motor controller LTMR TeSys T - 100..240 V AC 100 A for Profibus DP

motor controller LTMR TeSys T - 100..240 V AC 100 A for Profibus DP

SQDLTMR100PFM LTMR100PFM 785901498612
756.38 / EACH
  • Certifications: ABS, ATEX, BV, CCC, CSA, C-tick, DNV, EAC, GL, KERI, LROS (Lloyds Register Of Shipping), NOM, RINA, RMRoS, UL
  • Current: 8-62.8 mA
  • Depth: 122.5 mm
  • Height: 61 mm
  • Net Weight: 0.53 kg
  • Standard: CSA C22.2 No 14, EN 60947-4-1, IACS E10, IEC 60947-4-1, UL 508
  • Storage Temperature: -40-80 °C
  • Width: 91 mm
  • Specifications
  • Maximum Depth : 122.5 mm
  • Bus Type : Profibus DP polarised 2-wire RS485 1...125 9.6 kbit/s...12 Mbit/s, SUB-D 9 2 shielded twisted pairs, type A || Profibus DP polarised 2-wire RS485 1...125 9.6 kbit/s...12 Mbit/s, terminal block 2 shielded twisted pairs, type A
  • Load Current : 5 A 250 V AC logic output || 5 A 30 V DC logic output
  • Current Consumption : 8...62.8 mA
  • Current State 1 Guaranteed : logic input 79...264 V >= 2 mA 25 ms
  • Tightening Torque : control circuit 0.5-0.6 N.m flat 3 mm
  • Web Services : web server
  • Mechanical Robustness : vibrations mounted on symmetrical rail1 Gn, 5...300 Hz EN/IEC 60068-2-6 || vibrations plate mounted4 Gn, 5...300 Hz EN/IEC 60068-2-6 || shocks half sine wave acceleration15 Gn for 11 ms EN/IEC 60068-2-27
  • [Uimp] Rated Impulse Withstand Voltage : 4 kV supply, inputs and outputs EN/IEC 60947-4-1 || 6 kV current or voltage measurement circuit EN/IEC 60947-4-1 || 0.8 kV communication circuit EN/IEC 60947-4-1
  • Electromagnetic Compatibility : electrostatic discharge, 3 8 kV air, 6 kV contact)EN/IEC 61000-4-2 || surges 2 kV)EN/IEC 61000-4-5 || surges 2 kV)EN/IEC 61000-4-5 || surges 4 kV)EN/IEC 61000-4-5 || surges 2 kV)EN/IEC 61000-4-5 || radiated RF fields, 3 10 V/m)EN/IEC 61000-4-3 || fast transients immunity test, level 3 2 kV)EN/IEC 61000-4-4 || fast transients immunity test, level 4 4 kV)EN/IEC 61000-4-4 || voltage dips and interruptions immunity test 70 %, 500 ms)EN/IEC 61000-4-11 || conducted RF disturbances 10 V)EN/IEC 61000-4-6 || surges 0.5 kV)EN/IEC 61000-4-5 || surges 1 kV)EN/IEC 61000-4-5 || surges 1 kV)EN/IEC 61000-4-5
  • Metering Type : earth-fault current || phase current I1, I2, I3 RMS || temperature || imbalance current || average current Iavg
  • Ambient Air Temperature For Storage : -40-80 °C
  • Standards : EN 60947-4-1 || IACS E10 || CSA C22.2 No 14 || UL 508 || IEC 60947-4-1
  • Maximum Width : 91 mm
  • Range : TeSys
  • Protective Treatment : 12 x 24 hour cycles EN/IEC 60068-2-30 || 48 h EN/IEC 60070-2-11 || TH EN/IEC 60068
  • Overvoltage Category : III
  • Contacts Type And Composition : 1 NO + 1 NC fault signal || 3 NO
  • Net Weight : 0.53 kg
  • Compatibility Code : LTMR
  • Current State 0 Guaranteed : logic input 0...40 V <= 15 mA 25 ms
  • Input Current : 3.1 mA 100 V || 7.5 mA 240 V
  • Permissible Power : 480 VA AC-15), Ie = 2 A, 500000 cycles output) || 30 W DC-13), Ie = 1.25 A, 500000 cycles output)
  • Measurement Current : 5-100 A
  • Fire Resistance : 650 °C EN/IEC 60695-2-12 || 960 °C UL 94
  • Associated Fuse Rating : 4 A gG output || 0.5 A gG control circuit
  • Protection Type : thermal overload protection || power factor variation || overload || locked rotor || thermal protection || reverse polarity protection || phase unbalance || earth-leakage protection || phase failure || load fluctuation || overload (long time)
  • Communication Port Protocol : Profibus DP
  • Connections - Terminals : control circuit connector 1 0.25-2.5 mm² AWG 24...AWG 14)flexible with cable end || control circuit connector 1 0.2-2.5 mm² AWG 24...AWG 14)flexible without cable end || control circuit connector 1 0.25-2.5 mm² AWG 24...AWG 14)flexible without cable end || control circuit connector 1 0.2-2.5 mm² AWG 24...AWG 14)solid without cable end || control circuit connector 2 0.2-1 mm² AWG 24...AWG 14)flexible with cable end || control circuit connector 2 0.2-1.5 mm² AWG 24...AWG 14)flexible without cable end || control circuit connector 2 0.5-1.5 mm² AWG 24...AWG 14)flexible without cable end || control circuit connector 2 0.2-1 mm² AWG 24...AWG 14)solid without cable end
  • Ip Degree Of Protection : IP20
  • Network And Machine Diagnosis Type : starting current and time || trip history information || running hours counter/operating time || phase fault and earth fault trip counters || trip context information || event recording || remaining operating time before overload tripping || motor control command recording || waiting time after overload tripping || fault recording
  • Product Certifications : KERI || RMRoS || ABS || UL || ATEX || NOM || RINA || BV || CCC || GL || DNV || CSA || LROS (Lloyds register of shipping) || EAC || C-tick
  • Ambient Air Temperature For Operation : -20-60 °C
  • Short-Circuit Withstand : 100 kA EN/IEC 60947-4-1
  • Device Short Name : LTMR
  • Product Or Component Type : motor controller
  • Pollution Degree : 3
  • Operating Altitude : <= 6561.68 ft (2000 m) without derating
  • Maximum Operating Frequency : 2 Hz
  • Device Application : equipment monitoring and control
  • Connection Pitch : 5.08 mm
  • Measurement Accuracy : 5...15 % earth fault current internal measurement || 1 % voltage 100...830 V) || 3 % power factor || 5 % earth fault current external measurement || +/- 30 min/year internal clock || 0,02 Temperature || 5 % active and reactive power || 0,02 current
  • Maximum Operating Rate : 1800 cyc/h
  • [Ui] Rated Insulation Voltage : 690 V EN/IEC 60947-1 || 690 V CSA C22.2 No 14 || 690 V UL 508
  • Supply Voltage Limits : 93.5-264 V AC
  • Logic Input Number : 6
  • Maximum Height : 61 mm
  • Product Name : TeSys T
  • [Us] Rated Supply Voltage : 100...240 V AC 50/60 Hz