Panelboard interior, NQ, main lugs, 225A, Al bus, 84 pole spaces, 1 phase, 3 wire, 240 VAC, 48 VDC

Panelboard interior, NQ, main lugs, 225A, Al bus, 84 pole spaces, 1 phase, 3 wire, 240 VAC, 48 VDC

SQDNQ84L2 NQ84L2 785901498148
2835.10 / EACH
  • Amperage: 225 A
  • Country of Origin: Mexico
  • Height: 1143.00 mm, 45 in
  • Number of Phases: 1
  • Standard: CSA, UL
  • Voltage: 240 V, 48 V
  • Warranty Length: 18 mth
  • Width: 10.44 in, 265.18 mm
NQ Panelboard interiors can be used for applications such as commercial buildings, industrial buildings, stadiums, and offices. NQ Panelboards are versatile panelboards that feature a wide selection of circuit breakers, accessories, and ready to install kits. NQ Panelboard interiors are field convertible to top or bottom feed. NQ Panelboards are convertible from main lug to main breaker. NQ Panelboards provide 200% rated neutrals for nonlinear loads. Some factory installed options are split bus, lighting contactors, compression lugs, surge protection devices, and phenolic nameplates. This interior provides protection for your commercial and industrial applications. The main lugs are rated at 225A, 240 VAC single phase or 48 VDC. Interior has an interrupt current rating of up to 65 kA. This interior is for a 3 wire system with 84 spaces and has an aluminum bus bar. Interior is for QOB, QOBVH and QHB branch circuit breakers. Interior is 45 inches tall and 10.44 inches wide. This NQ panelboard interior is UL listed and CSA certified.
  • Product Description
  • Specifications
NQ Panelboard interiors can be used for applications such as commercial buildings, industrial buildings, stadiums, and offices. NQ Panelboards are versatile panelboards that feature a wide selection of circuit breakers, accessories, and ready to install kits. NQ Panelboard interiors are field convertible to top or bottom feed. NQ Panelboards are convertible from main lug to main breaker. NQ Panelboards provide 200% rated neutrals for nonlinear loads. Some factory installed options are split bus, lighting contactors, compression lugs, surge protection devices, and phenolic nameplates. This interior provides protection for your commercial and industrial applications. The main lugs are rated at 225A, 240 VAC single phase or 48 VDC. Interior has an interrupt current rating of up to 65 kA. This interior is for a 3 wire system with 84 spaces and has an aluminum bus bar. Interior is for QOB, QOBVH and QHB branch circuit breakers. Interior is 45 inches tall and 10.44 inches wide. This NQ panelboard interior is UL listed and CSA certified.
  • Ordering And Shipping Details
    • Country Of Origin : MX
    • Returnability : Yes
    • Category : 09151 - NQ RTA PANELBOARDS
    • Discount Schedule : PE1A
    • GTIN : 00785901498148
    • Nbr. Of Units In Pkg. : 1
  • Environment
    • Standards : UL || CSA
  • Offer Sustainability
    • Green Premium Status : Green Premium product
    • Toxic Heavy Metal Free : Yes
    • REACh Free Of SVHC : Yes
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Nickel compounds, which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
    • EU RoHs Directive : Compliant
    • Mercury Free : Yes
  • Contractual Warranty
    • Warranty : 18 months
  • Complementary
    • Width : 10.44 in (265.18 mm)
    • Enclosure Nominal Height : 50 in (1270.00 mm)
    • Number Of Phases : 1 phase
    • Wiring Configuration : 3-wire
    • Iu Rated Interrupted Current : 10 kA || 22 kA || 65 kA
    • In Rated Current : 225 A
    • Enclosure Nominal Width : 20 in (508.00 mm)
    • Tightening Torque : 40.01…50.01 lbf.in (4.52…5.65 N.m) 0.02…0.10 in² (13.30…67.43 mm²) AWG 6...AWG 2/0) || 100.01 lbf.in (11.3 N.m) 0.02…0.10 in² (13.30…67.43 mm²) AWG 6...AWG 2/0) || 274.99 lbf.in (31.07 N.m) 0.02…0.27 in² (13.30…177.3 mm²) AWG 6...350 kcmil) || 274.99 lbf.in (31.07 N.m) 0.02…0.20 in² (13.30…126.7 mm²) AWG 6...250 kcmil) || 274.99 lbf.in (31.07 N.m) 0.17…0.24 in² (107.2…152 mm²) AWG 4...300 kcmil)
    • Voltage Rating : 240 V AC || 48 V DC
    • Enclosure Nominal Depth : 5.75 in (146.05 mm) NEMA 1 || 6.5 in (165.10 mm) NEMA 3R/5/12
    • Number Of Spaces : 84
    • Height : 45 in (1143.00 mm)
  • Main
    • Panelboard Type : Main lugs
    • Busbar Material : Aluminium
    • Branch Circuit Breaker Type : QOB || QOB-VH || QHB