Outdoor Connected Cooling Unit

SQDNSYCUHD800DG NSYCUHD800DG 3606486055571
3488.75 / EA
http://schema.org/OutOfStock
  • Depth: 215 mm
  • Height: 30.71 in
  • Material: Steel
  • Width: 13.58 in
This new Outdoor Connected Cooling Unit, designed by Schneider Electric, is perfectly adapted for Automation & Control and Electrical distribution panels, installed outdoor and in harsh environment. It’s smart, compact, and reliable. For international business purpose, it’s compliant to IEC14511 and UL60335-1 & UL60335-2-40. This cooling device is made by Steel protected, offering an internal IP55. Its cooling capacity L35-35 is 875W according to EN 14511. Its power voltage is 230V, 50/60Hz, 1 phase. Its native Modbus connectivity is 100% compatible with any Scada system. Remote alarms and operation data makes manufacturing process more dependable with fewer downtimes, with quicker and easier problem fixing, and electrical components expended lifespan. The new Connected Cooling Units are also associated with Software’s and Services, like ProClima Web or IGE XAO suits. By using these tools, in only few minutes, it’s possible to select and optimize one Thermal management solution, and to design one panel (with its enclosures, devices and Thermal solution), with 3D and 2D drawings. Also, the Schneider Electric EcoStruxure Apps and analytics facilitates process supervision with real life data and action recommendations for more efficient operation and maintenance (preventive and predictive).
QTY
  • Product Description
  • Specifications
This new Outdoor Connected Cooling Unit, designed by Schneider Electric, is perfectly adapted for Automation & Control and Electrical distribution panels, installed outdoor and in harsh environment. It’s smart, compact, and reliable. For international business purpose, it’s compliant to IEC14511 and UL60335-1 & UL60335-2-40. This cooling device is made by Steel protected, offering an internal IP55. Its cooling capacity L35-35 is 875W according to EN 14511. Its power voltage is 230V, 50/60Hz, 1 phase. Its native Modbus connectivity is 100% compatible with any Scada system. Remote alarms and operation data makes manufacturing process more dependable with fewer downtimes, with quicker and easier problem fixing, and electrical components expended lifespan. The new Connected Cooling Units are also associated with Software’s and Services, like ProClima Web or IGE XAO suits. By using these tools, in only few minutes, it’s possible to select and optimize one Thermal management solution, and to design one panel (with its enclosures, devices and Thermal solution), with 3D and 2D drawings. Also, the Schneider Electric EcoStruxure Apps and analytics facilitates process supervision with real life data and action recommendations for more efficient operation and maintenance (preventive and predictive).
  • Physical Attributes
    • Color : Gray RAL 7035)
  • Complementary Attributes
    • Line Rated Current : 2.2 A
    • Rated Power In W : 800 W
  • Important Information Attributes
    • Persona Type Ids : LC, OM, OM8, PB, SI
    • Persona Type Names : Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, System Integrator
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Certificate Agency : UL, IEC, EN
    • Carbon Footprint Of The Distribution Phase [A4] : 2.3315040223446086, 2 kg CO2 eq.
    • Carbon Footprint Of The End-of-life Phase [C1 To C4] : 47 kg CO2 eq., 47.172341804565875
    • Carbon Footprint Of The Installation Phase [A5] : 3.5419562597733694, 4 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase [A1 To A3] : 92 kg CO2 eq., 92.06130220645139
    • Carbon Footprint Of The Use Phase [B2, B3, B4, B6] : 3 034 kg CO2 eq., 3033.6149912760766
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-07-10
    • Return Indicator : N
    • Stocking Flag : Y
    • Stock Policy : 2
    • Weee Scope : In
    • Weee Product Category : 5
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI2301019EN
    • Reach Full Compliance Status : Free of Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : NOT_CONTAINING_SVHC
    • Reach Compliance Directive : Free of Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : Yes
    • Rohs Eur Status : Compliant
    • Rohs Eur Conformity Date : 2327
    • Rohs Eur Full Compliance Status : Compliant
    • China Rohs In Scope : No
    • China Rohs Label : 1
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : No
    • Product Contributes To Saved And Avoided Emissions : No
    • Tier Id : 2
    • Tier : 2
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Product Kit Identifier : N
    • Control Type : electronic controller
    • Cooling Gas Type : R513a 0.130 kg)
    • Cooling Power : 800 W 50/60 Hz L35-L35540 W 50/60 Hz L35-L50
    • Energy Efficiency Ratio : 1.7
    • Incomer Device : M9F23116
    • Inrush Current : 6 A
    • Material : steel
    • Mounting Location : side
    • Mounting Mode : by screws
    • Noise Level : 76 dB
    • Power Consumption In W : 466 W 50/60 Hz, L35-L35513 W 50/60 Hz, L35-L50
    • Pressure : 30 bar
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Destination : for enclosure
    • Product Name : CU
    • Product Or Component Type : cooling unit
    • Protection Type : 15 A (T)
    • Range : ClimaSys
    • Returnability : No
    • Software Version : v6.2.5-6
    • Sustainable Packaging : No
    • Temperature Setting Range : 20-50 °C 50/60 Hz
    • Total Lifecycle Carbon Footprint : 3 179 kg CO2 eq.
