SQUARE D

Mini circuit breaker, E-Frame, 40A, 2 pole, 480Y/277VAC, 65kA max, bolt on, shunt trip [TAA]

MINI CIRCUIT BREAKER, E-FRAME,

SQDEGB24040SA EGB24040SA SQDEGB24040SA
0.00 / EA
http://schema.org/OutOfStock
  • Module Type: E-Frame
  • Warranty Length: 18 mth
E-Frame Breaker are Lighting Panelboard Circuit breakers that are proven effective and reliable which provide a wide variety or robust features that are use specifically in Square D NF Panelboards. This range of breaker is ideally designed to offer superior overload and short circuit protection. All E-Frame breakers have a thermal-magnetic trip unit as well as signal indicator that will indicate when a trip has occur. Mounting bolts are used to hold these breakers in place. This E-Frame breaker is 40A, 2 pole, and has an operating voltage of 480Y/277 VAC. It also provides a 65 kA max interrupt rating at 120 VAC. This device has a hold current of 630A which is the maximum current the breaker can be held to ensure it will trip and a trip current of 1800A which is the current value when the breaker is guaranteed to trip. Many accessories are available for this breaker. This one includes a shunt trip. This breaker was calibrated for 40 degrees C. This product is UL Listed as High Intensity Discharge. HACR rated.
QTY
  • Product Description
  • Features
  • Specifications
E-Frame Breaker are Lighting Panelboard Circuit breakers that are proven effective and reliable which provide a wide variety or robust features that are use specifically in Square D NF Panelboards. This range of breaker is ideally designed to offer superior overload and short circuit protection. All E-Frame breakers have a thermal-magnetic trip unit as well as signal indicator that will indicate when a trip has occur. Mounting bolts are used to hold these breakers in place. This E-Frame breaker is 40A, 2 pole, and has an operating voltage of 480Y/277 VAC. It also provides a 65 kA max interrupt rating at 120 VAC. This device has a hold current of 630A which is the maximum current the breaker can be held to ensure it will trip and a trip current of 1800A which is the current value when the breaker is guaranteed to trip. Many accessories are available for this breaker. This one includes a shunt trip. This breaker was calibrated for 40 degrees C. This product is UL Listed as High Intensity Discharge. HACR rated.
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Complementary Attributes
    • UE Rated Operational Voltage : 480Y/277 V AC, 480Y/277 V AC
  • Environment Attributes Additional
    • Energy Model Manufacturing A1 A3 : Electricity Mix; Low voltage; 2020; Mexico, MX
    • Energy Model Installation A5 : No energy used
    • Energy Model Use B6 : Electricity Mix; Low voltage; 2020; United States, US
    • Energy Model End Of Life C1 C4 : Global, European and French datasets are used.
    • Acidification Ap Mole Of H Equiv Total Life Cycle : 0.0796254072415213
    • Acidification Ap Mole Of H Equiv Manufacturing A1 A3 : 0.06804510239984903
    • Acidification Ap Mole Of H Equiv Distribution A4 : 0.0007704901400757248
    • Acidification Ap Mole Of H Equiv Installation A5 : 0.0005669117632821643
    • Acidification Ap Mole Of H Equiv Maintenance B2 : 0
    • Acidification Ap Mole Of H Equiv Repair B3 : 0
    • Acidification Ap Mole Of H Equiv Replacement B4 : 0
    • Acidification Ap Mole Of H Equiv Operational Energy Use B6 : 0.006092917380671635
    • Acidification Ap Mole Of H Equiv End Of Life C1 C4 : 0.004149985557642746
    • Acidification Ap Mole Of H Equiv Benefits Loads Beyond System Boundaries D : -0.029232613745350397
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C Total Life Cycle : 0
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C Manufacturing A1 A3 : 0
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C Distribution A4 : 0
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C Installation A5 : 0
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C Maintenance B2 : 0
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C Repair B3 : 0
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C Replacement B4 : 0
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C Operational Energy Use B6 : 0
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C End Of Life C1 C4 : 0
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C BLB SysBound D : 0
    • Biogenic Carbon Content Of The Product Kg Of C Total Life Cycle : 0
    • Biogenic Carbon Content Of The Product Kg Of C Manufacturing A1 A3 : 0
    • Biogenic Carbon Content Of The Product Kg Of C Distribution A4 : 0
    • Biogenic Carbon Content Of The Product Kg Of C Installation A5 : 0
