safety module, Modicon TM3, 1 function, Cat 3 PL d, SIL CL2, spring, 24V DC

MODULE TM3 SAFETY CAT. 3, SPR

SQDTM3SAC5RG TM3SAC5RG 3606485392981
381.45 / EA
http://schema.org/OutOfStock
  • Depth: 73 mm
  • Output Voltage: 10 V
This TM3 safety expansion module monitors emergency shutdown pushbuttons and limit switches to conform to PLd / Category 3. It meets the requirements of PL d/Category 3 conforming to EN/ISO 13849-1 and SILCL 2 conforming to EN/IEC 62061. It has a module locking latch, 2 TM3 bus connectors designed to provide continuity of the link between connected modules, a symmetrical rail locking clip, display block for the module channels and diagnostics. It completes your Modicon M221, M241 or M251 PLC configuration with a dedicated safety I/O, without the need to use a complete safety controller. It has removable terminals for easier and better control wires tightening, thus improving installation reliability. It has spring terminals for fast and reliable wiring of safety circuits.
QTY
  • Product Description
  • Features
  • Specifications
This TM3 safety expansion module monitors emergency shutdown pushbuttons and limit switches to conform to PLd / Category 3. It meets the requirements of PL d/Category 3 conforming to EN/ISO 13849-1 and SILCL 2 conforming to EN/IEC 62061. It has a module locking latch, 2 TM3 bus connectors designed to provide continuity of the link between connected modules, a symmetrical rail locking clip, display block for the module channels and diagnostics. It completes your Modicon M221, M241 or M251 PLC configuration with a dedicated safety I/O, without the need to use a complete safety controller. It has removable terminals for easier and better control wires tightening, thus improving installation reliability. It has spring terminals for fast and reliable wiring of safety circuits.
  • Features
    • Make any Modicon M2xx PLC as safety controller using a functional safety I/O modules
    • Modularity and easness of installation
    • Large choice of I/O system to enhance the capabilities of Modicon M2xx plc
    • Removable terminal BLOCKS for better control wires tightening
    • Spring terminals for fast and reliable wiring of safety circuits
    • Modicon TM3 is an EcoStruxure Machine I/O system
    • Modicon TM3 expansion modules are designed with a simple interlocking assembly mechanism
    • The TM3 bus transfers data and power supply between I/O modules and the PLC
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Conformance Attributes
    • Product Certifications : UL 61010-2-201, CSA 61010-2-201 (pending), TÜV, EAC, CSA Haz Loc Class 1 Division 2 (pending), ANSI Haz Loc Class 1 Division 2 (pending), RCM
    • Standards : ISO 13849-1:2008, ISO 13849-2:2012, IEC 62061:2005, IEC 61508:2010, IEC 60947-5-1:2010, IEC 61131-2:2007, IEC 60204-1:2005, IEC 60204-1:2009/A1, IEC 61010-1:2010, EN 50581:2012, IEC 60947-1, IEC 60204-1, ISO 13850, EN 1088/ISO 14119, IEC 60947-5-1
  • Complementary Attributes
    • Maximum Switching Voltage : 230 V AC-15 50 Hz relay instantaneous opening), 24 V DC-13 relay instantaneous opening)
    • Maximum Cable Distance Between Devices : 30 m
    • Maximum Response Time On Input Open : 40 ms
    • Minimum Output Current : 10 mA relay output
  • Important Information Attributes
    • Persona Type Ids : EU, OM, OM8
    • Persona Type Names : End User, Original Equipment Manufacturer, OEM - Control Panelbuilder
    • Associated Fuse Rating : 4 A gG or gL relay output IEC 60947-5-1, 6 A fast blow relay output IEC 60947-5-1
