SQUARE D

motion control stepper motor drive - SD328 - <= 2.5 A

STP D ANALOG P/D MODBUS CANOPE

SQDSD328AU25S2 SD328AU25S2 3389119224369
1662.83 / EA
http://schema.org/OutOfStock
  • Input Voltage: ...10 V, -15 %, 20 %, 24 V
  • Output Voltage: ...5.25 V, 24 V, 30 V, 5 V
  • Warranty Length: 18 mth
This product is part of the Lexium SD3 and motors an offer of 3-phase stepper drives and stepper motors. The 3-phase stepper motor drive with an integrated CANopen and analogue input Modbus communication interface. High torque is available even at low speeds.  It is a motor drive with a rated supply voltage of 100V to 120V, 200V to 230V, a motor phase current of 2.5A, a nominal power of 270W at 230V and maximum mechanical speed of motor drive is 3000RPM. It is furnished with RJ45 connector for CANopen interface, RJ45 connector for Modbus interface, spring terminal for CANopen interface for electrical connection. It is an IP20 and IP40 rated product. Its dimensions are 72mm (Width) x 140mm (Depth) x 145mm (Height). It weighs 1.1kg. The Lexium SD3 with its excellent constant velocity characteristics is ideal for applications such as printing, paper, packaging, handling, labelling, textile industry, scanning, food and beverages. This product is certified by CUL, TUV, CE and UL. It meets EN/IEC 50178, EN/IEC 61800-3 environment 1, EN/IEC 61800-3 environment 1, EN/IEC 61800-3 and EN/IEC 61800-5-1 standards. The SD3 is an universally applicable stepper motor drive. The package is ready for operation within a very short period of time. Connect the stepper motor to the drive, set the current and step resolution. Stepper drives and stepper motors for motion control.
QTY
  • Product Description
  • Features
  • Specifications
This product is part of the Lexium SD3 and motors an offer of 3-phase stepper drives and stepper motors. The 3-phase stepper motor drive with an integrated CANopen and analogue input Modbus communication interface. High torque is available even at low speeds.  It is a motor drive with a rated supply voltage of 100V to 120V, 200V to 230V, a motor phase current of 2.5A, a nominal power of 270W at 230V and maximum mechanical speed of motor drive is 3000RPM. It is furnished with RJ45 connector for CANopen interface, RJ45 connector for Modbus interface, spring terminal for CANopen interface for electrical connection. It is an IP20 and IP40 rated product. Its dimensions are 72mm (Width) x 140mm (Depth) x 145mm (Height). It weighs 1.1kg. The Lexium SD3 with its excellent constant velocity characteristics is ideal for applications such as printing, paper, packaging, handling, labelling, textile industry, scanning, food and beverages. This product is certified by CUL, TUV, CE and UL. It meets EN/IEC 50178, EN/IEC 61800-3 environment 1, EN/IEC 61800-3 environment 1, EN/IEC 61800-3 and EN/IEC 61800-5-1 standards. The SD3 is an universally applicable stepper motor drive. The package is ready for operation within a very short period of time. Connect the stepper motor to the drive, set the current and step resolution. Stepper drives and stepper motors for motion control.
