NEMA Contactor, Type S, nonreversing, Size 5, 270A, 1 phase, up to 100 kA, 2 pole, 380 VAC coil, open [TAA]

NEMA Contactor, Type S, nonrev

SQD8502SGO1V05 502SGO1V05 SQD8502SGO1V05
10911.29 / EA
http://schema.org/OutOfStock
  • Country of Origin: Mexico
  • Depth: 222.25 mm
  • Warranty Length: 18 mth
Type S non-reversing magnetic contactors are used to switch heating loads, capacitors, transformers, and electric motors where overload protection is provided separately. Type S contactors have ratings up to 810 amperes. This 2 pole NEMA Size 5 non-reversing contactor has a 270 ampere rating. Single phase NEMA Size 5 contactors have no horsepower ratings. This NEMA contactor has a 100 kA maximum SCCR rating per UL508A when protected by an appropriate circuit breaker or fuse. These contactors are available with replaceable coils in a wide variety of voltages. This contactor has a 380 VAC 50 Hz coil that is wired for common control. This NEMA contactor is an open device without an enclosure. This contactor is 12.31 inches tall, 8.67 inches wide and 8.75 inches deep. A wide variety of accessories are available for Type S contactors. Type S NEMA contactors are UL listed and CSA certified.
QTY
  • Product Description
  • Specifications
Type S non-reversing magnetic contactors are used to switch heating loads, capacitors, transformers, and electric motors where overload protection is provided separately. Type S contactors have ratings up to 810 amperes. This 2 pole NEMA Size 5 non-reversing contactor has a 270 ampere rating. Single phase NEMA Size 5 contactors have no horsepower ratings. This NEMA contactor has a 100 kA maximum SCCR rating per UL508A when protected by an appropriate circuit breaker or fuse. These contactors are available with replaceable coils in a wide variety of voltages. This contactor has a 380 VAC 50 Hz coil that is wired for common control. This NEMA contactor is an open device without an enclosure. This contactor is 12.31 inches tall, 8.67 inches wide and 8.75 inches deep. A wide variety of accessories are available for Type S contactors. Type S NEMA contactors are UL listed and CSA certified.
  • Complementary Attributes
    • Control Circuit : common control circuit
    • Line Rated Current : 270 A
    • Rated Power In Hp : not rated
  • Important Information Attributes
    • Certificate Agency : UL listed file E78351 CCN NLDX, CSA
    • Carbon Footprint Of The Distribution Phase [A4] : 3.9325431611337964, 4 kg CO2 eq.
    • Carbon Footprint Of The End-of-life Phase [C1 To C4] : 24 kg CO2 eq., 23.847249181612117
    • Carbon Footprint Of The Installation Phase [A5] : 2.720777733354162, 3 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase [A1 To A3] : 81 kg CO2 eq., 80.59138282290486
    • Carbon Footprint Of The Use Phase [B2, B3, B4, B6] : 17 797 kg CO2 eq., 17796.997647865446
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-11-18
    • Return Indicator : N
    • Stocking Flag : Y
    • Stock Policy : 2
    • Device Type : LV equipment - LV contactor
    • Serviceability : No
    • Traceability : No
    • Field Service Division : PPIBS
    • Average Life Duration : 20 year(s)
    • Scope Perimeter : Outside of Europe
    • Eoli Availability Display : No need of specific recycling operations
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : Yes
    • Rohs Eur Status : Compliant
    • Rohs Eur Full Compliance Status : Compliant
    • China Rohs In Scope : No
    • China Rohs Label : 1
    • With Recycled Cardboard : No
    • Without Single Use Plastic : No
    • Product Contributes To Saved And Avoided Emissions : No
    • Product Kit Identifier : N
    • Contactor Application : non-reversing
    • Control Circuit : common control circuit
    • Control Type : no control units
    • Electrical Connection : screw clamp terminals
    • Local Signalling : no indicator
    • Number Of Poles : 2P
    • Phase : 1 phase
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Or Component Type : contactor
    • Provided Equipment : fuse not supplied
    • Range Of Product : 8502S
    • Returnability : No
    • Software Version : v6.2.4
    • Sustainable Packaging : No
    • Total Lifecycle Carbon Footprint : 17 908 kg CO2 eq.
    • Pep Code : ENVPEP2506044EN
    • Database Version : 2024-01
    • Pep Verification Date : 2025-09-01
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed3-2023 12 08
    • Type Of Verification For The Pep : Independent internal review
    • Data Source : extrapolated product
    • Functional-unit Description : Establish and cut off the supply of a downstream installation from an electrical and/or mechanical control characterised by the composition of the poles or type of contacts X, a rated voltage of Ue, a rated current Ie, a control circuit voltage Uc, with Np poles, and if applicable the specific specifications, in the Household/Commercial or Industrial application areas, according to the appropriate use scenario, and during the reference service life of the product of 20 years
    • Functional-unit Quantity : 1
    • Functional-unit Unit : unit
    • Reference Lifetime, In Y : 20
    • Energy Model - Manufacturing [A1-a3] : Electricity Mix; Low voltage; 2020; United States, US
    • Energy Model - Installation [A5] : No energy used
    • Energy Model - Use [B6] : Electricity Mix; Low voltage; 2020; United States, US
    • Energy Model - End Of Life [C1-c4] : Global, European and French datasets are used.
    • Recyclability Potential, In % : 54
    • Height Nominal : 312.67 mm
    • Width Nominal : 220.22 mm
    • [Uc] Control Circuit Voltage : 380 V AC 50 Hz
    • [Ue] Rated Operational Voltage : 600 V AC
    • Nbr. Of Units In Pkg. : 1
    • Package Weight(Lbs) : 13.608 kg
    • Take-back : No
    • Warranty (In Months) : 18
    • Customs Code : 8536490065
  • Environment Attributes Main
    • China Rohs Regulation : Product out of China RoHS scope , Pro-active China RoHS declaration (out of China RoHS legal scope)
    • Product Compatibility : circuit-breaker 400 A maximum, SCCR: 100 kA at 480 V AC, fuse J 400 A maximum, SCCR: 100 kA at 600 V AC, fuse T 400 A maximum, SCCR: 100 kA at 600 V AC, fuse RK1 400 A maximum, SCCR: 100 kA at 600 V AC, fuse RK5 400 A maximum, SCCR: 100 kA at 600 V AC
    • Take Back : No
    • Recycled Metal Content At Cr Level : 0 %
    • Toxic Heavy Metal Free : Yes
    • Mercury Free : Yes
    • Carbon Footprint : 17908.08960076445
    • Environmental Disclosure : ENVPEP2506044EN
    • Eu Rohs Directive : Compliant
    • Nema Degree Of Protection : not rated (open device)
    • Nema Size : 5
    • Packaging Made With Recycled Cardboard : No
    • Packaging Without Single Use Plastic : No
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP2506044EN
    • Pep Verification Date : 2025-09-01
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed3-2023 12 08
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Phase : 1 phase
    • Product Or Component Type : contactor
    • Provided Equipment : fuse not supplied
    • Range Of Product : 8502S
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Specifications
    • Country of Origin : Mexico
    • Compliance : TAA Compliant
    • Depth : 222.25 mm