NEMA Motor Starter, Type S, nonreversing, Size 3, 90A, 50 HP at 460 VAC, 5 kA SCCR, 3 phase, 3 pole, melting alloy, 24 VAC coil, open

NEMA Motor Starter, Type S, nonreversing, Size 3, 90A, 50 HP at 460 VAC, 5 kA SCCR, 3 phase, 3 pole, melting alloy, 24 VAC coil, open

SQD8536SEO1V01S 8536SEO1V01S 785901724186
1522.00 / EACH
  • Certifications: CSA, NEMA, UL Listed
  • Contact Configuration: Without
  • Depth: 165 mm
  • Height: 282 mm
  • Line Rated Current: 90 A
  • NEMA: 3
  • Number of Phases: 3
  • Warranty Length: 18 mth
  • Width: 139 mm
Type S NEMA motor starters are used for full voltage starting and stopping of AC squirrel cage motors. Type S motor starters have ratings up to 810 amperes. This 3 pole NEMA Size 3 non-reversing starter has a 90 ampere rating. This NEMA Size 3 motor starter has 3 phase ratings of 25 HP at 200 VAC, 30 HP at 230 VAC and 50 HP at 460 and 575 VAC. This non-reversing NEMA motor starter has a melting alloy type overload relay that uses Type CC thermal units to sense over current conditions. This NEMA starter has a 5 kA maximum SCCR (Short Circuit Current Rating) per UL508A when protected by an appropriate circuit breaker or fuse. Type S motor starters are available with replaceable coils in a wide variety of voltages. This starter has a 24 VAC 60 Hz operating coil wired for separate control. This NEMA starter is an open device without an enclosure. This starter is 11.09 inches tall, 5.47 inches wide and 6.50 inches deep. A wide variety of accessories are available for Type S starters. Type S non-reversing NEMA motor starters are UL listed and CSA certified.
  • Product Description
  • Specifications
Type S NEMA motor starters are used for full voltage starting and stopping of AC squirrel cage motors. Type S motor starters have ratings up to 810 amperes. This 3 pole NEMA Size 3 non-reversing starter has a 90 ampere rating. This NEMA Size 3 motor starter has 3 phase ratings of 25 HP at 200 VAC, 30 HP at 230 VAC and 50 HP at 460 and 575 VAC. This non-reversing NEMA motor starter has a melting alloy type overload relay that uses Type CC thermal units to sense over current conditions. This NEMA starter has a 5 kA maximum SCCR (Short Circuit Current Rating) per UL508A when protected by an appropriate circuit breaker or fuse. Type S motor starters are available with replaceable coils in a wide variety of voltages. This starter has a 24 VAC 60 Hz operating coil wired for separate control. This NEMA starter is an open device without an enclosure. This starter is 11.09 inches tall, 5.47 inches wide and 6.50 inches deep. A wide variety of accessories are available for Type S starters. Type S non-reversing NEMA motor starters are UL listed and CSA certified.
  • [Uc] Control Circuit Voltage : 24 V AC 60 Hz
  • Thermal Overload Type : melting alloy 3
  • Electrical Connection : screw clamp terminals
  • Maximum Height : 282 mm
  • Control Type : no control units
  • Local Signalling : without pilot light
  • Warranty : 18 months
  • Motor Starter Type : non reversing
  • Phase : 3 phase
  • Rated Power In Hp : 25 HP 200 V AC || 30 HP 230 V AC || 50 HP 460 V AC || 50 HP 575 V AC
  • Product Certifications : UL Listed || CSA || NEMA
  • Nema Degree Of Protection : not rated (open device)
  • Nema Size : 3
  • Product Or Component Type : motor starter
  • Maximum Depth : 165 mm
  • Auxiliary Contact Composition : without
  • Range Of Product : S
  • [Ue] Rated Operational Voltage : 600 V AC
  • Control Circuit : separate control circuit
  • Line Rated Current : 90 A
  • Maximum Width : 139 mm
  • Poles Description : 3P