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Communications & Management Attributes
    • Communication Interface : CANopen, Integrated, CANopen, Integrated, analogue input, Integrated, analogue input, Integrated, Modbus, Integrated, Modbus, Integrated
    • Communication Service : 1 PDO configurable CANopen, 1 PDO configurable CANopen, 2 SDOs receive CANopen, 2 SDOs receive CANopen, 2 SDOs send CANopen, 2 SDOs send CANopen, 3 PDOs as per DSP 402 CANopen, 3 PDOs as per DSP 402 CANopen, CiA DSP 402 profile CANopen, CiA DSP 402 profile CANopen, diagnostics (08) Modbus, diagnostics (08) Modbus, emergency CANopen, emergency CANopen, note guarding, heartbeat CANopen, note guarding, heartbeat CANopen, read device identification (43) Modbus, read device identification (43) Modbus, read hold register (03), maximum 63 words Modbus, read hold register (03), maximum 63 words Modbus, read/write multiple registers (23), maximum 63/59 words Modbus, read/write multiple registers (23), maximum 63/59 words Modbus, write multiple registers (16), maximum 61 words Modbus, write multiple registers (16), maximum 61 words Modbus, write single register (06) Modbus, write single register (06) Modbus
  • Complementary Attributes
    • Maximum Input Frequency : 200 kHz signal input ENC_A, ENC_B, ENC_I pulse/direction, 200 kHz signal input ENC_A, ENC_B, ENC_I pulse/direction, 200 kHz signal input ENC_A, ENC_B, ENC_I pulse/direction, 400 kHz signal input ENC_A, ENC_B, ENC_I A/B, 400 kHz signal input ENC_A, ENC_B, ENC_I A/B, 400 kHz signal input ENC_A, ENC_B, ENC_I A/B
    • Maximum Leakage Current : 30 mA <10 m IEC 60990-3, 30 mA <10 m IEC 60990-3, 30 mA <10 m IEC 60990-3
    • Maximum Output Frequency : 400 kHz pulse/direction interface A/B, 400 kHz pulse/direction interface A/B, 400 kHz pulse/direction interface A/B, 200 kHz pulse/direction interface pulse/direction, 200 kHz pulse/direction interface pulse/direction, 200 kHz pulse/direction interface pulse/direction
    • Maximum Switching Current : 50 mA 24 V output signals), 50 mA 24 V output signals)
    • Maximum Voltage Drop : <1 V 50 mA load 24 V output signals, <1 V 50 mA load 24 V output signals, <1 V 50 mA load 24 V output signals
    • US Rated Supply Voltage : 100...120 V - 15...10 %, 100...120 V - 15...10 %, 200...230 V - 15...10 %, 200...230 V - 15...10 %
    • Maximum Mechanical Speed : 3000 rpm
    • Maximum Motor Phase Current : 2.5 A
  • Environment Attributes Additional
    • Energy Model Manufacturing A1 A3 : Energy model used: Germany
    • Energy Model Installation A5 : Electricity grid mix; AC; consumption mix, at consumer; < 1kV; EU-27
    • Energy Model Use B6 : Electricity grid mix; AC; consumption mix, at consumer; < 1kV; EU-27
    • Energy Model End Of Life C1 C4 : Electricity grid mix; AC; consumption mix, at consumer; < 1kV; EU-27
    • Components For Re Use Kg Total Life Cycle : 0
    • Components For Re Use Kg Manufacturing A1 A3 : 0
    • Components For Re Use Kg Distribution A4 : 0
    • Components For Re Use Kg Installation A5 : 0
    • Components For Re Use Kg Operational Energy Use B6 : 0
    • Components For Re Use Kg End Of Life C1 C4 : 0
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Total Life Cycle : 0.0129202401
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Manufacturing A1 A3 : 0.0128732412
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Distribution A4 : 0.0000000065
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Installation A5 : 0.0000000004
