Power module, TeSys island, 15A at AC-1, 9A at AC-3, 4kW, 5hp

POWER INTERFACE MODULE, TESYS

SQDTPRPM009 TPRPM009 SQDTPRPM009
266.78 / EA
http://schema.org/OutOfStock
  • Country of Origin: France
  • Depth: 115 mm
  • Height: 121 mm
  • Net Weight: 0.255 kg
  • Weight: 0.255 kg
  • Width: 45 mm
TeSys island power module, 3 poles, 9A/690V. Connected to a TPRBC bus coupler it protects and monitors loads up to 9A and motors up to 4kW@400V / 5hp@480V. External power switching devices could be controlled if associated to a digital IO module TPRDG4X2. It provides motor protection functions including thermal overload (setting 0.18-9A, tripping class 5-30), phase loss, phase unbalance and reversal, long start (stall), locked rotor (jam), rapid cycle lockout, ground current detection. Monitoring of the load includes max/average voltages and currents, number of faults, active and reactive power/energy when associated to a TPRVM001 voltage module. Mounting on DIN rail together with the other modules of the TeSys island configuration. Multi standards certified (IEC, UL, CSA, CCC, EAC).
QTY
  • Product Description
  • Specifications
TeSys island power module, 3 poles, 9A/690V. Connected to a TPRBC bus coupler it protects and monitors loads up to 9A and motors up to 4kW@400V / 5hp@480V. External power switching devices could be controlled if associated to a digital IO module TPRDG4X2. It provides motor protection functions including thermal overload (setting 0.18-9A, tripping class 5-30), phase loss, phase unbalance and reversal, long start (stall), locked rotor (jam), rapid cycle lockout, ground current detection. Monitoring of the load includes max/average voltages and currents, number of faults, active and reactive power/energy when associated to a TPRVM001 voltage module. Mounting on DIN rail together with the other modules of the TeSys island configuration. Multi standards certified (IEC, UL, CSA, CCC, EAC).
  • Specifications
    • Country of Origin : France
    • Width : 45 mm
    • Height : 121 mm
    • Weight : 0.255 kg
    • Current Consumption : 60 mA
    • [Ue] Rated Operational Voltage : <= 690 V AC 47...63 Hz
    • Power Dissipation In W : 0.6 W at Ie AC-3
    • Range Of Product : TeSys
    • Reset : remotely or automatically
    • [Ith] Conventional Free Air Thermal Current : 15 A (at 50 °C)
    • [Uc] Control Circuit Voltage : 24 V DC supplied by the bus coupler
    • Product Or Component Type : power module
    • Product Name : TeSys island
    • Thermal Overload Class : class 5…30
    • [Uimp] Rated Impulse Withstand Voltage : 6 kV
    • Device Presentation : power module connected to an automation controller through a bus coupler || operational only when connected to a bus coupler
    • Function Available : upstream voltage presence detection || electronic thermal overload protection || monitoring of currents || control of third party power devices when associated to TPRDG IO module
    • [Ie] Rated Operational Current : 9 A (at <50 °C) at <= 440 V AC-3 || 15 A (at <50 °C) at <= 440 V AC-1 || 15 A (at <50 °C) AC-3e
    • Thermal Protection Adjustment Range : 0.18-9 A
    • Product Compatibility : TPRBC bus coupler || TPRDG digital IO module || TPRAN analog IO module
    • Overvoltage Category : III
    • Maximum Horse Power Rating : 0.33 hp at 120 V AC 60 Hz for 1 phase motors || 1 hp at 240 V AC 60 Hz for 1 phase motors || 2 hp at 208 V AC 60 Hz for 3 phase motors || 2 hp at 240 V AC 60 Hz for 3 phase motors || 5 hp at 480 V AC 60 Hz for 3 phase motors || 7.5 hp at 600 V AC 60 Hz for 3 phase motors