    • Biogenic Carbon Content Of The Product Kg Of C Maintenance B2 : 0
    • Biogenic Carbon Content Of The Product Kg Of C Repair B3 : 0
    • Biogenic Carbon Content Of The Product Kg Of C Replacement B4 : 0
    • Biogenic Carbon Content Of The Product Kg Of C Operational Energy Use B6 : 0
    • Biogenic Carbon Content Of The Product Kg Of C End Of Life C1 C4 : 0
    • Biogenic Carbon Content Of The Product Kg Of C Benefits Loads Beyond System Boundaries D : 0
    • Climate Change Biogenics Kg Co2 Eq Total Life Cycle : 0.20734201064162172
    • Climate Change Biogenics Kg Co2 Eq Manufacturing A1 A3 : -0.5048757336017836
    • Climate Change Biogenics Kg Co2 Eq Distribution A4 : 0.00000226833112123345
    • Climate Change Biogenics Kg Co2 Eq Installation A5 : 0.43255360616234795
    • Climate Change Biogenics Kg Co2 Eq Maintenance B2 : 0
    • Climate Change Biogenics Kg Co2 Eq Repair B3 : 0
    • Climate Change Biogenics Kg Co2 Eq Replacement B4 : 0
    • Climate Change Biogenics Kg Co2 Eq Operational Energy Use B6 : 0.006765223401187115
    • Climate Change Biogenics Kg Co2 Eq End Of Life C1 C4 : 0.272896646348749
    • Climate Change Biogenics Kg Co2 Eq Benefits Loads Beyond System Boundaries D : -0.06490514275708652
    • Climate Change Fossil Fuels Kg Co2 Eq Total Life Cycle : 14.294072934017786
    • Climate Change Fossil Fuels Kg Co2 Eq Manufacturing A1 A3 : 10.460201392573586
    • Climate Change Fossil Fuels Kg Co2 Eq Distribution A4 : 0.4464683912892581
    • Climate Change Fossil Fuels Kg Co2 Eq Installation A5 : 0.09390135503942942
    • Climate Change Fossil Fuels Kg Co2 Eq Maintenance B2 : 0
    • Climate Change Fossil Fuels Kg Co2 Eq Repair B3 : 0
    • Climate Change Fossil Fuels Kg Co2 Eq Replacement B4 : 0
    • Climate Change Fossil Fuels Kg Co2 Eq Operational Energy Use B6 : 1.395057010627783
    • Climate Change Fossil Fuels Kg Co2 Eq End Of Life C1 C4 : 1.89844478448773
    • Climate Change Fossil Fuels Kg Co2 Eq Benefits Loads Beyond System Boundaries D : -0.9942974536215117
    • Climate Change Total Kg Co2 Eq Total Life Cycle : 14.501418077493437
    • Climate Change Total Kg Co2 Eq Manufacturing A1 A3 : 9.955327776428094
    • Climate Change Total Kg Co2 Eq Distribution A4 : 0.44647149800033886
    • Climate Change Total Kg Co2 Eq Installation A5 : 0.5264549621353984
    • Climate Change Total Kg Co2 Eq Maintenance B2 : 0
    • Climate Change Total Kg Co2 Eq Repair B3 : 0
    • Climate Change Total Kg Co2 Eq Replacement B4 : 0
    • Climate Change Total Kg Co2 Eq Operational Energy Use B6 : 1.40182223402897
    • Climate Change Total Kg Co2 Eq End Of Life C1 C4 : 2.171341606900636
    • Climate Change Total Kg Co2 Eq Benefits Loads Beyond System Boundaries D : -1.0592025963785983
    • Components For Re Use Kg Total Life Cycle : 0
    • Components For Re Use Kg Manufacturing A1 A3 : 0
    • Components For Re Use Kg Distribution A4 : 0
    • Components For Re Use Kg Installation A5 : 0
    • Components For Re Use Kg Maintenance B2 : 0
    • Components For Re Use Kg Repair B3 : 0
    • Components For Re Use Kg Replacement B4 : 0
    • Components For Re Use Kg Operational Energy Use B6 : 0
    • Components For Re Use Kg End Of Life C1 C4 : 0
    • Components For Re Use Kg Benefits Loads Beyond System Boundaries D : 0
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Total Life Cycle : 0.02193057111682889
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Manufacturing A1 A3 : 0.02192977656961959
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Distribution A4 : 0.00000036586008461953
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Installation A5 : 0.00000001348451079416
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Maintenance B2 : 0
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Repair B3 : 0
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Replacement B4 : 0
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Operational Energy Use B6 : 0.00000032982091699664
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb End Of Life C1 C4 : 0.00000008538169689051
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb BLB SysBound D : -0.00047465976598522105
    • Depletion Of Abiotic Resources Fossil Fuels Mj Total Life Cycle : 245.94098492578658
    • Depletion Of Abiotic Resources Fossil Fuels Mj Manufacturing A1 A3 : 195.02893752583782
    • Depletion Of Abiotic Resources Fossil Fuels Mj Distribution A4 : 8.184605685497305
    • Depletion Of Abiotic Resources Fossil Fuels Mj Installation A5 : 1.7398387520209562
    • Depletion Of Abiotic Resources Fossil Fuels Mj Maintenance B2 : 0
    • Depletion Of Abiotic Resources Fossil Fuels Mj Repair B3 : 0
