Motor circuit protector, PowerPacT P, 1200A, 3 pole, 600VAC, 25kA, lugs, ET1.0l, 80%

Motor circuit protector, Power

SQDPJL36120M70 PJL36120M70 SQDPJL36120M70
0.00 / EA
http://schema.org/OutOfStock
  • Country of Origin: USA
  • Depth: 8.05 in
  • Height: 16.16 in
  • Length: 30 mm
  • Net Weight: 32 lb
  • Warranty Length: 18 mth
  • Weight: 32 lb
  • Width: 8.27 in
PowerPacT P-Frame motor circuit protectors (MCP) are instantaneous-trip circuit breakers designed to offer short circuit protection for motors. The unique design of the PowerPacT MCPs accommodates transient motor inrush current without nuisance tripping. These motor protectors accept the same accessories and terminals as the equivalent PowerPacT P circuit breaker. This unit has lugs on both the line and the load side This PowerPacT P, 1200A, 3 pole, motor protector has an interrupting rating of 25kA at 600VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT P motor circuit protectors comply to UL, CSA, NOM, and IEC standards and are CE marked.
QTY
  • Product Description
  • Features
  • Specifications
PowerPacT P-Frame motor circuit protectors (MCP) are instantaneous-trip circuit breakers designed to offer short circuit protection for motors. The unique design of the PowerPacT MCPs accommodates transient motor inrush current without nuisance tripping. These motor protectors accept the same accessories and terminals as the equivalent PowerPacT P circuit breaker. This unit has lugs on both the line and the load side This PowerPacT P, 1200A, 3 pole, motor protector has an interrupting rating of 25kA at 600VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT P motor circuit protectors comply to UL, CSA, NOM, and IEC standards and are CE marked.
  • Prop 65
    • WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Environment
    • Ambient Air Temperature For Operation : -25-70 °C
    • Standards : UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
    • Product Certifications : UL || CSA || NOM
    • Ip Degree Of Protection : front cover IP40
    • Pollution Degree : 3 IEC 60947-1
    • Ambient Air Temperature For Storage : -50-85 °C
    • Quality Labels : CE
    • Operating Altitude : < 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
  • Contractual warranty
    • Warranty : 18 months
  • Environmental data
    • Rohs Exemption Information : Yes
    • Mercury Free : Yes
    • Environmental Disclosure : ENVPEP2206033EN
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
    • Removable Battery : Yes
    • China Rohs Regulation : Product out of China RoHS scope. Substance declaration for your information.
    • Circularity Profile : ENVEOLI2206033EN
    • Take-Back : No
    • Pvc Free : Yes
    • Sustainable Packaging : Yes
    • Global Warming ; Total Life Cycle​ : 2 496 kg CO2 eq.
    • Eu Rohs Directive : Compliant with Exemptions
    • Carbon Footprint (Kg Co2 Eq, Total Life Cycle) : 2496.4221205021
  • Complementary
    • Mounting Mode : unit mount lug)
    • Network Frequency : 50/60 Hz
    • Terminal Identifier : AL1200P25K
    • [Ics] Rated Service Breaking Capacity : 35 kA 240 V AC 50/60 Hz IEC 60947-2 || 25 kA 380/415 V AC 50/60 Hz IEC 60947-2
    • [Ith] Conventional Free Air Thermal Current : 1200-1200 A
    • Trip Unit Technology : electronic, basic, ET 1.0, I
    • Trip Unit Name : ET 1.0
    • Height : 16.16 in
    • [Ue] Rated Operational Voltage : 600 V AC 50/60 Hz UL 489
    • Tightening Torque : 50-50 N.m 95-240 mm² (4 x AWG 3/0...500 kcmil) || 1.0-1.3 N.m
    • Mounting Support : lug
    • Breaking Capacity Code : J
    • Magnetic Tripping Current : 1800-10000 A
    • Local Signalling : 1 trip indicator green)
    • Number Of Slots : 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
    • Electrical Connection : lugs, line || lugs, load
    • Net Weight : 32 lb(US)
    • [Uimp] Rated Impulse Withstand Voltage : 8 kV IEC 60947-2
    • Control Type : toggle
    • Circuit Breaker Application : HACR rated
    • Wire Stripping Length : 30 mm
    • Line Rated Current : 1200-1200 A
    • Utilisation Category : category A
    • Long Time Pick-Up Adjustment Range : 1 In
    • Continuous Current Rating : 80 %
    • Breaking Capacity : AIR 100 kA 240 V AC 50/60 Hz UL 489 || AIR 65 kA 480 V AC 50/60 Hz UL 489 || AIR 25 kA 600 V AC 50/60 Hz UL 489 || Icu 65 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 50 kA 380/415 V AC 50/60 Hz IEC 60947-2
    • [Ui] Rated Insulation Voltage : 750 V IEC 60947-2
    • Suitability For Isolation : yes IEC 60947-2
    • Poles Description : 3P
    • Quantity Per Set : 1
    • Awg Gauge : 4 x AWG 3/0...500 kcmil aluminium/copper
    • Width : 8.27 in
    • Depth : 8.05 in
  • Specifications
    • Country of Origin : United States
    • Length : 30 mm
    • Width : 8.27 in
    • Height : 16.16 in
    • Weight : 32 lbs
    • Product Or Component Type : Motor Circuit Protector
    • Product Name : PowerPact P
    • Range : PowerPact
    • Device Application : distribution