SQUARE D

NEMA Contactor, Type S, nonreversing, Size 1, 27A, 10HP at 575VAC, 3 phase, up to 100kA, 3 pole, 240VAC coil, open [TAA]

CONTACTOR 600VAC 27AMP NEMA +O

SQD8502SCO2V03 8502SCO2V03 785901764038
545.84 / EACH
http://schema.org/OutOfStock
  • Country of Origin: Mexico
  • Warranty Length: 18 mth
Type S non-reversing magnetic contactors are used to switch heating loads, capacitors, transformers, and electric motors where overload protection is provided separately. Type S contactors have ratings up to 810 amperes. This 3 pole NEMA Size 1 non-reversing contactor has a 27 ampere rating. Three phase NEMA Size 1 contactors have 7.5 HP at 200 and 230 VAC and 10 HP at 460 and 575 VAC ratings. This NEMA contactor has a 100 kA maximum SCCR rating per UL508A when protected by an appropriate circuit breaker or fuse. These contactors are available with replaceable coils in a wide variety of voltages. This contactor has a 220/240 VAC 50/60 Hz coil that is wired for common control. This NEMA contactor is an open device without an enclosure. This contactor is 4.34 inches tall, 3.22 inches wide and 4.22 inches deep. A wide variety of accessories are available for Type S contactors. Type S NEMA contactors are UL listed and CSA certified.
QTY
  • Product Description
  • Features
  • Specifications
Type S non-reversing magnetic contactors are used to switch heating loads, capacitors, transformers, and electric motors where overload protection is provided separately. Type S contactors have ratings up to 810 amperes. This 3 pole NEMA Size 1 non-reversing contactor has a 27 ampere rating. Three phase NEMA Size 1 contactors have 7.5 HP at 200 and 230 VAC and 10 HP at 460 and 575 VAC ratings. This NEMA contactor has a 100 kA maximum SCCR rating per UL508A when protected by an appropriate circuit breaker or fuse. These contactors are available with replaceable coils in a wide variety of voltages. This contactor has a 220/240 VAC 50/60 Hz coil that is wired for common control. This NEMA contactor is an open device without an enclosure. This contactor is 4.34 inches tall, 3.22 inches wide and 4.22 inches deep. A wide variety of accessories are available for Type S contactors. Type S NEMA contactors are UL listed and CSA certified.
  • Rated Power In HP
    • 7.5 HP 200 V AC
    • 7.5 HP 230 V AC
    • 10 HP 460 V AC
    • 10 HP 575 V AC
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Carbon Footprint Of The Installation Phase A5
    • 0.29571063107222256
    • 0.3 kg CO2 eq.
  • Carbon Footprint Of The End Of Life Phase C1 To C4
    • 3 kg CO2 eq.
    • 2.591863722781034
  • UC Control Circuit Voltage
    • 240 V AC 60 Hz
    • 220 V AC 50 Hz
  • Carbon Footprint Of The Manufacturing Phase A1 To A3
    • 9 kg CO2 eq.
    • 8.759160434676387
  • Accessories
    • 9999SX6
    • 9999SX7
    • 9999SX8
    • 9999ST1
  • Market Segmentation
    • Commercial
    • Industrial
  • Persona Type Names
    • End User
    • Contractor
    • Original Equipment Manufacturer
    • OEM - Control Panelbuilder
    • Panel Builder
  • Carbon Footprint Of The Use Phase B2 B3 B4 B6
    • 422 kg CO2 eq.
    • 421.5869519305879
  • Persona Type Ids
    • EU
    • LC
    • OM
    • OM8
    • PB
  • Carbon Footprint Of The Distribution Phase A4
    • 0.4274126495676723
    • 0.4 kg CO2 eq.
  • Market Segmentation Id
    • COMMERCIAL
    • INDUSTRIAL
  • Product Compatibility
    • circuit-breaker 70 A maximum, SCCR: 100 kA at 480 V AC
    • fuse J 60 A maximum, SCCR: 100 kA at 600 V AC
    • fuse T 60 A maximum, SCCR: 100 kA at 600 V AC
    • fuse RK1 60 A maximum, SCCR: 100 kA at 600 V AC
    • fuse RK5 60 A maximum, SCCR: 100 kA at 600 V AC
  • UE Rated Operational Voltage
    • 600 V AC
  • Important Information Attributes
    • B2B Bullet Point 1 : This 3 pole NEMA Size 1 non-reversing contactor has a 27 ampere rating and 240 VAC coil
    • B2B Bullet Point 2 : Switch heating loads, capacitors, transformers, and electric motors where overload protection is separately provided
    • B2B Bullet Point 3 : Robust design and reliable build for long mechanical life and electrical endurance
    • B2B Bullet Point 4 : Serviceable by replacing contacts and coils
    • B2B Bullet Point 5 : This product is TAA compliant.
