SQUARE D

NEMA Contactor, Type S, nonreversing, Size 1, 27A, 10HP at 575VAC, 3 phase, up to 100kA, 3 pole, 240VAC coil, open [TAA]

NEMA Contactor, Type S, nonreversing, Size 1, 27A, 10HP at 575VAC, 3 phase, up to 100kA, 3 pole, 240VAC coil, open [TAA]

SQD8502SCO2V03 8502SCO2V03 785901764038
545.84 / EACH
http://schema.org/OutOfStock
  • Warranty Length: 18 mth
Type S non-reversing magnetic contactors are used to switch heating loads, capacitors, transformers, and electric motors where overload protection is provided separately. Type S contactors have ratings up to 810 amperes. This 3 pole NEMA Size 1 non-reversing contactor has a 27 ampere rating. Three phase NEMA Size 1 contactors have 7.5 HP at 200 and 230 VAC and 10 HP at 460 and 575 VAC ratings. This NEMA contactor has a 100 kA maximum SCCR rating per UL508A when protected by an appropriate circuit breaker or fuse. These contactors are available with replaceable coils in a wide variety of voltages. This contactor has a 220/240 VAC 50/60 Hz coil that is wired for common control. This NEMA contactor is an open device without an enclosure. This contactor is 4.34 inches tall, 3.22 inches wide and 4.22 inches deep. A wide variety of accessories are available for Type S contactors. Type S NEMA contactors are UL listed and CSA certified.
QTY
  • Product Description
  • Features
  • Specifications
Type S non-reversing magnetic contactors are used to switch heating loads, capacitors, transformers, and electric motors where overload protection is provided separately. Type S contactors have ratings up to 810 amperes. This 3 pole NEMA Size 1 non-reversing contactor has a 27 ampere rating. Three phase NEMA Size 1 contactors have 7.5 HP at 200 and 230 VAC and 10 HP at 460 and 575 VAC ratings. This NEMA contactor has a 100 kA maximum SCCR rating per UL508A when protected by an appropriate circuit breaker or fuse. These contactors are available with replaceable coils in a wide variety of voltages. This contactor has a 220/240 VAC 50/60 Hz coil that is wired for common control. This NEMA contactor is an open device without an enclosure. This contactor is 4.34 inches tall, 3.22 inches wide and 4.22 inches deep. A wide variety of accessories are available for Type S contactors. Type S NEMA contactors are UL listed and CSA certified.
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Complementary Attributes
    • Rated Power In HP : 7.5 HP 200 V AC, 7.5 HP 200 V AC, 7.5 HP 200 V AC, 7.5 HP 230 V AC, 7.5 HP 230 V AC, 7.5 HP 230 V AC, 10 HP 460 V AC, 10 HP 460 V AC, 10 HP 460 V AC, 10 HP 575 V AC, 10 HP 575 V AC, 10 HP 575 V AC
    • UC Control Circuit Voltage : 240 V AC 60 Hz, 240 V AC 60 Hz, 240 V AC 60 Hz, 220 V AC 50 Hz, 220 V AC 50 Hz, 220 V AC 50 Hz
    • UE Rated Operational Voltage : 600 V AC, 600 V AC
  • Important Information Attributes
    • Persona Type Ids : EU, LC, OM, OM8, PB
    • Persona Type Names : End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Carbon Footprint Of The Distribution Phase A4 : 0.4274126495676723, 0.4 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 3 kg CO2 eq., 2.591863722781034
    • Carbon Footprint Of The Installation Phase A5 : 0.29571063107222256, 0.3 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 9 kg CO2 eq., 8.759160434676387
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 422 kg CO2 eq., 421.5869519305879
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-11-18
    • HTML Description : NEMA Contactor, Type S, nonreversing, Size 1, 27A, 3 pole, 220/240 VAC 50/60 Hz coil, open style
    • Manufacturer : Schneider Electric
    • Device Type : LV equipment - LV contactor
    • Serviceability : No
    • Traceability : No
    • Field Service Division : PPIBS
    • Average Life Duration : 20 year(s)
    • Legacy WEEE Scope : In
    • Scope Perimeter : At least in Europe
    • EOLI Availability Display : No need of specific recycling operations
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • ROHS EUR In Scope : Yes
    • ROHS EUR Status : Will not be Compliant
    • ROHS EUR Full Compliance Status : Not compliant
