Motor Management, TeSys T, motor controller, extension module, 4 inputs, for LTMR controller, 24 VDC

Motor Management, TeSys T, motor controller, extension module, 4 inputs, for LTMR controller, 24 VDC

SQDLTMEV40BD LTMEV40BD 785901502395
266.96 / EACH
  • Certifications: ABS, ATEX, BV, CCC, CSA, C-tick, DNV, EAC, GL, KERI, LROS (Lloyds Register Of Shipping), NOM, RINA, RMRoS, UL
  • Depth: 120.7 mm
  • Height: 61 mm
  • Net Weight: 0.21 kg
  • Standard: CSA C22.2 No 14, EN 60947-4-1, IACS E10, IEC 60947-4-1, UL 508
  • Storage Temperature: -40-80 °C
  • Width: 45 mm
TeSys T is a motor management system that provides full motor monitoring, control, and protection when used with short circuit protection and a contactor. TeSys T manages most critical processes while reducing downtime and increasing productivity. TeSys T is a flexible system that integrates seamlessly into your automation system through five major communication protocols. TeSys T predicts what will happen in the process, as it accurately monitors current, voltage, and power over a wide range. TeSys T has a number of components that increase the flexibility of the system. This expansion module adds functionalities to the TeSys T controller. It adds voltage mesurement between phases up to 690 V nominal and 4 additional inputs. Module has 4 discrete logic inputs. 24 VDC is used to power the module. Module has the following certifications: UL, CSA NOM, ATEX, BV, EAC, RINA, LROS, DNV, ABS, GL, KERI, RMRoS, C-Tick and CCC.
  • Product Description
  • Specifications
TeSys T is a motor management system that provides full motor monitoring, control, and protection when used with short circuit protection and a contactor. TeSys T manages most critical processes while reducing downtime and increasing productivity. TeSys T is a flexible system that integrates seamlessly into your automation system through five major communication protocols. TeSys T predicts what will happen in the process, as it accurately monitors current, voltage, and power over a wide range. TeSys T has a number of components that increase the flexibility of the system. This expansion module adds functionalities to the TeSys T controller. It adds voltage mesurement between phases up to 690 V nominal and 4 additional inputs. Module has 4 discrete logic inputs. 24 VDC is used to power the module. Module has the following certifications: UL, CSA NOM, ATEX, BV, EAC, RINA, LROS, DNV, ABS, GL, KERI, RMRoS, C-Tick and CCC.
  • Device Short Name : LTME
  • [Us] Rated Supply Voltage : 24 V DC
  • Net Weight : 0.21 kg
  • Ip Degree Of Protection : IP20
  • [Uimp] Rated Impulse Withstand Voltage : 6 kV current or voltage measurement circuit EN/IEC 60947-4-1 || 0.8 kV supply, inputs and outputs EN/IEC 60947-4-1
  • Range : TeSys
  • Pollution Degree : 3
  • Ambient Air Temperature For Storage : -40-80 °C
  • Fire Resistance : 650 °C EN/IEC 60695-2-12 || 960 °C UL 94
  • Tightening Torque : control circuit 0.5-0.6 N.m flat 3 mm
  • Electromagnetic Compatibility : electrostatic discharge, 3 8 kV air, 6 kV contact)EN/IEC 61000-4-2 || fast transients immunity test, level 3 2 kV)EN/IEC 61000-4-4 || fast transients immunity test, level 4 4 kV)EN/IEC 61000-4-4 || conducted RF disturbances 10 V)EN/IEC 61000-4-6 || surges 1 kV)EN/IEC 61000-4-5 || surges 1 kV)EN/IEC 61000-4-5 || surges 2 kV)EN/IEC 61000-4-5 || surges 2 kV)EN/IEC 61000-4-5 || surges 4 kV)EN/IEC 61000-4-5
  • Protective Treatment : 12 x 24 hour cycles EN/IEC 60068-2-30 || 48 h EN/IEC 60070-2-11 || TH EN/IEC 60068
  • Connections - Terminals : control circuit connector 1 0.25-2.5 mm² AWG 24...AWG 14)flexible with cable end || control circuit connector 1 0.2-2.5 mm² AWG 24...AWG 14)flexible without cable end || control circuit connector 1 0.25-2.5 mm² AWG 24...AWG 14)flexible without cable end || control circuit connector 1 0.2-2.5 mm² AWG 24...AWG 14)solid without cable end || control circuit connector 2 0.2-1 mm² AWG 24...AWG 14)flexible with cable end || control circuit connector 2 0.2-1.5 mm² AWG 24...AWG 14)flexible without cable end || control circuit connector 2 0.5-1.5 mm² AWG 24...AWG 14)flexible without cable end || control circuit connector 2 0.2-1 mm² AWG 24...AWG 14)solid without cable end
  • Input Current : 7 mA
  • Contacts Type And Composition : without
  • Overvoltage Category : III
  • Range Compatibility : TeSys T LTMR motor controller
  • Ambient Air Temperature For Operation : -20-60 °C
  • Product Or Component Type : extension module
  • Compatibility Code : LTME
  • Current State 1 Guaranteed : logic input < 15 V 2...15 mA 15 ms
  • Maximum Operating Frequency : 2 Hz
  • Product Name : TeSys T
  • Supply : via the controller
  • Metering Type : voltage U21, U32, U13, V1, V2, V3 || imbalance voltage || frequency || calculated active and reactive energy (+/- W.h, +/- VAR.h) || reactive power Q, Q1, Q2, Q3 || power factor || active power P, P1, P2, P3
  • Maximum Depth : 120.7 mm
  • Maximum Width : 45 mm
  • Device Application : equipment monitoring and control
  • Maximum Height : 61 mm
  • Standards : IEC 60947-4-1 || UL 508 || EN 60947-4-1 || IACS E10 || CSA C22.2 No 14
  • Logic Input Number : 4
  • Operating Altitude : <= 6561.68 ft (2000 m) without derating
  • Maximum Operating Rate : 1800 cyc/h
  • Current State 0 Guaranteed : logic input < 5 V <= 15 mA 5 ms
  • [Ui] Rated Insulation Voltage : 690 V EN/IEC 60947-1 || 690 V CSA C22.2 No 14 || 690 V UL 508
  • Connection Pitch : 5.08 mm
  • Measurement Accuracy : 1 % voltage 100...830 V) || 3 % power factor || 5 % active and reactive power
  • Mechanical Robustness : shocks half sine wave acceleration15 Gn for 11 ms EN/IEC 60068-2-27 || vibrations mounted on symmetrical rail1 Gn, 5...300 Hz EN/IEC 60068-2-6 || vibrations plate mounted4 Gn, 5...300 Hz EN/IEC 60068-2-6
  • Product Certifications : UL || NOM || ATEX || BV || CSA || EAC || RINA || LROS (Lloyds register of shipping) || DNV || ABS || GL || KERI || RMRoS || C-tick || CCC