    • Depletion Of Abiotic Resources Fossil Fuels Mj Replacement B4 : 0
    • Depletion Of Abiotic Resources Fossil Fuels Mj Operational Energy Use B6 : 30.4138744356491
    • Depletion Of Abiotic Resources Fossil Fuels Mj End Of Life C1 C4 : 10.573728526781414
    • Depletion Of Abiotic Resources Fossil Fuels Mj Benefits Loads Beyond System Boundaries D : -21.603937350619596
    • Ecotoxicity Fresh Water Ctue Total Life Cycle : 7883.629591040089
    • Ecotoxicity Fresh Water Ctue Manufacturing A1 A3 : 7832.899928109751
    • Ecotoxicity Fresh Water Ctue Distribution A4 : 16.15643200409891
    • Ecotoxicity Fresh Water Ctue Installation A5 : 2.3274006518805876
    • Ecotoxicity Fresh Water Ctue Maintenance B2 : 0
    • Ecotoxicity Fresh Water Ctue Repair B3 : 0
    • Ecotoxicity Fresh Water Ctue Replacement B4 : 0
    • Ecotoxicity Fresh Water Ctue Operational Energy Use B6 : 1.670117629527107
    • Ecotoxicity Fresh Water Ctue End Of Life C1 C4 : 30.57571264483062
    • Ecotoxicity Fresh Water Ctue Benefits Loads Beyond System Boundaries D : -7.646200106265542
    • Emission Of Fine Particles Incidence Of Diseases Total Life Cycle : 0.00000094948076823967
    • Emission Of Fine Particles Incidence Of Diseases Manufacturing A1 A3 : 0.00000086465480526333
    • Emission Of Fine Particles Incidence Of Diseases Distribution A4 : 0.00000000685260760783
    • Emission Of Fine Particles Incidence Of Diseases Installation A5 : 0.000000003952412095
    • Emission Of Fine Particles Incidence Of Diseases Maintenance B2 : 0
    • Emission Of Fine Particles Incidence Of Diseases Repair B3 : 0
    • Emission Of Fine Particles Incidence Of Diseases Replacement B4 : 0
    • Emission Of Fine Particles Incidence Of Diseases Operational Energy Use B6 : 0.0000000451329743787
    • Emission Of Fine Particles Incidence Of Diseases End Of Life C1 C4 : 0.0000000288879688948
    • Emission Of Fine Particles Incidence Of Diseases BLB SysBound D : -0.0000005429528724367
    • Exported Energy Mj By Energy Vector Total Life Cycle : 0
    • Exported Energy Mj By Energy Vector Manufacturing A1 A3 : 0
    • Exported Energy Mj By Energy Vector Distribution A4 : 0
    • Exported Energy Mj By Energy Vector Installation A5 : 0
    • Exported Energy Mj By Energy Vector Maintenance B2 : 0
    • Exported Energy Mj By Energy Vector Repair B3 : 0
    • Exported Energy Mj By Energy Vector Replacement B4 : 0
    • Exported Energy Mj By Energy Vector Operational Energy Use B6 : 0
    • Exported Energy Mj By Energy Vector End Of Life C1 C4 : 0
    • Exported Energy Mj By Energy Vector Benefits Loads Beyond System Boundaries D : 0
    • Freshwater Eutrophication Kg P Eq Total Life Cycle : 0.00017351652010770462
    • Freshwater Eutrophication Kg P Eq Manufacturing A1 A3 : 0.00015479998376930891
    • Freshwater Eutrophication Kg P Eq Distribution A4 : 0.00000169932750336347
    • Freshwater Eutrophication Kg P Eq Installation A5 : 0.00000011102480818978
    • Freshwater Eutrophication Kg P Eq Maintenance B2 : 0
    • Freshwater Eutrophication Kg P Eq Repair B3 : 0
    • Freshwater Eutrophication Kg P Eq Replacement B4 : 0
    • Freshwater Eutrophication Kg P Eq Operational Energy Use B6 : 0.00000235453766871397
    • Freshwater Eutrophication Kg P Eq End Of Life C1 C4 : 0.0000145516463581285
    • Freshwater Eutrophication Kg P Eq Benefits Loads Beyond System Boundaries D : -0.00000128531375010049
    • Hazardous Waste Disposed Of Kg Total Life Cycle : 57.921288317486194
    • Hazardous Waste Disposed Of Kg Manufacturing A1 A3 : 57.811442934681814
    • Hazardous Waste Disposed Of Kg Distribution A4 : 0.0023132157054722526
    • Hazardous Waste Disposed Of Kg Installation A5 : 0.10221271301342838
    • Hazardous Waste Disposed Of Kg Maintenance B2 : 0
    • Hazardous Waste Disposed Of Kg Repair B3 : 0
    • Hazardous Waste Disposed Of Kg Replacement B4 : 0
    • Hazardous Waste Disposed Of Kg Operational Energy Use B6 : 0
    • Hazardous Waste Disposed Of Kg End Of Life C1 C4 : 0.005319454085477713
    • Hazardous Waste Disposed Of Kg Benefits Loads Beyond System Boundaries D : -37.04375027629199
    • Human Toxicity Carcinogenic Effects Ctuh Total Life Cycle : 0.00000102728068731678
    • Human Toxicity Carcinogenic Effects Ctuh Manufacturing A1 A3 : 0.0000010263933229415
    • Human Toxicity Carcinogenic Effects Ctuh Distribution A4 : 0.00000000010881106266
    • Human Toxicity Carcinogenic Effects Ctuh Installation A5 : 0.00000000001690488127
    • Human Toxicity Carcinogenic Effects Ctuh Maintenance B2 : 0
    • Human Toxicity Carcinogenic Effects Ctuh Repair B3 : 0
    • Human Toxicity Carcinogenic Effects Ctuh Replacement B4 : 0