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-11-18
    • HTML Description : NEMA Contactor, Type S, nonreversing, Size 1, 27A, 3 pole, 220/240 VAC 50/60 Hz coil, open style
    • Manufacturer : Schneider Electric
    • Device Type : LV equipment - LV contactor
    • Serviceability : No
    • Traceability : No
    • Field Service Division : PPIBS
    • Average Life Duration : 20 year(s)
    • Manufacturing Carbon Footprint : 8.759160434676387
    • Distribution Carbon Footprint : 0.4274126495676723
    • Installation Carbon Footprint : 0.29571063107222256
    • Use Carbon Footprint : 421.5869519305879
    • End Of Life Carbon Footprint : 2.591863722781034
    • Legacy WEEE Scope : In
    • WEEE Product Category : 5
    • Scope Perimeter : At least in Europe
    • EOLI Availability Display : No need of specific recycling operations
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • ROHS EUR In Scope : Yes
    • ROHS EUR Status : Will not be Compliant
    • ROHS EUR Full Compliance Status : Not compliant
    • ROHS EUR Full Compliance Status Id : NOT_COMPLIANT
    • China ROHS In Scope : Yes
    • China ROHS Label : 7
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Return Indicator : Y
    • WD Status : A - SELECTED - PCE ONLY (Migration)
    • Tier Id : 1
    • Tier : 1
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Contactor Application : non-reversing
    • Energy Efficiency Optimized : False
    • Local Signalling : no indicator
    • Package Weight Lbs : 1.479 kg
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Or Component Type : contactor
    • Range Of Product : 8502S
    • Returnability : Yes
    • Sustainable Packaging : Yes
    • Total Lifecycle Carbon Footprint : 434 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Carbon Footprint Kg Co2 Eq Total Life Cycle : 433.6610993686852
    • Relationship Type : Compatible relationship
    • Pep Code : ENVPEP2506044EN
    • Pep Verification Date : 2025-09-01
    • PCR Version : PEP-PCR-ed4-2021 09 06
    • PSR Version : PSR-0005-ed3-2023 12 08
    • Type Of Verification For The Pep : Independent internal review
    • Product Weight In G : 1479
    • Functional Unit Description : Establish and cut off the supply of a downstream installation from an electrical and/or mechanical control characterised by the composition of the poles or type of contacts X, a rated voltage of Ue, a rated current Ie, a control circuit voltage Uc, with Np poles, and if applicable the specific specifications, in the Household/Commercial or Industrial application areas, according to the appropriate use scenario, and during the reference service life of the product of 20 years
    • Functional Unit Quantity : 1
    • Functional Unit Unit : unit
    • Reference Lifetime In Y : 20
    • Energy Consumption On Product Lifetime In Kwh : 983.5570867421158
    • Recyclability Potential In : 54
    • Nbr Of Units In Pkg : 1
    • Warranty In Months : 18
    • Energy Model Manufacturing A1 A3 : Electricity Mix; Low voltage; 2020; United States, US
    • Energy Model Installation A5 : No energy used
    • Energy Model Use B6 : Electricity Mix; Low voltage; 2020; United States, US
    • Energy Model End Of Life C1 C4 : Global, European and French datasets are used.
    • Acidification Ap Mole Of H Equiv Total Life Cycle : 1.9853418062041959
    • Acidification Ap Mole Of H Equiv Manufacturing A1 A3 : 0.09850333597157085
    • Acidification Ap Mole Of H Equiv Distribution A4 : 0.0019287742648502791
    • Acidification Ap Mole Of H Equiv Installation A5 : 0.00031297097314960754
    • Acidification Ap Mole Of H Equiv Maintenance B2 : 0
    • Acidification Ap Mole Of H Equiv Repair B3 : 0
    • Acidification Ap Mole Of H Equiv Replacement B4 : 0
    • Acidification Ap Mole Of H Equiv Operational Energy Use B6 : 1.8775333991966667
    • Acidification Ap Mole Of H Equiv End Of Life C1 C4 : 0.007063325797958391
    • Acidification Ap Mole Of H Equiv Benefits Loads Beyond System Boundaries D : -0.036152070052141286
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C Total Life Cycle : 0
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C Manufacturing A1 A3 : 0
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C Distribution A4 : 0
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C Installation A5 : 0
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C Maintenance B2 : 0
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C Repair B3 : 0
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C Replacement B4 : 0
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C Operational Energy Use B6 : 0
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C End Of Life C1 C4 : 0
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C Benefits Loads Beyond System Boundaries D : 0
