  • Certifications: ABS, ATEX, BV, CCC, CSA, C-tick, DNV, EAC, GL, KERI, LROS (Lloyds Register Of Shipping), NOM, RINA, RMRoS, UL
  • Country of Origin: China
  • Current: 8-62.8 mA
  • Depth: 122.5 mm, 4.82 in
  • Height: 2.40 in, 61 mm
  • Operating Cycles: 1800 cyc/h
  • Standard: CSA C22.2 No 14, EN 60947-4-1, IACS E10, IEC 60947-4-1, UL 508
  • Warranty Length: 18 mth
  • Weight: 0.53 kg, 1.17 lb
  • Width: 3.58 in, 91 mm
TeSys T is a motor management system that provides full motor monitoring, control, and protection when used with short circuit protection and a contactor. It manages most critical processes while reducing downtime and increasing productivity as well as predicts what will happen in the process, as it accurately monitors current, voltage, and power over a wide range. This motor management system is also a flexible system that supports six communication protocols which are Modbus™, CANopen, DeviceNet™, Profibus™, Ethernet/IP, and Modbus/TCP. TeSys T motor management system consist of several components which include the LTMR controller, the expansion module, HMI and software along with several accessories. The LTMR controller is the main component of the system that manages the basic functions. This includes the measurement of the ground current, motor temperature, three phase current of the motor, the controller also includes logic inputs and outputs which is used in fault management. The expansion module is directly connected to the controller and provides additional inputs as well as measure the voltage between the phases which allow the controller the monitor additional functions. TeSys T is highly reliable and has a very long product life thanks to a state-of-the-art component selection, to the all in one design and to the advanced electronic protection. TeSys T can be integrated in many different types of harsh environment such as dusty atmospheres, marine applications, high vibration applications and corrosive atmospheres and is used in Metal/Mining/Mineral, Oil & Gas, Water Wastewater. This is a TeSys T LTMR controller that measure current range of 0.4-8A with a supply voltage of 100-240 Vac and uses EtherNet/Modbus TCP/IP as the communication protocol. This controller measures temperature, phase current, imbalance current, average current and earth-fault current. The dimensions of this device are 61 mm (H) X 91 mm (W) X 122.5 mm (D) and it weighs 0.53 kg. Controller has the following certifications: UL, CSA NOM, ATEX, BV, EAC, RINA, LROS, DNV, ABS, GL, KERI, RMRoS, C-Tick and CCC.
  • Product Description
  • Specifications
TeSys T is a motor management system that provides full motor monitoring, control, and protection when used with short circuit protection and a contactor. It manages most critical processes while reducing downtime and increasing productivity as well as predicts what will happen in the process, as it accurately monitors current, voltage, and power over a wide range. This motor management system is also a flexible system that supports six communication protocols which are Modbus™, CANopen, DeviceNet™, Profibus™, Ethernet/IP, and Modbus/TCP. TeSys T motor management system consist of several components which include the LTMR controller, the expansion module, HMI and software along with several accessories. The LTMR controller is the main component of the system that manages the basic functions. This includes the measurement of the ground current, motor temperature, three phase current of the motor, the controller also includes logic inputs and outputs which is used in fault management. The expansion module is directly connected to the controller and provides additional inputs as well as measure the voltage between the phases which allow the controller the monitor additional functions. TeSys T is highly reliable and has a very long product life thanks to a state-of-the-art component selection, to the all in one design and to the advanced electronic protection. TeSys T can be integrated in many different types of harsh environment such as dusty atmospheres, marine applications, high vibration applications and corrosive atmospheres and is used in Metal/Mining/Mineral, Oil & Gas, Water Wastewater. This is a TeSys T LTMR controller that measure current range of 0.4-8A with a supply voltage of 100-240 Vac and uses EtherNet/Modbus TCP/IP as the communication protocol. This controller measures temperature, phase current, imbalance current, average current and earth-fault current. The dimensions of this device are 61 mm (H) X 91 mm (W) X 122.5 mm (D) and it weighs 0.53 kg. Controller has the following certifications: UL, CSA NOM, ATEX, BV, EAC, RINA, LROS, DNV, ABS, GL, KERI, RMRoS, C-Tick and CCC.