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Operational Energy Use B6 : 0.0000469882
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb End Of Life C1 C4 : 0.0000000038
    • Depletion Of Abiotic Resources Fossil Fuels Mj Total Life Cycle : 6420.3361023965
    • Depletion Of Abiotic Resources Fossil Fuels Mj Manufacturing A1 A3 : 277.9411146497
    • Depletion Of Abiotic Resources Fossil Fuels Mj Distribution A4 : 2.2785126592
    • Depletion Of Abiotic Resources Fossil Fuels Mj Installation A5 : 0.1355378264
    • Depletion Of Abiotic Resources Fossil Fuels Mj Operational Energy Use B6 : 6138.3
    • Depletion Of Abiotic Resources Fossil Fuels Mj End Of Life C1 C4 : 1.6809372611
    • Exported Energy Mj By Energy Vector Total Life Cycle : 0.000578213
    • Exported Energy Mj By Energy Vector Manufacturing A1 A3 : 0.000054056
    • Exported Energy Mj By Energy Vector Distribution A4 : 0
    • Exported Energy Mj By Energy Vector Installation A5 : 0.000524157
    • Exported Energy Mj By Energy Vector Operational Energy Use B6 : 0
    • Exported Energy Mj By Energy Vector End Of Life C1 C4 : 0
    • Hazardous Waste Disposed Of Kg Total Life Cycle : 11.6425703845
    • Hazardous Waste Disposed Of Kg Manufacturing A1 A3 : 9.419393551
    • Hazardous Waste Disposed Of Kg Distribution A4 : 0
    • Hazardous Waste Disposed Of Kg Installation A5 : 0.0000004864
    • Hazardous Waste Disposed Of Kg Operational Energy Use B6 : 0.281932
    • Hazardous Waste Disposed Of Kg End Of Life C1 C4 : 1.9412443471
    • Materials For Energy Recovery Kg Total Life Cycle : 0.1324453662
    • Materials For Energy Recovery Kg Manufacturing A1 A3 : 0
    • Materials For Energy Recovery Kg Distribution A4 : 0
    • Materials For Energy Recovery Kg Installation A5 : 0
    • Materials For Energy Recovery Kg Operational Energy Use B6 : 0
    • Materials For Energy Recovery Kg End Of Life C1 C4 : 0.1324453662
    • Materials For Recycling Kg Total Life Cycle : 0.7954708328
    • Materials For Recycling Kg Manufacturing A1 A3 : 0.0856261194
    • Materials For Recycling Kg Distribution A4 : 0
    • Materials For Recycling Kg Installation A5 : 0.1911220462
    • Materials For Recycling Kg Operational Energy Use B6 : 0
    • Materials For Recycling Kg End Of Life C1 C4 : 0.5187226672
    • Net Use Of Fresh Water M3 Total Life Cycle : 1961.0068537998
    • Net Use Of Fresh Water M3 Manufacturing A1 A3 : 0.1665324841
    • Net Use Of Fresh Water M3 Distribution A4 : 0.0000145145
    • Net Use Of Fresh Water M3 Installation A5 : 0.000001128
    • Net Use Of Fresh Water M3 Operational Energy Use B6 : 1960.84
    • Net Use Of Fresh Water M3 End Of Life C1 C4 : 0.0003056732
    • Non Hazardous Waste Disposed Of Kg Total Life Cycle : 2027.9040028167
    • Non Hazardous Waste Disposed Of Kg Manufacturing A1 A3 : 11.6112372611
    • Non Hazardous Waste Disposed Of Kg Distribution A4 : 0.0057622842
    • Non Hazardous Waste Disposed Of Kg Installation A5 : 0.0013623838
    • Non Hazardous Waste Disposed Of Kg Operational Energy Use B6 : 2016.28
    • Non Hazardous Waste Disposed Of Kg End Of Life C1 C4 : 0.0056408876
    • Ozone Depletion Kg Equivalent Cfc 11 Total Life Cycle : 0.0000379654
    • Ozone Depletion Kg Equivalent Cfc 11 Manufacturing A1 A3 : 0.000002714
    • Ozone Depletion Kg Equivalent Cfc 11 Distribution A4 : 0.0000000003
    • Ozone Depletion Kg Equivalent Cfc 11 Installation A5 : 0
    • Ozone Depletion Kg Equivalent Cfc 11 Operational Energy Use B6 : 0.0000352282
    • Ozone Depletion Kg Equivalent Cfc 11 End Of Life C1 C4 : 0.0000000229
