NEMA Control Relay, Type X, machine tool, 10A resistive at 600 VAC, 2 normally open contacts, 115/125 VDC coil

NEMA Control Relay, Type X, machine tool, 10A resistive at 600 VAC, 2 normally open contacts, 115/125 VDC coil

SQD8501XDO20V62 8501XDO20V62 785901548713
277.57 / EA
  • Certifications: CSA LR60905 Class 3211 03, UL Listed File E78403 CCN NKCR
  • Depth: 5.17 in
  • Height: 3.56 in
  • Line Rated Current: 10 A, 5 A
  • Warranty Length: 18 mth
  • Width: 2.23 in
Square D® 8501 Type X relays combine a rugged, heavy-duty design with modular construction for greater design flexibility.
  • Specifications
  • Tightening Torque : control circuit 1.02-1.36 N.m screw terminals
  • Maximum Width : 2.23 in
  • Product Certifications : CSA LR60905 class 3211 03 || UL listed file E78403 CCN NKCR
  • Hold-In Power Consumption In W : 18-18 W
  • Product Or Component Type : relay
  • Control Circuit Voltage Limits : operational 0.8...1.1 Uc DC
  • [Icm] Rated Short-Circuit Making Capacity : 60 A 120 V AC inductive control circuit UL 508 || 0.8 A 250 V DC resistive control circuit UL 508 || 30 A 240 V AC inductive control circuit UL 508 || 15 A 480 V AC inductive control circuit UL 508 || 12 A 600 V AC inductive control circuit UL 508 || 10 A <= 600 V AC resistive control circuit UL 508 || 1.1 A 125 V DC inductive control circuit UL 508 || 0.55 A 250 V DC inductive control circuit UL 508 || 0.2 A 301...600 V DC inductive control circuit UL 508 || 4 A 125 V DC inductive control circuit UL 508
  • Mounting Support : panel
  • [Uc] Control Circuit Voltage : 115/125 V DC
  • Range Of Product : 8501X
  • Contacts Type And Composition : 2 NO 2 standard contact cartridges
  • Relay Type : control
  • Electrical Connection : screw clamp terminals
  • Ambient Air Temperature For Operation : -40-160 °F
  • Awg Gauge : AWG 18...AWG 12 copper
  • Operating Time : 37 ms - pick-up || 21 ms - drop-out
  • Inrush Power In W : 18 W
  • Rated Breaking Capacity : 6 A 120 V AC inductive control circuit UL 508 || 0.8 A 250 V DC resistive control circuit UL 508 || 3 A 240 V AC inductive control circuit UL 508 || 1.5 A 480 V AC inductive control circuit UL 508 || 1.2 A 600 V AC inductive control circuit UL 508 || 10 A <= 600 V AC resistive control circuit UL 508 || 1.1 A 125 V DC inductive control circuit UL 508 || 0.55 A 250 V DC inductive control circuit UL 508 || 0.2 A 301...600 V DC inductive control circuit UL 508 || 4 A 125 V DC resistive control circuit UL 508
  • Line Rated Current : 10 A AC || 5 A DC
  • Warranty : 18 months
  • Maximum Depth : 5.17 in
  • Maximum Height : 3.56 in