    • Biogenic Carbon Content Of The Product Kg Of C Total Life Cycle : 0
    • Biogenic Carbon Content Of The Product Kg Of C Manufacturing A1 A3 : 0
    • Biogenic Carbon Content Of The Product Kg Of C Distribution A4 : 0
    • Biogenic Carbon Content Of The Product Kg Of C Installation A5 : 0
    • Biogenic Carbon Content Of The Product Kg Of C Maintenance B2 : 0
    • Biogenic Carbon Content Of The Product Kg Of C Repair B3 : 0
    • Biogenic Carbon Content Of The Product Kg Of C Replacement B4 : 0
    • Biogenic Carbon Content Of The Product Kg Of C Operational Energy Use B6 : 0
    • Biogenic Carbon Content Of The Product Kg Of C End Of Life C1 C4 : 0
    • Biogenic Carbon Content Of The Product Kg Of C Benefits Loads Beyond System Boundaries D : 0
    • Climate Change Biogenics Kg Co2 Eq Total Life Cycle : 2.350194214034016
    • Climate Change Biogenics Kg Co2 Eq Manufacturing A1 A3 : -0.0014046503556863954
    • Climate Change Biogenics Kg Co2 Eq Distribution A4 : 0
    • Climate Change Biogenics Kg Co2 Eq Installation A5 : 0.2380658246281084
    • Climate Change Biogenics Kg Co2 Eq Maintenance B2 : 0
    • Climate Change Biogenics Kg Co2 Eq Repair B3 : 0
    • Climate Change Biogenics Kg Co2 Eq Replacement B4 : 0
    • Climate Change Biogenics Kg Co2 Eq Operational Energy Use B6 : 2.109483549246886
    • Climate Change Biogenics Kg Co2 Eq End Of Life C1 C4 : 0.004049490514707638
    • Climate Change Biogenics Kg Co2 Eq Benefits Loads Beyond System Boundaries D : -0.032367625264527626
    • Climate Change Fossil Fuels Kg Co2 Eq Total Life Cycle : 431.3108228661936
    • Climate Change Fossil Fuels Kg Co2 Eq Manufacturing A1 A3 : 8.760483170226243
    • Climate Change Fossil Fuels Kg Co2 Eq Distribution A4 : 0.4274126495676723
    • Climate Change Fossil Fuels Kg Co2 Eq Installation A5 : 0.057644805930274344
    • Climate Change Fossil Fuels Kg Co2 Eq Maintenance B2 : 0
    • Climate Change Fossil Fuels Kg Co2 Eq Repair B3 : 0
    • Climate Change Fossil Fuels Kg Co2 Eq Replacement B4 : 0
    • Climate Change Fossil Fuels Kg Co2 Eq Operational Energy Use B6 : 419.477468381341
    • Climate Change Fossil Fuels Kg Co2 Eq End Of Life C1 C4 : 2.5878138591283886
    • Climate Change Fossil Fuels Kg Co2 Eq Benefits Loads Beyond System Boundaries D : -2.672206724306049
    • Climate Change Total Kg Co2 Eq Total Life Cycle : 433.6610993686852
    • Climate Change Total Kg Co2 Eq Manufacturing A1 A3 : 8.759160434676387
    • Climate Change Total Kg Co2 Eq Distribution A4 : 0.4274126495676723
    • Climate Change Total Kg Co2 Eq Installation A5 : 0.29571063107222256
    • Climate Change Total Kg Co2 Eq Maintenance B2 : 0
    • Climate Change Total Kg Co2 Eq Repair B3 : 0
    • Climate Change Total Kg Co2 Eq Replacement B4 : 0
    • Climate Change Total Kg Co2 Eq Operational Energy Use B6 : 421.5869519305879
    • Climate Change Total Kg Co2 Eq End Of Life C1 C4 : 2.591863722781034
    • Climate Change Total Kg Co2 Eq Benefits Loads Beyond System Boundaries D : -2.7045743495705765
    • Components For Re Use Kg Total Life Cycle : 0
    • Components For Re Use Kg Manufacturing A1 A3 : 0
    • Components For Re Use Kg Distribution A4 : 0
    • Components For Re Use Kg Installation A5 : 0
    • Components For Re Use Kg Maintenance B2 : 0
    • Components For Re Use Kg Repair B3 : 0
    • Components For Re Use Kg Replacement B4 : 0
    • Components For Re Use Kg Operational Energy Use B6 : 0
    • Components For Re Use Kg End Of Life C1 C4 : 0
    • Components For Re Use Kg Benefits Loads Beyond System Boundaries D : 0
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Total Life Cycle : 0.015377805374631372
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Manufacturing A1 A3 : 0.015289060899219262
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Distribution A4 : 0.00000000003689299192
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Installation A5 : 0.00000000742652838124
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Maintenance B2 : 0
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Repair B3 : 0
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Replacement B4 : 0
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Operational Energy Use B6 : 0.00008928084290659446
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb End Of Life C1 C4 : -0.00000054383091585718
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Benefits Loads Beyond System Boundaries D : -0.0008871576075527234
    • Depletion Of Abiotic Resources Fossil Fuels Mj Total Life Cycle : 9410.377681028891
    • Depletion Of Abiotic Resources Fossil Fuels Mj Manufacturing A1 A3 : 167.3327058192151
    • Depletion Of Abiotic Resources Fossil Fuels Mj Distribution A4 : 5.340333608646724
