current control relay, Harmony Control Relays, 5A, 2CO, 2...500mA, 24...240V AC DC

CURRENT RELAY 250V 5AMP RM35

SQDRM35JA31MW RM35JA31MW 3389119405218
197.72 / EA
http://schema.org/OutOfStock
  • Country of Origin: Indonesia
  • Warranty Length: 18 mth
This Harmony RM35-JA relay allows monitoring of current control in single phase networks. This modular multi function single phase current control relay is ideal for monitoring of electrical values in industrial and building control panels. It applies to
QTY
  • Product Description
  • Features
  • Specifications
This Harmony RM35-JA relay allows monitoring of current control in single phase networks. This modular multi function single phase current control relay is ideal for monitoring of electrical values in industrial and building control panels. It applies to
  • Insulation Resistance
    • > 500 MOhm 500 V DC between supply and relay output IEC 60255-5
    • > 500 MOhm 500 V DC between supply and relay output IEC 60255-
  • US Rated Supply Voltage
    • 24...240 V AC/DC 50/60 Hz, non self-powered
  • Connections Terminals
    • screw terminals, 1 x 0.5...1 x 4 mm² AWG 20...AWG 11) solid without cable end
    • screw terminals, 1 x
  • Overvoltage Category
    • III conforming to IEC 60664-1
  • Mounting Support
    • 35 mm symmetrical DIN rail conforming to IEC 60715
  • Supply Voltage Limits
    • 20.4-264 V AC/DC
  • IP Degree Of Protection
    • IP20 IEC 60529 terminals)
    • IP30 IEC 60529 casing)
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Carbon Footprint Of The Installation Phase A5
    • 0 kg CO2 eq.
    • 0
  • Carbon Footprint Of The End Of Life Phase C1 To C4
    • 0.0091526182
    • 0 kg CO2 eq.
  • Operating Position
    • any position without derating
  • Maximum Power Consumption In VA
    • 3.5 VA AC
  • Maximum Switching Voltage
    • 250 V AC
  • Dielectric Test Voltage
    • 2 kV AC 50 Hz, 1 min IEC 60255-5
    • 2 kV AC 50 Hz, 1 min IEC 60664-1
    • 2 kV AC 50 Hz, 1 min IE
  • Maximum Measuring Cycle
    • 30 ms measurement cycle as true rms value
  • Carbon Footprint Of The Manufacturing Phase A1 To A3
    • 2 kg CO2 eq.
    • 2.4586778537
  • Maximum Switching Current
    • 5 A AC
  • UI Rated Insulation Voltage
    • 250 V IEC 60664-1
  • Time Delay Type
    • adjustable 0.3...30 s, 0 + 10 % Tt- time delay upon fault
    • adjustable 1...20 s, 0
  • Measurement Range
    • 2...500 mA AC/DC E2-M terminals
  • Reset Time
    • 1500 ms time delay
  • Vibration Resistance
    • 0.35 mm (f= 5-57.6 Hz) conforming to IEC 60068-2-6
    • 1 gn (f= 57.6-150 Hz) conforming to IEC 60255-21-1
  • Market Segmentation
    • Commercial
    • Industrial
  • Persona Type Names
    • Charge Point Operator
    • End User
    • Contractor
    • Original Equipment Manufacturer
    • OEM - Control Panelbuilder
    • Panel Builder
    • Electrician
    • System Integrator
    • IT Channel Partner
  • Measurement Error
    • 0.05 %/°C with temperature variation
    • 1 by volt over the whole range with voltage variation
  • Carbon Footprint Of The Use Phase B2 B3 B4 B6
    • 40 kg CO2 eq.
    • 39.7498772978
  • Electromagnetic Compatibility
    • emission standard for industrial environments conforming to IEC 61000-6-4
    • emission standard for residential, commercial and light-industrial environments conforming to IEC 61000-6-
  • Hysteresis
    • 5-50 % threshold setting
  • Relative Humidity
    • 95-95 % 55-55 °C IEC 60068-2-30
  • Persona Type Ids
    • BM9
    • EU
    • LC
    • OM
    • OM8
    • PB
    • SC
    • SI
    • VR
  • Polarity
    • no DC
  • Carbon Footprint Of The Distribution Phase A4
    • 0.0238468659
    • 0 kg CO2 eq.