    • Radioactive Waste Disposed Of Kg Total Life Cycle : 1.3541978854
    • Radioactive Waste Disposed Of Kg Manufacturing A1 A3 : 0.0076045498
    • Radioactive Waste Disposed Of Kg Distribution A4 : 0.0000041041
    • Radioactive Waste Disposed Of Kg Installation A5 : 0.0000002772
    • Radioactive Waste Disposed Of Kg Operational Energy Use B6 : 1.346576
    • Radioactive Waste Disposed Of Kg End Of Life C1 C4 : 0.0000129543
    • Total Use Of NRE PrE Resources And PrE Resources Used As RawMats Mj TLC : 9784.7614821417
    • Total Use Of NRE PrE Resources And PrE Resources Used As RawMats Mj Mfg A1 A3 : 353.1009076433
    • Total Use Of NRE PrE Resources And PrE Resources Used As RawMats Mj Dist A4 : 2.2900218153
    • Total Use Of NRE PrE Resources And PrE Resources Used As RawMats Mj Inst A5 : 0.1363184475
    • Total Use Of NRE PrE Resources And PrE Resources Used As RawMats Mj OpEnergy B6 : 9427.18
    • Total Use Of NRE PrE Resources And PrE Resources Used As RawMats Mj EoL C1 C4 : 2.0542342357
    • Total Use Of Primary Energy During The Life Cycle Mj Total Life Cycle : 11171.2471023408
    • Total Use Of Primary Energy During The Life Cycle Mj Manufacturing A1 A3 : 366.1813136943
    • Total Use Of Primary Energy During The Life Cycle Mj Distribution A4 : 2.2931242834
    • Total Use Of Primary Energy During The Life Cycle Mj Installation A5 : 0.1365286146
    • Total Use Of Primary Energy During The Life Cycle Mj Operational Energy Use B6 : 10800.58
    • Total Use Of Primary Energy During The Life Cycle Mj End Of Life C1 C4 : 2.0561357484
    • Total Use Of RE PrE Resources And PrE Resources Used As RawMats Mj TLC : 1386.492658088
    • Total Use Of RE PrE Resources And PrE Resources Used As RawMats Mj Mfg A1 A3 : 13.0874116242
    • Total Use Of RE PrE Resources And PrE Resources Used As RawMats Mj Dist A4 : 0.0030560312
    • Total Use Of RE PrE Resources And PrE Resources Used As RawMats Mj Inst A5 : 0.0002104574
    • Total Use Of RE PrE Resources And PrE Resources Used As RawMats Mj OpEnergy B6 : 1373.4
    • Total Use Of RE PrE Resources And PrE Resources Used As RawMats Mj EoL C1 C4 : 0.0019799752
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 9.6728952229
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 9.6728952229
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0
    • Use Of NRE PrE Resources Used As RawMats Mj OpEnergy B6 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 0
    • Use Of NRE PrE Excluding NRE PrE Resources Used As RawMats Mj TLC : 9775.0837830971
    • Use Of NRE PrE Excluding NRE PrE Resources Used As RawMats Mj Mfg A1 A3 : 343.4232085987
    • Use Of NRE PrE Excluding NRE PrE Resources Used As RawMats Mj Dist A4 : 2.2900218153
    • Use Of NRE PrE Excluding NRE PrE Resources Used As RawMats Mj Inst A5 : 0.1363184475
    • Use Of NRE PrE Excluding NRE PrE Resources Used As RawMats Mj OpEnergy B6 : 9427.18
    • Use Of NRE PrE Excluding NRE PrE Resources Used As RawMats Mj EoL C1 C4 : 2.0542342357
    • Use Of Non Renewable Secondary Fuels Mj Total Life Cycle : 0
    • Use Of Non Renewable Secondary Fuels Mj Manufacturing A1 A3 : 0
    • Use Of Non Renewable Secondary Fuels Mj Distribution A4 : 0
    • Use Of Non Renewable Secondary Fuels Mj Installation A5 : 0
    • Use Of Non Renewable Secondary Fuels Mj Operational Energy Use B6 : 0
    • Use Of Non Renewable Secondary Fuels Mj End Of Life C1 C4 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 3.2857139331