    • Electromagnetic Compatibility : electrostatic discharge immunity test - test level: 8 kV (air discharge) conforming to IEC 61000-4-2, electrostatic discharge immunity test - test level: 6 kV (contact discharge) conforming to IEC 61000-4-2, susceptibility to electromagnetic fields - test level: 10 V/m (80 MHz to 1 GHz) conforming to IEC 61000-4-3, susceptibility to electromagnetic fields - test level: 3 V/m (1.4 GHz...2 GHz) conforming to IEC 61000-4-3, susceptibility to electromagnetic fields - test level: 1 V/m (2 GHz...3 GHz) conforming to IEC 61000-4-3, magnetic field at power frequency - test level: 30 A/m (50...60 Hz) conforming to IEC 61000-4-8, electrical fast transient/burst immunity test - test level: 3 kV (power lines (DC)) conforming to IEC 61000-4-4, electrical fast transient/burst immunity test - test level: 2 kV (I/O) conforming to IEC 61000-4-4, 1.2/50 µs shock waves immunity test - test level: 1 kV (power lines (DC)) conforming to IEC 61000-4-5, conducted RF disturbances - test level: 10 V (0.15...80 MHz) conforming to IEC 61000-4-6, radiated emission - test level: 40 dBµV/m class A (24 V) conforming to IEC 55011, radiated emission - test level: 47 dBµV/m class A (24 V) conforming to IEC 55011
    • Electromagnetic Emission : radiated emissions 50 dBµV/m class A 24 V DC)30-230 Hz IEC 61131-3, radiated emissions 57 dBµV/m class A 24 V DC)230-1000 Hz IEC 61131-3
    • Function Of Module : emergency stop monitoring 1-channel wiring, emergency stop monitoring 2-channel wiring, monitoring of a movable guard with 2 switches and automatic start
    • Marking : CSA, EAC, CE, RCM, UL, TÜV, EFUP 10
    • Mounting Support : top hat type TH35-7.5 rail IEC 60715, top hat type TH35-15 rail IEC 60715, wall mount using attached fasteners
    • Power Consumption In W : 0.2 W 5 V DC, 3.6 W 24 V DC
    • Resistance To Electromagnetic Fields : 10 V/m 80 MHz...1 GHz IEC 61000-4-3, 3 V/m 1.4 GHz...2 GHz IEC 61000-4-3, 1 V/m 2 GHz...3 GHz IEC 61000-4-3
    • Resistance To Electrostatic Discharge : 8 kV in air IEC 61000-4-2, 6 kV on contact IEC 61000-4-2
    • Resistance To Fast Transients : 3 kV power lines (DC) DC)IEC 61000-4-4, 2 kV I/O linesIEC 61000-4-4
    • Safety Level : can reach PL d/category 3 ISO 13849-1 2008, can reach PL d/category 3 ISO 13849-2 2012, can reach SILCL 2 IEC 62061 2005, can reach SIL 2 IEC 61508 2010
    • Vibration Resistance : +/- 3.5 mm (f= 5-150 Hz) conforming to IEC 60068-2-6, +/- 3.5 mm (f= 5-150 Hz) conforming to IEC 60068-2-6, +/- 3.5 mm (f= 5-150 Hz) conforming to IEC 60068-2-6, +/- 3.5 mm (f= 5-150 Hz) conforming to IEC 60068-2-6, +/- 3.5 mm (f= 5-150 Hz) conforming to IEC 60068-2-6, +/- 3.5 mm (f= 5-150 Hz) conforming to IEC 60068-2-6
    • Carbon Footprint Of The Distribution Phase A4 : 0.0298042592, 0 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 0.1 kg CO2 eq., 0.1372649737
    • Carbon Footprint Of The Installation Phase A5 : 0.0003966161, 0 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 3 kg CO2 eq., 3.3879730298
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 155 kg CO2 eq., 154.51