    • Depletion Of Abiotic Resources Fossil Fuels Mj Installation A5 : 0.9590635675393224
    • Depletion Of Abiotic Resources Fossil Fuels Mj Maintenance B2 : 0
    • Depletion Of Abiotic Resources Fossil Fuels Mj Repair B3 : 0
    • Depletion Of Abiotic Resources Fossil Fuels Mj Replacement B4 : 0
    • Depletion Of Abiotic Resources Fossil Fuels Mj Operational Energy Use B6 : 9218.33216076899
    • Depletion Of Abiotic Resources Fossil Fuels Mj End Of Life C1 C4 : 18.413417264498303
    • Depletion Of Abiotic Resources Fossil Fuels Mj Benefits Loads Beyond System Boundaries D : -55.90085105600177
    • Ecotoxicity Fresh Water Ctue Total Life Cycle : 626.2827152116887
    • Ecotoxicity Fresh Water Ctue Manufacturing A1 A3 : 89.27641512212058
    • Ecotoxicity Fresh Water Ctue Distribution A4 : 3.495622917609865
    • Ecotoxicity Fresh Water Ctue Installation A5 : 1.281091830579478
    • Ecotoxicity Fresh Water Ctue Maintenance B2 : 0
    • Ecotoxicity Fresh Water Ctue Repair B3 : 0
    • Ecotoxicity Fresh Water Ctue Replacement B4 : 0
    • Ecotoxicity Fresh Water Ctue Operational Energy Use B6 : 523.679144319735
    • Ecotoxicity Fresh Water Ctue End Of Life C1 C4 : 8.55044102164383
    • Ecotoxicity Fresh Water Ctue Benefits Loads Beyond System Boundaries D : -12.168598468527062
    • Emission Of Fine Particles Incidence Of Diseases Total Life Cycle : 0.00001551928262710728
    • Emission Of Fine Particles Incidence Of Diseases Manufacturing A1 A3 : 0.00000169207874007459
    • Emission Of Fine Particles Incidence Of Diseases Distribution A4 : 0.00000000518962812013
    • Emission Of Fine Particles Incidence Of Diseases Installation A5 : 0.00000000218162298686
    • Emission Of Fine Particles Incidence Of Diseases Maintenance B2 : 0
    • Emission Of Fine Particles Incidence Of Diseases Repair B3 : 0
    • Emission Of Fine Particles Incidence Of Diseases Replacement B4 : 0
    • Emission Of Fine Particles Incidence Of Diseases Operational Energy Use B6 : 0.0000137725206844515
    • Emission Of Fine Particles Incidence Of Diseases End Of Life C1 C4 : 0.0000000473119514742
    • Emission Of Fine Particles Incidence Of Diseases Benefits Loads Beyond System Boundaries D : -0.00000128753066425077
    • Exported Energy Mj By Energy Vector Total Life Cycle : 0.007864926261074488
    • Exported Energy Mj By Energy Vector Manufacturing A1 A3 : 0.0005832386213114103
    • Exported Energy Mj By Energy Vector Distribution A4 : 0
    • Exported Energy Mj By Energy Vector Installation A5 : 0
    • Exported Energy Mj By Energy Vector Maintenance B2 : 0
    • Exported Energy Mj By Energy Vector Repair B3 : 0
    • Exported Energy Mj By Energy Vector Replacement B4 : 0
    • Exported Energy Mj By Energy Vector Operational Energy Use B6 : 0
    • Exported Energy Mj By Energy Vector End Of Life C1 C4 : 0.007281687639763077
    • Exported Energy Mj By Energy Vector Benefits Loads Beyond System Boundaries D : 0
    • Freshwater Eutrophication Kg P Eq Total Life Cycle : 0.0007658475222587013
    • Freshwater Eutrophication Kg P Eq Manufacturing A1 A3 : 0.00003875521557283609
    • Freshwater Eutrophication Kg P Eq Distribution A4 : 0.00000005025693043139
    • Freshwater Eutrophication Kg P Eq Installation A5 : 0.00000006113816043733
    • Freshwater Eutrophication Kg P Eq Maintenance B2 : 0
    • Freshwater Eutrophication Kg P Eq Repair B3 : 0
    • Freshwater Eutrophication Kg P Eq Replacement B4 : 0
    • Freshwater Eutrophication Kg P Eq Operational Energy Use B6 : 0.0007238536558658674
    • Freshwater Eutrophication Kg P Eq End Of Life C1 C4 : 0.00000312725572912903
    • Freshwater Eutrophication Kg P Eq Benefits Loads Beyond System Boundaries D : -0.0000049219356822036
    • Hazardous Waste Disposed Of Kg Total Life Cycle : 116.5632860115921
    • Hazardous Waste Disposed Of Kg Manufacturing A1 A3 : 116.49886082218991
    • Hazardous Waste Disposed Of Kg Distribution A4 : 0.000355594508998097
    • Hazardous Waste Disposed Of Kg Installation A5 : 0.056255463994370036
    • Hazardous Waste Disposed Of Kg Maintenance B2 : 0
    • Hazardous Waste Disposed Of Kg Repair B3 : 0
    • Hazardous Waste Disposed Of Kg Replacement B4 : 0
    • Hazardous Waste Disposed Of Kg Operational Energy Use B6 : 0
    • Hazardous Waste Disposed Of Kg End Of Life C1 C4 : 0.007814130898814818
    • Hazardous Waste Disposed Of Kg Benefits Loads Beyond System Boundaries D : -69.1540361576551
    • Human Toxicity Carcinogenic Effects Ctuh Total Life Cycle : 0.00000338870513925505
    • Human Toxicity Carcinogenic Effects Ctuh Manufacturing A1 A3 : 0.00000333921215239279
    • Human Toxicity Carcinogenic Effects Ctuh Distribution A4 : 0.00000000000488692071
    • Human Toxicity Carcinogenic Effects Ctuh Installation A5 : 0.00000000000933582199
