SQUARE D

Circuit breaker, PowerPacT R, 1600A, 3 pole, 600VAC, 25kA, busbar, ET 1.0I, 80%

MOLDED CASE CIRCUIT BREAKER 60

SQDRJF36160 RJF36160 785901566571
24750.01 / EACH
http://schema.org/OutOfStock
  • Country of Origin: Mexico
  • Depth: 14.49 in
  • Warranty Length: 18 mth
PowerPacT R-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT R-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has an electronic trip unit, ET 1.0I. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT R circuit breakers are available in 2, 3, and 4-pole unit mount and I-Line construction (I-Line construction is available for 1000A and 1200A rated circuit breakers only). This unit has a busbar connection. This PowerPacT P, 1600A, 3 pole, circuit breaker has an interrupting rating of 25kA at 600VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT R circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
QTY
  • Product Description
  • Features
  • Specifications
PowerPacT R-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT R-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has an electronic trip unit, ET 1.0I. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT R circuit breakers are available in 2, 3, and 4-pole unit mount and I-Line construction (I-Line construction is available for 1000A and 1200A rated circuit breakers only). This unit has a busbar connection. This PowerPacT P, 1600A, 3 pole, circuit breaker has an interrupting rating of 25kA at 600VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT R circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
  • Prop 65
    • WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Physical Attributes
    • Wire Stripping Length : 35 mm
  • Complementary Attributes
    • Line Rated Current : 1600-1600 A
  • Important Information Attributes
    • Persona Type Ids : LC, OM, OM8, PB
    • Persona Type Names : Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Electrical Connection : busbar connection, line, busbar connection, load
    • Number Of Slots : 2 auxiliary switch OF plug-in), 1 alarm switch SD plug-in)1 voltage release MN or MX plug-in)
    • Tightening Torque : 68-68 N.m 50-400 mm² (1/0 AWG...750 kcmil), 68-68 N.m 50-150 mm² (2 x 1/0 AWG...2 x 300 kcmil)
    • Certificate Agency : UL, CSA, NOM
    • Carbon Footprint Of The Distribution Phase [A4] : 8.9135333084958, 9 kg CO2 eq.
    • Carbon Footprint Of The End-of-life Phase [C1 To C4] : 39 kg CO2 eq., 39.38424224706876
    • Carbon Footprint Of The Installation Phase [A5] : 6.141401004171242, 6 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase [A1 To A3] : 141 kg CO2 eq., 141.48623260127061
    • Carbon Footprint Of The Use Phase [B2 B3 B4 B6] : 2 438 kg CO2 eq., 2438.4759328388213
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-11-13
    • Return Indicator : Y
    • Stocking Flag : Y
    • Stock Policy : 1
    • Device Type : LV equipment - Low voltage circuit breaker
    • Serviceability : Yes
    • Traceability : Yes
    • Field Service Division : PPIBS
    • Average Life Duration : 15 year(s)
    • Weee Scope : In
    • Weee Product Category : 4
    • Scope Perimeter : Outside of Europe
    • Eoli Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI2206034_V2
    • Rohs Eur In Scope : Yes
    • Rohs Eur Status : Compliant By Exemption
    • Rohs Eur Conformity Date : 1909
    • Rohs Eur Full Compliance Status : Compliant By Exemption
    • China Rohs In Scope : Yes
    • China Rohs Label : 7
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : No
    • Product Contributes To Saved And Avoided Emissions : No
    • Tier Id : 1
    • Tier : 1
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Product Kit Identifier : N
    • Awg Gauge : 3/0 AWG...750 kcmil aluminium/copper
    • Circuit Breaker Application : HACR rated
    • Continuous Current Rating : 80 %