    • Human Toxicity Carcinogenic Effects Ctuh Operational Energy Use B6 : 0.00000000016274037341
    • Human Toxicity Carcinogenic Effects Ctuh End Of Life C1 C4 : 0.00000000059890805794
    • Human Toxicity Carcinogenic Effects Ctuh Benefits Loads Beyond System Boundaries D : -0.00000258857964554495
    • Human Toxicity Non Carcinogenic Effects Ctuh Total Life Cycle : 0.00000100585492655252
    • Human Toxicity Non Carcinogenic Effects Ctuh Manufacturing A1 A3 : 0.00000099395629569759
    • Human Toxicity Non Carcinogenic Effects Ctuh Distribution A4 : 0.00000000215782213944
    • Human Toxicity Non Carcinogenic Effects Ctuh Installation A5 : 0.00000000068403868489
    • Human Toxicity Non Carcinogenic Effects Ctuh Maintenance B2 : 0
    • Human Toxicity Non Carcinogenic Effects Ctuh Repair B3 : 0
    • Human Toxicity Non Carcinogenic Effects Ctuh Replacement B4 : 0
    • Human Toxicity Non Carcinogenic Effects Ctuh Operational Energy Use B6 : 0.00000000387897224473
    • Human Toxicity Non Carcinogenic Effects Ctuh End Of Life C1 C4 : 0.00000000517779778587
    • Human Toxicity Non Carcinogenic Effects Ctuh Benefits Loads Beyond System Boundaries D : -0.00000037726454210562
    • Impacts Related To Land Use Soil Quality Total Life Cycle : 0.10429231288699879
    • Impacts Related To Land Use Soil Quality Manufacturing A1 A3 : 0.06331899721555426
    • Impacts Related To Land Use Soil Quality Distribution A4 : 0.002371593766478442
    • Impacts Related To Land Use Soil Quality Installation A5 : 0.0020179674084379747
    • Impacts Related To Land Use Soil Quality Maintenance B2 : 0
    • Impacts Related To Land Use Soil Quality Repair B3 : 0
    • Impacts Related To Land Use Soil Quality Replacement B4 : 0
    • Impacts Related To Land Use Soil Quality Operational Energy Use B6 : 0.02954427476091118
    • Impacts Related To Land Use Soil Quality End Of Life C1 C4 : 0.007039479735616944
    • Impacts Related To Land Use Soil Quality Benefits Loads Beyond System Boundaries D : 0
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Total Life Cycle : 6.439971854861489
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Manufacturing A1 A3 : 4.975276621456796
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Distribution A4 : 0.019250864462530583
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Installation A5 : 0.03448704946729271
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Maintenance B2 : 0
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Repair B3 : 0
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Replacement B4 : 0
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Operational Energy Use B6 : 1.285122854323384
    • Ionizing Radiation Human Health Kbq Of U235 Equiv End Of Life C1 C4 : 0.1258344651514853
    • Ionizing Radiation Human Health Kbq Of U235 Equiv BLB SysBound D : -0.5692921275908001
    • Marine Aquatic Eutrophication Kg Of N Equiv Total Life Cycle : 0.009474797352126071
    • Marine Aquatic Eutrophication Kg Of N Equiv Manufacturing A1 A3 : 0.007278205951991405
    • Marine Aquatic Eutrophication Kg Of N Equiv Distribution A4 : 0.00014406444370455314
    • Marine Aquatic Eutrophication Kg Of N Equiv Installation A5 : 0.000142808432861343
    • Marine Aquatic Eutrophication Kg Of N Equiv Maintenance B2 : 0
    • Marine Aquatic Eutrophication Kg Of N Equiv Repair B3 : 0
    • Marine Aquatic Eutrophication Kg Of N Equiv Replacement B4 : 0
    • Marine Aquatic Eutrophication Kg Of N Equiv Operational Energy Use B6 : 0.0007783999915329658
    • Marine Aquatic Eutrophication Kg Of N Equiv End Of Life C1 C4 : 0.001131318532035806
    • Marine Aquatic Eutrophication Kg Of N Equiv Benefits Loads Beyond System Boundaries D : -0.0007449211653390952
    • Materials For Energy Recovery Kg Total Life Cycle : 0
    • Materials For Energy Recovery Kg Manufacturing A1 A3 : 0
    • Materials For Energy Recovery Kg Distribution A4 : 0
    • Materials For Energy Recovery Kg Installation A5 : 0
    • Materials For Energy Recovery Kg Maintenance B2 : 0
    • Materials For Energy Recovery Kg Repair B3 : 0
    • Materials For Energy Recovery Kg Replacement B4 : 0
    • Materials For Energy Recovery Kg Operational Energy Use B6 : 0
    • Materials For Energy Recovery Kg End Of Life C1 C4 : 0
    • Materials For Energy Recovery Kg Benefits Loads Beyond System Boundaries D : 0
    • Materials For Recycling Kg Total Life Cycle : 0.41172943875528495
    • Materials For Recycling Kg Manufacturing A1 A3 : 0.06325073413459266
    • Materials For Recycling Kg Distribution A4 : 0
    • Materials For Recycling Kg Installation A5 : 0
    • Materials For Recycling Kg Maintenance B2 : 0
    • Materials For Recycling Kg Repair B3 : 0
