  • Certifications: ABS, ATEX, BV, CCC, CSA, C-tick, DNV, EAC, GL, KERI, LROS (Lloyds Register Of Shipping), NOM, RINA, RMRoS, UL
  • Country of Origin: China
  • Current: 8-62.8 mA
  • Depth: 122.5 mm, 4.82 in
  • Height: 2.40 in, 61 mm
  • Operating Cycles: 1800 cyc/h
  • Standard: CSA C22.2 No 14, EN 60947-4-1, IACS E10, IEC 60947-4-1, UL 508
  • Warranty Length: 18 mth
  • Weight: 0.53 kg, 1.17 lb
  • Width: 3.58 in, 91 mm
TeSys T is a motor management system that provides full motor monitoring, control, and protection when used with short circuit protection and a contactor. It manages most critical processes while reducing downtime and increasing productivity as well as predicts what will happen in the process, as it accurately monitors current, voltage, and power over a wide range. This motor management system is also a flexible system that supports six communication protocols which are Modbus™, CANopen, DeviceNet™, Profibus™, Ethernet/IP, and Modbus/TCP. TeSys T motor management system consist of several components which include the LTMR controller, the expansion module, HMI and software along with several accessories. The LTMR controller is the main component of the system that manages the basic functions. This includes the measurement of the ground current, motor temperature, three phase current of the motor, the controller also includes logic inputs and outputs which is used in fault management. The expansion module is directly connected to the controller and provides additional inputs as well as measure the voltage between the phases which allow the controller the monitor additional functions. TeSys T is highly reliable and has a very long product life thanks to a state-of-the-art component selection, to the all in one design and to the advanced electronic protection. TeSys T can be integrated in many different types of harsh environment such as dusty atmospheres, marine applications, high vibration applications and corrosive atmospheres and is used in Metal/Mining/Mineral, Oil & Gas, Water Wastewater. This is a TeSys T LTMR controller that measure current range of 5-100A with a supply voltage of 100-240 Vac and uses EtherNet/Modbus TCP/IP as the communication protocol. This controller measures temperature, phase current, imbalance current, average current and earth-fault current. The dimensions of this device are 61 mm (H) X 91 mm (W) X 122.5 mm (D) and it weighs 0.53 kg. Controller has the following certifications: UL, CSA NOM, ATEX, BV, EAC, RINA, LROS, DNV, ABS, GL, KERI, RMRoS, C-Tick and CCC.
  • Product Description
  • Specifications
TeSys T is a motor management system that provides full motor monitoring, control, and protection when used with short circuit protection and a contactor. It manages most critical processes while reducing downtime and increasing productivity as well as predicts what will happen in the process, as it accurately monitors current, voltage, and power over a wide range. This motor management system is also a flexible system that supports six communication protocols which are Modbus™, CANopen, DeviceNet™, Profibus™, Ethernet/IP, and Modbus/TCP. TeSys T motor management system consist of several components which include the LTMR controller, the expansion module, HMI and software along with several accessories. The LTMR controller is the main component of the system that manages the basic functions. This includes the measurement of the ground current, motor temperature, three phase current of the motor, the controller also includes logic inputs and outputs which is used in fault management. The expansion module is directly connected to the controller and provides additional inputs as well as measure the voltage between the phases which allow the controller the monitor additional functions. TeSys T is highly reliable and has a very long product life thanks to a state-of-the-art component selection, to the all in one design and to the advanced electronic protection. TeSys T can be integrated in many different types of harsh environment such as dusty atmospheres, marine applications, high vibration applications and corrosive atmospheres and is used in Metal/Mining/Mineral, Oil & Gas, Water Wastewater. This is a TeSys T LTMR controller that measure current range of 5-100A with a supply voltage of 100-240 Vac and uses EtherNet/Modbus TCP/IP as the communication protocol. This controller measures temperature, phase current, imbalance current, average current and earth-fault current. The dimensions of this device are 61 mm (H) X 91 mm (W) X 122.5 mm (D) and it weighs 0.53 kg. Controller has the following certifications: UL, CSA NOM, ATEX, BV, EAC, RINA, LROS, DNV, ABS, GL, KERI, RMRoS, C-Tick and CCC.