  • Main
    • Device Application : Equipment monitoring and control
    • Current Consumption : 8...62.8 mA
    • Device Short Name : LTMR
    • Product Name : TeSys T
    • Bus Type : Ethernet IEEE 802.3 0...159 10...100 Mbit/s, RJ45 2 shielded twisted pairs
    • Measurement Current : 0.4…8 A
    • Product Or Component Type : Motor controller
    • [Us] Rated Supply Voltage : 100...240 V AC 50/60 Hz
    • Range : TeSys
    • Communication Port Protocol : Modbus TCP/EtherNet/IP
    • Supply Voltage Limits : 93.5…264 V AC
  • Ordering And Shipping Details
    • Returnability : Yes
    • GTIN : 00785901620198
    • Discount Schedule : I12
    • Country Of Origin : CN
    • Category : 22338 - SOLID STATE OVERLOAD RELAYS
    • Nbr. Of Units In Pkg. : 1
  • Contractual Warranty
    • Warranty : 18 months
  • Offer Sustainability
    • Pvc Free : Yes
    • Green Premium Status : Green Premium product
    • EU RoHs Directive : Compliant
    • WEEE : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Halogen Content Performance : Halogen free plastic parts product
    • Mercury Free : Yes
  • Complementary
    • Short-Circuit Withstand : 100 kA EN/IEC 60947-4-1
    • Current State 0 Guaranteed : Logic input 0...40 V <= 15 mA 25 ms
    • Uimp Rated Imp Wstd Voltage : 4 kV supply, inputs and outputs EN/IEC 60947-4-1 || 6 kV current or voltage measurement circuit EN/IEC 60947-4-1 || 0.8 kV communication circuit EN/IEC 60947-4-1
    • Width : 3.58 in (91 mm)
    • Connections - Terminals : Control circuit connector 1 0.00…0.00 in² (0.25…2.5 mm²) AWG 24...AWG 14)flexible with cable end || Control circuit connector 1 0.00…0.00 in² (0.2…2.5 mm²) AWG 24...AWG 14)flexible without cable end || Control circuit connector 1 0.00…0.00 in² (0.25…2.5 mm²) AWG 24...AWG 14)flexible without cable end || Control circuit connector 1 0.00…0.00 in² (0.2…2.5 mm²) AWG 24...AWG 14)solid without cable end || Control circuit connector 2 0.00…0.00 in² (0.2…1 mm²) AWG 24...AWG 14)flexible with cable end || Control circuit connector 2 0.00…0.00 in² (0.2…1.5 mm²) AWG 24...AWG 14)flexible without cable end || Control circuit connector 2 0.00…0.00 in² (0.5…1.5 mm²) AWG 24...AWG 14)flexible without cable end || Control circuit connector 2 0.00…0.00 in² (0.2…1 mm²) AWG 24...AWG 14)solid without cable end
    • Web Services : Web server
    • Associated Fuse Rating : 4 A gG output || 0.5 A gG control circuit
    • Pollution Degree : 3
    • Protection Type : Thermal overload protection || Overload || Thermal protection || Locked rotor || Phase failure || Phase unbalance || Load fluctuation || Reverse polarity protection || Overload (long time) || Earth-leakage protection || Power factor variation
    • Measurement Accuracy : 5...15 % earth fault current internal measurement || 1 % voltage 100...830 V) || 3 % power factor || 5 % earth fault current external measurement || +/- 30 min/year internal clock || 0,02 Temperature || 1 % current || 5 % active and reactive power
