Harmony, Modular 3-phase supply control relay, 8A, 2 CO, 183…528VAC

PHASE CTRL RELAY 208-480VAC I

SQDRM22TG20 RM22TG20 3606480792137
85.01 / EA
http://schema.org/OutOfStock
  • Width: 22.5 mm
This Harmony RM22TG control relay allows monitoring of power supply circuits in 3-phase networks. This modular 3-phase control relay is ideal for monitoring of electrical values in industrial and building control panels. It applies to a wide type of industrial automation applications such as hoisting, packaging, lifts, textile, water. It has one of market slim form-factors with 22.5mm width, allowing for a flexible and easy installation on DIN rail, using the same space as any modular 1-pole DIN device. It also offers a selectable memory function, integral LED for indicating control status, sealable cover, with simple and precise settings with screw trimmers. It provides automatic shutdown management and fault information to user for a quick fault identification and troubleshooting. Multi function controller for wide choice selected in hard-wired logic automated systems, ideal for refurbishment of old installations without using a PLC. 0 0 0 0 0 0 0 0 0 0 0 0
QTY
  • Product Description
  • Features
  • Specifications
This Harmony RM22TG control relay allows monitoring of power supply circuits in 3-phase networks. This modular 3-phase control relay is ideal for monitoring of electrical values in industrial and building control panels. It applies to a wide type of industrial automation applications such as hoisting, packaging, lifts, textile, water. It has one of market slim form-factors with 22.5mm width, allowing for a flexible and easy installation on DIN rail, using the same space as any modular 1-pole DIN device. It also offers a selectable memory function, integral LED for indicating control status, sealable cover, with simple and precise settings with screw trimmers. It provides automatic shutdown management and fault information to user for a quick fault identification and troubleshooting. Multi function controller for wide choice selected in hard-wired logic automated systems, ideal for refurbishment of old installations without using a PLC. 0 0 0 0 0 0 0 0 0 0 0 0
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Complementary Attributes
    • Us Rated Supply Voltage : , self-powered, AC/DC, , self-powered
    • Control Circuit Voltage Limits : 183...528 V AC
    • Line Rated Current : 8 A
    • Maximum Switching Current : 8 A AC
    • Maximum Switching Voltage : 250 V AC
    • Minimum Switching Current : 10 mA 5 V DC
    • Uc Control Circuit Voltage : 208...480 V
  • Important Information Attributes
    • Persona Type Ids : BM9, EU, LC, OM, OM8, PB, SC, SI, VR
    • Persona Type Names : Charge Point Operator, End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, Electrician, System Integrator, IT Channel Partner
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Electromagnetic Compatibility : immunity for residential, commercial and light-industrial environments conforming to IEC 61000-6-1, immunity for industrial environments conforming to IEC 61000-6-2, emission standard for residential, commercial and light-industrial environments conforming to IEC 61000-6-3, emission standard for industrial environments conforming to IEC 61000-6-4, electrostatic discharge - test level: 6 kV level 3 (contact discharge) conforming to IEC 61000-4-2, electrostatic discharge - test level: 8 kV level 3 (air discharge) conforming to IEC 61000-4-2, radiated radio-frequency electromagnetic field immunity test - test level: 10 V/m level 3 conforming to IEC 61000-4-3, electrical fast transient/burst immunity test - test level: 4 kV level 4 (direct) conforming to IEC 61000-4-4, electrical fast transient/burst immunity test - test level: 2 kV level 4 (capacitive coupling) conforming to IEC 61000-4-4, surge immunity test - test level: 4 kV level 4 (common mode) conforming to IEC 61000-4-5, surge immunity test - test level: 2 kV level 4 (differential mode) conforming to IEC 61000-4-5, conducted and radiated emissions class B group 1 conforming to CISPR 11, conducted and radiated emissions class B conforming to CISPR 22