    • Connections Terminals : captive spring terminals, removable terminal block 1 x 0.2...1 x 2.5 mm² flexible without cable end 13-14, 23-24, 33-34, captive spring terminals, removable terminal block 1 x 0.2...1 x 2.5 mm² solid without cable end 13-14, 23-24, 33-34, captive spring terminals, removable terminal block 1 x 0.25...1 x 2.5 mm² flexible with cable end, with bezel 13-14, 23-24, 33-34, captive spring terminals, removable terminal block 1 x 0.25...1 x 2.5 mm² flexible with cable end, without bezel 13-14, 23-24, 33-34, captive spring terminals, removable terminal block 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel 13-14, 23-24, 33-34, captive spring terminals, removable terminal block 1 x 0.14...1 x 1.5 mm² flexible without cable end other terminals, captive spring terminals, removable terminal block 1 x 0.25...1 x 0.5 mm² flexible with cable end, with bezel other terminals, captive spring terminals, removable terminal block 1 x 0.25...1 x 1.5 mm² flexible with cable end, without bezel other terminals
    • Safety Reliability Data : DC = 95 % ISO 13849-1, SFF = 95 % IEC 61508-1, HFT = 1 IEC 61508-1, type = A IEC 61508-1, PFHd = 5E-9 1/h IEC 61508-1, PFHd = 30E-9 1/h IEC 61508-1, MTTFd = 500 years ISO 13849-1, MTTFd = 85 years ISO 13849-1
    • Connections Terminals3 : captive spring terminals, removable terminal block 1 x 0.2...1 x 2.5 mm² flexible without cable end 13-14, 23-24, 33-34, captive spring terminals, removable terminal block 1 x 0.2...1 x 2.5 mm² solid without cable end 13-14, 23-24, 33-34, captive spring terminals, removable terminal block 1 x 0.25...1 x 2.5 mm² flexible with cable end, with bezel 13-14, 23-24, 33-34, captive spring terminals, removable terminal block 1 x 0.25...1 x 2.5 mm² flexible with cable end, without bezel 13-14, 23-24, 33-34, captive spring terminals, removable terminal block 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel 13-14, 23-24, 33-34, captive spring terminals, removable terminal block 1 x 0.14...1 x 1.5 mm² flexible without cable end other terminals, captive spring terminals, removable terminal block 1 x 0.14...1 x 1.5 mm² solid without cable end other terminals, captive spring terminals, removable terminal block 1 x 0.25...1 x 0.5 mm² flexible with cable end, with bezel other terminals, captive spring terminals, removable terminal block 1 x 0.25...1 x 1.5 mm² flexible with cable end, without bezel other terminals
    • Local Data Status : Publishable
    • Local Publishable Date : 2026-01-12
    • Device Type : PLC System - PLC Component
    • Serviceability : No
    • Traceability : Yes
    • Field Service Division : IDIBS
    • Legacy WEEE Scope : In
    • Scope Perimeter : At least in Europe
    • EOLI Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI1403010EN
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • ROHS EUR In Scope : No
    • ROHS EUR Status : Compliant with Exemptions
    • ROHS EUR Full Compliance Status : Pro-active compliance (Product out of EU RoHS legal scope)
    • ROHS EUR Full Compliance Status Id : PRO_ACTIVE_COMPLIANCE
    • China ROHS In Scope : Yes
    • Green Premium Status For Reporting : Green Premium product
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Return Indicator : N
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Market Segmentation Id : INDUSTRIAL
    • Market Segmentation : Industrial
    • Current Consumption : 100 mA 24 V DC external supply
    • Device Short Name : TM3SAC
    • Electrical Connection : spring terminal
    • Local Signalling : 6 LEDs (green/red) for user
    • Mechanical Robustness : bumps 6 ms 300 shocks 25 gn) IEC 60068-2-27
    • Package Weight Lbs : 269.000 g
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Or Component Type : safety module
    • Range Of Product : Modicon TM3 Safety
    • Returnability : No
    • Shock Resistance : 15 gn 11 ms IEC 60068-2-27
    • Sustainable Packaging : No
    • Total Lifecycle Carbon Footprint : 158 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Ith Conventional Free Air Thermal Current2 : 18 A