    • Control Type : operating handle
    • Device Application : distribution
    • Energy Efficiency Optimized : False
    • Local Signalling : trip indicator
    • Magnetic Tripping Current : 2400-19200 A
    • Mounting Mode : unit mount busbar)
    • Mounting Support : busbar
    • Network Frequency : 50/60 Hz
    • Number Of Poles : 3P
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Name : PowerPact R
    • Product Or Component Type : circuit breaker
    • Quality Labels : CE
    • Quantity Per Set : 1
    • Range : PowerPact
    • Returnability : Yes
    • Software Version : v6.2.5-6
    • Suitability For Isolation : yes IEC 60947-2
    • Sustainable Packaging : No
    • Terminal Identifier : AL2500RK
    • Total Lifecycle Carbon Footprint : 2 634 kg CO2 eq.
    • Trip Unit Name : ET 1.0I
    • Trip Unit Technology : electronic, basic, ET 1.0I, I
    • Utilisation Category : category A
    • Pep Code : ENVPEP2206034EN
    • Database Version : 2024-01
    • Pep Verification Date : 2025-07-03
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent external review
    • Data Source : extrapolated product
    • Functional-unit Description : Protect the installation from overloads and short circuits in a circuit with rated voltage Ue, rated current In, with Np poles, a rated breaking capacity Icu, and, if applicable, the specific specifications, in the Industrial application area, according to the appropriate use scenario, and during the reference service life of the product of 20 years.
    • Functional-unit Quantity : 1
    • Functional-unit Unit : unit
    • Reference Lifetime In Y : 20
    • Energy Model - Manufacturing [A1-a3] : Electricity Mix; Low voltage; 2020; United States, US
    • Energy Model - Installation [A5] : [A5]
    • Energy Model - Use [B6] : Electricity Mix; Low voltage; 2020; United States, US
    • Energy Model - End Of Life [C1-c4] : [C1 - C4]
    • Recyclability Potential In % : 88
    • Height Nominal : 16.24 in
    • Width Nominal : 16.53 in
    • [Ics] Rated Service Breaking Capacity : 35 kA 240 V AC 50/60 Hz IEC 60947-225 kA 380/415 V AC 50/60 Hz IEC 60947-2
    • [Ue] Rated Operational Voltage : 600 V AC 50/60 Hz UL 489
    • [Ui] Rated Insulation Voltage : 750 V IEC 60947-2
    • [Uimp] Rated Impulse Withstand Voltage : 8 kV IEC 60947-2
    • Halogen-free Status : Halogen free plastic parts product
    • Nbr. Of Units In Pkg. : 1
    • Package Weight(Lbs) : 30.844 kg
    • Take-back : No
    • Warranty (In Months) : 18
    • Customs Code : 8536200020
  • Environment Attributes Main
    • Ambient Air Temperature For Operation : -25-70 °C, -25-70 °C
    • Ambient Air Temperature For Storage : -50-85 °C, -50-85 °C
    • Operating Altitude : < 6561.68 ft (2000 m) without derating, < 6561.68 ft (2000 m) without derating< 6561.68 ft (2000 m) without derating, < 6561.68 ft (2000 m) without derating13123.36 ft (4000 m) with derating
    • Take Back : No
    • Halogene Performance : Halogen free plastic parts product
    • Recycled Metal Content At Cr Level : 0 %
    • China Rohs Regulation : X
    • Mercury Free : Yes
    • Carbon Footprint : 2634.4013419998278
    • Circularity Profile : ENVEOLI2206034_V2
    • Environmental Disclosure : ENVPEP2206034EN
    • Eu Rohs Directive : Compliant By Exemption
    • Halogen Content Performance : Halogen free plastic parts product
    • Ip Degree Of Protection : IP40
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : No
    • Pep Code : ENVPEP2206034EN
    • Pep Verification Date : 2025-07-03
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent external review
  • General Attributes
    • Product Or Component Type : circuit breaker
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Specifications
    • Country of Origin : Mexico
    • Depth : 14.49 in
  • Batteries & Runtime Attributes
    • Removable Battery : Yes