voltage control relay, Harmony Control Relays, 5A, 2CO, range 15..600V, 24..240V AC DC

VOLTAGE RELAY 250V 5AMP RM35

SQDRM35UA13MW RM35UA13MW 3389119405317
185.23 / EA
http://schema.org/OutOfStock
  • Operating Position: Any Position Without Derating
  • Warranty Length: 18 mth
This Harmony RM35-U multi function control relay allows monitoring of voltage control. This modular multi function control relay is ideal for monitoring of electrical values and voltage variation in industrial and building control panels. It applies to a wide type of industrial automation applications such as hoisting, packaging, lifts, textile, water. It has one of market medium form-factors with 35mm width, allowing for a flexible and easy installation on DIN rail, using the same space as any modular 3-pole DIN device. It also offers a selectable memory function, integral LED for indicating control status, sealable cover, with simple and precise settings with screw trimmers. It provides automatic shutdown management and fault information to user for a quick fault identification and troubleshooting. Multi function controller for wide choice selected in hard-wired logic automated systems, ideal for refurbishment of old installations without using a PLC. 0 0 0 0 0 0 0 0 0 0 0 0
QTY
  • Product Description
  • Features
  • Specifications
This Harmony RM35-U multi function control relay allows monitoring of voltage control. This modular multi function control relay is ideal for monitoring of electrical values and voltage variation in industrial and building control panels. It applies to a wide type of industrial automation applications such as hoisting, packaging, lifts, textile, water. It has one of market medium form-factors with 35mm width, allowing for a flexible and easy installation on DIN rail, using the same space as any modular 3-pole DIN device. It also offers a selectable memory function, integral LED for indicating control status, sealable cover, with simple and precise settings with screw trimmers. It provides automatic shutdown management and fault information to user for a quick fault identification and troubleshooting. Multi function controller for wide choice selected in hard-wired logic automated systems, ideal for refurbishment of old installations without using a PLC. 0 0 0 0 0 0 0 0 0 0 0 0
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Complementary Attributes
    • UI Rated Insulation Voltage : 250 V IEC 60664-1, 600 V IEC 60664-1
    • Control Circuit Frequency : 40...70 Hz +/- 10 %
    • Maximum Measuring Cycle : 30 ms measurement cycle as true rms value
    • Maximum Power Consumption In W : 0.6 W DC
    • Maximum Switching Current : 5 A AC/DC
    • Maximum Switching Voltage : 250 V AC/DC
    • Minimum Switching Current : 10 mA 5 V DC
    • US Rated Supply Voltage : 24...240 V AC/DC 50/60 Hz, non self-powered
  • Important Information Attributes
    • Persona Type Ids : BM9, EU, LC, OM, OM8, PB, SC, SI, VR
    • Persona Type Names : Charge Point Operator, End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, Electrician, System Integrator, IT Channel Partner
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Dielectric Test Voltage : 2 kV AC 50 Hz, 1 min IEC 60255-5, 2 kV AC 50 Hz, 1 min IEC 60664-1
    • Electromagnetic Compatibility : emission standard for industrial environments conforming to IEC 61000-6-4, emission standard for residential, commercial and light-industrial environments conforming to IEC 61000-6-3, immunity for industrial environments conforming to NF EN/IEC 61000-6-2
    • Insulation Resistance : > 500 MOhm 500 V DC between supply and relay output IEC 60255-5, > 500 MOhm 500 V DC between supply and relay output IEC 60255-5, > 500 MOhm 500 V DC between supply and relay output IEC 60255-5, > 500 MOhm 500 V DC between supply and relay output IEC 60255-5, > 500 MOhm 500 V DC between supply and relay output IEC 60255-5, > 500 MOhm 500 V DC between measurement and relay output IEC 60664-1, > 500 MOhm 500 V DC between measurement and relay output IEC 60664-1, > 500 MOhm 500 V DC between measurement and relay output IEC 60664-1, > 500 MOhm 500 V DC between measurement and relay output IEC 60664-1, > 500 MOhm 500 V DC between measurement and relay output IEC 60664-1, > 1 MOhm 500 V DC between supply and measurement IEC 60255-5, > 1 MOhm 500 V DC between supply and measurement IEC 60255-5, > 1 MOhm 500 V DC between supply and measurement IEC 60255-5, > 1 MOhm 500 V DC between supply and measurement IEC 60255-5, > 1 MOhm 500 V DC between supply and measurement IEC 60255-5, > 500 MOhm 500 V DC between supply and relay output IEC 60664-1, > 500 MOhm 500 V DC between supply and relay output IEC 60664-1, > 500 MOhm 500 V DC between supply and relay output IEC 60664-1, > 500 MOhm 500 V DC between supply and relay output IEC 60664-1, > 500 MOhm 500 V DC between supply and relay output IEC 60664-1, > 500 MOhm 500 V DC between measurement and relay output IEC 60255-5, > 500 MOhm 500 V DC between measurement and relay output IEC 60255-5, > 500 MOhm 500 V DC between measurement and relay output IEC 60255-5, > 500 MOhm 500 V DC between measurement and relay output IEC 60255-5, > 500 MOhm 500 V DC between measurement and relay output IEC 60255-5, > 1 MOhm 500 V DC between supply and measurement IEC 60664-1, > 1 MOhm 500 V DC between supply and measurement IEC 60664-1, > 1 MOhm 500 V DC between supply and measurement IEC 60664-1, > 1 MOhm 500 V DC between supply and measurement IEC 60664-1, > 1 MOhm 500 V DC between supply and measurement IEC 60664-1
    • Local Signalling : LED (green) for power ON, LED (yellow) for relay ON
    • Measurement Error : +/- 0.05 %/°C with temperature variation, +/- 0.05 %/°C with temperature variation, < 1 % over the whole range with voltage variation, < 1 % over the whole range with voltage variation
    • Non Dissipating Shock Wave : 4 kV IEC 60255-5, 4 kV IEC 60664-1, 4 kV IEC 61000-4-5
    • Operating Rate : <= 360 operations/hour full load, <= 360 operations/hour full load
    • Repeat Accuracy : +/- 0.5 % input and measurement circuit, +/- 0.5 % input and measurement circuit, +/- 2 % time delay, +/- 2 % time delay
    • Resistance Across Terminals : 150 mOhm E1-M terminals, 300 mOhm E2-M terminals, 600 mOhm E3-M terminals
    • Sensitivity Scale : 15...150 V E1-M terminals, 30...300 V E2-M terminals, 60...600 V E3-M terminals
    • Utilisation Category : AC-12 IEC 60947-5-1, AC-13 IEC 60947-5-1, AC-14 IEC 60947-5-1, AC-15 IEC 60947-5-1, DC-12 IEC 60947-5-1, DC-13 IEC 60947-5-1, DC-14 IEC 60947-5-1
    • Vibration Resistance : 0.35 mm (f= 5-57.6 Hz) conforming to IEC 60068-2-6, 1 gn (f= 57.6-150 Hz) conforming to IEC 60255-21-1
    • Carbon Footprint Of The Distribution Phase A4 : 0.0103214545, 0 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 0.0464858182, 0 kg CO2 eq.