  • Tightening Torque
    • 0.6-1 N.m IEC 60947-1
  • Minimum Switching Current
    • 10 mA 5 V DC
  • Non Dissipating Shock Wave
    • 4 kV IEC 60255-5
    • 4 kV IEC 60664-1
    • 4 kV IEC 61000-4-5
  • Repeat Accuracy
    • +/- 0.5 % input and measurement circuit
    • +/- 2 % time delay
  • Utilisation Category
    • AC-12 IEC 60947-5-1
    • AC-13 IEC 60947-5-1
    • AC-14 IEC 60947-5-1
    • AC-15 IEC 60947-5-1
    • DC-12 IEC 60947-5-1
    • DC-13 IEC 60947-5-1
    • DC-14 IEC 6094
  • Resistance Across Terminals
    • 1 Ohm E2-M terminals
    • 5 Ohm E1-M terminals
    • 0.2 Ohm E3-M terminals
  • Market Segmentation Id
    • COMMERCIAL
    • INDUSTRIAL
  • Operating Rate
    • <= 360 operations/hour full load
  • Shock Resistance
    • 15 gn 11 ms IEC 60255-21-1
  • Maximum Power Consumption In W
    • 0.6 W DC
  • Local Signalling
    • LED (green) for power ON
    • LED (yellow) for relay ON
  • Assets
    • CAD : https://download.schneider-electric.com/files?p_Doc_Ref=MCADID0001777_3D-CAD
  • Complementary Attributes
    • Control Circuit Frequency : 40...70 Hz +/- 10 %
  • Important Information Attributes
    • Local Data Status : Publishable
    • Local Publishable Date : 8/7/2025
    • HTML Description : Current Control Relay RM35-J - Range 2..500 mA
    • Manufacturer : Schneider Electric
    • Manufacturing Carbon Footprint : 2.458677854
    • Distribution Carbon Footprint : 0.023846866
    • Installation Carbon Footprint : 0
    • Use Carbon Footprint : 39.7498773
    • End Of Life Carbon Footprint : 0.009152618
    • Legacy WEEE Scope : Out
    • WEEE Product Category : 5
    • Scope Perimeter : At least in Europe
    • EOLI Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI1601004EN
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • ROHS EUR In Scope : No
    • ROHS EUR Status : Compliant with Exemptions
    • ROHS EUR Conformity Date : 1918
    • ROHS EUR Full Compliance Status : Pro-active compliance (Product out of EU RoHS legal scope)
    • ROHS EUR Full Compliance Status Id : PRO_ACTIVE_COMPLIANCE
    • China ROHS In Scope : Yes
    • China ROHS Label : 5
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Return Indicator : Y
    • WD Status : 1 - GSC certified
    • Tier Id : 1
    • Tier : 1
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Compatibility Code : RM3
    • Functionality : overcurrent or undercurrent in window mode
    • Housing Material : self-extinguishing plastic
    • Package Weight Lbs : 138.000 g
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Or Component Type : current control relay
    • Range Of Product : Harmony Control Relays
    • Relay Name : RM35JA
    • Returnability : Yes
    • Sustainable Packaging : Yes
    • Total Lifecycle Carbon Footprint : 42 kg CO2 eq.
