Panelboard interior, NQ, main lugs, 400A, Al bus, 54 pole spaces, 3 phase, 4 wire, 240 VAC, 48 VDC

Panelboard interior, NQ, main lugs, 400A, Al bus, 54 pole spaces, 3 phase, 4 wire, 240 VAC, 48 VDC

SQDNQ454L4 NQ454L4 785901578109
2287.97 / EA
  • Amperage: 400 A
  • Country of Origin: Mexico
  • Voltage: 240 V, 48 V
NQ Panelboards are versatile panelboards that feature a wide selection of circuit breakers, accessories, and ready to install kits. NQ Panelboards provide 200% rated neutrals for non-linear loads. NQ Panelboards are convertible from main lug to main breaker. Interior has a maximum voltage rating of 240 VAC and 48 VDC. This NQ Panelboard interior has a main lug and is rated at 400 A three phase. Interior has an interrupt current rating of up to 65 kA. This interior is for a 4 wire system with 54 circuits and has an aluminum bus bar. Interior is for QOB, QOBVH and QHB branch circuit breakers. This interior provides protection for your commercial and industrial applications. NQ Panelboard interiors are field convertible to top or bottom feed. Some factory installed options are split bus, lighting contactors, compression lugs, surge protection devices, and phenolic nameplates. Lug connections will accept 1/0 AWG to 750 kcmil aluminum wire. This interior is UL listed and CSA certified. NQ Panelboard interiors can be used for applications such as commercial buildings, industrial buildings, stadiums, and offices.
  • Product Description
  • Specifications
NQ Panelboards are versatile panelboards that feature a wide selection of circuit breakers, accessories, and ready to install kits. NQ Panelboards provide 200% rated neutrals for non-linear loads. NQ Panelboards are convertible from main lug to main breaker. Interior has a maximum voltage rating of 240 VAC and 48 VDC. This NQ Panelboard interior has a main lug and is rated at 400 A three phase. Interior has an interrupt current rating of up to 65 kA. This interior is for a 4 wire system with 54 circuits and has an aluminum bus bar. Interior is for QOB, QOBVH and QHB branch circuit breakers. This interior provides protection for your commercial and industrial applications. NQ Panelboard interiors are field convertible to top or bottom feed. Some factory installed options are split bus, lighting contactors, compression lugs, surge protection devices, and phenolic nameplates. Lug connections will accept 1/0 AWG to 750 kcmil aluminum wire. This interior is UL listed and CSA certified. NQ Panelboard interiors can be used for applications such as commercial buildings, industrial buildings, stadiums, and offices.
  • Offer Sustainability
    • EU RoHs Directive : Compliant
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Nickel compounds, which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
    • Mercury Free : Yes
    • Toxic Heavy Metal Free : Yes
    • REACh Free Of SVHC : Yes
  • Main
    • Branch Circuit Breaker Type : QOB || QOB-VH || QHB
    • Product Or Component Type : Interiors
    • Busbar Material : Aluminium
    • Panelboard Type : Main lugs
  • Ordering And Shipping Details
    • Discount Schedule : PE1A
    • GTIN : 00785901578109
    • Nbr. Of Units In Pkg. : 1
    • Country Of Origin : MX
    • Returnability : Yes
    • Category : 09151 - NQ RTA PANELBOARDS
  • Complementary
    • In Rated Current : 400 A
    • Number Of Phases : 3 phase
    • Tightening Torque : 274.99…300.04 lbf.in (31.07…33.90 N.m) 0.08…0.59 in² (53.48…380 mm²) AWG 1/0...750 kcmil) || 274.99…300.04 lbf.in (31.07…33.90 N.m) 0.08…0.27 in² (53.48…177.3 mm²) AWG 1/0...350 kcmil) || 549.98 lbf.in (62.14 N.m) 0.08…0.59 in² (53.48…380 mm²) AWG 1/0...750 kcmil) || 549.98 lbf.in (62.14 N.m) 0.08…0.24 in² (53.48…152 mm²) AWG 1/0...300 kcmil) || 375.01 lbf.in (42.37 N.m) 0.08…0.59 in² (53.48…380 mm²) AWG 1/0...750 kcmil) || 375.01 lbf.in (42.37 N.m) 0.08…0.24 in² (53.48…152 mm²) AWG 1/0...300 kcmil)
    • Iu Rated Interrupted Current : 10 kA || 22 kA || 65 kA
    • Voltage Rating : 240 V AC || 48 V DC
    • Number Of Spaces : 54
    • Connections - Terminals : Lug line AWG 1/0...750 kcmil aluminium || Lug neutral AWG 1/0...750 kcmil aluminium
    • Wiring Configuration : 4-wire