Motor Management, TeSys T, motor controller, DeviceNet, 6 logic inputs, 3 relay logic outputs, 0.4 to 8A, 100 to 240 VAC

Motor Management, TeSys T, motor controller, DeviceNet, 6 logic inputs, 3 relay logic outputs, 0.4 to 8A, 100 to 240 VAC

SQDLTMR08DFM LTMR08DFM 785901502364
667.40 / EACH
  • Certifications: ABS, ATEX, BV, CCC, CSA, C-tick, DNV, EAC, GL, KERI, LROS (Lloyds Register Of Shipping), NOM, RINA, RMRoS, UL
  • Country of Origin: China
  • Current: 8-62.8 mA
  • Depth: 122.5 mm, 4.82 in
  • Height: 2.40 in, 61 mm
  • Operating Cycles: 1800 cyc/h
  • Standard: CSA C22.2 No 14, EN 60947-4-1, IACS E10, IEC 60947-4-1, UL 508
  • Warranty Length: 18 mth
  • Weight: 0.53 kg, 1.17 lb
  • Width: 3.58 in, 91 mm
TeSys T is a motor management system that provides full motor monitoring, control, and protection when used with short circuit protection and a contactor. TeSys T manages most critical processes while reducing downtime and increasing productivity. TeSys T is a flexible system that integrates seamlessly into your automation system through five major communication protocols. TeSys T predicts what will happen in the process, as it accurately monitors current, voltage, and power over a wide range. This controller is the central component in the motor management system. The module manages the basic functions of the motor management system. It manages the measurement of 3 phase current via integral current transformers from 0.4 to 100 A or up to 810 A by external current transformers. It also measures ground current with internal or external ground sensors, motor temperature and the inputs and outputs for the various motor control modes, detected fault management and other functions. DeviceNet protocol is used by this controller. This module has 6 discrete logic inputs, 3 relay logic outputs and a relay output for detected fault signaling overload relay. The current range of this controller is 0.4 to 8 amperes. 120 to 240 VAC is used to power this controller. Controller has the following certifications: UL, CSA NOM, ATEX, BV, EAC, RINA, LROS, DNV, ABS, GL, KERI, RMRoS, C-Tick and CCC.
  • Product Description
  • Specifications
TeSys T is a motor management system that provides full motor monitoring, control, and protection when used with short circuit protection and a contactor. TeSys T manages most critical processes while reducing downtime and increasing productivity. TeSys T is a flexible system that integrates seamlessly into your automation system through five major communication protocols. TeSys T predicts what will happen in the process, as it accurately monitors current, voltage, and power over a wide range. This controller is the central component in the motor management system. The module manages the basic functions of the motor management system. It manages the measurement of 3 phase current via integral current transformers from 0.4 to 100 A or up to 810 A by external current transformers. It also measures ground current with internal or external ground sensors, motor temperature and the inputs and outputs for the various motor control modes, detected fault management and other functions. DeviceNet protocol is used by this controller. This module has 6 discrete logic inputs, 3 relay logic outputs and a relay output for detected fault signaling overload relay. The current range of this controller is 0.4 to 8 amperes. 120 to 240 VAC is used to power this controller. Controller has the following certifications: UL, CSA NOM, ATEX, BV, EAC, RINA, LROS, DNV, ABS, GL, KERI, RMRoS, C-Tick and CCC.
  • Environment
    • Standards : UL 508 || IACS E10 || CSA C22.2 No 14 || IEC 60947-4-1 || EN 60947-4-1
    • IP Degree Of Protection : IP20
    • Fire Resistance : 1202 °F (650 °C) EN/IEC 60695-2-12 || 1760 °F (960 °C) UL 94
    • Mechanical Robustness : Vibrations mounted on symmetrical rail1 Gn, 5...300 Hz EN/IEC 60068-2-6 || Vibrations plate mounted4 Gn, 5...300 Hz EN/IEC 60068-2-6 || Shocks half sine wave acceleration15 Gn for 11 ms EN/IEC 60068-2-27
    • Protective Treatment : 12 x 24 hour cycles EN/IEC 60068-2-30 || 48 h EN/IEC 60070-2-11 || TH EN/IEC 60068
    • Operating Altitude : <= 6561.68 ft (2000 m) without derating
    • Ambient Air Temp For Op : -4…140 °F (-20…60 °C)
    • Product Certifications : KERI || LROS (Lloyds register of shipping) || CSA || ATEX || UL || DNV || C-tick || RMRoS || CCC || RINA || ABS || EAC || GL || NOM || BV
    • Ambient Air Temp For Storage : -40…176 °F (-40…80 °C)
  • Contractual Warranty
    • Warranty : 18 months
  • Complementary
    • Measurement Accuracy : 5...15 % earth fault current internal measurement || 1 % voltage 100...830 V) || 3 % power factor || 5 % earth fault current external measurement || +/- 30 min/year internal clock || 0,02 Temperature || 1 % current || 5 % active and reactive power