    • Human Toxicity Carcinogenic Effects Ctuh Maintenance B2 : 0
    • Human Toxicity Carcinogenic Effects Ctuh Repair B3 : 0
    • Human Toxicity Carcinogenic Effects Ctuh Replacement B4 : 0
    • Human Toxicity Carcinogenic Effects Ctuh Operational Energy Use B6 : 0.00000004935247251245
    • Human Toxicity Carcinogenic Effects Ctuh End Of Life C1 C4 : 0.00000000012629160711
    • Human Toxicity Carcinogenic Effects Ctuh Benefits Loads Beyond System Boundaries D : -0.00000753214152845551
    • Human Toxicity Non Carcinogenic Effects Ctuh Total Life Cycle : 0.00000207558487593338
    • Human Toxicity Non Carcinogenic Effects Ctuh Manufacturing A1 A3 : 0.00000084596191305185
    • Human Toxicity Non Carcinogenic Effects Ctuh Distribution A4 : 0.00000000086634351707
    • Human Toxicity Non Carcinogenic Effects Ctuh Installation A5 : 0.00000000037658540274
    • Human Toxicity Non Carcinogenic Effects Ctuh Maintenance B2 : 0
    • Human Toxicity Non Carcinogenic Effects Ctuh Repair B3 : 0
    • Human Toxicity Non Carcinogenic Effects Ctuh Replacement B4 : 0
    • Human Toxicity Non Carcinogenic Effects Ctuh Operational Energy Use B6 : 0.00000122024906622243
    • Human Toxicity Non Carcinogenic Effects Ctuh End Of Life C1 C4 : 0.0000000081309677393
    • Human Toxicity Non Carcinogenic Effects Ctuh Benefits Loads Beyond System Boundaries D : -0.00000040629966988648
    • Impacts Related To Land Use Soil Quality Total Life Cycle : 9.005438884084311
    • Impacts Related To Land Use Soil Quality Manufacturing A1 A3 : 0.3591888554120133
    • Impacts Related To Land Use Soil Quality Distribution A4 : 0
    • Impacts Related To Land Use Soil Quality Installation A5 : 0.0011106347706233758
    • Impacts Related To Land Use Soil Quality Maintenance B2 : 0
    • Impacts Related To Land Use Soil Quality Repair B3 : 0
    • Impacts Related To Land Use Soil Quality Replacement B4 : 0
    • Impacts Related To Land Use Soil Quality Operational Energy Use B6 : 8.630048259355211
    • Impacts Related To Land Use Soil Quality End Of Life C1 C4 : 0.015091134546463469
    • Impacts Related To Land Use Soil Quality Benefits Loads Beyond System Boundaries D : 0
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Total Life Cycle : 475.48777057701216
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Manufacturing A1 A3 : 79.73904108017243
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Distribution A4 : 0.0009515837189957326
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Installation A5 : 0.018986990537667277
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Maintenance B2 : 0
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Repair B3 : 0
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Replacement B4 : 0
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Operational Energy Use B6 : 395.50175860715143
    • Ionizing Radiation Human Health Kbq Of U235 Equiv End Of Life C1 C4 : 0.2270323154316693
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Benefits Loads Beyond System Boundaries D : -0.7481206650094212
    • Marine Aquatic Eutrophication Kg Of N Equiv Total Life Cycle : 0.25053755441540076
    • Marine Aquatic Eutrophication Kg Of N Equiv Manufacturing A1 A3 : 0.009952444984024167
    • Marine Aquatic Eutrophication Kg Of N Equiv Distribution A4 : 0.0008916471156239322
    • Marine Aquatic Eutrophication Kg Of N Equiv Installation A5 : 0.00007881426192735652
    • Marine Aquatic Eutrophication Kg Of N Equiv Maintenance B2 : 0
    • Marine Aquatic Eutrophication Kg Of N Equiv Repair B3 : 0
    • Marine Aquatic Eutrophication Kg Of N Equiv Replacement B4 : 0
    • Marine Aquatic Eutrophication Kg Of N Equiv Operational Energy Use B6 : 0.2380696743256707
    • Marine Aquatic Eutrophication Kg Of N Equiv End Of Life C1 C4 : 0.0015449737281546365
    • Marine Aquatic Eutrophication Kg Of N Equiv Benefits Loads Beyond System Boundaries D : -0.0016977327806222957
    • Materials For Energy Recovery Kg Total Life Cycle : 0
    • Materials For Energy Recovery Kg Manufacturing A1 A3 : 0
    • Materials For Energy Recovery Kg Distribution A4 : 0
    • Materials For Energy Recovery Kg Installation A5 : 0
    • Materials For Energy Recovery Kg Maintenance B2 : 0
    • Materials For Energy Recovery Kg Repair B3 : 0
    • Materials For Energy Recovery Kg Replacement B4 : 0
    • Materials For Energy Recovery Kg Operational Energy Use B6 : 0
    • Materials For Energy Recovery Kg End Of Life C1 C4 : 0
    • Materials For Energy Recovery Kg Benefits Loads Beyond System Boundaries D : 0
    • Materials For Recycling Kg Total Life Cycle : 0.7926682016932832
    • Materials For Recycling Kg Manufacturing A1 A3 : 0.05653182749726318
    • Materials For Recycling Kg Distribution A4 : 0