  • Offer Sustainability
    • Mercury Free : Yes
    • Pvc Free : Yes
    • EU RoHs Directive : Compliant
    • WEEE : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Green Premium Status : Green Premium product
    • Halogen Content Performance : Halogen free plastic parts product
  • Ordering And Shipping Details
    • Country Of Origin : CN
    • GTIN : 00785901633815
    • Returnability : Yes
    • Discount Schedule : I12
    • Nbr. Of Units In Pkg. : 1
    • Category : 22338 - SOLID STATE OVERLOAD RELAYS
  • Complementary
    • Depth : 4.82 in (122.5 mm)
    • Height : 2.40 in (61 mm)
    • Overvoltage Category : III
    • Product Weight : 1.17 lb(US) (0.53 kg)
    • Permissible Power : 480 VA AC-15), Ie = 2 A, 500000 cycles output) || 30 W DC-13), Ie = 1.25 A, 500000 cycles output)
    • Web Services : Web server
    • Connection Pitch : 0.20 in (5.08 mm)
    • Metering Type : Phase current I1, I2, I3 RMS || Temperature || Earth-fault current || Average current Iavg || Imbalance current
    • Current State 0 Guaranteed : Logic input 0...40 V <= 15 mA 25 ms
    • Ui Rated Insulation Voltage : 690 V EN/IEC 60947-1 || 690 V CSA C22.2 No 14 || 690 V UL 508
    • Tightening Torque : Control circuit 4.43…5.31 lbf.in (0.5…0.6 N.m) flat 0.12 in (3 mm)
    • Width : 3.58 in (91 mm)
    • Compatibility Code : LTMR
    • Contacts Type And Composition : 1 NO + 1 NC fault signal || 3 NO
    • Uimp Rated Imp Wstd Voltage : 4 kV supply, inputs and outputs EN/IEC 60947-4-1 || 6 kV current or voltage measurement circuit EN/IEC 60947-4-1 || 0.8 kV communication circuit EN/IEC 60947-4-1
    • Short-Circuit Withstand : 100 kA EN/IEC 60947-4-1
    • Ntw And Machine Diagnosis Type : Waiting time after overload tripping || Motor control command recording || Trip context information || Phase fault and earth fault trip counters || Starting current and time || Trip history information || Fault recording || Event recording || Remaining operating time before overload tripping || Running hours counter/operating time
    • Protection Type : Reverse polarity protection || Overload || Phase unbalance || Overload (long time) || Thermal protection || Power factor variation || Thermal overload protection || Locked rotor || Earth-leakage protection || Load fluctuation || Phase failure
    • Measurement Accuracy : 5...15 % earth fault current internal measurement || 1 % voltage 100...830 V) || 3 % power factor || 5 % earth fault current external measurement || +/- 30 min/year internal clock || 0,02 Temperature || 5 % active and reactive power || 0,02 current
    • Load Current : 5 A 250 V AC logic output || 5 A 30 V DC logic output
    • Pollution Degree : 3
    • Maximum Output Switching Frequency : 2 Hz