    • Uc Control Circuit Voltage2 : 24 V DC
    • Ui Rated Insulation Voltage2 : 300 V 2)IEC 60647-5-1
    • Uimp Rated Impulse Withstand Voltage2 : 4 kV III IEC 60647-5-1
    • Us Rated Supply Voltage2 : 24 V - 15...20 % DC
    • Medium Desc : safety module, Modicon TM3, 1 function, Cat 3 PL d, SIL CL2, spring, 24V DC
    • Stocking Flag : Y
    • Product Kit Identifier : N
    • Pep Code : ENVPEP1403010EN
    • Database Version : 2016-11
    • Pep Verification Date : 2018-11-01
    • Pcr Version : PCR-ed3-EN-2015 04 02
    • Type Of Verification For The Pep : Independent external review
    • Data Source : extrapolated product
    • Functional Unit Description : to enhance safety related functionality of the M221, M41 and M251 controllers 100% of the time for 10 years at 3.6W
    • Functional Unit Unit : unité (unit)
    • Energy Model Manufacturing A1 A3 2 : Energy model used: Germany
    • Energy Model Installation A5 2 : Electricity mix; AC; < 1kV; EU-27
    • Energy Model Use B6 2 : Electricity mix; AC; < 1kV; EU-27
    • Energy Model End Of Life C1 C4 2 : Electricity mix; AC; < 1kV; EU-27
    • Number Of Safety Circuits : 3 NO relay instantaneous opening
    • Resistance To Conducted Disturbances : 10 V 0.15...80 MHz IEC 61000-4-6
    • Resistance To Magnetic Fields : 30 A/m 50/60 Hz IEC 61000-4-8
    • Safety Module Application : for emergency stop and switch monitoring
    • Global Commercial Status : Commercialised
    • Uc Control Circuit Voltage5 : 24 V DC
    • Ui Rated Insulation Voltage5 : 300 V 2)IEC 60647-5-1
    • Uimp Rated Impulse Withstand Voltage5 : 4 kV III IEC 60647-5-1
    • Us Rated Supply Voltage5 : 24 V - 15...20 % DC
  • Environment Attributes Main
    • Take Back : No, Nej
    • Ambient Air Temperature For Operation : -10-55 °C horizontal installation, -10-55 °C horizontal installation, -10-55 °C horizontal installation, -10-55 °C horizontal installation
    • EU ROHS Directive : Compliant By Exemption , Pro-active compliance (Product out of EU RoHS legal scope)
    • Relative Humidity : 10-95 %, without condensation in operation), 10-95 %, without condensation in storage)
    • ROHS Exemption Information : Yes
    • Recycled Metal Content At Cr Level : 0 %
    • China ROHS Regulation : X
    • Mercury Free : Yes
    • Carbon Footprint : 158.0654388788
    • Ambient Air Temperature For Storage : -25-70 °C
    • Circularity Profile : ENVEOLI1403010EN
    • Environmental Disclosure : ENVPEP1403010EN
    • IP Degree Of Protection : IP20 terminals)IEC 60529
    • Operating Altitude : 0...6561.68 ft (0...2000 m)
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Storage Altitude : 0-3000 m
    • Pep Code : ENVPEP1403010EN
    • Pep Verification Date : 2018-11-01
    • Pcr Version : PCR-ed3-EN-2015 04 02
    • Type Of Verification For The Pep : Independent external review
  • General Attributes
    • Product Or Component Type : safety module
    • Range Of Product : Modicon TM3 Safety
  • Output Attributes
    • Output Type : relay instantaneous opening, 3 NO, potential free
    • Output Voltage : 10 V relay output
    • Minimum Output Current : 10 mA relay output
    • Output Thermal Current : 6 A per relay relay output
  • Surge Protection And Filtering Attributes
    • Surge Withstand : 1 kV power lines (DC) differential mode IEC 61000-4-5 DC, 1 kV power lines (DC) common mode IEC 61000-4-5 DC
  • Input Attributes
    • Input Protection Type : internal, electronic
    • Maximum Response Time On Input Open : 40 ms
    • Synchronisation Time Between Inputs : unlimited
  • Specifications
    • Depth : 73 mm