Motor controller, TeSys T, Motor Management, DeviceNet, 6 logic inputs, 3 relay logic outputs, 0.4 to 8A, 24VDC

MTR Management CTRLler - Devic

SQDLTMR08DBD LTMR08DBD 3389119404747
862.22 / EA
http://schema.org/OutOfStock
  • Country of Origin: South Korea
  • Depth: 122.5 mm
  • Warranty Length: 18 mth
TeSys T is a motor management system that provides full motor monitoring, control, and protection when used with short circuit protection and a contactor. TeSys T manages most critical processes while reducing downtime and increasing productivity. TeSys T is a flexible system that integrates seamlessly into your automation system through five major communication protocols. TeSys T predicts what will happen in the process, as it accurately monitors current, voltage, and power over a wide range. This controller is the central component in the motor management system. The module manages the basic functions of the motor management system. It manages the measurement of 3 phase current via integral current transformers from 0.4 to 100 A or up to 810 A by external current transformers. It also measures ground current with internal or external ground sensors, motor temperature and the inputs and outputs for the various motor control modes, detected fault management and other functions. DeviceNet protocol is used by this controller. This module has 6 discrete logic inputs, 3 relay logic outputs and a relay output for detected fault signaling overload relay. The current range of this controller is 0.4 to 8 amperes. 24 VDC is used to power this controller. Controller is 2.40 inches tall, 3.58 inches wide and 4.82 inches deep. Controller weighs 1.17 lbs. Controller has the following certifications: UL, CSA NOM, ATEX, BV, EAC, RINA, LROS, DNV, ABS, GL, KERI, RMRoS, C-Tick and CCC.
QTY
  • Features
  • Specifications
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Communications & Management Attributes
    • Communication Port Protocol : DeviceNet
  • Conformance Attributes
    • Product Certifications : LROS (Lloyds register of shipping), DNV, GL, UL, C-tick, BV, CSA, ATEX, RINA, KERI, CCC, ABS, EAC, RMRoS, NOM
    • Standards : EN 60947-4-1, CSA C22.2 No 14, UL 508, IACS E10, IEC 60947-4-1
  • Complementary Attributes
    • Ui Rated Insulation Voltage : 690 V EN/IEC 60947-1, 690 V CSA C22.2 No 14, 690 V UL 508
    • Uimp Rated Impulse Withstand Voltage : 6 kV current or voltage measurement circuit EN/IEC 60947-4-1, 0.8 kV communication circuit EN/IEC 60947-4-1, 0.8 kV supply, inputs and outputs EN/IEC 60947-4-1
    • Maximum Operating Frequency : 2 Hz
    • Maximum Operating Rate : 1800 cyc/h
    • Short Circuit Withstand : 100 kA conforming to EN/IEC 60947-4-1
    • Us Rated Supply Voltage : 24 V DC
  • Important Information Attributes
    • Persona Type Ids : EU, LC, OM, OM8, PB
    • Persona Type Names : End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Associated Fuse Rating : 4 A gG output, 0.5 A gG control circuit
    • Contacts Type And Composition : 1 NO + 1 NC fault signal, 3 NO
    • Electromagnetic Compatibility : temperature sensor: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5, control circuit: surges (serial mode), 1 kV, conforming to EN/IEC 61000-4-5, electrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2, control circuit: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5, communication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5, relay outputs and supply: surges (serial mode), 2 kV, conforming to EN/IEC 61000-4-5, relay outputs and supply: surges (common mode), 4 kV, conforming to EN/IEC 61000-4-5, radiated RF fields, 3, 10 V/m, conforming to EN/IEC 61000-4-3, fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4, fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4, voltage dips and interruptions immunity test, 70 %, 500 ms, conforming to EN/IEC 61000-4-11, conducted RF disturbances, 10 V, conforming to EN/IEC 61000-4-6, temperature sensor: surges (serial mode), 0.5 kV, conforming to EN/IEC 61000-4-5
    • Fire Resistance : 650 °C EN/IEC 60695-2-12, 960 °C UL 94
    • Load Current : 5 A 250 V AC logic output, 5 A 30 V DC logic output
    • Measurement Accuracy : +/- 30 min/year internal clock, +/- 30 min/year internal clock, 5...15 % earth fault current internal measurement, 1 % voltage 100...830 V), 3 % power factor, 5 % earth fault current external measurement, +/- 30 min/year internal clock, +/- 30 min/year internal clock, 0,02 Temperature, 1 % current, 5 % active and reactive power
    • Mechanical Robustness : vibrations mounted on symmetrical rail1 Gn, 5...300 Hz EN/IEC 60068-2-6, vibrations plate mounted4 Gn, 5...300 Hz EN/IEC 60068-2-6, shocks half sine wave acceleration15 Gn for 11 ms EN/IEC 60068-2-27
    • Metering Type : phase current I1, I2, I3 RMS, temperature, earth-fault current, average current Iavg, imbalance current
    • Network And Machine Diagnosis Type : fault recording, waiting time after overload tripping, remaining operating time before overload tripping, phase fault and earth fault trip counters, starting current and time, trip history information, trip context information, motor control command recording, running hours counter/operating time, event recording
    • Permissible Power : 480 VA AC-15), Ie = 2 A, 500000 cycles output), 30 W DC-13), Ie = 1.25 A, 500000 cycles output)
    • Protection Type : thermal overload protection, overload, power factor variation, reverse polarity protection, earth-leakage protection, thermal protection, overload (long time), phase failure, load fluctuation, phase unbalance, locked rotor
    • Protective Treatment : 12 x 24 hour cycles EN/IEC 60068-2-30, 48 h EN/IEC 60070-2-11, TH EN/IEC 60068
    • Connections Terminals : control circuit connector 1 0.25-2.5 mm² AWG 24...AWG 14)flexible without cable end, control circuit connector 2 0.2-1.5 mm² AWG 24...AWG 14)flexible without cable end, control circuit connector 2 0.2-1 mm² AWG 24...AWG 14)solid without cable end, control circuit connector 1 0.25-2.5 mm² AWG 24...AWG 14)flexible with cable end, control circuit connector 1 0.2-2.5 mm² AWG 24...AWG 14)flexible without cable end, control circuit connector 1 0.2-2.5 mm² AWG 24...AWG 14)solid without cable end, control circuit connector 2 0.2-1 mm² AWG 24...AWG 14)flexible with cable end, control circuit connector 2 0.5-1.5 mm² AWG 24...AWG 14)flexible without cable end
    • Carbon Footprint Of The Distribution Phase A4 : 0.06652488226573267, 0.1 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 0.9889177479245208, 1 kg CO2 eq.