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 3.2857139331
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0
    • Use Of RE PrE Resources Used As RawMats Mj OpEnergy B6 : 0
    • Use Of RE PrE Resources Used As RawMats Mj BLB SysBound D : 0
    • Use Of RE PrE Excluding RE PrE Resources Used As RawMats Mj TLC : 1383.2065438364
    • Use Of RE PrE Excluding RE PrE Resources Used As RawMats Mj Mfg A1 A3 : 9.8012973726
    • Use Of RE PrE Excluding RE PrE Resources Used As RawMats Mj Dist A4 : 0.0030560312
    • Use Of RE PrE Excluding RE PrE Resources Used As RawMats Mj Inst A5 : 0.0002104574
    • Use Of RE PrE Excluding RE PrE Resources Used As RawMats Mj OpEnergy B6 : 1373.4
    • Use Of RE PrE Excluding RE PrE Resources Used As RawMats Mj EoL C1 C4 : 0.0019799752
    • Use Of Renewable Secondary Fuels Mj Total Life Cycle : 0
    • Use Of Renewable Secondary Fuels Mj Manufacturing A1 A3 : 0
    • Use Of Renewable Secondary Fuels Mj Distribution A4 : 0
    • Use Of Renewable Secondary Fuels Mj Installation A5 : 0
    • Use Of Renewable Secondary Fuels Mj Operational Energy Use B6 : 0
    • Use Of Renewable Secondary Fuels Mj End Of Life C1 C4 : 0
    • Use Of Secondary Materials Kg Total Life Cycle : 0.2697946338
    • Use Of Secondary Materials Kg Manufacturing A1 A3 : 0.2697946338
    • Use Of Secondary Materials Kg Distribution A4 : 0
    • Use Of Secondary Materials Kg Installation A5 : 0
    • Use Of Secondary Materials Kg Operational Energy Use B6 : 0
    • Use Of Secondary Materials Kg End Of Life C1 C4 : 0
    • Air Pollution M3 Total Life Cycle : 25921.0741709395
    • Air Pollution M3 Manufacturing A1 A3 : 2624.2877388535
    • Air Pollution M3 Distribution A4 : 6.899088535
    • Air Pollution M3 Installation A5 : 0.4158308121
    • Air Pollution M3 Operational Energy Use B6 : 23275
    • Air Pollution M3 End Of Life C1 C4 : 14.4715127389
    • Water Pollution M3 Total Life Cycle : 24636.4544395701
    • Water Pollution M3 Manufacturing A1 A3 : 2267.0035031847
    • Water Pollution M3 Distribution A4 : 26.6702173567
    • Water Pollution M3 Installation A5 : 1.5855613854
    • Water Pollution M3 Operational Energy Use B6 : 22314.6
    • Water Pollution M3 End Of Life C1 C4 : 26.5951576433
    • Acidification Of Soil And Water Kg Equivalent So2 Total Life Cycle : 2.3069378225
    • Photochemical Ozone Formation Kg Equivalent C2h4 Total Life Cycle : 0.1285627324
    • Water Eutrophication Kg Equivalent P04 3 Total Life Cycle : 0.158595022
    • Acidification Of Soil And Water Kg Equivalent So2 Manufacturing A1 A3 : 0.0498786807
    • Acidification Of Soil And Water Kg Equivalent So2 Distribution A4 : 0.0007404991
    • Acidification Of Soil And Water Kg Equivalent So2 Installation A5 : 0.0000435506
    • Acidification Of Soil And Water Kg Equivalent So2 Operational Energy Use B6 : 2.25582
    • Acidification Of Soil And Water Kg Equivalent So2 End Of Life C1 C4 : 0.000455092
    • Global Warming Kg Equivalent Co2 Total Life Cycle : 567.291066336
    • Global Warming Kg Equivalent Co2 Manufacturing A1 A3 : 25.8055294586
    • Global Warming Kg Equivalent Co2 Distribution A4 : 0.1621790207
    • Global Warming Kg Equivalent Co2 Installation A5 : 0.0104122834
    • Global Warming Kg Equivalent Co2 Operational Energy Use B6 : 540.778
    • Global Warming Kg Equivalent Co2 End Of Life C1 C4 : 0.5349455732
    • Photochemical Ozone Formation Kg Equivalent C2h4 Manufacturing A1 A3 : 0.0045171936
    • Photochemical Ozone Formation Kg Equivalent C2h4 Distribution A4 : 0.000052842
