Load center interior, QO, main breaker, 400A, Al bus, 42 pole spaces, 1 phase, 3 wire, NQ enclosure

NQ 400A 42 CKT MB 1PH AL

SQDQONQ42MS400 QONQ42MS400 785901811831
3809.55 / EACH
http://schema.org/OutOfStock
  • Circuit Breaker Type: QHB, QOB, QOB-VH
  • Line Rated Current: 400 A
  • Material: Aluminum
  • Net Weight: 19.051 kg
  • Number of Phases: 1
  • Standard: CSA, UL
  • Warranty Length: 18 mth
QO load centers offer premium features by allowing QO breakers, ground arc fault interrupters arc fault interrupters and surge arresters to be installed inside QO load centers enable the use of a full complement of accessories. Systems can be single or three phase and have indoor and outdoor versions. This load center interior has a high amperage fixed main with factory installed main lugs that are rated for 400 A. This interior has 42 spaces and has a 65 kA breaking capacity. The main lugs will accept 1/0 AWG to 750 kcmil copper or aluminum wire. This interior is UL component recognized and cUL certified. It is encased in a NQ enclosure.
QTY
  • Product Description
  • Specifications
QO load centers offer premium features by allowing QO breakers, ground arc fault interrupters arc fault interrupters and surge arresters to be installed inside QO load centers enable the use of a full complement of accessories. Systems can be single or three phase and have indoor and outdoor versions. This load center interior has a high amperage fixed main with factory installed main lugs that are rated for 400 A. This interior has 42 spaces and has a 65 kA breaking capacity. The main lugs will accept 1/0 AWG to 750 kcmil copper or aluminum wire. This interior is UL component recognized and cUL certified. It is encased in a NQ enclosure.
  • Environment
    • Standards : CSA || UL
  • Contractual warranty
    • Warranty : 18 months
  • Offer Sustainability
    • Rohs Exemption Information : Yes
    • Mercury Free : Yes
    • Environmental Disclosure : ENVPEP2212001
    • Sustainable Offer Status : Green Premium product
    • Toxic Heavy Metal Free : Yes
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • Reach Free Of Svhc : Yes
    • China Rohs Regulation : Pro-active China RoHS declaration (out of China RoHS legal scope)
    • Circularity Profile : N/A
    • Eu Rohs Directive : Compliant
  • Complementary
    • Tightening Torque : 4.52-5.65 N.m 13.30-67.43 mm² (AWG 6...AWG 2/0) || 11.3-11.3 N.m 13.30-67.43 mm² (AWG 6...AWG 2/0) || 31.07-31.07 N.m 13.30-177.3 mm² (AWG 6...350 kcmil) || 31.07-31.07 N.m 13.30-126.7 mm² (AWG 6...250 kcmil) || 31.07-31.07 N.m 107.2-152 mm² (AWG 4...300 kcmil)
    • [Iu] Rated Interrupted Current : 10 kA || 22 kA || 65 kA
    • Number Of Spaces : 42
    • Enclosure Nominal Height : 62 in
    • Phase : 1 phase
    • Net Weight : 19.051 kg
    • Enclosure Nominal Depth : 5.75 in NEMA 1 || 6.5 in NEMA 3R/5/12
    • Line Rated Current : 400 A
    • Wiring Configuration : 3-wire
    • Enclosure Nominal Width : 20 in
    • [Ue] Rated Operational Voltage : 240 V AC
  • Specifications
    • Circuit Breaker Type : QOB || QOB-VH || QHB
    • Product Or Component Type : Load Center Interior
    • Material : aluminium
    • Load Center Type : main breaker