    • Type Of Ventilation Filter : external circuit
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Pep Code : ENVPEP2301019EN
    • Database Version : 2024-01
    • Pep Verification Date : 2025-12-01
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0013-ed3-EN-2023 06 06
    • Type Of Verification For The Pep : Independent external review
    • Data Source : extrapolated product
    • Functional-unit Description : To produce 2 kW of cooling, according to the appropriate usage scenario defined in the EN 14825 standard and during the 22-year reference lifetime of the product.& 10& 10- Product dimensions 1000mm x 405mm x 225mm& 10- IP55 conforming to IEC 60529 (on the internal circuit)& 10- IP24 conforming to IEC 60529 (on the external circuit)& 10- Technology: Air/Air& 10- Non-reversible& 10- Cooling capacity - 2kW& 10- SEER - 1.9806& 10- Refrigerant used - R513a& 10- Refill threshold - Cannot Refill& 10- Where Used - Industrial
    • Functional-unit Quantity : 1
    • Functional-unit Unit : unit
    • Reference Lifetime, In Y : 22
    • Energy Consumption On Product Lifetime, In Kwh : 7542.113
    • Energy Model - Manufacturing [A1-a3] : Electricity Mix; Low voltage; 2020; Malta, MT
    • Energy Model - Installation [A5] : Electricity Mix; Low voltage; 2020; Europe, EU-27
    • Energy Model - Use [B6] : Electricity Mix; Low voltage; 2020; Europe, EU-27
    • Energy Model - End Of Life [C1-c4] : Electricity Mix; Low voltage; 2020; Europe, EU-27
    • Recyclability Potential, In % : 89
    • Height Nominal : 780 mm
    • Height Useful : 780 mm
    • Width Nominal : 345 mm
    • Width Real : 345 mm
    • [Us] Rated Supply Voltage : 220...240 V 1 phase 50 Hz EN/IEC230 V +/- 6 % 1 phase 60 Hz UL
    • F-gas Free : Product containing F-gas
    • F-gas Usage Performance : Product containing F-gas
    • Nbr. Of Units In Pkg. : 1
    • Package Weight(Lbs) : 24.400 kg
    • Take-back : No
    • Warranty (In Months) : 18
    • Other Technical Guide : CPTG001_EN
    • Customs Code : 8415103040
  • Environment Attributes Main
    • China Rohs Regulation : Product out of China RoHS scope , Pro-active China RoHS declaration (out of China RoHS legal scope)
    • Directives : 2006/42/EC - machinery, 2014/30/EU - electromagnetic compatibility, 2011/65/EU - RoHS
    • Take Back : No
    • Reach Free Shvc : Yes
    • Recycled Metal Content At Cr Level : 0 %
    • Carbon Footprint : 3178.7220955692114
    • Air Flow : internal circuit 330 m3/h 50/60 Hzexternal circuit 530 m3/h 50/60 Hz
    • Ambient Air Temperature For Operation : inside the enclosure 20-50 °C 50/60 Hzoutside the enclosure -20-55 °C 50/60 Hz
    • Circularity Profile : ENVEOLI2301019EN
    • Environmental Disclosure : ENVPEP2301019EN
    • Eu Rohs Directive : Compliant
    • Ip Degree Of Protection : IP55 IEC 60529 on the internal circuit)IP24 IEC 60529 on the external circuit)
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : No
    • Reach Free Of Svhc : Yes
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP2301019EN
    • Pep Verification Date : 2025-12-01
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0013-ed3-EN-2023 06 06
    • Type Of Verification For The Pep : Independent external review
  • General Attributes
    • Product Or Component Type : cooling unit
  • ETIM
    • ETIM 8 : EC000855
    • ETIM 9 : EC000855
  • Surge Protection And Filtering Attributes
    • Type Of Ventilation Filter : external circuit
  • Specifications
    • Country of Origin : Malta
    • Height : 30.71 in
    • Width : 13.58 in
    • Depth : 215 mm