    • Carbon Footprint Of The Installation Phase A5 : 0.2 kg CO2 eq., 0.19771895310322815
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 18 kg CO2 eq., 17.98041281845835
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 5 kg CO2 eq., 4.971249437669018
    • Medium Desc : Motor controller, TeSys T, Motor Management, DeviceNet, 6 logic inputs, 3 relay logic outputs, 0.4 to 8A, 24VDC
    • Local Data Status : Publishable
    • Local Publishable Date : 2026-02-03
    • Global Commercial Status : End of commerc. announced
    • Return Indicator : N
    • Stocking Flag : Y
    • Device Type : Relay, Control & Measurement - Protection relay
    • Serviceability : Yes
    • Traceability : Yes
    • Field Service Division : PPIBS
    • Average Life Duration : 15 year(s)
    • Legacy Weee Scope : In
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI100411EN_V2
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : Yes
    • Rohs Eur Status : Compliant By Exemption
    • Rohs Eur Full Compliance Status : Compliant By Exemption
    • China Rohs In Scope : Yes
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Product Kit Identifier : N
    • Bus Type : DeviceNet ISO 1198 1...64 125...500 kbit/s, terminal block 4 twisted shielded pairs cable
    • Compatibility Code : LTMR
    • Connection Pitch : 5.08 mm
    • Current Consumption : 56...127 mA
    • Current State 0 Guaranteed : logic input < 5 V <= 15 mA 5 ms
    • Current State 1 Guaranteed : logic input < 15 V 2...15 mA 15 ms
    • Device Application : equipment monitoring and control
    • Device Short Name : LTMR
    • Energy Efficiency Optimized : False
    • Halogen Free Status : Halogen free plastic parts product
    • Measurement Current : 0.4-8 A
    • Overvoltage Category : III
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Name : TeSys T
    • Product Or Component Type : motor controller
    • Range : TeSys
    • Returnability : No
    • Short Circuit Withstand : 100 kA conforming to EN/IEC 60947-4-1
    • Software Version : v6.2.5-6
    • Supply Voltage Limits : 20.4-26.24 V DC
    • Sustainable Packaging : Yes
    • Tightening Torque : control circuit: 0.5-0.6 N.m flat screwdriver 3 mm
    • Total Lifecycle Carbon Footprint : 24 kg CO2 eq.
    • Web Services : web server
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Pep Code : ENVPEP0603008EN
    • Database Version : 2024-01
    • Pep Verification Date : 2025-11-10
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent internal review
    • Data Source : extrapolated product
    • Functional Unit Description : Other switchgear and controlgear solutions mentioned in the scope (e.g. fuses TC32, all-or-nothing relays TC94, Measuring relays and protection equipment TC95), apply the general rules of PCR and mention in the accompanying report the functional unit, the reference product characteristics, the reference lifetime and the use scenario which are applied consistently with the relevant IEC technical standards.
    • Functional Unit Unit : unit
    • Energy Model Manufacturing A1 A3 2 : Electricity Mix; Low voltage; 2020; China, CN
    • Energy Model Installation A5 2 : No energy used
    • Energy Model Use B6 2 : Electricity Mix; Low voltage; 2020; Europe, EU-27
    • Energy Model End Of Life C1 C4 2 : Global, European and French datasets are used.
    • Height Nominal : 61 mm
    • Width Nominal : 91 mm
  • Environment Attributes Main
    • Ambient Air Temperature For Operation : -20-60 °C, -20-60 °C
    • Operating Altitude : <= 6561.68 ft (2000 m) without derating, <= 6561.68 ft (2000 m) without derating, <= 6561.68 ft (2000 m) without derating, <= 6561.68 ft (2000 m) without derating
    • Take Back : Nej
    • Halogene Performance : Halogen free plastic parts product
    • Recycled Metal Content At Cr Level : 0 %
    • China Rohs Regulation : X
    • Mercury Free : Yes
    • Carbon Footprint : 24.20482383942085
    • Ambient Air Temperature For Storage : -40-80 °C
    • Circularity Profile : ENVEOLI100411EN_V2
    • Environmental Disclosure : ENVPEP0603008EN
    • Eu Rohs Directive : Compliant By Exemption
    • Halogen Content Performance : Halogen free plastic parts product
    • Ip Degree Of Protection : IP20
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP0603008EN
    • Pep Verification Date : 2025-11-10
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Product Or Component Type : motor controller
  • ETIM
    • ETIM 8 : EC002572
    • ETIM 9 : EC002572
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Input Attributes
    • Input Current : 7 mA
    • Logic Input Number : 6
  • Specifications
    • Country of Origin : South Korea
    • Depth : 122.5 mm