Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 50kA, thermal magnetic, Everlink terminals

Motor circuit breaker, TeSys G

SQDGV4P115N GV4P115N 3606481310385
1116.32 / EA
http://schema.org/OutOfStock
  • Depth: 165 mm
  • Operating Position: Any Position
  • Warranty Length: 18 mth
TeSys GV motor circuit breaker, 3 poles (3P), 115A/690V, for protection of 3-phase motors 37-55kW@400V. It provides thermal magnetic protection and additional motor protection functions, breaking capacity Icu 50kA@400V, start-stop control by rotary handle, connection by Everlink BTR screw terminals. Thermal protection adjustable by dials with a setting current Ir in range 65-115A and a selectable tripping class 10 or 20, magnetic protection at 17 In. Additional protections have fixed pick-up and include short time delay protection Isd at 13 Ir, phase unbalance and loss protection, ground fault protection. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX).
QTY
  • Product Description
  • Features
  • Specifications
TeSys GV motor circuit breaker, 3 poles (3P), 115A/690V, for protection of 3-phase motors 37-55kW@400V. It provides thermal magnetic protection and additional motor protection functions, breaking capacity Icu 50kA@400V, start-stop control by rotary handle, connection by Everlink BTR screw terminals. Thermal protection adjustable by dials with a setting current Ir in range 65-115A and a selectable tripping class 10 or 20, magnetic protection at 17 In. Additional protections have fixed pick-up and include short time delay protection Isd at 13 Ir, phase unbalance and loss protection, ground fault protection. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX).
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Physical Attributes
    • Color : Gray RAL 7016)
  • Complementary Attributes
    • Line Rated Current : 115 A
    • Maximum Operating Rate : 25 cyc/h
    • Rated Current : 115 A
    • Rated Duty : continuous IEC 60947-4-1
    • Ue Rated Operational Voltage : 690 V AC 50/60 Hz IEC 60947-2
    • Ui Rated Insulation Voltage : 800 V AC 50/60 Hz IEC 60947-2
    • Uimp Rated Impulse Withstand Voltage : 8 kV IEC 60947-2
  • Important Information Attributes
    • Persona Type Ids : EU, LC, OM, OM8, PB, SC
    • Persona Type Names : End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, Electrician
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Control Type : rotary handle
    • Electrical Durability : 5000 cycles AC-3 415 V opening, 5000 cycles AC-3 415 V closing
    • Mechanical Robustness : vibrations +/- 1 mm 2...13.2 Hz IEC 60068-2-6, vibrations 0.7 gn 13.2...100 Hz IEC 60068-2-6, shocks 15 gn 11 ms IEC 60068-2-27
    • Motor Power Kw : 55-55 kW 500 V AC 50/60 Hz37-37 kW 400...415 V AC 50/60 Hz, 45-45 kW 400...415 V AC 50/60 Hz, 55-55 kW 400...415 V AC 50/60 Hz, 45-45 kW 500 V AC 50/60 Hz, 75-75 kW 500 V AC 50/60 Hz, 75-75 kW 660...690 V AC 50/60 Hz, 90-90 kW 660...690 V AC 50/60 Hz, 110-110 kW 660...690 V AC 50/60 Hz
    • Poles Description : 3P
    • Product Or Component Type : motor circuit breaker
    • Range : TeSys Deca
    • Tightening Torque : 9 N.m 16-95 mm², 5 N.m 1.5-10 mm²
    • Trip Unit Technology : electronic, thermal-magnetic
    • Utilisation Category : category A IEC 60947-2, AC-3 IEC 60947-4-1
    • Connections Terminals : EverLink BTR screw connectors (bottom): 1 cable(s) 2.5-70 mm² - flexibleEverLink BTR screw connectors (top): 1 cable(s) 1.5-70 mm² - solid, EverLink BTR screw connectors (top): 1 cable(s) 1.5-50 mm² - flexible, EverLink BTR screw connectors (bottom): 1 cable(s) 2.5-95 mm² - solid
    • Carbon Footprint Of The Distribution Phase A4 : 0.53042, 0.5 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 4.2742, 4 kg CO2 eq.