    • Materials For Recycling Kg Installation A5 : 0
    • Materials For Recycling Kg Maintenance B2 : 0
    • Materials For Recycling Kg Repair B3 : 0
    • Materials For Recycling Kg Replacement B4 : 0
    • Materials For Recycling Kg Operational Energy Use B6 : 0
    • Materials For Recycling Kg End Of Life C1 C4 : 0.7361363741960201
    • Materials For Recycling Kg Benefits Loads Beyond System Boundaries D : 0
    • Net Use Of Fresh Water M3 Total Life Cycle : 0.7451973210346552
    • Net Use Of Fresh Water M3 Manufacturing A1 A3 : 0.17741878502259553
    • Net Use Of Fresh Water M3 Distribution A4 : 0.0005069861443390159
    • Net Use Of Fresh Water M3 Installation A5 : 0.00008024087598256003
    • Net Use Of Fresh Water M3 Maintenance B2 : 0
    • Net Use Of Fresh Water M3 Repair B3 : 0
    • Net Use Of Fresh Water M3 Replacement B4 : 0
    • Net Use Of Fresh Water M3 Operational Energy Use B6 : 0.5588461112313327
    • Net Use Of Fresh Water M3 End Of Life C1 C4 : 0.008345197760405428
    • Net Use Of Fresh Water M3 Benefits Loads Beyond System Boundaries D : -0.04953090166585037
    • Non Hazardous Waste Disposed Of Kg Total Life Cycle : 74.62505681833056
    • Non Hazardous Waste Disposed Of Kg Manufacturing A1 A3 : 6.208055314250175
    • Non Hazardous Waste Disposed Of Kg Distribution A4 : 0.00043684246559292397
    • Non Hazardous Waste Disposed Of Kg Installation A5 : 0.00881781106281384
    • Non Hazardous Waste Disposed Of Kg Maintenance B2 : 0
    • Non Hazardous Waste Disposed Of Kg Repair B3 : 0
    • Non Hazardous Waste Disposed Of Kg Replacement B4 : 0
    • Non Hazardous Waste Disposed Of Kg Operational Energy Use B6 : 66.88570807097248
    • Non Hazardous Waste Disposed Of Kg End Of Life C1 C4 : 1.5220387795794965
    • Non Hazardous Waste Disposed Of Kg Benefits Loads Beyond System Boundaries D : -1.7489471957742992
    • Ozone Depletion Kg Equivalent Cfc 11 Total Life Cycle : 0.00000422897404702702
    • Ozone Depletion Kg Equivalent Cfc 11 Manufacturing A1 A3 : 0.00000223521637289716
    • Ozone Depletion Kg Equivalent Cfc 11 Distribution A4 : 0.00000037875151742379
    • Ozone Depletion Kg Equivalent Cfc 11 Installation A5 : 0.00000000186077832525
    • Ozone Depletion Kg Equivalent Cfc 11 Maintenance B2 : 0
    • Ozone Depletion Kg Equivalent Cfc 11 Repair B3 : 0
    • Ozone Depletion Kg Equivalent Cfc 11 Replacement B4 : 0
    • Ozone Depletion Kg Equivalent Cfc 11 Operational Energy Use B6 : 0.00000157399901383271
    • Ozone Depletion Kg Equivalent Cfc 11 End Of Life C1 C4 : 0.00000003914636454811
    • Ozone Depletion Kg Equivalent Cfc 11 Benefits Loads Beyond System Boundaries D : -0.00000053242134425796
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Total Life Cycle : 0.832647291336174
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Manufacturing A1 A3 : 0.03919282221488201
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Distribution A4 : 0.003134324904393993
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Installation A5 : 0.00022106245715313908
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Maintenance B2 : 0
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Repair B3 : 0
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Replacement B4 : 0
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Operational Energy Use B6 : 0.7854152170937658
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv End Of Life C1 C4 : 0.004683864665979007
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Benefits Loads Beyond System Boundaries D : -0.008132690628743661
    • Radioactive Waste Disposed Of Kg Total Life Cycle : 0.018240939977933066
    • Radioactive Waste Disposed Of Kg Manufacturing A1 A3 : 0.0027501755189417785
    • Radioactive Waste Disposed Of Kg Distribution A4 : 0.00008533285249088579
    • Radioactive Waste Disposed Of Kg Installation A5 : 0.00000291161417265555
    • Radioactive Waste Disposed Of Kg Maintenance B2 : 0
    • Radioactive Waste Disposed Of Kg Repair B3 : 0
    • Radioactive Waste Disposed Of Kg Replacement B4 : 0
    • Radioactive Waste Disposed Of Kg Operational Energy Use B6 : 0.015336669982120205
    • Radioactive Waste Disposed Of Kg End Of Life C1 C4 : 0.00006585001020754236
    • Radioactive Waste Disposed Of Kg Benefits Loads Beyond System Boundaries D : -0.0008107601079689234
    • Terrestrial Eutrophication Mole Of N Equiv Total Life Cycle : 2.9797789610858905
    • Terrestrial Eutrophication Mole Of N Equiv Manufacturing A1 A3 : 0.10834881473971202
    • Terrestrial Eutrophication Mole Of N Equiv Distribution A4 : 0.009656856677285075
    • Terrestrial Eutrophication Mole Of N Equiv Installation A5 : 0.0010386323365572912
    • Terrestrial Eutrophication Mole Of N Equiv Maintenance B2 : 0