    • Carbon Footprint Of The Installation Phase A5 : 0 kg CO2 eq., 0.0003991345
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 2 kg CO2 eq., 1.6443636364
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 62 kg CO2 eq., 61.80384
    • Connections Terminals : screw terminals, 1 x 0.5...1 x 4 mm² AWG 20...AWG 11) solid without cable end, screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end, screw terminals, 1 x 0.2...2 x 2.5 mm² AWG 24...AWG 12) flexible with cable end, screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) flexible with cable end
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-11-23
    • Legacy WEEE Scope : Out
    • Scope Perimeter : At least in Europe
    • EOLI Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI1601004EN
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • ROHS EUR In Scope : No
    • ROHS EUR Status : Compliant with Exemptions
    • ROHS EUR Full Compliance Status : Pro-active compliance (Product out of EU RoHS legal scope)
    • ROHS EUR Full Compliance Status Id : PRO_ACTIVE_COMPLIANCE
    • China ROHS In Scope : Yes
    • Green Premium Status For Reporting : Green Premium product
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Return Indicator : Y
    • WD Status : 1 - GSC certified
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Compatibility Code : RM3
    • Housing Material : polycarbonate
    • Hysteresis : 5-50 % threshold setting
    • Immunity To Microbreaks : 10 ms
    • Measurement Range : 15...600 V AC/DC
    • Mounting Support : 35 mm symmetrical DIN rail conforming to IEC 60715
    • Operating Position : any position without derating
    • Overvoltage Category : III conforming to IEC 60664-1
    • Package Weight Lbs : 136.0 g
    • Power Consumption In VA : 0-3.5 VA AC
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Or Component Type : voltage control relay
    • Quality Labels : CE
    • Range Of Product : Harmony Control Relays
    • Relay Monitored Parameters : overvoltage or undervoltage detection
    • Relay Name : RM35UA
    • Reset Time : 1500 ms time delay
    • Returnability : Yes
    • Run Up Delay At Power Up : 600 ms
    • Shock Resistance : 5 gn IEC 60068-2-27
    • Supply Voltage Limits : 20.4-264 V AC/DC
    • Sustainable Packaging : Yes
    • Tightening Torque : 0.6-1 N.m IEC 60947-1
    • Time Delay Type : adjustable 0.3...30 s, 0 + 10 % Tt- time delay upon fault
    • Total Lifecycle Carbon Footprint : 64 kg CO2 eq.
    • Pep Code : ENVPEP1601004EN
    • Pep Verification Date : 2019-05-01
    • PCR Version : PCR-ed3-EN-2015 04 02
    • PSR Version : PSR-0005-ed2-EN-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
    • Functional Unit Description : To switch ON/OFF electrical contacts when the abnormal operating conditions is detected during 10 years and a 100% use rate.
    • Functional Unit Unit : unité (unit)
    • Product Kit Identifier : N
  • Environment Attributes Main
    • Directives : 73/23/EEC - low voltage directive, 89/336/EEC - electromagnetic compatibility
    • EU ROHS Directive : Compliant By Exemption​, Pro-active compliance (Product out of EU RoHS legal scope)
    • IP Degree Of Protection : IP20 IEC 60529 terminals), IP30 IEC 60529 casing)
    • Take Back : No
    • Recycled Metal Content At Cr Level : 0 %
    • China ROHS Regulation : X
    • Mercury Free : Yes
    • Carbon Footprint : 63.5054100436
    • Ambient Air Temperature For Operation : -20-50 °C
    • Circularity Profile : ENVEOLI1601004EN
    • Environmental Disclosure : ENVPEP1601004EN
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Relative Humidity : 95-95 % 55-55 °C IEC 60068-2-30
    • Pep Code : ENVPEP1601004EN
    • Pep Verification Date : 2019-05-01
    • PCR Version : PCR-ed3-EN-2015 04 02
    • PSR Version : PSR-0005-ed2-EN-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Product Or Component Type : voltage control relay
    • Range Of Product : Harmony Control Relays
  • Output Attributes
    • Output Contacts : 2 C/O
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months