    • Carbon Footprint Of The Installation Phase A5 : 0.5 kg CO2 eq., 0.47268
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 13 kg CO2 eq., 12.543
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 74 kg CO2 eq., 74.322
    • R Magnetic Tripping Current : 1955-1955 A
    • Certificate Agency : IEC, UL, CSA, CCC, EAC, ATEX, EU-RO MR
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-04-05
    • Return Indicator : Y
    • Stocking Flag : N
    • Stock Policy : 2
    • Device Type : LV equipment - Low voltage circuit breaker
    • Serviceability : Yes
    • Traceability : Yes
    • Field Service Division : PPIBS
    • Average Life Duration : 15 year(s)
    • Manufacturing Carbon Footprint : 12.543
    • Use Carbon Footprint : 74.322
    • End Of Life Carbon Footprint : 4.2742
    • Weee Applicability : Finished product
    • Weee Scope : In
    • Weee Product Category : 5
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI1704004EN
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : Yes
    • Rohs Eur Status : Compliant By Exemption
    • Rohs Eur Conformity Date : 1903
    • Rohs Eur Full Compliance Status : Compliant By Exemption
    • China Rohs In Scope : Yes
    • China Rohs Label : 7
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Tier Id : 1
    • Tier : 1
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Product Kit Identifier : N
    • Device Application : motor protection
    • Device Short Name : GV4P
    • Direct Connector : without
    • Energy Efficiency Optimized : False
    • Fire Resistance : 960 °C IEC 60695-2-11
    • Halogen Free Status : Halogen free plastic parts product
    • Magnetic Tripping Current : 1955-1955 A
    • Mechanical Durability : 40000 cycles
    • Operating Position : any position
    • Phase Failure Sensitivity : yes IEC 60947-4-1
    • Power Dissipation Per Pole : 4.6 W
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Name : TeSys GV4
    • Range Of Product : TeSys GV4
    • Returnability : Yes
    • Software Version : v5.9.4
    • Suitability For Isolation : yes IEC 60947-1
    • Sustainable Packaging : Yes
    • Total Lifecycle Carbon Footprint : 92 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Ith Conventional Free Air Thermal Current : 115 A IEC 60947-4-1
    • Carbon Footprint Kg Co2 Eq Total Life Cycle : 92.1423
    • Warranty In Months : 18
    • Rated Current 1 : 115 A
    • Connections Terminals 119 Connections Terminals : EverLink BTR screw connectors
    • Pep Code : ENVPEP1704004EN
    • Database Version : 2022-01
    • Pep Verification Date : 2023-08-19
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed2-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
    • Data Source : referent product
    • Functional-unit Description : Protect during 20 years the motor against overloads and short-circuits in circuit with assigned voltage up to 690VAC and 115A rated current. This protection is ensured in accordance with the following parameters:& 10- Number of poles: 3& 10- Rated service breaking capacity Ics at 440VAC = 50kA (according to IEC 60947-2) & 10- Tripping curve: long time, short time and instantanous protections, dual class (10 and 20)
    • Functional-unit Quantity : 1
    • Functional-unit Unit : unité (unit)
    • Reference Lifetime, In Y : 20
    • Energy Model - Manufacturing [A1-a3] : Electricity Mix; Production mix; Low voltage; CZ
    • Energy Model - Installation [A5] : Electricity Mix; Production mix; Low voltage; UE-27
    • Energy Model - Use [B6] : Electricity Mix; Production mix; Low voltage; UE-27
    • Energy Model - End Of Life [C1-c4] : Electricity Mix; Production mix; Low voltage; UE-27
    • Recyclability Potential, In % : 49
    • Offer Owner Code : 190788
    • Pn : 1
    • Height Nominal : 155 mm
    • Width Nominal : 81 mm
    • Acidification (Ap) (Mole Of H+ Equiv) Operational Energy Use [B6] : 0.4241