    • Terrestrial Eutrophication Mole Of N Equiv Repair B3 : 0
    • Terrestrial Eutrophication Mole Of N Equiv Replacement B4 : 0
    • Terrestrial Eutrophication Mole Of N Equiv Operational Energy Use B6 : 2.8429561953056695
    • Terrestrial Eutrophication Mole Of N Equiv End Of Life C1 C4 : 0.017778462026666445
    • Terrestrial Eutrophication Mole Of N Equiv Benefits Loads Beyond System Boundaries D : -0.019698116585366188
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 17.616173486780713
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 17.616173486780713
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Maintenance B2 : 0
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Repair B3 : 0
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Replacement B4 : 0
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 : 0
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 0
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Benefits Loads Beyond System Boundaries D : 0
    • Total Use Of Primary Energy During The Life Cycle Mj Total Life Cycle : 10968.003236631179
    • Total Use Of Primary Energy During The Life Cycle Mj Manufacturing A1 A3 : 179.85230951757643
    • Total Use Of Primary Energy During The Life Cycle Mj Distribution A4 : 5.340368522922579
    • Total Use Of Primary Energy During The Life Cycle Mj Installation A5 : 1.041435655741013
    • Total Use Of Primary Energy During The Life Cycle Mj Maintenance B2 : 0
    • Total Use Of Primary Energy During The Life Cycle Mj Repair B3 : 0
    • Total Use Of Primary Energy During The Life Cycle Mj Replacement B4 : 0
    • Total Use Of Primary Energy During The Life Cycle Mj Operational Energy Use B6 : 10762.422528566605
    • Total Use Of Primary Energy During The Life Cycle Mj End Of Life C1 C4 : 19.346594368332823
    • Total Use Of Primary Energy During The Life Cycle Mj Benefits Loads Beyond System Boundaries D : -56.872945032222816
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 1557.6254206622039
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 12.519468758272179
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0.00003491427585387772
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0.08237208820169055
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Maintenance B2 : 0
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Repair B3 : 0
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Replacement B4 : 0
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 : 1544.0903677976196
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 0.9331771038345278
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Benefits Loads Beyond System Boundaries D : -0.9720939762210374
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 17.616173486780713
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 17.616173486780713
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Maintenance B2 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Repair B3 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Replacement B4 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Benefits Loads Beyond System Boundaries D : 0
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 9392.761642482199
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 149.71666727252347
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 5.340333608646724
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0.9590635675393224
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Maintenance B2 : 0
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Repair B3 : 0
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Replacement B4 : 0
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 : 9218.33216076899
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 18.413417264498303
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Benefits Loads Beyond System Boundaries D : -55.90085105600177
    • Use Of Non Renewable Secondary Fuels Mj Total Life Cycle : 0
    • Use Of Non Renewable Secondary Fuels Mj Manufacturing A1 A3 : 0
    • Use Of Non Renewable Secondary Fuels Mj Distribution A4 : 0
    • Use Of Non Renewable Secondary Fuels Mj Installation A5 : 0
    • Use Of Non Renewable Secondary Fuels Mj Maintenance B2 : 0
    • Use Of Non Renewable Secondary Fuels Mj Repair B3 : 0
    • Use Of Non Renewable Secondary Fuels Mj Replacement B4 : 0
    • Use Of Non Renewable Secondary Fuels Mj Operational Energy Use B6 : 0
    • Use Of Non Renewable Secondary Fuels Mj End Of Life C1 C4 : 0
    • Use Of Non Renewable Secondary Fuels Mj Benefits Loads Beyond System Boundaries D : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 2.9708578693623635
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 2.9708578693623635