    • ROHS EUR Full Compliance Status Id : NOT_COMPLIANT
    • China ROHS In Scope : Yes
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Return Indicator : Y
    • WD Status : A - SELECTED - PCE ONLY (Migration)
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Contactor Application : non-reversing
    • Energy Efficiency Optimized : False
    • Local Signalling : no indicator
    • Package Weight Lbs : 1.479 kg
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Or Component Type : contactor
    • Range Of Product : 8502S
    • Returnability : Yes
    • Sustainable Packaging : Yes
    • Total Lifecycle Carbon Footprint : 434 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Relationship Type : Compatible relationship
    • Pep Code : ENVPEP2506044EN
    • Pep Verification Date : 2025-09-01
    • PCR Version : PEP-PCR-ed4-2021 09 06
    • PSR Version : PSR-0005-ed3-2023 12 08
    • Type Of Verification For The Pep : Independent internal review
    • Functional Unit Description : Establish and cut off the supply of a downstream installation from an electrical and/or mechanical control characterised by the composition of the poles or type of contacts X, a rated voltage of Ue, a rated current Ie, a control circuit voltage Uc, with Np poles, and if applicable the specific specifications, in the Household/Commercial or Industrial application areas, according to the appropriate use scenario, and during the reference service life of the product of 20 years
    • Functional Unit Unit : unit
    • Product Kit Identifier : N
  • Environment Attributes Main
    • Product Compatibility : circuit-breaker 70 A maximum, SCCR: 100 kA at 480 V AC, circuit-breaker 70 A maximum, SCCR: 100 kA at 480 V AC, circuit-breaker 70 A maximum, SCCR: 100 kA at 480 V AC, circuit-breaker 70 A maximum, SCCR: 100 kA at 480 V AC, circuit-breaker 70 A maximum, SCCR: 100 kA at 480 V AC, circuit-breaker 70 A maximum, SCCR: 100 kA at 480 V AC, fuse J 60 A maximum, SCCR: 100 kA at 600 V AC, fuse J 60 A maximum, SCCR: 100 kA at 600 V AC, fuse J 60 A maximum, SCCR: 100 kA at 600 V AC, fuse J 60 A maximum, SCCR: 100 kA at 600 V AC, fuse J 60 A maximum, SCCR: 100 kA at 600 V AC, fuse J 60 A maximum, SCCR: 100 kA at 600 V AC, fuse J 60 A maximum, SCCR: 100 kA at 600 V AC, fuse T 60 A maximum, SCCR: 100 kA at 600 V AC, fuse T 60 A maximum, SCCR: 100 kA at 600 V AC, fuse T 60 A maximum, SCCR: 100 kA at 600 V AC, fuse T 60 A maximum, SCCR: 100 kA at 600 V AC, fuse T 60 A maximum, SCCR: 100 kA at 600 V AC, fuse T 60 A maximum, SCCR: 100 kA at 600 V AC, fuse T 60 A maximum, SCCR: 100 kA at 600 V AC, fuse RK1 60 A maximum, SCCR: 100 kA at 600 V AC, fuse RK1 60 A maximum, SCCR: 100 kA at 600 V AC, fuse RK1 60 A maximum, SCCR: 100 kA at 600 V AC, fuse RK1 60 A maximum, SCCR: 100 kA at 600 V AC, fuse RK1 60 A maximum, SCCR: 100 kA at 600 V AC, fuse RK1 60 A maximum, SCCR: 100 kA at 600 V AC, fuse RK1 60 A maximum, SCCR: 100 kA at 600 V AC, fuse RK5 60 A maximum, SCCR: 100 kA at 600 V AC, fuse RK5 60 A maximum, SCCR: 100 kA at 600 V AC, fuse RK5 60 A maximum, SCCR: 100 kA at 600 V AC, fuse RK5 60 A maximum, SCCR: 100 kA at 600 V AC, fuse RK5 60 A maximum, SCCR: 100 kA at 600 V AC, fuse RK5 60 A maximum, SCCR: 100 kA at 600 V AC, fuse RK5 60 A maximum, SCCR: 100 kA at 600 V AC
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold, Reference contains Substances of Very High Concern above the threshold
    • Take Back : No
    • Recycled Metal Content At Cr Level : 0 %
    • China ROHS Regulation : X
    • Carbon Footprint : 433.6610993686852
    • Environmental Disclosure : ENVPEP2506044EN
    • EU ROHS Directive : Not compliant
    • Nema Degree Of Protection : not rated (open device)
    • Nema Size : 1
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Pep Code : ENVPEP2506044EN
    • Pep Verification Date : 2025-09-01
    • PCR Version : PEP-PCR-ed4-2021 09 06
    • PSR Version : PSR-0005-ed3-2023 12 08
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Product Or Component Type : contactor
    • Range Of Product : 8502S
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months