    • Climate Change - Fossil Fuels ( Kg Co2 Eq.) Manufacturing [A1-a3] : 12.373
    • Climate Change - Fossil Fuels ( Kg Co2 Eq.) Operational Energy Use [B6] : 74.223
    • Climate Change - Fossil Fuels ( Kg Co2 Eq.) End Of Life [C1-c4] : 4.2322
    • Climate Change - Fossil Fuels ( Kg Co2 Eq.) Benefits/Loads Beyond System Boundaries [D] : -27.703
    • Climate Change - Total ( Kg Co2 Eq.) Total Life Cycle : 92.1423
    • Climate Change - Total ( Kg Co2 Eq.) Manufacturing [A1-a3] : 12.543
    • Climate Change - Total ( Kg Co2 Eq.) Operational Energy Use [B6] : 74.322
    • Climate Change - Total ( Kg Co2 Eq.) End Of Life [C1-c4] : 4.2742
    • Climate Change - Total ( Kg Co2 Eq.) Benefits/Loads Beyond System Boundaries [D] : -27.896
    • Depletion Of Abiotic Resources - Fossil Fuels (Mj) Total Life Cycle : 2252.2397
    • Depletion Of Abiotic Resources - Fossil Fuels (Mj) Manufacturing [A1-a3] : 208.77
    • Depletion Of Abiotic Resources - Fossil Fuels (Mj) Distribution [A4] : 6.4406
    • Depletion Of Abiotic Resources - Fossil Fuels (Mj) Installation [A5] : 4.9191
    • Depletion Of Abiotic Resources - Fossil Fuels (Mj) Operational Energy Use [B6] : 1893.5
    • Depletion Of Abiotic Resources - Fossil Fuels (Mj) End Of Life [C1-c4] : 138.61
    • Depletion Of Abiotic Resources - Fossil Fuels (Mj) Benefits/Loads Beyond System Boundaries [D] : -618.92
    • Ecotoxicity (Fresh Water) (Ctue) Total Life Cycle : 3218.4563
    • Ecotoxicity (Fresh Water) (Ctue) Manufacturing [A1-a3] : 2259
    • Ecotoxicity (Fresh Water) (Ctue) Distribution [A4] : 2.1753
    • Ecotoxicity (Fresh Water) (Ctue) Installation [A5] : 3.241
    • Ecotoxicity (Fresh Water) (Ctue) Operational Energy Use [B6] : 800.39
    • Ecotoxicity (Fresh Water) (Ctue) End Of Life [C1-c4] : 153.65
    • Ecotoxicity (Fresh Water) (Ctue) Benefits/Loads Beyond System Boundaries [D] : -489.95
    • Hazardous Waste Disposed Of (Kg) Manufacturing [A1-a3] : 108.94
    • Hazardous Waste Disposed Of (Kg) End Of Life [C1-c4] : 1.7245
    • Hazardous Waste Disposed Of (Kg) Benefits/Loads Beyond System Boundaries [D] : -712.09
    • Impacts Related To Land Use/Soil Quality (-) Operational Energy Use [B6] : 1.4788
    • Impacts Related To Land Use/Soil Quality (-) End Of Life [C1-c4] : 3.8632
    • Ionizing Radiation, Human Health (Kbq Of U235 Equiv.) Manufacturing [A1-a3] : 62.013
    • Ionizing Radiation, Human Health (Kbq Of U235 Equiv.) Operational Energy Use [B6] : 110.51
    • Ionizing Radiation, Human Health (Kbq Of U235 Equiv.) Benefits/Loads Beyond System Boundaries [D] : -175.89
    • Materials For Recycling (Kg) End Of Life [C1-c4] : 0.8325
    • Net Use Of Fresh Water (M3) Benefits/Loads Beyond System Boundaries [D] : -0.3688
    • Non-hazardous Waste Disposed Of (Kg) Manufacturing [A1-a3] : 12.889
    • Non-hazardous Waste Disposed Of (Kg) Installation [A5] : 1.5373
    • Non-hazardous Waste Disposed Of (Kg) Operational Energy Use [B6] : 10.693
    • Non-hazardous Waste Disposed Of (Kg) Benefits/Loads Beyond System Boundaries [D] : -27.708
    • Total Use Of Non-renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Total Life Cycle : 16.218
    • Total Use Of Non-renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Manufacturing [A1-a3] : 16.218
    • Total Use Of Primary Energy During The Life Cycle (Mj) Total Life Cycle : 2624.5234
    • Total Use Of Primary Energy During The Life Cycle (Mj) Manufacturing [A1-a3] : 216.08
    • Total Use Of Primary Energy During The Life Cycle (Mj) Distribution [A4] : 6.4407
    • Total Use Of Primary Energy During The Life Cycle (Mj) Installation [A5] : 5.2727
    • Total Use Of Primary Energy During The Life Cycle (Mj) Operational Energy Use [B6] : 2257.1
    • Total Use Of Primary Energy During The Life Cycle (Mj) End Of Life [C1-c4] : 139.63
    • Total Use Of Primary Energy During The Life Cycle (Mj) Benefits/Loads Beyond System Boundaries [D] : -628.01