    • Photochemical Ozone Formation Kg Equivalent C2h4 Installation A5 : 0.0000032466
    • Photochemical Ozone Formation Kg Equivalent C2h4 Operational Energy Use B6 : 0.123949
    • Photochemical Ozone Formation Kg Equivalent C2h4 End Of Life C1 C4 : 0.0000404502
    • Water Eutrophication Kg Equivalent P04 3 Manufacturing A1 A3 : 0.0220255223
    • Water Eutrophication Kg Equivalent P04 3 Distribution A4 : 0.0001705557
    • Water Eutrophication Kg Equivalent P04 3 Installation A5 : 0.0000105534
    • Water Eutrophication Kg Equivalent P04 3 Operational Energy Use B6 : 0.136199
    • Water Eutrophication Kg Equivalent P04 3 End Of Life C1 C4 : 0.0001893907
  • Important Information Attributes
    • Persona Type Ids : EU, OM, OM8
    • Persona Type Names : End User, Original Equipment Manufacturer, OEM - Control Panelbuilder
    • Associated Fuse Rating : 6 A 115 V, 6 A 115 V, 6 A 230 V, 6 A 230 V
    • Current Consumption : 3 A 230 V main supply, 3 A 230 V main supply, 3 A 230 V main supply, 4 A 115 V main supply, 4 A 115 V main supply, 4 A 115 V main supply, <= 0.2 mA 24 V control voltage, <= 0.2 mA 24 V control voltage
    • Data Format : 8 bits, 1 stop, even parity Modbus, 8 bits, 1 stop, even parity Modbus, 8 bits, no parity, 1 stop Modbus, 8 bits, no parity, 1 stop Modbus, 8 bits, no parity, 2 stop Modbus, 8 bits, no parity, 2 stop Modbus, 8 bits, odd parity, 1 stop Modbus, 8 bits, odd parity, 1 stop Modbus
    • Electrical Connection : connector RJ45 CANopen interface, connector RJ45 CANopen interface, connector RJ45 CANopen interface, connector RJ45 Modbus interface, connector RJ45 Modbus interface, connector RJ45 Modbus interface, spring terminal CANopen interface, spring terminal CANopen interface
    • Electromagnetic Compatibility : electrostatic discharge level 3 conforming to IEC 61000-4-2, electrostatic discharge level 3 conforming to IEC 61000-4-2, electrostatic discharge level 3 conforming to IEC 61000-4-2, immunity to electrical transients level 4 conforming to IEC 61000-4-4, immunity to electrical transients level 4 conforming to IEC 61000-4-4, immunity to electrical transients level 4 conforming to IEC 61000-4-4, immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3, immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3, immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3, voltage/current impulse level 3 conforming to IEC 61000-4-5, voltage/current impulse level 3 conforming to IEC 61000-4-5, voltage/current impulse level 3 conforming to IEC 61000-4-5
    • Installed Device : 127 stepper motor drives CANopen, 127 stepper motor drives CANopen, 31 stepper motor drives Modbus, 31 stepper motor drives Modbus
    • Local Signalling : 1 LED - ERR CANopen, 1 LED - ERR CANopen, 1 LED - ERR CANopen, 1 LED - RUN CANopen, 1 LED - RUN CANopen, 1 LED - RUN CANopen
    • Method Of Access : slave CANopen, slave CANopen
    • Mode Of Transmission : RTU Modbus, RTU Modbus
    • Network Frequency Limits : 50-60 Hz - 15...10 %), 50-60 Hz - 15...10 %)
    • Nominal Power : 180 W 115 V, 180 W 115 V, 270 W 230 V, 270 W 230 V
    • Number Of Addresses : 1-127 CANopen, 1-127 CANopen, 1-247 Modbus, 1-247 Modbus
    • Residual Ripple : < 5 % 24 V control voltage), < 5 % 24 V control voltage)
    • Resistance : 5 kOhm pulse/direction interface), 5 kOhm pulse/direction interface), 10 kOhm analogue input signals), 10 kOhm analogue input signals)