    • Materials For Recycling Kg Replacement B4 : 0
    • Materials For Recycling Kg Operational Energy Use B6 : 0
    • Materials For Recycling Kg End Of Life C1 C4 : 0.3484787046206923
    • Materials For Recycling Kg Benefits Loads Beyond System Boundaries D : 0
    • Net Use Of Fresh Water M3 Total Life Cycle : 0.08826690567055703
    • Net Use Of Fresh Water M3 Manufacturing A1 A3 : 0.08079630439966429
    • Net Use Of Fresh Water M3 Distribution A4 : 0.00043480248310414575
    • Net Use Of Fresh Water M3 Installation A5 : 0.00012372279014449098
    • Net Use Of Fresh Water M3 Maintenance B2 : 0
    • Net Use Of Fresh Water M3 Repair B3 : 0
    • Net Use Of Fresh Water M3 Replacement B4 : 0
    • Net Use Of Fresh Water M3 Operational Energy Use B6 : 0.001930015213521714
    • Net Use Of Fresh Water M3 End Of Life C1 C4 : 0.004982060784122399
    • Net Use Of Fresh Water M3 Benefits Loads Beyond System Boundaries D : -0.03500607422917794
    • Non Hazardous Waste Disposed Of Kg Total Life Cycle : 4.2646509847996406
    • Non Hazardous Waste Disposed Of Kg Manufacturing A1 A3 : 2.766110649592913
    • Non Hazardous Waste Disposed Of Kg Distribution A4 : 0.051440080384284693
    • Non Hazardous Waste Disposed Of Kg Installation A5 : 0.0123996655010424
    • Non Hazardous Waste Disposed Of Kg Maintenance B2 : 0
    • Non Hazardous Waste Disposed Of Kg Repair B3 : 0
    • Non Hazardous Waste Disposed Of Kg Replacement B4 : 0
    • Non Hazardous Waste Disposed Of Kg Operational Energy Use B6 : 0.2264199705763508
    • Non Hazardous Waste Disposed Of Kg End Of Life C1 C4 : 1.2082806187450492
    • Non Hazardous Waste Disposed Of Kg Benefits Loads Beyond System Boundaries D : -0.609770739442399
    • Ozone Depletion Kg Equivalent Cfc 11 Total Life Cycle : 0.00000066257463371228
    • Ozone Depletion Kg Equivalent Cfc 11 Manufacturing A1 A3 : 0.00000062925093476546
    • Ozone Depletion Kg Equivalent Cfc 11 Distribution A4 : 0.00000000646044209607
    • Ozone Depletion Kg Equivalent Cfc 11 Installation A5 : 0.00000000337375834713
    • Ozone Depletion Kg Equivalent Cfc 11 Maintenance B2 : 0
    • Ozone Depletion Kg Equivalent Cfc 11 Repair B3 : 0
    • Ozone Depletion Kg Equivalent Cfc 11 Replacement B4 : 0
    • Ozone Depletion Kg Equivalent Cfc 11 Operational Energy Use B6 : 0.00000000503126979835
    • Ozone Depletion Kg Equivalent Cfc 11 End Of Life C1 C4 : 0.00000001845822870528
    • Ozone Depletion Kg Equivalent Cfc 11 Benefits Loads Beyond System Boundaries D : -0.00000020153177760776
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Total Life Cycle : 0.03262162789802851
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Manufacturing A1 A3 : 0.02586391260101409
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Distribution A4 : 0.0005098235773431821
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Installation A5 : 0.00040053378026452075
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Maintenance B2 : 0
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Repair B3 : 0
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Replacement B4 : 0
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Operational Energy Use B6 : 0.002566780778983087
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv End Of Life C1 C4 : 0.0032805771604236303
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Benefits Loads Beyond System Boundaries D : -0.004359940406809303
    • Radioactive Waste Disposed Of Kg Total Life Cycle : 0.0010638213397856178
    • Radioactive Waste Disposed Of Kg Manufacturing A1 A3 : 0.0009257052656878324
    • Radioactive Waste Disposed Of Kg Distribution A4 : 0.00004072581449748044
    • Radioactive Waste Disposed Of Kg Installation A5 : 0.00000517252602537931
    • Radioactive Waste Disposed Of Kg Maintenance B2 : 0
    • Radioactive Waste Disposed Of Kg Repair B3 : 0
    • Radioactive Waste Disposed Of Kg Replacement B4 : 0
    • Radioactive Waste Disposed Of Kg Operational Energy Use B6 : 0.00005259789789466586
    • Radioactive Waste Disposed Of Kg End Of Life C1 C4 : 0.00003961983568025981
    • Radioactive Waste Disposed Of Kg Benefits Loads Beyond System Boundaries D : -0.00028844478237539256
    • Terrestrial Eutrophication Mole Of N Equiv Total Life Cycle : 0.0960112877810369
    • Terrestrial Eutrophication Mole Of N Equiv Manufacturing A1 A3 : 0.0704121255329049
    • Terrestrial Eutrophication Mole Of N Equiv Distribution A4 : 0.0015808093176336794
    • Terrestrial Eutrophication Mole Of N Equiv Installation A5 : 0.0018798247500074468
    • Terrestrial Eutrophication Mole Of N Equiv Maintenance B2 : 0
    • Terrestrial Eutrophication Mole Of N Equiv Repair B3 : 0
