  • Certifications: ABS, ATEX, BV, CCC, CSA, C-tick, DNV, EAC, GL, KERI, LROS (Lloyds Register Of Shipping), NOM, RINA, RMRoS, UL
  • Current: 8-62.8 mA
  • Depth: 122.5 mm
  • Height: 61 mm
  • Net Weight: 0.53 kg
  • Standard: CSA C22.2 No 14, EN 60947-4-1, IACS E10, IEC 60947-4-1, UL 508
  • Storage Temperature: -40-80 °C
  • Warranty Length: 18 mth
  • Width: 91 mm
TeSys T is a motor management system that provides full motor monitoring, control, and protection when used with short circuit protection and a contactor. TeSys T manages most critical processes while reducing downtime and increasing productivity. TeSys T is a flexible system that integrates seamlessly into your automation system through five major communication protocols. TeSys T predicts what will happen in the process, as it accurately monitors current, voltage, and power over a wide range. This controller is the central component in the motor management system. The module manages the basic functions of the motor management system. It manages the measurement of 3 phase current via integral current transformers from 0.4 to 100 A or up to 810 A by external current transformers. It also measures ground current with internal or external ground sensors, motor temperature and the inputs and outputs for the various motor control modes, detected fault management and other functions. DeviceNet protocol is used by this controller. This module has 6 discrete logic inputs, 3 relay logic outputs and a relay output for detected fault signaling overload relay. The current range of this controller is 5 to 100 amperes. 120 to 240 VAC is used to power this controller. Controller has the following certifications: UL, CSA NOM, ATEX, BV, EAC, RINA, LROS, DNV, ABS, GL, KERI, RMRoS, C-Tick and CCC.
  • Product Description
  • Specifications
TeSys T is a motor management system that provides full motor monitoring, control, and protection when used with short circuit protection and a contactor. TeSys T manages most critical processes while reducing downtime and increasing productivity. TeSys T is a flexible system that integrates seamlessly into your automation system through five major communication protocols. TeSys T predicts what will happen in the process, as it accurately monitors current, voltage, and power over a wide range. This controller is the central component in the motor management system. The module manages the basic functions of the motor management system. It manages the measurement of 3 phase current via integral current transformers from 0.4 to 100 A or up to 810 A by external current transformers. It also measures ground current with internal or external ground sensors, motor temperature and the inputs and outputs for the various motor control modes, detected fault management and other functions. DeviceNet protocol is used by this controller. This module has 6 discrete logic inputs, 3 relay logic outputs and a relay output for detected fault signaling overload relay. The current range of this controller is 5 to 100 amperes. 120 to 240 VAC is used to power this controller. Controller has the following certifications: UL, CSA NOM, ATEX, BV, EAC, RINA, LROS, DNV, ABS, GL, KERI, RMRoS, C-Tick and CCC.
  • Maximum Operating Frequency : 2 Hz
  • Device Short Name : LTMR
  • Mechanical Robustness : vibrations mounted on symmetrical rail1 Gn, 5...300 Hz EN/IEC 60068-2-6 || vibrations plate mounted4 Gn, 5...300 Hz EN/IEC 60068-2-6 || shocks half sine wave acceleration15 Gn for 11 ms EN/IEC 60068-2-27
  • Compatibility Code : LTMR
  • Network And Machine Diagnosis Type : motor control command recording || trip history information || running hours counter/operating time || phase fault and earth fault trip counters || remaining operating time before overload tripping || fault recording || trip context information || event recording || starting current and time || waiting time after overload tripping
  • [Uimp] Rated Impulse Withstand Voltage : 4 kV supply, inputs and outputs EN/IEC 60947-4-1 || 6 kV current or voltage measurement circuit EN/IEC 60947-4-1 || 0.8 kV communication circuit EN/IEC 60947-4-1
