Panelboard interior, NF, main lugs, 125A, Cu bus, 30 pole spaces, 3 phase, 4 wire, 480Y/277 VAC bolt on

PNLBD INT NF CW 125A MLO 30CKT

SQDNF8430L1C NF8430L1C 785901714767
2554.71 / EACH
http://schema.org/OutOfStock
  • Circuit Breaker Type: EDB/EDG/EDJ
  • Height: 27 in
  • Line Rated Current: 100 A
  • Material: Copper
  • Number of Phases: 3
  • Standard: CSA C22.2, UL 67
  • Warranty Length: 18 mth
  • Width: 10.44 in
NF Panelboard interiors can be used for applications such as commercial buildings, industrial buildings, stadiums, and offices. These interiors provide protection for commercial and industrial applications. NF Panelboards feature a wide selection of circuit breakers, accessories, and ready to install kits. NF Panelboards are field convertible to top or bottom feed. NF Panelboards are convertible from main lug to main breaker. NF Panelboards can provide 200% rated neutrals for nonlinear loads. Some factory installed options are split bus, lighting contactors, compression lugs, surge protection devices, and phenolic nameplates. The main lugs are rated at 100A 480Y/277 VAC 3 phase. Interior has an interrupt current rating of up to 65 kA. This interior is for a 4 wire system with 30 spaces and has a copper bus bar. Interior is for EDB, EDG, and EDJ branch circuit breakers. Line lug connections will accept 6 AWG to 300 kcmil copper or aluminum wire. The interior is 27 inches tall and 10.44 inches wide. This interior is UL listed and CSA certified.
QTY
  • Product Description
  • Specifications
NF Panelboard interiors can be used for applications such as commercial buildings, industrial buildings, stadiums, and offices. These interiors provide protection for commercial and industrial applications. NF Panelboards feature a wide selection of circuit breakers, accessories, and ready to install kits. NF Panelboards are field convertible to top or bottom feed. NF Panelboards are convertible from main lug to main breaker. NF Panelboards can provide 200% rated neutrals for nonlinear loads. Some factory installed options are split bus, lighting contactors, compression lugs, surge protection devices, and phenolic nameplates. The main lugs are rated at 100A 480Y/277 VAC 3 phase. Interior has an interrupt current rating of up to 65 kA. This interior is for a 4 wire system with 30 spaces and has a copper bus bar. Interior is for EDB, EDG, and EDJ branch circuit breakers. Line lug connections will accept 6 AWG to 300 kcmil copper or aluminum wire. The interior is 27 inches tall and 10.44 inches wide. This interior is UL listed and CSA certified.
  • Environment
    • Standards : UL 67 || CSA C22.2
  • Contractual warranty
    • Warranty : 18 months
  • Offer Sustainability
    • China Rohs Regulation : Product out of China RoHS scope. Substance declaration for your information.
    • Rohs Exemption Information : Yes
    • Mercury Free : Yes
    • Eu Rohs Directive : Compliant with Exemptions
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Nickel compounds, which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Complementary
    • Height : 27 in
    • Connections - Terminals : lug line AWG 6...300 kcmil aluminium/copper || lug neutral AWG 6...300 kcmil aluminium/copper
    • Enclosure Nominal Depth : 5.65 in NEMA 1
    • Tightening Torque : 4.52-5.65 N.m 13.30-67.43 mm² (AWG 6...AWG 2/0) || 11.3-11.3 N.m 13.30-67.43 mm² (AWG 6...AWG 2/0) || 31.07-31.07 N.m 13.30-177.3 mm² (AWG 6...350 kcmil) || 31.07-31.07 N.m 13.30-126.7 mm² (AWG 6...250 kcmil) || 31.07-31.07 N.m 107.2-152 mm² (AWG 4...300 kcmil)
    • Line Rated Current : 100 A
    • [Iu] Rated Interrupted Current : 65 kA
    • Wiring Configuration : 4-wire
    • Width : 10.44 in
    • Number Of Spaces : 30
    • Enclosure Nominal Height : 59 in
    • Phase : 3 phase
    • Enclosure Nominal Width : 8.625 in
    • [Ue] Rated Operational Voltage : 480Y/277 V AC
  • Specifications
    • Circuit Breaker Type : EDB/EDG/EDJ
    • Load Center Type : main lugs
    • Material : copper