    • Insulation Resistance : > 100 MOhm 500 V DC IEC 60255-27, > 100 MOhm 500 V DC IEC 60255-27, > 100 MOhm 500 V DC IEC 60255-27, > 100 MOhm 500 V DC IEC 60255-27, > 100 MOhm 500 V DC IEC 60255-27, > 100 MOhm 500 V DC IEC 60255-27, > 100 MOhm 500 V DC IEC 60255-27, > 100 MOhm 500 V DC IEC 60255-27
    • Overvoltage Category : III conforming to IEC 60664-1, III conforming to UL 508
    • Relay Monitored Parameters : phase failure detection (2 or more phase cut), phase sequencephase failure detection (2 or more phase cut)
    • Response Time : <= 200 ms, <= 200 ms
    • Safety Reliability Data : MTTFd = 924.6 years, B10d = 850000
    • Shock Resistance : 15 gn 11 ms) not in operation IEC 60068-2-27, 5 gn 11 ms) in operation IEC 60068-2-27
    • Status Led : LED (Yellow) relay ON, LED (Green) power ON
    • Utilisation Category : AC-15 IEC 60947-5-1, DC-13 IEC 60947-5-1, AC-1 IEC 60947-4-1, DC-1 IEC 60947-4-1
    • Vibration Resistance : 0.075 mm 10-58.1 Hz) not in operation IEC 60068-2-6, 1 gn 10-58.1 Hz) not in operation IEC 60068-2-6, 0.035 mm 58.1-150 Hz) in operation IEC 60068-2-6, 0.5 gn 58.1-150 Hz) in operation IEC 60068-2-6
    • Voltage Detection Threshold : < 100 V AC, < 100 V AC, < 100 V AC, < 100 V AC
    • Connections Terminals : screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end, screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) flexible with cable end, screw terminals, 1 x 0.5...1 x 3.3 mm² AWG 20...AWG 12) solid without cable end, screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 14) flexible with cable end, screw connectors
    • Carbon Footprint Of The Distribution Phase A4 : 0.0116116364, 0 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 0.0522965455, 0.1 kg CO2 eq.
    • Carbon Footprint Of The Installation Phase A5 : 0 kg CO2 eq., 0.0004490264
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 2 kg CO2 eq., 1.8499090909
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 93 kg CO2 eq., 92.70576
    • Certificate Agency : CE, EAC, RCM, GL, CSA, UL, CCC
    • Local Data Status : Publishable
    • Local Publishable Date : 2026-03-26
    • Return Indicator : Y
    • Stocking Flag : N
    • Stock Policy : 2
    • Weee Scope : Out
    • Weee Product Category : 5
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI2506066EN
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : No
    • Rohs Eur Status : Compliant By Exemption
    • Rohs Eur Conformity Date : 1918
    • Rohs Eur Full Compliance Status : Compliant By Exemption
    • China Rohs In Scope : Yes
    • China Rohs Label : 5
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Tier Id : 1
    • Tier : 1
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Product Kit Identifier : N
    • Compatibility Code : RM22
    • Contacts Material : cadmium free
    • Contacts Type And Composition : 2 C/O
    • Control Type : with test button
    • Dielectric Test Voltage : 2.5 kV AC 50 Hz, 1 min IEC 60255-27
    • Electrical Durability : 100000 cycles
    • Housing Material : polycarbonate
    • Immunity To Microbreaks : 10 ms
    • Measurement Range : 208...480 V voltage AC
    • Mechanical Durability : 10000000 cycles
    • Mounting Position : any position
    • Mounting Support : 35 mm DIN rail conforming to IEC 60715
    • Phase : 3 phase
    • Power Consumption In Va : 15-15 VA 480 V AC 60 Hz
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Or Component Type : 3-phase control relay
    • Range Of Product : Harmony Control Relays
    • Relay Name : RM22TG
    • Relay Type : control relay
    • Reset Time : 1500 ms at maximum voltage
    • Returnability : Yes
    • Run Up Delay At Power Up : 650 ms
    • Software Version : EIME v5.8.1
    • Supply Frequency : 50...60 Hz +/- 10 %
    • Supply Voltage Limits : 183-528 V AC
    • Sustainable Packaging : Yes
    • Switching Capacity In Va : 2000 VA
    • Tightening Torque : 0.6-1 N.m IEC 60947-1
    • Time Delay Type : without
    • Total Lifecycle Carbon Footprint : 95 kg CO2 eq.