    • Motor Power Kw : 2.2 kW at 230 V AC 50 Hz || 4 kW at 380...415 V AC 50 Hz || 4 kW at 440 V AC 50 Hz || 5.5 kW at 500 V AC 50 Hz || 5.5 kW at 690 V AC 50 Hz
    • [Ui] Rated Insulation Voltage : 690 V IEC 60947-4-1 || 600 V UL 60947-4-1 || 600 V CSA C22.2 No 60947-4-1
    • Device Short Name : TPRPM
    • Poles Description : 3P
  • Complementary
    • Mounting Mode : horizontal and vertical 35 mm symmetrical DIN rail)
    • Height : 121 mm
    • Product Certifications : CCC || CSA || EAC || UL
    • Standards : EN/IEC 60947-1 || EN/IEC 60947-4-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1
    • Connections - Terminals : screw-clamp terminals 1 1-4 mm² AWG 16...AWG 12)rigid || screw-clamp terminals 2 1-4 mm² AWG 16...AWG 12)rigid || screw-clamp terminals 1 1.5-4 mm² AWG 16...AWG 12)flexible without cable end || screw-clamp terminals 2 1.5-4 mm² AWG 16...AWG 12)flexible without cable end || screw-clamp terminals 1 1-4 mm² AWG 16...AWG 12)flexible with cable end || screw-clamp terminals 2 1-2.5 mm² AWG 16...AWG 14)flexible with cable end
    • Net Weight : 0.255 kg
    • Metering Type : time device ON || number of faults || number of device power cycles || average current Iavg || average voltage Vavg || max current Imax || max voltage Vmax
    • Local Signalling : 1 LED (green/red) for DS (device status) || 1 LED (green/red) for LS (load status)
    • Width : 45 mm
    • Depth : 115 mm
    • Tightening Torque : 1.7-1.7 N.m flat Ø 6 mm || 1.7-1.7 N.m Philips No 2
    • Protection Type : thermal overload protection || motor overheat || overcurrent || undercurrent || jam || long start || stall || rapid cycle lockout || phase loss || rapid restart lockout || phase reversal || phase unbalance || phase sequence || ground current
  • Environmental data
    • Rohs Exemption Information : Yes
    • Packaging Made With Recycled Cardboard : Yes
    • Mercury Free : Yes
    • Environmental Disclosure : ENVPEP1904009EN
    • Halogen Content Performance : Halogen free plastic parts product
    • Packaging Without Single Use Plastic : Yes
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Scip Number : 0bda50ae-711f-4024-bff6-ce0577049f63
    • Circularity Profile : ENVEOLI1904009EN
    • Take-Back : No
    • Sustainable Packaging : Yes
    • Eu Rohs Directive : Compliant with Exemptions
  • Environment
    • Ambient Air Temperature For Operation : -10-50 °C without derating || 50-60 °C with current derating
    • Shock Resistance : 15 gn 11 ms) IEC 60068-2-27
    • Vibration Resistance : 1.5 mm peak to peak 3-13 Hz) IEC 60068-2-6 || 1 gn 13-200 Hz) IEC 60068-2-6
    • Electromagnetic Compatibility : electrostatic discharge immunity test, level 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2 || radiated RF field immunity test, level 3, 10 V/m, conforming to EN/IEC 61000-4-3 || fast transient immunity test, level 4, 4 kV, conforming to EN/IEC 61000-4-4 || surge immunity test (differential mode), level 3, 2 kV, conforming to EN/IEC 61000-4-5 || surge immunity test (common mode), level 4, 4 kV, conforming to EN/IEC 61000-4-5 || conducted RF disturbance immunity test, 20 V, conforming to EN/IEC 61000-4-6
    • Pollution Degree : 2
    • Ambient Air Temperature For Storage : -25-70 °C
    • Protective Treatment : TC
    • Relative Humidity : 5-95 %
    • Ip Degree Of Protection : IP20
    • Operating Altitude : 0...6561.68 ft (0...2000 m) without derating
    • Fire Resistance : 960 °C UL 94 || 850 °C IEC 60695-2-1 || 650 °C IEC 60695-2-12