    • Terrestrial Eutrophication Mole Of N Equiv Replacement B4 : 0
    • Terrestrial Eutrophication Mole Of N Equiv Operational Energy Use B6 : 0.009328698525549019
    • Terrestrial Eutrophication Mole Of N Equiv End Of Life C1 C4 : 0.012809829654941842
    • Terrestrial Eutrophication Mole Of N Equiv Benefits Loads Beyond System Boundaries D : -0.00875268445478728
    • Total Use Of NRE PrE Resources And PrE Resources Used As RawMats Mj TLC : 25.599058894428754
    • Total Use Of NRE PrE Resources And PrE Resources Used As RawMats Mj Mfg A1 A3 : 25.599058894428754
    • Total Use Of NRE PrE Resources And PrE Resources Used As RawMats Mj Dist A4 : 0
    • Total Use Of NRE PrE Resources And PrE Resources Used As RawMats Mj Inst A5 : 0
    • Total Use Of NRE PrE Resources And PrE Resources Used As RawMats Mj Maint B2 : 0
    • Total Use Of NRE PrE Resources And PrE Resources Used As RawMats Mj Repair B3 : 0
    • Total Use Of NRE PrE Resources And PrE Resources Used As RawMats Mj Replament B4 : 0
    • Total Use Of NRE PrE Resources And PrE Resources Used As RawMats Mj OpEnergy B6 : 0
    • Total Use Of NRE PrE Resources And PrE Resources Used As RawMats Mj EoL C1 C4 : 0
    • Total Use Of NRE PrE Resources And PrE Resources Used As RawMats Mj BLB SysBound D : 0
    • Total Use Of Primary Energy During The Life Cycle Mj Total Life Cycle : 262.02710313369823
    • Total Use Of Primary Energy During The Life Cycle Mj Manufacturing A1 A3 : 204.7633770326581
    • Total Use Of Primary Energy During The Life Cycle Mj Distribution A4 : 8.215642740610066
    • Total Use Of Primary Energy During The Life Cycle Mj Installation A5 : 1.8894510991920301
    • Total Use Of Primary Energy During The Life Cycle Mj Maintenance B2 : 0
    • Total Use Of Primary Energy During The Life Cycle Mj Repair B3 : 0
    • Total Use Of Primary Energy During The Life Cycle Mj Replacement B4 : 0
    • Total Use Of Primary Energy During The Life Cycle Mj Operational Energy Use B6 : 36.05389361413643
    • Total Use Of Primary Energy During The Life Cycle Mj End Of Life C1 C4 : 11.10473864710164
    • Total Use Of PrE During The Life Cycle Mj BLB SysBound D : -22.04122360847295
    • Total Use Of RE PrE Resources And PrE Resources Used As RawMats Mj TLC : 16.086113276338278
    • Total Use Of RE PrE Resources And PrE Resources Used As RawMats Mj Mfg A1 A3 : 9.734434575246892
    • Total Use Of RE PrE Resources And PrE Resources Used As RawMats Mj Dist A4 : 0.03103705511275958
    • Total Use Of RE PrE Resources And PrE Resources Used As RawMats Mj Inst A5 : 0.14961234717107383
    • Total Use Of RE PrE Resources And PrE Resources Used As RawMats Mj Maint B2 : 0
    • Total Use Of RE PrE Resources And PrE Resources Used As RawMats Mj Repair B3 : 0
    • Total Use Of RE PrE Resources And PrE Resources Used As RawMats Mj Replament B4 : 0
    • Total Use Of RE PrE Resources And PrE Resources Used As RawMats Mj OpEnergy B6 : 5.640019178487326
    • Total Use Of RE PrE Resources And PrE Resources Used As RawMats Mj EoL C1 C4 : 0.531010120320225
    • Total Use Of RE PrE Resources And PrE Resources Used As RawMats Mj BLB SysBound D : -0.4372862578533509
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 25.599058894428754
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 25.599058894428754
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Maintenance B2 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Repair B3 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Replacement B4 : 0
    • Use Of NRE PrE Resources Used As RawMats Mj OpEnergy B6 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 0
    • Use Of NRE PrE Resources Used As RawMats Mj BLB SysBound D : 0
    • Use Of NRE PrE Excluding NRE PrE Resources Used As RawMats Mj TLC : 220.34193096293123
    • Use Of NRE PrE Excluding NRE PrE Resources Used As RawMats Mj Mfg A1 A3 : 169.42988356298247
    • Use Of NRE PrE Excluding NRE PrE Resources Used As RawMats Mj Dist A4 : 8.184605685497305
    • Use Of NRE PrE Excluding NRE PrE Resources Used As RawMats Mj Inst A5 : 1.7398387520209562
    • Use Of NRE PrE Excluding NRE PrE Resources Used As RawMats Mj Maint B2 : 0
    • Use Of NRE PrE Excluding NRE PrE Resources Used As RawMats Mj Repair B3 : 0
    • Use Of NRE PrE Excluding NRE PrE Resources Used As RawMats Mj Replacement B4 : 0
    • Use Of NRE PrE Excluding NRE PrE Resources Used As RawMats Mj OpEnergy B6 : 30.4138744356491
    • Use Of NRE PrE Excluding NRE PrE Resources Used As RawMats Mj EoL C1 C4 : 10.573728526781414
    • Use Of NRE PrE Excluding NRE PrE Resources Used As RawMats Mj BLB SysBound D : -21.603937350619596
    • Use Of Non Renewable Secondary Fuels Mj Total Life Cycle : 0
