Circuit breaker, PowerPacT R, 1600A, 2 pole, 600VAC, 18kA, busbar, ET 1.0I, 80%

Circuit breaker, PowerPacT R, 1600A, 2 pole, 600VAC, 18kA, busbar, ET 1.0I, 80%

SQDRGF26160 RGF26160 SQDRGF26160
12270.38 / EA
http://schema.org/OutOfStock
  • Certifications: CSA, NOM, UL
  • Depth: 14.49 in
  • Height: 16.24 in
  • Line Rated Current: 1600-1600 A
  • Mounting Type: Unit Mount Busbar)
  • Net Weight: 52 lb
  • Standard: CSA, IEC 60947-2, NEMA, NMX J-266, UL
  • Storage Temperature: -50-85 °C
  • Strip Length: 35 mm
  • Trip Point: 2400-19200 A
  • Warranty Length: 18 mth
  • Width: 16.53 in
PowerPacT R-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT R-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has an electronic trip unit, ET 1.0I. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT R circuit breakers are available in 2, 3, and 4-pole unit mount and I-Line construction (I-Line construction is available for 1000A and 1200A rated circuit breakers only). This unit has a busbar connection. This PowerPacT P, 1600A, 2 pole, circuit breaker has an interrupting rating of 18kA at 600VAC. The circuit breaker has a continuous current rating of 80%. PowerPacT R circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
QTY
  • Product Description
  • Specifications
PowerPacT R-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT R-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has an electronic trip unit, ET 1.0I. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT R circuit breakers are available in 2, 3, and 4-pole unit mount and I-Line construction (I-Line construction is available for 1000A and 1200A rated circuit breakers only). This unit has a busbar connection. This PowerPacT P, 1600A, 2 pole, circuit breaker has an interrupting rating of 18kA at 600VAC. The circuit breaker has a continuous current rating of 80%. PowerPacT R circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
  • Environment
    • Ambient Air Temperature For Operation : -25-70 °C
    • Pollution Degree : 3 IEC 60947-1
    • Ambient Air Temperature For Storage : -50-85 °C
    • Standards : UL || CSA || NEMA || NMX J-266 || IEC 60947-2
    • Quality Labels : CE
    • Product Certifications : UL || CSA || NOM
    • Operating Altitude : < 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
    • Ip Degree Of Protection : IP40
  • Contractual warranty
    • Warranty : 18 months
  • Offer Sustainability
    • China Rohs Regulation : Product out of China RoHS scope. Substance declaration for your information.
    • Circularity Profile : ENVEOLI2206034EN
    • Rohs Exemption Information : Yes
    • Mercury Free : Yes
    • Environmental Disclosure : ENVPEP2206034EN
    • Sustainable Offer Status : Green Premium product
    • Pvc Free : Yes
    • Eu Rohs Directive : Compliant with Exemptions
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
    • Halogen Content Performance : Halogen free plastic parts product
  • Complementary
    • Circuit Breaker Application : HACR rated
    • Mounting Mode : unit mount busbar)
    • Network Frequency : 50/60 Hz
    • Wire Stripping Length : 35 mm
    • Terminal Identifier : AL2500RK
    • Utilisation Category : category A
    • Line Rated Current : 1600-1600 A
    • [Ics] Rated Service Breaking Capacity : 25 kA 240 V AC 50/60 Hz IEC 60947-2 || 20 kA 380/415 V AC 50/60 Hz IEC 60947-2
    • Trip Unit Technology : electronic, basic, ET 1.0I, I
    • Trip Unit Name : ET 1.0I
    • Height : 16.24 in
    • Continuous Current Rating : 80 %
    • Breaking Capacity : AIR 65 kA 240 V AC 50/60 Hz UL 489 || AIR 35 kA 480 V AC 50/60 Hz UL 489 || AIR 18 kA 600 V AC 50/60 Hz UL 489 || Icu 50 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 35 kA 380/415 V AC 50/60 Hz IEC 60947-2
    • [Ui] Rated Insulation Voltage : 750 V IEC 60947-2
    • Suitability For Isolation : yes IEC 60947-2
    • [Ue] Rated Operational Voltage : 600 V AC 50/60 Hz UL 489
    • Tightening Torque : 62-62 N.m 50-400 mm² (AWG 1/0...750 kcmil) || 62-62 N.m 50-150 mm² (2 x AWG 1/0...2 x 300 kcmil)
    • Mounting Support : busbar
    • Breaking Capacity Code : G
    • Magnetic Tripping Current : 2400-19200 A
    • Poles Description : 2P
    • Local Signalling : trip indicator
    • Quantity Per Set : 1
    • Number Of Slots : 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 voltage release MN or MX plug-in)
    • Awg Gauge : AWG 3/0...750 kcmil aluminium/copper
    • Width : 16.53 in
    • Electrical Connection : busbar connection, line || busbar connection, load
    • Depth : 14.49 in
    • Net Weight : 52 lb(US)
    • [Uimp] Rated Impulse Withstand Voltage : 8 kV IEC 60947-2
    • Control Type : operating handle
  • Specifications
    • Product Or Component Type : circuit breaker
    • Product Name : PowerPact R
    • Device Application : distribution
    • Range : PowerPact