    • Total Use Of Renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Manufacturing [A1-a3] : 7.3032
    • Total Use Of Renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Operational Energy Use [B6] : 363.6
    • Total Use Of Renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) End Of Life [C1-c4] : 1.0178
    • Total Use Of Renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Benefits/Loads Beyond System Boundaries [D] : -9.0851
    • Use Of Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Manufacturing [A1-a3] : 16.218
    • Use Of Non-renewable Primary Energy, Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Total Life Cycle : 2236.0297
    • Use Of Non-renewable Primary Energy, Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Manufacturing [A1-a3] : 192.56
    • Use Of Non-renewable Primary Energy, Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Distribution [A4] : 6.4406
    • Use Of Non-renewable Primary Energy, Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Installation [A5] : 4.9191
    • Use Of Non-renewable Primary Energy, Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Operational Energy Use [B6] : 1893.5
    • Use Of Non-renewable Primary Energy, Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) End Of Life [C1-c4] : 138.61
    • Use Of Non-renewable Primary Energy, Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Benefits/Loads Beyond System Boundaries [D] : -618.9
    • Use Of Renewable Primary Energy Resources Used As Raw Materials (Mj) Total Life Cycle : 4.6209
    • Use Of Renewable Primary Energy Resources Used As Raw Materials (Mj) Manufacturing [A1-a3] : 4.6209
    • Use Of Renewable Primary Energy Resources Used As Raw Materials (Mj) Benefits/Loads Beyond System Boundaries [D] : -4.6741
    • Use Of Renewable Primary Energy, Excluding Renewable Primary Energy Resources Used As Raw Materials (Mj) Manufacturing [A1-a3] : 2.6822
    • Use Of Renewable Primary Energy, Excluding Renewable Primary Energy Resources Used As Raw Materials (Mj) Operational Energy Use [B6] : 363.6
    • Use Of Renewable Primary Energy, Excluding Renewable Primary Energy Resources Used As Raw Materials (Mj) End Of Life [C1-c4] : 1.0178
    • Use Of Renewable Primary Energy, Excluding Renewable Primary Energy Resources Used As Raw Materials (Mj) Benefits/Loads Beyond System Boundaries [D] : -4.411
    • Water Use (M3 Eq) Manufacturing [A1-a3] : 5.3303
    • Water Use (M3 Eq) Operational Energy Use [B6] : 2.6298
    • Water Use (M3 Eq) End Of Life [C1-c4] : 1.9598
    • Water Use (M3 Eq) Benefits/Loads Beyond System Boundaries [D] : -15.839
  • Environment Attributes Main
    • Ambient Air Temperature For Storage : -50-85 °C, -50-85 °C
    • Take Back : No
    • Halogene Performance : Halogen free plastic parts product
    • Recycled Metal Content At Cr Level : 0 %
    • China Rohs Regulation : X
    • Mercury Free : Yes
    • Carbon Footprint : 92.1423
    • Ambient Air Temperature For Operation : -25-70 °C-25-70 °C
    • Circularity Profile : ENVEOLI1704004EN
    • Climatic Withstand : IACS E10
    • Environmental Disclosure : ENVPEP1704004EN
    • Eu Rohs Directive : Compliant By Exemption
    • Halogen Content Performance : Halogen free plastic parts product
    • Ip Degree Of Protection : IP40 IEC 60529
    • Operating Altitude : 5000 m
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP1704004EN
    • Pep Verification Date : 2023-08-19
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed2-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Product Or Component Type : motor circuit breaker
    • Range Of Product : TeSys GV4
  • ETIM
    • ETIM 8 : EC000074
    • ETIM 9 : EC000074
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Specifications
    • Country of Origin : Brazil, France, United Kingdom, Poland
    • Depth : 165 mm