• Features
  • Specifications
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Communications & Management Attributes
    • Communication Interface : Digital I/O, Integrated, Analog I/O, Integrated
  • Complementary Attributes
    • US Rated Supply Voltage : 200...240 V - 15...10 %, 380...480 V - 15...10 %
    • Maximum Ambient Air Temperature For Operation : 50.0 °C
    • Maximum Current IRMS : 8.5 A
    • Maximum Operational Altitude : 2000.0 m
    • Minimum Ambient Air Temperature For Operation : 0.0 °C
    • Maximum In Rated Current : 6.0 A
  • Important Information Attributes
    • Persona Type Ids : EU, OM, OM8
    • Persona Type Names : End User, Original Equipment Manufacturer, OEM - Control Panelbuilder
    • Contact Bounce Time : <= 1 ms compliment of STO_A, compliment of STO_B, <= 1 ms compliment of STO_A, compliment of STO_B, 0.25 µs...1.5 ms DI
    • Continuous Power : 400 W 208 V, 800 W 400 V, 800 W 480 V
    • Control Signal Type : servo motor encoder feedback, pulse train output (PTO) RS422 <500 kHz <100 m, pulse/direction (P/D), A/B, CW/CCW 5 V, 24 V link (open collector) <10 kHz <1 m, pulse/direction (P/D), A/B, CW/CCW 5 V, 24 V link (push-pull) <200 kHz <10 m, pulse/direction (P/D), A/B, CW/CCW RS422 <1000 kHz <100 m
    • Electrical Connection : terminal 3 mm², AWG 12 CN8), terminal 5 mm², AWG 10 CN1), terminal 5 mm², AWG 10 CN10)
    • Electromagnetic Compatibility : conducted EMC, class A group 1 EN 55011, conducted EMC, class A group 2 EN 55011, conducted EMC, environment 2 category C3 EN/IEC 61800-3, conducted EMC, category C2 EN/IEC 61800-3, conducted EMC, environments 1 and 2 EN/IEC 61800-3, electrostatic discharge immunity test, level 3 EN/IEC 61000-4-2, susceptibility to electromagnetic fields, level 3 EN/IEC 61000-4-3, 1.2/50 µs shock waves immunity test, level 3 EN/IEC 61000-4-5, electrical fast transient/burst immunity test, level 4 EN/IEC 61000-4-4, radiated EMC, class A group 2 EN 55011, radiated EMC, category C3 EN/IEC 61800-3
    • Line Current : 1.7 A 97 % 208 V, with external line choke 2 mH, 1.8 A 108 % 400 V, with external line choke 2 mH, 1.6 A 116 % 480 V, with external line choke 2 mH, 1.8 A 132 % 208 V, without line choke, 1.4 A 191 % 400 V, without line choke, 1.2 A 201 % 480 V, without line choke
    • Nominal Power : 0.35 kW 208 V 8 kHz, 0.4 kW 400 V 8 kHz, 0.4 kW 480 V 8 kHz
    • Nominal Voltage : 208 V three phase, 400 V three phase, 480 V three phase
    • Protection Type : against reverse polarity inputs signal, against short-circuits outputs signal
    • Response Time : <= 5 ms compliment of STO_A, compliment of STO_B, <= 5 ms compliment of STO_A, compliment of STO_B
    • Safety Level : SIL 3 EN/IEC 61508, PL = e ISO 13849-1
    • Sampling Duration : ANA1+/ANA1-, ANA2+/ANA2- 0.25 ms analog, DI 0.25 ms discrete
    • Supply Voltage : 200-240 V three phase, 380-480 V three phase
    • Supply Voltage Description : three phase 230 V, three phase 400 V
    • Tightening Torque : CN8 0.5-0.5 N.m, CN1 0.7-0.7 N.m, CN10 0.7-0.7 N.m
    • Vibration Resistance : 1 gn (f= 13-150 Hz) conforming to EN/IEC 60068-2-6, 1.5 mm peak to peak (f= 3-13 Hz) conforming to EN/IEC 60068-2-6
    • Carbon Footprint Of The Distribution Phase A4 : 0.2779133321, 0.3 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 1.0056138329, 1 kg CO2 eq.