    • Use Of Non Renewable Secondary Fuels Mj Manufacturing A1 A3 : 0
    • Use Of Non Renewable Secondary Fuels Mj Distribution A4 : 0
    • Use Of Non Renewable Secondary Fuels Mj Installation A5 : 0
    • Use Of Non Renewable Secondary Fuels Mj Maintenance B2 : 0
    • Use Of Non Renewable Secondary Fuels Mj Repair B3 : 0
    • Use Of Non Renewable Secondary Fuels Mj Replacement B4 : 0
    • Use Of Non Renewable Secondary Fuels Mj Operational Energy Use B6 : 0
    • Use Of Non Renewable Secondary Fuels Mj End Of Life C1 C4 : 0
    • Use Of Non Renewable Secondary Fuels Mj Benefits Loads Beyond System Boundaries D : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 2.4242864876638657
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 2.4242864876638657
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Maintenance B2 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Repair B3 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Replacement B4 : 0
    • Use Of RE PrE Resources Used As RawMats Mj OpEnergy B6 : 0
    • Use Of RE PrE Resources Used As RawMats Mj BLB SysBound D : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Benefits Loads Beyond System Boundaries D : 0.3364033613445378
    • Use Of RE PrE Excluding RE PrE Resources Used As RawMats Mj TLC : 13.66182678867441
    • Use Of RE PrE Excluding RE PrE Resources Used As RawMats Mj Mfg A1 A3 : 7.310148087583027
    • Use Of RE PrE Excluding RE PrE Resources Used As RawMats Mj Dist A4 : 0.03103705511275958
    • Use Of RE PrE Excluding RE PrE Resources Used As RawMats Mj Inst A5 : 0.14961234717107383
    • Use Of RE PrE Excluding RE PrE Resources Used As RawMats Mj Maint B2 : 0
    • Use Of RE PrE Excluding RE PrE Resources Used As RawMats Mj Repair B3 : 0
    • Use Of RE PrE Excluding RE PrE Resources Used As RawMats Mj Replacement B4 : 0
    • Use Of RE PrE Excluding RE PrE Resources Used As RawMats Mj OpEnergy B6 : 5.640019178487326
    • Use Of RE PrE Excluding RE PrE Resources Used As RawMats Mj EoL C1 C4 : 0.531010120320225
    • Use Of RE PrE Excluding RE PrE Resources Used As RawMats Mj BLB SysBound D : -0.7736896191978888
    • Use Of Renewable Secondary Fuels Mj Total Life Cycle : 0
    • Use Of Renewable Secondary Fuels Mj Manufacturing A1 A3 : 0
    • Use Of Renewable Secondary Fuels Mj Distribution A4 : 0
    • Use Of Renewable Secondary Fuels Mj Installation A5 : 0
    • Use Of Renewable Secondary Fuels Mj Maintenance B2 : 0
    • Use Of Renewable Secondary Fuels Mj Repair B3 : 0
    • Use Of Renewable Secondary Fuels Mj Replacement B4 : 0
    • Use Of Renewable Secondary Fuels Mj Operational Energy Use B6 : 0
    • Use Of Renewable Secondary Fuels Mj End Of Life C1 C4 : 0
    • Use Of Renewable Secondary Fuels Mj Benefits Loads Beyond System Boundaries D : 0
    • Use Of Secondary Materials Kg Total Life Cycle : 0.16877423218487397
    • Use Of Secondary Materials Kg Manufacturing A1 A3 : 0.16877423218487397
    • Use Of Secondary Materials Kg Distribution A4 : 0
    • Use Of Secondary Materials Kg Installation A5 : 0
    • Use Of Secondary Materials Kg Maintenance B2 : 0
    • Use Of Secondary Materials Kg Repair B3 : 0
    • Use Of Secondary Materials Kg Replacement B4 : 0
    • Use Of Secondary Materials Kg Operational Energy Use B6 : 0
    • Use Of Secondary Materials Kg End Of Life C1 C4 : 0
    • Use Of Secondary Materials Kg Benefits Loads Beyond System Boundaries D : 0
    • Water Use M3 Eq Total Life Cycle : 3.766588119878005
    • Water Use M3 Eq Manufacturing A1 A3 : 3.4701821299378053
    • Water Use M3 Eq Distribution A4 : 0.01867397199160291
    • Water Use M3 Eq Installation A5 : 0.005407462093624865
    • Water Use M3 Eq Maintenance B2 : 0
    • Water Use M3 Eq Repair B3 : 0
    • Water Use M3 Eq Replacement B4 : 0
    • Water Use M3 Eq Operational Energy Use B6 : 0.08282997970823561
    • Water Use M3 Eq End Of Life C1 C4 : 0.18949457614673604
    • Water Use M3 Eq Benefits Loads Beyond System Boundaries D : -1.5034826892084017
    • Air Pollution M3 Total Life Cycle : 0
    • Air Pollution M3 Manufacturing A1 A3 : 0
    • Air Pollution M3 Distribution A4 : 0
    • Air Pollution M3 Installation A5 : 0
    • Air Pollution M3 Maintenance B2 : 0
    • Air Pollution M3 Repair B3 : 0
    • Air Pollution M3 Replacement B4 : 0
    • Air Pollution M3 Operational Energy Use B6 : 0
    • Air Pollution M3 End Of Life C1 C4 : 0
    • Air Pollution M3 Benefits Loads Beyond System Boundaries D : 0
    • Water Pollution M3 Total Life Cycle : 0
    • Water Pollution M3 Manufacturing A1 A3 : 0
    • Water Pollution M3 Distribution A4 : 0
    • Water Pollution M3 Installation A5 : 0
    • Water Pollution M3 Maintenance B2 : 0