    • Warranty In Months : 18
    • Contacts Composition : 2 C/O
    • Measurement Range 4 : 208...480 V voltage AC
    • Pep Code : ENVPEP2506066EN
    • Database Version : 2016-11
    • Pep Verification Date : 2019-05-01
    • Pcr Version : PCR-ed3-EN-2015 04 02
    • Psr Version : PSR-0005-ed2-EN-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
    • Data Source : extrapolated product
    • Functional Unit Description : To switch ON/OFF electrical contacts when the abnormal operating conditions is detected during 10 years and a 100% use rate.
    • Functional Unit Quantity : 1
    • Functional Unit Unit : unité (unit)
    • Reference Lifetime In Y2 : 10
    • Energy Consumption On Product Lifetime In Kwh : 189.216
    • Energy Model Manufacturing A1 A3 2 : Energy model used: Indonesia
    • Energy Model Installation A5 2 : Electricity mix; AC; < 1kV; EU-27
    • Energy Model Use B6 2 : Electricity mix; AC; < 1kV; EU-27
    • Energy Model End Of Life C1 C4 2 : Electricity mix; AC; < 1kV; EU-27
    • Offer Owner Code : 190786
    • Pn : 1
    • Width Nominal : 22.5 mm
    • Depletion Of Abiotic Resources Fossil Fuels Mj Operational Energy Use B6 2 : 1052.28
    • Net Use Of Fresh Water M3 Operational Energy Use B6 2 : 336.1392
    • Non Hazardous Waste Disposed Of Kg Operational Energy Use B6 2 : 345.6432
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 2 : 1616.112
    • Total Use Of Primary Energy During The Life Cycle Mj Operational Energy Use B6 2 : 1851.552
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 2 : 235.44
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 2 : 1616.112
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 2 : 235.44
    • Air Pollution M3 Operational Energy Use B6 2 : 3990.096
    • Water Pollution M3 Operational Energy Use B6 2 : 3825.36
  • Environment Attributes Main
    • Ambient Air Temperature For Operation : -20-50 °C 60 Hz, -20-50 °C 60 Hz, -20-60 °C 50 Hz AC/DC, -20-60 °C 50 Hz AC/DC, -20-60 °C 50 Hz AC/DC, -20-50 °C 60 Hz, -20-50 °C 60 Hz, -20-60 °C 50 Hz AC/DC, -20-60 °C 50 Hz AC/DC
    • Ip Degree Of Protection : IP20 IEC 60529 terminals), IP40 IEC 60529 housing), IP50 IEC 60529 front panel)
    • Take Back : No
    • Recycled Metal Content At Cr Level : 0 %
    • China Rohs Regulation : X
    • Mercury Free : Yes
    • Carbon Footprint : 94.6200262991
    • Ambient Air Temperature For Storage : -40-70 °C
    • Circularity Profile : ENVEOLI2506066EN
    • Environmental Disclosure : ENVPEP2506066EN
    • Eu Rohs Directive : Compliant By Exemption
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Relative Humidity : 93-97 % 25-55 °C IEC 60068-2-30
    • Pep Code : ENVPEP2506066EN
    • Pep Verification Date : 2019-05-01
    • Pcr Version : PCR-ed3-EN-2015 04 02
    • Psr Version : PSR-0005-ed2-EN-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Phase : 3 phase
    • Product Or Component Type : 3-phase control relay
    • Range Of Product : Harmony Control Relays
  • ETIM
    • ETIM 8 : EC001441
    • ETIM 9 : EC001441
  • Output Attributes
    • Output Contacts : 2 C/O
  • Specifications
    • Width : 22.5 mm
    • Country of Origin : Brazil, France, Indonesia, Sweden