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Maintenance B2 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Repair B3 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Replacement B4 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Benefits Loads Beyond System Boundaries D : 0
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 1554.6545627928415
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 9.548610888909815
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0.00003491427585387772
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0.08237208820169055
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Maintenance B2 : 0
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Repair B3 : 0
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Replacement B4 : 0
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 : 1544.0903677976196
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 0.9331771038345278
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Benefits Loads Beyond System Boundaries D : -0.9720939762210374
    • Use Of Renewable Secondary Fuels Mj Total Life Cycle : 0
    • Use Of Renewable Secondary Fuels Mj Manufacturing A1 A3 : 0
    • Use Of Renewable Secondary Fuels Mj Distribution A4 : 0
    • Use Of Renewable Secondary Fuels Mj Installation A5 : 0
    • Use Of Renewable Secondary Fuels Mj Maintenance B2 : 0
    • Use Of Renewable Secondary Fuels Mj Repair B3 : 0
    • Use Of Renewable Secondary Fuels Mj Replacement B4 : 0
    • Use Of Renewable Secondary Fuels Mj Operational Energy Use B6 : 0
    • Use Of Renewable Secondary Fuels Mj End Of Life C1 C4 : 0
    • Use Of Renewable Secondary Fuels Mj Benefits Loads Beyond System Boundaries D : 0
    • Use Of Secondary Materials Kg Total Life Cycle : 0
    • Use Of Secondary Materials Kg Manufacturing A1 A3 : 0
    • Use Of Secondary Materials Kg Distribution A4 : 0
    • Use Of Secondary Materials Kg Installation A5 : 0
    • Use Of Secondary Materials Kg Maintenance B2 : 0
    • Use Of Secondary Materials Kg Repair B3 : 0
    • Use Of Secondary Materials Kg Replacement B4 : 0
    • Use Of Secondary Materials Kg Operational Energy Use B6 : 0
    • Use Of Secondary Materials Kg End Of Life C1 C4 : 0
    • Use Of Secondary Materials Kg Benefits Loads Beyond System Boundaries D : 0
    • Water Use M3 Eq Total Life Cycle : 31.934620193709776
    • Water Use M3 Eq Manufacturing A1 A3 : 7.620890563694502
    • Water Use M3 Eq Distribution A4 : 0.021775054899360734
    • Water Use M3 Eq Installation A5 : 0.003497843065444468
    • Water Use M3 Eq Maintenance B2 : 0
    • Water Use M3 Eq Repair B3 : 0
    • Water Use M3 Eq Replacement B4 : 0
    • Water Use M3 Eq Operational Energy Use B6 : 23.98174454222139
    • Water Use M3 Eq End Of Life C1 C4 : 0.30671218982908127
    • Water Use M3 Eq Benefits Loads Beyond System Boundaries D : -2.127269994446955
    • Air Pollution M3 Total Life Cycle : 0
    • Air Pollution M3 Manufacturing A1 A3 : 0
    • Air Pollution M3 Distribution A4 : 0
    • Air Pollution M3 Installation A5 : 0
    • Air Pollution M3 Maintenance B2 : 0
    • Air Pollution M3 Repair B3 : 0
    • Air Pollution M3 Replacement B4 : 0
    • Air Pollution M3 Operational Energy Use B6 : 0
    • Air Pollution M3 End Of Life C1 C4 : 0
    • Air Pollution M3 Benefits Loads Beyond System Boundaries D : 0
    • Water Pollution M3 Total Life Cycle : 0
    • Water Pollution M3 Manufacturing A1 A3 : 0
    • Water Pollution M3 Distribution A4 : 0
    • Water Pollution M3 Installation A5 : 0
    • Water Pollution M3 Maintenance B2 : 0
    • Water Pollution M3 Repair B3 : 0
    • Water Pollution M3 Replacement B4 : 0
    • Water Pollution M3 Operational Energy Use B6 : 0
    • Water Pollution M3 End Of Life C1 C4 : 0
    • Water Pollution M3 Benefits Loads Beyond System Boundaries D : 0
  • General Attributes
    • Product Or Component Type : contactor
    • Range Of Product : 8502S
  • Environment Attributes
    • China ROHS url : https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=exportPdfRoHSChina&pid=507691&lang=en-us
    • Take Back : No
    • Recycled Metal Content At Cr Level : 0 %
    • China ROHS Regulation : X
    • Carbon Footprint : 433.6610993686852
    • Environmental Disclosure : ENVPEP2506044EN
    • EU ROHS Directive : Not compliant
    • Nema Degree Of Protection : not rated (open device)
    • Nema Size : 1
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP2506044EN
    • Pep Verification Date : 2025-09-01
    • PCR Version : PEP-PCR-ed4-2021 09 06
    • PSR Version : PSR-0005-ed3-2023 12 08
    • Type Of Verification For The Pep : Independent internal review
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Specifications
    • Country of Origin : Mexico
    • Compliance : TAA