes
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Product Kit Identifier : N
    • Current Consumption : 60 mA
    • Device Short Name : TPRPM
    • Energy Efficiency Optimized : False
    • Halogen Free Status : Halogen free plastic parts product
    • Mounting Mode : horizontal and vertical 35 mm symmetrical DIN rail)
    • Overvoltage Category : III
    • Poles Description : 3P
    • Power Dissipation In W : 0.6 W at Ie AC-3
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Name : TeSys island
    • Product Or Component Type : power module
    • Protective Treatment : TC
    • Range Of Product : TeSys
    • Reset : remotely or automatically
    • Returnability : Yes
    • Shock Resistance : 15 gn 11 ms) IEC 60068-2-27
    • Sustainable Packaging : Yes
    • Thermal Overload Class : class 5…30
    • Thermal Protection Adjustment Range : 0.18-9 A
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Ith Conventional Free Air Thermal Current : 15 A (at 50 °C)
    • Pep Code : ENVPEP1904009EN
    • Height Nominal : 121 mm
    • Width Nominal : 45 mm
  • Environment Attributes Main
    • Ambient Air Temperature For Operation : -10-50 °C without derating, -10-50 °C without derating, -10-50 °C without derating, -10-50 °C without derating, 50-60 °C with current derating
    • Ambient Air Temperature For Storage : -25-70 °C, -25-70 °C
    • Product Compatibility : TPRBC bus coupler, TPRDG digital IO module, TPRAN analog IO module
    • Take Back : Nej
    • Halogene Performance : Halogen free plastic parts product
    • Recycled Metal Content At Cr Level : 0 %
    • China Rohs Regulation : X
    • Mercury Free : Yes
    • Circularity Profile : ENVEOLI1904009EN
    • Environmental Disclosure : ENVPEP1904009EN
    • Eu Rohs Directive : Compliant By Exemption
    • Halogen Content Performance : Halogen free plastic parts product
    • Ip Degree Of Protection : IP20
    • Operating Altitude : 0...6561.68 ft (0...2000 m) without derating
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Relative Humidity : 5-95 %
    • Pep Code : ENVPEP1904009EN
  • General Attributes
    • Product Or Component Type : power module
    • Range Of Product : TeSys
  • ETIM
    • ETIM 8 : EC001605
    • ETIM 9 : EC001605
  • Specifications
    • Depth : 115 mm
  • Overview Attributes
    • Device Presentation : power module connected to an automation controller through a bus coupler, operational only when connected to a bus coupler