    • Water Pollution M3 Repair B3 : 0
    • Water Pollution M3 Replacement B4 : 0
    • Water Pollution M3 Operational Energy Use B6 : 0
    • Water Pollution M3 End Of Life C1 C4 : 0
    • Water Pollution M3 Benefits Loads Beyond System Boundaries D : 0
  • Important Information Attributes
    • Persona Type Ids : LC, OM
    • Persona Type Names : Contractor, Original Equipment Manufacturer
    • AWG Gauge : AWG 12...AWG 2/0 aluminium, AWG 12...AWG 2/0 aluminium, AWG 14...AWG 2/0 copper, AWG 14...AWG 2/0 copper
    • Electrical Connection : lugs aluminium, lugs aluminium
    • Product Destination : NF panelboard, NF panelboard
    • Tightening Torque : 3.9-3.9 N.m 2.5-6 mm² (AWG 14...AWG 10), 3.9-3.9 N.m 2.5-6 mm² (AWG 14...AWG 10), 3.9-3.9 N.m 2.5-6 mm² (AWG 14...AWG 10), 5.6-5.6 N.m 10-70 mm² (AWG 8...AWG 2/0), 5.6-5.6 N.m 10-70 mm² (AWG 8...AWG 2/0), 5.6-5.6 N.m 10-70 mm² (AWG 8...AWG 2/0)
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-11-19
    • Device Type : LV equipment - Low voltage circuit breaker
    • Serviceability : No
    • Traceability : Yes
    • Field Service Division : PPIBS
    • Average Life Duration : 15 year(s)
    • Legacy WEEE Scope : Out
    • Scope Perimeter : Outside of Europe
    • EOLI Availability Display : No need of specific recycling operations
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • ROHS EUR In Scope : No
    • ROHS EUR Status : Compliant with Exemptions
    • ROHS EUR Full Compliance Status : Pro-active compliance (Product out of EU RoHS legal scope)
    • ROHS EUR Full Compliance Status Id : PRO_ACTIVE_COMPLIANCE
    • China ROHS In Scope : No
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : No
    • Product Contributes To Saved And Avoided Emissions : No
    • Return Indicator : N
    • WD Status : 5 - INITIALIZED WITH DataSCAN OK (Migration)
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Market Segmentation Id : COMMERCIAL
    • Market Segmentation : Commercial
    • H And D Domain : Safety
    • H And D Subrange : COM
    • H And D Enrichment Assignment : no
    • H And D Enrichment Function : MCB
    • H And D Enrichment Class 3 : Circuit Breakers
    • H And D Enrichment Class 4 : MCB UL 2P
    • Device Short Name : EGB
    • Energy Efficiency Optimized : False
    • Holding Current : 630 A
    • Module Type : E-Frame
    • Package Weight Lbs : 1.39 kg
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Or Component Type : miniature circuit-breaker
    • Range Of Product : 125 A Frame EDB-EGB-EJB
    • Returnability : No
    • Sustainable Packaging : No
    • Total Lifecycle Carbon Footprint : 15 kg CO2 eq.
    • Relationship Type : Compatible relationship
    • Pep Code : ENVPEP2510013EN
    • Pep Verification Date : 2025-11-01
    • PCR Version : PEP-PCR-ed4-2021 09 06
    • PSR Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent internal review
    • Functional Unit Description : Protect the installation from overloads and short circuits in a circuit with rated voltage Ue, rated current In, with Np poles, a rated breaking capacity Icn, and the tripping curve Cd if applicable, and, if applicable, the specific specifications, in the Household/Commercial application area, according to the appropriate use scenario, and during the reference service life of the product of 20 years.
    • Functional Unit Unit : unit
    • Product Kit Identifier : N
    • Huella De Carbono De La Fase De Distribución A4 : 0.4 kg CO2 eq.
    • Huella De Carbono De La Fase De Fabricación A1 A A3 : 10 kg CO2 eq.
    • Huella De Carbono De La Fase De Fin De Vida C1 A C4 : 2 kg CO2 eq.
    • Huella De Carbono De La Fase De Instalación A5 : 0.5 kg CO2 eq.
    • Huella De Carbono De La Fase De Uso B2 B3 B4 B6 : 1 kg CO2 eq.
  • Environment Attributes Main
    • EU ROHS Directive : Compliant By Exemption​, Pro-active compliance (Product out of EU RoHS legal scope)
    • ROHS Exemption Information : Yes
    • Take Back : No
    • Recycled Metal Content At Cr Level : 0 %
    • China ROHS Regulation : Product out of China RoHS scope. Substance declaration for your information.
    • Mercury Free : Yes
    • Carbon Footprint : 14.501418077493437
    • Environmental Disclosure : ENVPEP2510013EN
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : No
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP2510013EN
    • Pep Verification Date : 2025-11-01
    • PCR Version : PEP-PCR-ed4-2021 09 06
    • PSR Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Product Or Component Type : miniature circuit-breaker
    • Range Of Product : 125 A Frame EDB-EGB-EJB
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Specifications
    • Compliance : TAA