NEMA Motor Starter, Type S, nonreversing, Size 6, 540A, 400 HP at 460 VAC, up to 100 kA SCCR, 3 phase, 3 pole, Motor Logic, 120 VAC coil, open

NEMA Motor Starter, Type S, nonreversing, Size 6, 540A, 400 HP at 460 VAC, up to 100 kA SCCR, 3 phase, 3 pole, Motor Logic, 120 VAC coil, open

SQD8536SHO2V02H30S 8536SHO2V02H30S 785901924609
20589.97 / EACH
  • Certifications: CSA, NEMA, UL Listed
  • Contact Configuration: Without
  • Depth: 253 mm
  • Height: 713 mm
  • Line Rated Current: 540 A
  • NEMA: 6
  • Number of Phases: 3
  • Warranty Length: 18 mth
  • Width: 268 mm
Type S NEMA motor starters are used for full voltage starting and stopping of AC squirrel cage motors. Type S motor starters have ratings up to 810 amperes. This 3 pole NEMA Size 6 non-reversing starter has a 540 ampere rating. This NEMA Size 6 motor starter has 3 phase ratings of 150 HP at 200 VAC, 200 HP at 230 VAC and 400 HP at 460 and 575 VAC. This non-reversing NEMA motor starter has a Motor Logic overload relay with a 180A to 540A range to sense over current conditions. This NEMA starter has a 65 kA maximum SCCR (Short Circuit Current Rating) per UL508A when protected by an appropriate circuit breaker. This NEMA starter has a 100 kA maximum SCCR per UL508A when protected by an appropriate fuse. Type S motor starters are available with replaceable coils in a wide variety of voltages. This starter has a 110/120 VAC 50/60 Hz operating coil wired for separate control. This NEMA starter is an open device without an enclosure. This starter is 28.06 inches tall, 12.34 inches wide and 9.00 inches deep. A wide variety of accessories are available for Type S starters. Type S non-reversing NEMA motor starters are UL listed and CSA certified.
  • Product Description
  • Specifications
Type S NEMA motor starters are used for full voltage starting and stopping of AC squirrel cage motors. Type S motor starters have ratings up to 810 amperes. This 3 pole NEMA Size 6 non-reversing starter has a 540 ampere rating. This NEMA Size 6 motor starter has 3 phase ratings of 150 HP at 200 VAC, 200 HP at 230 VAC and 400 HP at 460 and 575 VAC. This non-reversing NEMA motor starter has a Motor Logic overload relay with a 180A to 540A range to sense over current conditions. This NEMA starter has a 65 kA maximum SCCR (Short Circuit Current Rating) per UL508A when protected by an appropriate circuit breaker. This NEMA starter has a 100 kA maximum SCCR per UL508A when protected by an appropriate fuse. Type S motor starters are available with replaceable coils in a wide variety of voltages. This starter has a 110/120 VAC 50/60 Hz operating coil wired for separate control. This NEMA starter is an open device without an enclosure. This starter is 28.06 inches tall, 12.34 inches wide and 9.00 inches deep. A wide variety of accessories are available for Type S starters. Type S non-reversing NEMA motor starters are UL listed and CSA certified.
  • Control Type : no control units
  • [Uc] Control Circuit Voltage : 110 V AC 50 Hz || 120 V AC 60 Hz
  • Product Certifications : UL Listed || CSA || NEMA
  • Provided Equipment : 2 fuses (primary), 2 fuses (secondary)
  • Range Of Product : S
  • Maximum Depth : 253 mm
  • Poles Description : 3P
  • Control Circuit : control circuit transformer
  • [Ue] Rated Operational Voltage : 600 V AC
  • Nema Degree Of Protection : not rated (open device)
  • Nema Size : 6
  • Maximum Width : 268 mm
  • Electrical Connection : screw clamp terminals
  • Warranty : 18 months
  • Local Signalling : without pilot light
  • Line Rated Current : 540 A
  • Auxiliary Contact Composition : without
  • Maximum Height : 713 mm
  • Product Or Component Type : motor starter
  • Thermal Overload Type : solid state Motor Logic class 10/20
  • Motor Starter Type : non reversing
  • Rated Power In Hp : 150 HP 200 V AC || 200 HP 230 V AC || 400 HP 460 V AC || 400 HP 575 V AC
  • Phase : 3 phase