    • Safety Function : safe torque off safety function machine IEC/EN 61800-5-2, safe torque off safety function machine IEC/EN 61800-5-2, safe torque off safety function machine IEC/EN 61800-5-2, safe torque off safety function machine ISO 13849-1 level d, safe torque off safety function machine ISO 13849-1 level d, safe torque off safety function machine ISO 13849-1 level d, safe torque off safety function system process EN/IEC 61508 level SIL2, safe torque off safety function system process EN/IEC 61508 level SIL2, safe torque off safety function system process EN/IEC 61508 level SIL2, safe torque off safety function system process IEC/EN 61800-5-2, safe torque off safety function system process IEC/EN 61800-5-2, safe torque off safety function system process IEC/EN 61800-5-2
    • Shock Resistance : 15 gn 11 ms IEC 60068-2-27, 15 gn 11 ms IEC 60068-2-27, 15 gn 11 ms IEC 60068-2-27
    • Supply Voltage Description : single phase 230 V, single phase 115 V
    • Transmission Rate : 125 kbps, 250 kbps, 500 kbps, 1 Mbps CANopen, 125 kbps, 250 kbps, 500 kbps, 1 Mbps CANopen, 9600, 19200, 38400 bps Modbus, 9600, 19200, 38400 bps Modbus
    • Vibration Resistance : 1 gn (f= 13-150 Hz) conforming to IEC 60068-2-6, 1 gn (f= 13-150 Hz) conforming to IEC 60068-2-6, 1 gn (f= 13-150 Hz) conforming to IEC 60068-2-6, 1.5 mm (f= 3-13 Hz) conforming to IEC 60068-2-6, 1.5 mm (f= 3-13 Hz) conforming to IEC 60068-2-6, 1.5 mm (f= 3-13 Hz) conforming to IEC 60068-2-6
    • Voltage State 0 Guaranteed : -3...5 V 24 V input signals, -3...5 V 24 V input signals
    • Voltage State 1 Guaranteed : 15...30 V 24 V input signals, 15...30 V 24 V input signals
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-05-15
    • Device Type : Motion - drive & motor
    • Serviceability : Yes
    • Traceability : Yes
    • Field Service Division : IDIBS
    • Average Life Duration : 15 year(s)
    • Legacy WEEE Scope : Out
    • Scope Perimeter : At least in Europe
    • EOLI Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI111103EN
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • ROHS EUR In Scope : No
    • ROHS EUR Status : Compliant with Exemptions
    • ROHS EUR Full Compliance Status : Pro-active compliance (Product out of EU RoHS legal scope)
    • ROHS EUR Full Compliance Status Id : PRO_ACTIVE_COMPLIANCE
    • China ROHS In Scope : Yes
    • Green Premium Status For Reporting : Green Premium product
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : No
    • Product Contributes To Saved And Avoided Emissions : No
    • Return Indicator : N
    • WD Status : 1 - GSC certified
    • Function Option Id : ADVANCED
    • Function Option : Advanced
    • Market Segmentation Id : INDUSTRIAL
    • Market Segmentation : Industrial
    • Compatibility Code : SD328
    • Device Short Name : SD328
    • Format Of The Drive : block
    • Package Weight Lbs : 1.247 kg
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Or Component Type : motion stepper drive
    • Range Of Product : Lexium SD3
    • Returnability : No
    • Supply Voltage Type : AC/DC
    • Sustainable Packaging : No
    • Total Lifecycle Carbon Footprint : 567 kg CO2 eq.
    • Relationship Type : Compatible relationship
    • Pep Code : ENVPEP1111015EN
    • Pep Verification Date : 2020-10-01
    • PCR Version : PCR-ed3-EN-2015 04 02
    • Type Of Verification For The Pep : Independent internal review
    • Functional Unit Description : To drive 3-phase stepper motors 70% of the time for 10 years
    • Functional Unit Unit : unité (unit)
    • Product Kit Identifier : N
    • Huella De Carbono De La Fase De Distribución A4 : 0.2 kg CO2 eq.
