NEMA Motor Starter, Type S, nonreversing, Size 2, 45A, 25 HP at 460 VAC, 5 kA SCCR, 3 phase, 3 pole, melting alloy, 120 VAC coil, NEMA 12

NEMA Motor Starter, Type S, nonreversing, Size 2, 45A, 25 HP at 460 VAC, 5 kA SCCR, 3 phase, 3 pole, melting alloy, 120 VAC coil, NEMA 12

SQD8536SDA1V02AS 8536SDA1V02AS 785901719632
1819.09 / EACH
  • Certifications: CSA, NEMA, UL Listed
  • Contact Configuration: Without
  • Depth: 236 mm
  • Height: 406 mm
  • Line Rated Current: 45 A
  • NEMA: 2
  • Number of Phases: 3
  • Warranty Length: 18 mth
  • Width: 207 mm
Type S NEMA motor starters are used for full voltage starting and stopping of AC squirrel cage motors. Type S motor starters have ratings up to 810 amperes. This 3 pole NEMA Size 2 non-reversing starter has a 45 ampere rating. This NEMA Size 2 motor starter has 3 phase ratings of 10 HP at 200 VAC, 15 HP at 230 VAC and 25 HP at 460 and 575 VAC. This non-reversing NEMA motor starter has a melting alloy type overload relay that uses Type B thermal units to sense over current conditions. This NEMA starter has a 5 kA maximum SCCR (Short Circuit Current Rating) per UL508A when protected by an appropriate circuit breaker or fuse. Type S motor starters are available with replaceable coils in a wide variety of voltages. This starter has a 110/120 VAC 50/60 Hz operating coil wired for separate control. A painted sheet steel NEMA 12/3R dusttight and driptight industrial use enclosure is used to protect this starter. Enclosure is 16.00 inches tall, 8.13 inches wide and 9.28 inches deep. A wide variety of accessories are available for Type S starters. This starter is supplied with START STOP momentary push buttons. Type S non-reversing NEMA motor starters are UL listed and CSA certified.
  • Product Description
  • Specifications
Type S NEMA motor starters are used for full voltage starting and stopping of AC squirrel cage motors. Type S motor starters have ratings up to 810 amperes. This 3 pole NEMA Size 2 non-reversing starter has a 45 ampere rating. This NEMA Size 2 motor starter has 3 phase ratings of 10 HP at 200 VAC, 15 HP at 230 VAC and 25 HP at 460 and 575 VAC. This non-reversing NEMA motor starter has a melting alloy type overload relay that uses Type B thermal units to sense over current conditions. This NEMA starter has a 5 kA maximum SCCR (Short Circuit Current Rating) per UL508A when protected by an appropriate circuit breaker or fuse. Type S motor starters are available with replaceable coils in a wide variety of voltages. This starter has a 110/120 VAC 50/60 Hz operating coil wired for separate control. A painted sheet steel NEMA 12/3R dusttight and driptight industrial use enclosure is used to protect this starter. Enclosure is 16.00 inches tall, 8.13 inches wide and 9.28 inches deep. A wide variety of accessories are available for Type S starters. This starter is supplied with START STOP momentary push buttons. Type S non-reversing NEMA motor starters are UL listed and CSA certified.
  • Thermal Overload Type : melting alloy 3
  • Maximum Height : 406 mm
  • Motor Starter Type : non reversing
  • Nema Degree Of Protection : NEMA 12 painted sheet steel
  • Rated Power In Hp : 10 HP 200 V AC || 15 HP 230 V AC || 25 HP 460 V AC || 25 HP 575 V AC
  • Electrical Connection : screw clamp terminals
  • Range Of Product : S
  • Product Or Component Type : motor starter
  • Product Certifications : UL Listed || CSA || NEMA
  • Local Signalling : without pilot light
  • Phase : 3 phase
  • [Uc] Control Circuit Voltage : 110 V AC 50 Hz || 120 V AC 60 Hz
  • Auxiliary Contact Composition : without
  • Control Circuit : separate control circuit
  • Control Type : 2 momentary push-buttons (START-STOP)
  • [Ue] Rated Operational Voltage : 600 V AC
  • Warranty : 18 months
  • Poles Description : 3P
  • Maximum Depth : 236 mm
  • Line Rated Current : 45 A
  • Nema Size : 2
  • Maximum Width : 207 mm