SQUARE D

NEMA Motor Starter, Type S, nonreversing, Size 00, 9A, 2 HP at 460 VAC, 5 kA SCCR, 3 phase, 3 pole, melting alloy, 120 VAC coil, NEMA 1

STARTER 600VAC 9AMP NEMA +OPTI

SQD8536SAG12V81FF4T 8536SAG12V81FF4T 785901768081
1134.55 / EACH
http://schema.org/OutOfStock
  • Certifications: CSA, NEMA, UL Listed
  • Contact Configuration: Without
  • Depth: 132 mm
  • Height: 403 mm
  • Line Rated Current: 9 A
  • Number of Phases: 3
  • Warranty Length: 18 mth
  • Width: 161 mm
Type S NEMA motor starters are used for full voltage starting and stopping of AC squirrel cage motors. Type S motor starters have ratings up to 810 amperes. This 3 pole NEMA Size 00 non-reversing starter has an 9 ampere rating. This NEMA Size 00 motor starter has 3 phase ratings of 1.5 HP at 220 and 230 VAC and 2 HP at 460 and 575 VAC. This non-reversing NEMA motor starter has a melting alloy type overload relay that uses Type B thermal units to sense over current conditions. This NEMA starter has a 5 kA maximum SCCR (Short Circuit Current Rating) per UL508A when protected by an appropriate circuit breaker or fuse. Type S motor starters are available with replaceable coils in a wide variety of voltages. This starter has a 110/120 VAC 50/60 Hz operating coil wired for common control. A painted sheet steel NEMA 1 general purpose enclosure is used to protect this starter. Enclosure is 15.88 inches tall, 6.34 inches wide and 5.19 inches deep. A wide variety of accessories are available for Type S starters. This starter is supplied with fused transformer. Transformer has a 480 VAC primary and a 120 VAC secondary. Type S NEMA starters are UL listed and CSA certified.
QTY
  • Product Description
  • Specifications
Type S NEMA motor starters are used for full voltage starting and stopping of AC squirrel cage motors. Type S motor starters have ratings up to 810 amperes. This 3 pole NEMA Size 00 non-reversing starter has an 9 ampere rating. This NEMA Size 00 motor starter has 3 phase ratings of 1.5 HP at 220 and 230 VAC and 2 HP at 460 and 575 VAC. This non-reversing NEMA motor starter has a melting alloy type overload relay that uses Type B thermal units to sense over current conditions. This NEMA starter has a 5 kA maximum SCCR (Short Circuit Current Rating) per UL508A when protected by an appropriate circuit breaker or fuse. Type S motor starters are available with replaceable coils in a wide variety of voltages. This starter has a 110/120 VAC 50/60 Hz operating coil wired for common control. A painted sheet steel NEMA 1 general purpose enclosure is used to protect this starter. Enclosure is 15.88 inches tall, 6.34 inches wide and 5.19 inches deep. A wide variety of accessories are available for Type S starters. This starter is supplied with fused transformer. Transformer has a 480 VAC primary and a 120 VAC secondary. Type S NEMA starters are UL listed and CSA certified.
  • Specifications
    • Motor Starter Type : non reversing
    • Range Of Product : S
    • Product Or Component Type : motor starter
  • Contractual warranty
    • Warranty : 18 months
  • Complementary
    • Local Signalling : without pilot light
    • Thermal Overload Type : melting alloy 3
    • Height : 403 mm
    • Auxiliary Contact Composition : without
    • Nema Size : 00
    • [Uc] Control Circuit Voltage : 120 V AC 60 Hz secondary circuit || 480 V AC 60 Hz primary circuit
    • Poles Description : 3P
    • Rated Power In Hp : 1.5 HP 200 V AC || 1.5 HP 230 V AC || 2 HP 460 V AC || 2 HP 575 V AC
    • Electrical Connection : screw clamp terminals
    • Provided Equipment : 2 fuses (primary), 1 fuse (secondary)
    • Line Rated Current : 9 A
    • Control Type : no control units
    • Control Circuit : control circuit transformer
    • Width : 161 mm
    • Depth : 132 mm
    • Phase : 3 phase
    • [Ue] Rated Operational Voltage : 600 V AC
  • Offer Sustainability
    • China Rohs Regulation : Product out of China RoHS scope. Substance declaration for your information.
    • Pvc Free : Yes
    • Eu Rohs Directive : Not compliant
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Environment
    • Product Certifications : UL Listed || CSA || NEMA
    • Nema Degree Of Protection : NEMA 1 painted sheet steel