    • Carbon Footprint Kg Co2 Eq Total Life Cycle : 42.24155464
    • Relationship Type : cross-selling relationship
    • Pep Code : ENVPEP1601004EN
    • Pep Verification Date : 1/1/2016
    • PCR Version : PCR-ed2
    • Product Weight In G : 138
    • Reference Lifetime In Y : 10
    • Energy Consumption On Product Lifetime In Kwh : 67.2768
    • Energy Model Installation A5 : ELCD_Electricity_mix_<1kV_EU-27__ELCD-0089
    • Energy Model Use B6 : ELCD_Electricity_mix_<1kV_EU-27__ELCD-0089
    • Energy Model End Of Life C1 C4 : ELCD_Electricity_mix_<1kV_EU-27__ELCD-0089
    • Hazardous Waste Disposed Of Kg Total Life Cycle : 0.049157252
    • Hazardous Waste Disposed Of Kg Manufacturing A1 A3 : 0.042337957
    • Hazardous Waste Disposed Of Kg Distribution A4 : 2.95E-08
    • Hazardous Waste Disposed Of Kg Installation A5 : 0
    • Hazardous Waste Disposed Of Kg Operational Energy Use B6 : 0.006819255
    • Hazardous Waste Disposed Of Kg End Of Life C1 C4 : 1.13E-08
    • Ozone Depletion Kg Equivalent Cfc 11 Total Life Cycle : 9.3879E-06
    • Ozone Depletion Kg Equivalent Cfc 11 Manufacturing A1 A3 : 3.319E-07
    • Ozone Depletion Kg Equivalent Cfc 11 Distribution A4 : 0
    • Ozone Depletion Kg Equivalent Cfc 11 Installation A5 : 0
    • Ozone Depletion Kg Equivalent Cfc 11 Operational Energy Use B6 : 0.000009056
    • Ozone Depletion Kg Equivalent Cfc 11 End Of Life C1 C4 : 0
    • Air Pollution M3 Total Life Cycle : 10732362.95
    • Air Pollution M3 Manufacturing A1 A3 : 768974.569
    • Air Pollution M3 Distribution A4 : 6651.534202
    • Air Pollution M3 Installation A5 : 0
    • Air Pollution M3 Operational Energy Use B6 : 9954062.177
    • Air Pollution M3 End Of Life C1 C4 : 2674.667363
    • Water Pollution M3 Total Life Cycle : 18.40092529
    • Water Pollution M3 Manufacturing A1 A3 : 0.6896587
    • Water Pollution M3 Distribution A4 : 0.010173573
    • Water Pollution M3 Installation A5 : 0
    • Water Pollution M3 Operational Energy Use B6 : 17.69718197
    • Water Pollution M3 End Of Life C1 C4 : 0.003911042
    • Photochemical Ozone Formation Kg Equivalent C2h4 Total Life Cycle : 0.003210814
    • Water Eutrophication Kg Equivalent P04 3 Total Life Cycle : 0.000591873
    • Global Warming Kg Equivalent Co2 Total Life Cycle : 42.24155464
    • Global Warming Kg Equivalent Co2 Manufacturing A1 A3 : 2.458677854
    • Global Warming Kg Equivalent Co2 Distribution A4 : 0.023846866
    • Global Warming Kg Equivalent Co2 Installation A5 : 0
    • Global Warming Kg Equivalent Co2 Operational Energy Use B6 : 39.7498773
    • Global Warming Kg Equivalent Co2 End Of Life C1 C4 : 0.009152618
    • Photochemical Ozone Formation Kg Equivalent C2h4 Manufacturing A1 A3 : 0.000746215
    • Photochemical Ozone Formation Kg Equivalent C2h4 Distribution A4 : 0.000006146
    • Photochemical Ozone Formation Kg Equivalent C2h4 Installation A5 : 0
    • Photochemical Ozone Formation Kg Equivalent C2h4 Operational Energy Use B6 : 0.002456174
    • Photochemical Ozone Formation Kg Equivalent C2h4 End Of Life C1 C4 : 2.2781E-06
    • Water Eutrophication Kg Equivalent P04 3 Manufacturing A1 A3 : 0.000213945
    • Water Eutrophication Kg Equivalent P04 3 Distribution A4 : 4.42E-08
    • Water Eutrophication Kg Equivalent P04 3 Installation A5 : 0
    • Water Eutrophication Kg Equivalent P04 3 Operational Energy Use B6 : 0.000377867
    • Water Eutrophication Kg Equivalent P04 3 End Of Life C1 C4 : 0.000000017
    • Warranty In Months : 18
  • General Attributes
    • Product Or Component Type : current control relay
    • Range Of Product : Harmony Control Relays
  • Output Attributes
    • Output Contacts : 2 C/O
  • Environment Attributes
    • China ROHS url : https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=exportPdfRoHSChina&pid=648360&lang=en-us
    • Take Back : No
    • Recycled Metal Content At Cr Level : 0%
    • China ROHS Regulation : X
    • Mercury Free : Yes
    • Carbon Footprint : 42.24155464
    • Ambient Air Temperature For Operation : -20-50 °C
    • Circularity Profile : ENVEOLI1601004EN
    • Environmental Disclosure : ENVPEP1601004EN
    • EU ROHS Directive : Pro-active compliance (Product out of EU RoHS legal scope)
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP1601004EN
    • Pep Verification Date : 1/1/2016
    • PCR Version : PCR-ed2
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Specifications
    • Country of Origin : Indonesia