    • Connections - Terminals : Control circuit connector 1 0.00…0.00 in² (0.25…2.5 mm²) AWG 24...AWG 14)flexible with cable end || Control circuit connector 1 0.00…0.00 in² (0.2…2.5 mm²) AWG 24...AWG 14)flexible without cable end || Control circuit connector 1 0.00…0.00 in² (0.25…2.5 mm²) AWG 24...AWG 14)flexible without cable end || Control circuit connector 1 0.00…0.00 in² (0.2…2.5 mm²) AWG 24...AWG 14)solid without cable end || Control circuit connector 2 0.00…0.00 in² (0.2…1 mm²) AWG 24...AWG 14)flexible with cable end || Control circuit connector 2 0.00…0.00 in² (0.2…1.5 mm²) AWG 24...AWG 14)flexible without cable end || Control circuit connector 2 0.00…0.00 in² (0.5…1.5 mm²) AWG 24...AWG 14)flexible without cable end || Control circuit connector 2 0.00…0.00 in² (0.2…1 mm²) AWG 24...AWG 14)solid without cable end
    • Logic Input Number : 6
    • Operating Rate : 1800 cyc/h
    • Associated Fuse Rating : 4 A gG output || 0.5 A gG control circuit
    • Electromagnetic Compatibility : Electrostatic discharge, 3 8 kV air, 6 kV contact)EN/IEC 61000-4-2) || Radiated RF fields, 3 10 V/m)EN/IEC 61000-4-3) || Fast transients immunity test, level 3 2 kV)EN/IEC 61000-4-4) || Fast transients immunity test, level 4 4 kV)EN/IEC 61000-4-4) || Voltage dips and interruptions immunity test 70 %, 500 ms)EN/IEC 61000-4-11) || Conducted RF disturbances 10 V)EN/IEC 61000-4-6) || Surges 0.5 kV)EN/IEC 61000-4-5) || Surges 1 kV)EN/IEC 61000-4-5) || Surges 1 kV)EN/IEC 61000-4-5) || Surges 2 kV)EN/IEC 61000-4-5) || Surges 2 kV)EN/IEC 61000-4-5) || Surges 4 kV)EN/IEC 61000-4-5) || Surges 2 kV)EN/IEC 61000-4-5)
    • Input Current : 3.1 mA 100 V || 7.5 mA 240 V
    • Current State 1 Guaranteed : Logic input 79...264 V >= 2 mA 25 ms
  • Contractual Warranty
    • Warranty : 18 months
  • Main
    • Bus Type : Ethernet IEEE 802.3 0...159 10...100 Mbit/s, RJ45 2 shielded twisted pairs
    • Device Application : Equipment monitoring and control
    • Communication Port Protocol : Modbus TCP/EtherNet/IP
    • Product Or Component Type : Motor controller
    • Device Short Name : LTMR
    • Range : TeSys
    • Measurement Current : 5…100 A
    • Current Consumption : 8...62.8 mA
    • [Us] Rated Supply Voltage : 100...240 V AC 50/60 Hz
    • Supply Voltage Limits : 93.5…264 V AC
    • Product Name : TeSys T
  • Environment
    • Mechanical Robustness : Vibrations mounted on symmetrical rail1 Gn, 5...300 Hz EN/IEC 60068-2-6 || Vibrations plate mounted4 Gn, 5...300 Hz EN/IEC 60068-2-6 || Shocks half sine wave acceleration15 Gn for 11 ms EN/IEC 60068-2-27
    • Fire Resistance : 1202 °F (650 °C) EN/IEC 60695-2-12 || 1760 °F (960 °C) UL 94
    • Operating Altitude : <= 6561.68 ft (2000 m) without derating
    • IP Degree Of Protection : IP20
    • Protective Treatment : 12 x 24 hour cycles EN/IEC 60068-2-30 || 48 h EN/IEC 60070-2-11 || TH EN/IEC 60068
    • Ambient Air Temp For Op : -4…140 °F (-20…60 °C)
    • Product Certifications : C-tick || ABS || UL || DNV || NOM || RINA || RMRoS || BV || LROS (Lloyds register of shipping) || KERI || EAC || CCC || CSA || ATEX || GL
    • Ambient Air Temp For Storage : -40…176 °F (-40…80 °C)
    • Standards : CSA C22.2 No 14 || EN 60947-4-1 || IACS E10 || UL 508 || IEC 60947-4-1