Motor circuit breaker, TeSys GV3, 3P, 9-13 A, thermal magnetic, EverLink terminals

Motor circuit breaker, TeSys GV3, 3P, 9-13 A, thermal magnetic, EverLink terminals

SQDGV3P13 GV3P13 785901492214
303.15 / EACH
  • Certifications: ABS, ATEX, BV, CCC, CSA, DNV-GL, EAC, IECEE CB Scheme, LROS (Lloyds Register Of Shipping), UL
  • Depth: 136 mm
  • Height: 132 mm
  • Line Rated Current: 13 A
  • Net Weight: 0.96 kg
  • Standard: CSA C22.2 No 60947-4-1, EN/IEC 60947-2, EN/IEC 60947-4-1, UL 60947-4-1
  • Storage Temperature: -40-80 °C
  • Trip Point: 182-182 A
  • Warranty Length: 18 mth
  • Width: 55 mm
TeSys GV motor circuit breaker, 3 poles (3P), 13A/690V, for 3-phase motor applications 5.5kW@400V. It provides a thermal-magnetic protection with a thermal setting range 9-13A, magnetic tripping at 14xIn, high breaking capacity Icu 100kA@400V. Connection by Everlink BTR screw terminals. Start-stop control by rotary knob guaranteed for 50 000 cycles AC-3. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX), Green Premium compliant (RoHS/REACh).
  • Product Description
  • Specifications
TeSys GV motor circuit breaker, 3 poles (3P), 13A/690V, for 3-phase motor applications 5.5kW@400V. It provides a thermal-magnetic protection with a thermal setting range 9-13A, magnetic tripping at 14xIn, high breaking capacity Icu 100kA@400V. Connection by Everlink BTR screw terminals. Start-stop control by rotary knob guaranteed for 50 000 cycles AC-3. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX), Green Premium compliant (RoHS/REACh).
  • Power Dissipation Per Pole : 8 W
  • Ambient Air Temperature For Storage : -40-80 °C
  • Electrical Durability : 50000 cycles AC-3 440 V In
  • Mechanical Durability : 50000 cycles
  • Warranty : 18 months
  • [Ue] Rated Operational Voltage : 690 V AC 50/60 Hz IEC 60947-2
  • Maximum Width : 55 mm
  • Magnetic Tripping Current : 182-182 A
  • Suitability For Isolation : yes IEC 60947-1
  • Device Short Name : GV3P
  • Utilisation Category : AC-3 IEC 60947-4-1 || category A IEC 60947-2
  • Tightening Torque : 5 N.m EverLink BTR screw connectors 25-25 mm² || 8 N.m EverLink BTR screw connectors 35-35 mm²
  • Ambient Air Temperature For Operation : -20-60 °C
  • Net Weight : 0.96 kg
  • [Uimp] Rated Impulse Withstand Voltage : 6 kV IEC 60947-2
  • [Ui] Rated Insulation Voltage : 690 V AC 50/60 Hz IEC 60947-2
  • Poles Description : 3P
  • Control Type : rotary knob
  • Ik Degree Of Protection : IK09
  • [Ics] Rated Service Short-Circuit Breaking Capacity : 100 % 230/240 V AC 50/60 Hz IEC 60947-2 || 100 % 440 V AC 50/60 Hz IEC 60947-2 || 100 % 400/415 V AC 50/60 Hz IEC 60947-2 || 50 % 500 V AC 50/60 Hz IEC 60947-2 || 50 % 690 V AC 50/60 Hz IEC 60947-2
  • Trip Unit Rating : 9-13 A
  • Ip Degree Of Protection : IP20 IEC 60529
  • Standards : EN/IEC 60947-2 || EN/IEC 60947-4-1 || CSA C22.2 No 60947-4-1 || UL 60947-4-1
  • Range Of Product : TeSys GV3
  • Maximum Height : 132 mm
  • Operating Altitude : 9842.52 ft (3000 m)
  • Phase Failure Sensitivity : yes IEC 60947-4-1
  • Network Type : AC
  • Fixing Mode : 35 mm symmetrical DIN rail clipped || panel screwed with 3 x M4 screws)
  • Maximum Operating Rate : 25 cyc/h
  • Product Certifications : IECEE CB Scheme || UL || CSA || CCC || EAC || ATEX || BV || LROS (Lloyds register of shipping) || DNV-GL || ABS
  • Device Application : motor
  • Range : TeSys
  • [Ith] Conventional Free Air Thermal Current : 13 A IEC 60947-4-1
  • Trip Unit Technology : thermal-magnetic
  • Compatibility Code : GV3P
  • Rated Duty : continuous IEC 60947-4-1
  • Fire Resistance : 960 °C IEC 60695-2-1
  • Motor Power Kw : 5.5-5.5 kW 400/415 V AC 50/60 Hz || 7.5-7.5 kW 500 V AC 50/60 Hz || 11-11 kW 690 V AC 50/60 Hz
  • Line Rated Current : 13 A
  • Breaking Capacity : 100 kA Icu 230/240 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2 || 50 kA Icu 440 V AC 50/60 Hz IEC 60947-2 || 6 kA Icu 690 V AC 50/60 Hz IEC 60947-2 || 12 kA Icu 500 V AC 50/60 Hz IEC 60947-2
  • Direct Connector : without
  • Product Name : TeSys GV3
  • Maximum Depth : 136 mm
  • Protective Treatment : TH
  • Product Or Component Type : circuit breaker
  • Network Frequency : 50/60 Hz IEC 60947-4-1
  • Operating Position : any position