    • Huella De Carbono De La Fase De Fabricación A1 A A3 : 26 kg CO2 eq.
    • Huella De Carbono De La Fase De Fin De Vida C1 A C4 : 0.5 kg CO2 eq.
    • Huella De Carbono De La Fase De Instalación A5 : 0 kg CO2 eq.
    • Huella De Carbono De La Fase De Uso B2 B3 B4 B6 : 541 kg CO2 eq.
  • Environment Attributes Main
    • EU ROHS Directive : Compliant By Exemption​, Pro-active compliance (Product out of EU RoHS legal scope)
    • IP Degree Of Protection : IP20, on upper part: IP40 (without removal of protective film), on upper part: IP40 (without removal of protective film), on upper part: IP40 (without removal of protective film)
    • Operating Altitude : <= 3280.84 ft (1000 m) without derating, <= 3280.84 ft (1000 m) without derating, > 3280.84...< 6561.68 ft (> 1000...< 2000 m) without derating maximum ambient temperature 40°C, no protective film, lateral distance of > 50mm), > 3280.84...< 6561.68 ft (> 1000...< 2000 m) without derating maximum ambient temperature 40°C, no protective film, lateral distance of > 50mm), > 3280.84...< 6561.68 ft (> 1000...< 2000 m) without derating maximum ambient temperature 40°C, no protective film, lateral distance of > 50mm)
    • Relative Humidity : 5-85 % without condensation, 5-85 % without condensation
    • ROHS Exemption Information : Yes
    • Take Back : No
    • Recycled Metal Content At Cr Level : 0 %
    • China ROHS Regulation : X
    • Mercury Free : Yes
    • Carbon Footprint : 567.291066336
    • Ambient Air Temperature For Operation : 0-50 °C
    • Circularity Profile : ENVEOLI111103EN
    • Environmental Disclosure : ENVPEP1111015EN
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : No
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP1111015EN
    • Pep Verification Date : 2020-10-01
    • PCR Version : PCR-ed3-EN-2015 04 02
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Product Or Component Type : motion stepper drive
    • Range Of Product : Lexium SD3
  • Output Attributes
    • Maximum Output Frequency : 400 kHz pulse/direction interface A/B, 400 kHz pulse/direction interface A/B, 400 kHz pulse/direction interface A/B, 200 kHz pulse/direction interface pulse/direction, 200 kHz pulse/direction interface pulse/direction, 200 kHz pulse/direction interface pulse/direction
    • Output Voltage : <= 30 V 24 V output signals), <= 30 V 24 V output signals), 4.75...5.25 V ENC+5V_OUT signal output), 4.75...5.25 V ENC+5V_OUT signal output)
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Input Attributes
    • Analogue Input Type : voltage - 10...10 V 14 bits 0.25 ms, voltage - 10...10 V 14 bits 0.25 ms, voltage - 10...10 V 14 bits 0.25 ms, voltage - 10...10 V 14 bits 0.25 ms
    • Input Current : 10 mA 24 V input signals, 10 mA 24 V input signals
    • Input Voltage : 24 V -15 %/+20 % 24 V control voltage, 24 V -15 %/+20 % 24 V control voltage, -10...10 V analogue input signals, -10...10 V analogue input signals
    • Maximum Input Frequency : 200 kHz signal input ENC_A, ENC_B, ENC_I pulse/direction, 200 kHz signal input ENC_A, ENC_B, ENC_I pulse/direction, 200 kHz signal input ENC_A, ENC_B, ENC_I pulse/direction, 400 kHz signal input ENC_A, ENC_B, ENC_I A/B, 400 kHz signal input ENC_A, ENC_B, ENC_I A/B, 400 kHz signal input ENC_A, ENC_B, ENC_I A/B