NEMA Contactor, Type S, nonreversing, Size 4, 135A, 100 HP at 575 VAC, 3 phase, up to 100 kA, 3 pole, 120V coil, NEMA 12

NEMA Contactor, Type S, nonreversing, Size 4, 135A, 100 HP at 575 VAC, 3 phase, up to 100 kA, 3 pole, 120V coil, NEMA 12

SQD8502SFA2V02S 8502SFA2V02S 785901177098
4875.40 / EACH
  • Certifications: CSA, UL Listed File E78351 CCN NLDX
  • Contact Configuration: Without
  • Depth: 243 mm
  • Height: 800 mm
  • Line Rated Current: 135 A
  • NEMA: 4
  • Number of Phases: 3
  • Warranty Length: 18 mth
  • Width: 461 mm
Type S non-reversing magnetic contactors are used to switch heating loads, capacitors, transformers, and electric motors where overload protection is provided separately. Type S contactors have ratings up to 810 amperes. This 3 pole NEMA Size 4 non-reversing contactor has a 135 ampere rating. Three phase NEMA Size 4 contactors have 40 HP at 200, 50 HP at 230 VAC and 100 HP at 460 and 575 VAC ratings. This NEMA contactor has a 100 kA maximum SCCR rating per UL508A when protected by an appropriate circuit breaker or fuse. These contactors are available with replaceable coils in a wide variety of voltages. This contactor has a 110/120 VAC 50/60 Hz coil that is wired for separate control. This NEMA contactor is in a NEMA 3R rainproof NEMA 12 dusttight enclosure. This enclosure is 31.50 inches tall, 18.16 inches wide and 9.56 inches deep. A wide variety of accessories are available for Type S contactors. Type S NEMA contactors are UL listed and CSA certified.
  • Product Description
  • Specifications
Type S non-reversing magnetic contactors are used to switch heating loads, capacitors, transformers, and electric motors where overload protection is provided separately. Type S contactors have ratings up to 810 amperes. This 3 pole NEMA Size 4 non-reversing contactor has a 135 ampere rating. Three phase NEMA Size 4 contactors have 40 HP at 200, 50 HP at 230 VAC and 100 HP at 460 and 575 VAC ratings. This NEMA contactor has a 100 kA maximum SCCR rating per UL508A when protected by an appropriate circuit breaker or fuse. These contactors are available with replaceable coils in a wide variety of voltages. This contactor has a 110/120 VAC 50/60 Hz coil that is wired for separate control. This NEMA contactor is in a NEMA 3R rainproof NEMA 12 dusttight enclosure. This enclosure is 31.50 inches tall, 18.16 inches wide and 9.56 inches deep. A wide variety of accessories are available for Type S contactors. Type S NEMA contactors are UL listed and CSA certified.
  • Phase : 3 phase
  • Product Or Component Type : contactor
  • Maximum Depth : 243 mm
  • [Ue] Rated Operational Voltage : 600 V AC
  • Provided Equipment : fuse not supplied
  • Maximum Height : 800 mm
  • Local Signalling : no indicator
  • Range Of Product : 8502S
  • Contactor Application : non-reversing
  • Maximum Width : 461 mm
  • Poles Description : 3P
  • Line Rated Current : 135 A
  • Control Type : no control units
  • Auxiliary Contact Composition : without
  • Nema Degree Of Protection : NEMA 12 painted sheet steel
  • Product Certifications : UL listed file E78351 CCN NLDX || CSA
  • Warranty : 18 months
  • [Uc] Control Circuit Voltage : 120 V AC 60 Hz || 110 V AC 50 Hz
  • Product Compatibility : circuit-breaker 225 A maximum, SCCR: 100 kA at 480 V AC || fuse J 200 A maximum, SCCR: 100 kA at 600 V AC || fuse T 200 A maximum, SCCR: 100 kA at 600 V AC || fuse RK1 200 A maximum, SCCR: 100 kA at 600 V AC || fuse RK5 200 A maximum, SCCR: 100 kA at 600 V AC
  • Rated Power In Hp : 40 HP 200 V AC || 50 HP 230 V AC || 100 HP 460 V AC || 100 HP 575 V AC
  • Electrical Connection : screw clamp terminals
  • Control Circuit : separate control circuit
  • Nema Size : 4