  • Current Consumption : 8...62.8 mA
  • Standards : EN 60947-4-1 || UL 508 || IEC 60947-4-1 || CSA C22.2 No 14 || IACS E10
  • Metering Type : imbalance current || temperature || average current Iavg || earth-fault current || phase current I1, I2, I3 RMS
  • Maximum Width : 91 mm
  • Load Current : 5 A 250 V AC logic output || 5 A 30 V DC logic output
  • Supply Voltage Limits : 93.5-264 V AC
  • Current State 1 Guaranteed : logic input 79...264 V >= 2 mA 25 ms
  • Range : TeSys
  • Device Application : equipment monitoring and control
  • Bus Type : DeviceNet ISO 1198 1...64 125...500 kbit/s, terminal block 4 twisted shielded pairs cable
  • Ambient Air Temperature For Storage : -40-80 °C
  • Contacts Type And Composition : 1 NO + 1 NC fault signal || 3 NO
  • Protective Treatment : 12 x 24 hour cycles EN/IEC 60068-2-30 || 48 h EN/IEC 60070-2-11 || TH EN/IEC 60068
  • Net Weight : 0.53 kg
  • [Ui] Rated Insulation Voltage : 690 V EN/IEC 60947-1 || 690 V CSA C22.2 No 14 || 690 V UL 508
  • Associated Fuse Rating : 4 A gG output || 0.5 A gG control circuit
  • Warranty : 18 months
  • Maximum Height : 61 mm
  • Ambient Air Temperature For Operation : -20-60 °C
  • Fire Resistance : 650 °C EN/IEC 60695-2-12 || 960 °C UL 94
  • Operating Altitude : <= 6561.68 ft (2000 m) without derating
  • Product Or Component Type : motor controller
  • Maximum Operating Rate : 1800 cyc/h
  • Connection Pitch : 5.08 mm
  • Measurement Current : 5-100 A
  • Connections - Terminals : control circuit connector 1 0.25-2.5 mm² AWG 24...AWG 14)flexible with cable end || control circuit connector 1 0.2-2.5 mm² AWG 24...AWG 14)flexible without cable end || control circuit connector 1 0.25-2.5 mm² AWG 24...AWG 14)flexible without cable end || control circuit connector 1 0.2-2.5 mm² AWG 24...AWG 14)solid without cable end || control circuit connector 2 0.2-1 mm² AWG 24...AWG 14)flexible with cable end || control circuit connector 2 0.2-1.5 mm² AWG 24...AWG 14)flexible without cable end || control circuit connector 2 0.5-1.5 mm² AWG 24...AWG 14)flexible without cable end || control circuit connector 2 0.2-1 mm² AWG 24...AWG 14)solid without cable end
  • Permissible Power : 480 VA AC-15), Ie = 2 A, 500000 cycles output) || 30 W DC-13), Ie = 1.25 A, 500000 cycles output)
  • Measurement Accuracy : 5...15 % earth fault current internal measurement || 1 % voltage 100...830 V) || 3 % power factor || 5 % earth fault current external measurement || +/- 30 min/year internal clock || 0,02 Temperature || 5 % active and reactive power || 0,02 current
  • Short-Circuit Withstand : 100 kA EN/IEC 60947-4-1
  • Input Current : 3.1 mA 100 V || 7.5 mA 240 V
  • Ip Degree Of Protection : IP20
  • Product Name : TeSys T
  • Current State 0 Guaranteed : logic input 0...40 V <= 15 mA 25 ms
  • Pollution Degree : 3
  • Logic Input Number : 6
  • Electromagnetic Compatibility : electrostatic discharge, 3 8 kV air, 6 kV contact)EN/IEC 61000-4-2 || surges 2 kV)EN/IEC 61000-4-5 || surges 2 kV)EN/IEC 61000-4-5 || surges 4 kV)EN/IEC 61000-4-5 || surges 2 kV)EN/IEC 61000-4-5 || radiated RF fields, 3 10 V/m)EN/IEC 61000-4-3 || fast transients immunity test, level 3 2 kV)EN/IEC 61000-4-4 || fast transients immunity test, level 4 4 kV)EN/IEC 61000-4-4 || voltage dips and interruptions immunity test 70 %, 500 ms)EN/IEC 61000-4-11 || conducted RF disturbances 10 V)EN/IEC 61000-4-6 || surges 0.5 kV)EN/IEC 61000-4-5 || surges 1 kV)EN/IEC 61000-4-5 || surges 1 kV)EN/IEC 61000-4-5
  • Maximum Depth : 122.5 mm
  • Tightening Torque : control circuit 0.5-0.6 N.m flat 3 mm
  • Web Services : web server
  • [Us] Rated Supply Voltage : 100...240 V AC 50/60 Hz
  • Protection Type : phase failure || overload (long time) || load fluctuation || thermal overload protection || power factor variation || overload || locked rotor || thermal protection || earth-leakage protection || phase unbalance || reverse polarity protection
  • Overvoltage Category : III
  • Product Certifications : CSA || DNV || LROS (Lloyds register of shipping) || RINA || EAC || GL || UL || ATEX || BV || CCC || RMRoS || KERI || ABS || NOM || C-tick
  • Communication Port Protocol : DeviceNet