    • Depth : 4.82 in (122.5 mm)
    • Compatibility Code : LTMR
    • Logic Input Number : 6
    • Ntw And Machine Diagnosis Type : Running hours counter/operating time || Starting current and time || Fault recording || Trip history information || Trip context information || Phase fault and earth fault trip counters || Motor control command recording || Event recording || Waiting time after overload tripping || Remaining operating time before overload tripping
    • Width : 3.58 in (91 mm)
    • Uimp Rated Imp Wstd Voltage : 4 kV supply, inputs and outputs EN/IEC 60947-4-1 || 6 kV current or voltage measurement circuit EN/IEC 60947-4-1 || 0.8 kV communication circuit EN/IEC 60947-4-1
    • Product Weight : 1.17 lb(US) (0.53 kg)
    • Tightening Torque : Control circuit 4.43…5.31 lbf.in (0.5…0.6 N.m) flat 0.12 in (3 mm)
    • Connection Pitch : 0.20 in (5.08 mm)
    • Connections - Terminals : Control circuit connector 1 0.00…0.00 in² (0.25…2.5 mm²) AWG 24...AWG 14)flexible with cable end || Control circuit connector 1 0.00…0.00 in² (0.2…2.5 mm²) AWG 24...AWG 14)flexible without cable end || Control circuit connector 1 0.00…0.00 in² (0.25…2.5 mm²) AWG 24...AWG 14)flexible without cable end || Control circuit connector 1 0.00…0.00 in² (0.2…2.5 mm²) AWG 24...AWG 14)solid without cable end || Control circuit connector 2 0.00…0.00 in² (0.2…1 mm²) AWG 24...AWG 14)flexible with cable end || Control circuit connector 2 0.00…0.00 in² (0.2…1.5 mm²) AWG 24...AWG 14)flexible without cable end || Control circuit connector 2 0.00…0.00 in² (0.5…1.5 mm²) AWG 24...AWG 14)flexible without cable end || Control circuit connector 2 0.00…0.00 in² (0.2…1 mm²) AWG 24...AWG 14)solid without cable end
    • Current State 1 Guaranteed : Logic input 79...264 V >= 2 mA 25 ms
    • Protection Type : Thermal overload protection || Phase failure || Overload || Load fluctuation || Power factor variation || Overload (long time) || Earth-leakage protection || Reverse polarity protection || Thermal protection || Phase unbalance || Locked rotor
    • Ui Rated Insulation Voltage : 690 V EN/IEC 60947-1 || 690 V CSA C22.2 No 14 || 690 V UL 508
    • Electromagnetic Compatibility : Electrostatic discharge, 3 8 kV air, 6 kV contact)EN/IEC 61000-4-2) || Radiated RF fields, 3 10 V/m)EN/IEC 61000-4-3) || Fast transients immunity test, level 3 2 kV)EN/IEC 61000-4-4) || Fast transients immunity test, level 4 4 kV)EN/IEC 61000-4-4) || Voltage dips and interruptions immunity test 70 %, 500 ms)EN/IEC 61000-4-11) || Conducted RF disturbances 10 V)EN/IEC 61000-4-6) || Surges 0.5 kV)EN/IEC 61000-4-5) || Surges 1 kV)EN/IEC 61000-4-5) || Surges 1 kV)EN/IEC 61000-4-5) || Surges 2 kV)EN/IEC 61000-4-5) || Surges 2 kV)EN/IEC 61000-4-5) || Surges 4 kV)EN/IEC 61000-4-5) || Surges 2 kV)EN/IEC 61000-4-5)
    • Input Current : 3.1 mA 100 V || 7.5 mA 240 V
    • Contacts Type And Composition : 1 NO + 1 NC fault signal || 3 NO
    • Pollution Degree : 3
    • Current State 0 Guaranteed : Logic input 0...40 V <= 15 mA 25 ms
    • Overvoltage Category : III
    • Associated Fuse Rating : 4 A gG output || 0.5 A gG control circuit
    • Operating Rate : 1800 cyc/h
    • Permissible Power : 480 VA AC-15), Ie = 2 A, 500000 cycles output) || 30 W DC-13), Ie = 1.25 A, 500000 cycles output)
    • Web Services : Web server
    • Short-Circuit Withstand : 100 kA EN/IEC 60947-4-1
    • Metering Type : Imbalance current || Earth-fault current || Average current Iavg || Temperature || Phase current I1, I2, I3 RMS
    • Load Current : 5 A 250 V AC logic output || 5 A 30 V DC logic output
    • Height : 2.40 in (61 mm)
    • Maximum Output Switching Frequency : 2 Hz
  • Main
    • Supply Voltage Limits : 93.5…264 V AC
    • Device Application : Equipment monitoring and control
    • Device Short Name : LTMR
    • Measurement Current : 0.4…8 A
    • [Us] Rated Supply Voltage : 100...240 V AC 50/60 Hz
    • Range : TeSys
    • Bus Type : DeviceNet ISO 1198 1...64 125...500 kbit/s, terminal block 4 twisted shielded pairs cable
    • Current Consumption : 8...62.8 mA
    • Product Or Component Type : Motor controller
    • Communication Port Protocol : DeviceNet
    • Product Name : TeSys T
  • Ordering And Shipping Details
    • Category : 22338 - SOLID STATE OVERLOAD RELAYS
    • Country Of Origin : CN
    • GTIN : 00785901502364
    • Nbr. Of Units In Pkg. : 10
    • Discount Schedule : I12
    • Returnability : Yes
  • Offer Sustainability
    • WEEE : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • EU RoHs Directive : Compliant
    • Green Premium Status : Green Premium product
    • Halogen Content Performance : Halogen free plastic parts product
    • Mercury Free : Yes
    • Pvc Free : Yes