    • Contacts Type And Composition : 1 NO + 1 NC fault signal || 3 NO
    • Ntw And Machine Diagnosis Type : Trip context information || Phase fault and earth fault trip counters || Trip history information || Event recording || Remaining operating time before overload tripping || Starting current and time || Fault recording || Waiting time after overload tripping || Running hours counter/operating time || Motor control command recording
    • Depth : 4.82 in (122.5 mm)
    • Ui Rated Insulation Voltage : 690 V EN/IEC 60947-1 || 690 V CSA C22.2 No 14 || 690 V UL 508
    • Compatibility Code : LTMR
    • Electromagnetic Compatibility : Electrostatic discharge, 3 8 kV air, 6 kV contact)EN/IEC 61000-4-2) || Radiated RF fields, 3 10 V/m)EN/IEC 61000-4-3) || Fast transients immunity test, level 3 2 kV)EN/IEC 61000-4-4) || Fast transients immunity test, level 4 4 kV)EN/IEC 61000-4-4) || Voltage dips and interruptions immunity test 70 %, 500 ms)EN/IEC 61000-4-11) || Conducted RF disturbances 10 V)EN/IEC 61000-4-6) || Surges 0.5 kV)EN/IEC 61000-4-5) || Surges 1 kV)EN/IEC 61000-4-5) || Surges 1 kV)EN/IEC 61000-4-5) || Surges 2 kV)EN/IEC 61000-4-5) || Surges 2 kV)EN/IEC 61000-4-5) || Surges 4 kV)EN/IEC 61000-4-5) || Surges 2 kV)EN/IEC 61000-4-5)
    • Height : 2.40 in (61 mm)
    • Permissible Power : 480 VA AC-15), Ie = 2 A, 500000 cycles output) || 30 W DC-13), Ie = 1.25 A, 500000 cycles output)
    • Maximum Output Switching Frequency : 2 Hz
    • Tightening Torque : Control circuit 4.43…5.31 lbf.in (0.5…0.6 N.m) flat 0.12 in (3 mm)
    • Product Weight : 1.17 lb(US) (0.53 kg)
    • Connection Pitch : 0.20 in (5.08 mm)
    • Load Current : 5 A 250 V AC logic output || 5 A 30 V DC logic output
    • Metering Type : Earth-fault current || Imbalance current || Temperature || Average current Iavg || Phase current I1, I2, I3 RMS
    • Operating Rate : 1800 cyc/h
    • Overvoltage Category : III
    • Input Current : 3.1 mA 100 V || 7.5 mA 240 V
    • Logic Input Number : 6
    • Current State 1 Guaranteed : Logic input 79...264 V >= 2 mA 25 ms
  • Environment
    • Mechanical Robustness : Vibrations mounted on symmetrical rail1 Gn, 5...300 Hz EN/IEC 60068-2-6 || Vibrations plate mounted4 Gn, 5...300 Hz EN/IEC 60068-2-6 || Shocks half sine wave acceleration15 Gn for 11 ms EN/IEC 60068-2-27
    • Protective Treatment : 12 x 24 hour cycles EN/IEC 60068-2-30 || 48 h EN/IEC 60070-2-11 || TH EN/IEC 60068
    • Ambient Air Temp For Op : -4…140 °F (-20…60 °C)
    • Fire Resistance : 1202 °F (650 °C) EN/IEC 60695-2-12 || 1760 °F (960 °C) UL 94
    • IP Degree Of Protection : IP20
    • Ambient Air Temp For Storage : -40…176 °F (-40…80 °C)
    • Product Certifications : NOM || LROS (Lloyds register of shipping) || RMRoS || CSA || BV || KERI || GL || ABS || ATEX || RINA || UL || C-tick || EAC || CCC || DNV
    • Operating Altitude : <= 6561.68 ft (2000 m) without derating
    • Standards : EN 60947-4-1 || IEC 60947-4-1 || CSA C22.2 No 14 || IACS E10 || UL 508