    • Carbon Footprint Of The Installation Phase A5 : 0 kg CO2 eq., 0.0129267158
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 20 kg CO2 eq., 19.8181966859
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 730 kg CO2 eq., 729.6183745583
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-11-25
    • Device Type : Motion - drive & motor
    • Serviceability : Yes
    • Traceability : Yes
    • Field Service Division : IDIBS
    • Average Life Duration : 15 year(s)
    • WEEE Applicability : Finished product
    • WEEE Scope : In
    • Legacy WEEE Scope : Out
    • Scope Perimeter : At least in Europe
    • EOLI Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI110605EN
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • ROHS EUR In Scope : No
    • ROHS EUR Status : Compliant with Exemptions
    • ROHS EUR Full Compliance Status : Pro-active compliance (Product out of EU RoHS legal scope)
    • ROHS EUR Full Compliance Status Id : PRO_ACTIVE_COMPLIANCE
    • China ROHS In Scope : Yes
    • Green Premium Status For Reporting : Green Premium product
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Return Indicator : N
    • WD Status : 1 - GSC certified
    • Function Option Id : ADVANCED
    • Function Option : Advanced
    • Market Segmentation Id : INDUSTRIAL
    • Market Segmentation : Industrial
    • Braking Current : 50 mA
    • Compatibility Code : LXM32C
    • Derating Altitude Scale : 90.0 m
    • Derating Altitude Start : 1000.0 m
    • Device Short Name : LXM32C
    • Electrical Isolation : between power and control
    • EMC Filter Compatibility : type 022
    • Environmental Characteristic : classes 3C1 conforming to IEC 60721-3-3
    • Field Weakening : false
    • Format Of The Drive : book
    • Maximum Operational Altitude : 2000.0 m
    • Minimum Ambient Air Temperature For Operation : 0.0 °C
    • Package Weight Lbs : 2.154 kg
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Or Component Type : motion servo drive
    • Range Of Product : Lexium 32
    • Returnability : No
    • Safety Function : STO (safe torque off), Integrated
    • Shock Resistance : 15 gn 11 ms EN/IEC 60028-2-27
    • Signalling Function : display of faults 7 segments
    • Status Led : 1 LED (Red) servo drive voltage
    • Supply Frequency : 50/60 Hz - 5...5 %
    • Sustainable Packaging : Yes
    • Switching Frequency : 8 kHz
    • Total Lifecycle Carbon Footprint : 751 kg CO2 eq.
    • Type Of Cable : single-strand IEC cable 50-50 °C) copper 90 °C XLPE/EPR
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Maximum In Rated Current : 6.0 A
    • Relationship Type : Compatible relationship
    • Pep Code : ENVPEP110705EN
    • Pep Verification Date : 2020-08-01
    • PCR Version : PCR-ed3-EN-2015 04 02
    • Type Of Verification For The Pep : Independent internal review
    • Functional Unit Description : To provide the phase currents required for the position control of the connected servo motors 100% of the time for 10 years up to 283W.
    • Functional Unit Unit : unit
    • Product Kit Identifier : N
    • Product Manager : VINIT CHAUDHARI
  • Environment Attributes Main
    • EU ROHS Directive : Compliant By Exemption​, Pro-active compliance (Product out of EU RoHS legal scope)
    • IP Degree Of Protection : IP20 conforming to EN/IEC 60529, IP20 conforming to EN/IEC 61800-5-1
    • Operating Altitude : <= 3280.84 ft (1000 m) without derating, <= 3280.84 ft (1000 m) without derating, > 3280.84...9842.52 ft (> 1000...3000 m) with conditions, > 3280.84...9842.52 ft (> 1000...3000 m) with conditions
    • Product Compatibility : servo motor BMH 70 mm, 1, servo motor BSH 55 mm, 3, servo motor BSH 55 mm, 1, servo motor BSH 55 mm, 2
    • ROHS Exemption Information : Yes
    • Take Back : No
    • Recycled Metal Content At Cr Level : 0 %
    • China ROHS Regulation : X
    • Mercury Free : Yes
    • Carbon Footprint : 750.7330251249
    • Ambient Air Temperature For Operation : 0-50 °C UL
    • Circularity Profile : ENVEOLI110605EN
    • Environmental Disclosure : ENVPEP110705EN
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Relative Humidity : Class 3K3 (5 to 85 %) without condensation IEC 60721-3-3
    • Pep Code : ENVPEP110705EN
    • Pep Verification Date : 2020-08-01
    • PCR Version : PCR-ed3-EN-2015 04 02
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Product Or Component Type : motion servo drive
    • Range Of Product : Lexium 32
  • Output Attributes
    • Discrete Output Voltage : <= 30 V DC, <= 30 V DC
    • Output Current 3s Peak : 6 A 208 V 5 s, 6 A 480 V 5 s
    • Continuous Output Current : 1.5 A 8 kHz
    • Discrete Output Logic : positive or negative DO)EN/IEC 61131-2
    • Discrete Output Type : logic DO)24 V DC
    • Response Time On Output : 250 µs DO)discrete
  • Surge Protection And Filtering Attributes
    • EMC Filter Compatibility : type 022
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Input Attributes
    • Discrete Input Logic : positive compliment of STO_A, compliment of STO_B)< 5 V > 15 V EN/IEC 61131-2 type 1, positive DI)> 19 V < 9 V EN/IEC 61131-2 type 1, positive or negative DI)< 5 V > 15 V EN/IEC 61131-2 type 1
    • Discrete Input Number : 2 safety, 6 logic
    • Discrete Input Type : logic DI, safety compliment of STO_A, compliment of STO_B
    • Discrete Input Voltage : 24 V DC logic, 24 V DC safety
    • Analogue Input Type : ANA1+/ANA1-, ANA2+/ANA2- analog input differential +/- 10 V >= 20 Ohm 14 bits
    • Number Of Inputs Outputs : 6 DI + 5 DO + 2 AI