Unit substation, Mini Power-Zone, plug on, 15kVA, 3 phase, 480V primary, 208Y/120V secondary, 18kA, C

MINI POWER ZONE

SQDMPU15T2F MPU15T2F 785901728139
13636.44 / EA
http://schema.org/OutOfStock
  • Depth: 342.9 mm
  • Material: Copper
  • Primary Voltage: 480 V
  • Temperature Rise: 115 °C
  • Warranty Length: 18 mth
Square D™ brand Mini Power-Zone™ unit substation from Schneider Electric provides the answer to requirements for a portable, compact power supply for small loads. It features a separate transformer and panel section, allowing for flexible installation. This allows the panel section to be removed and wired first if desired. These transformers can be replaced without disturbing the panel section and associated wiring. The new transformer simply slides into the top of the panel section and primary and secondary leads are reconnected to the main circuit breakers. Provides a wide range of breaking capacity between 18 to 65 kA at 480 Vac. This Mini Power-Zone Sealed Transformer is a 3 phase, with a primary voltage of 480V and a secondary voltage of 208Y/120V with bolt on breakers. This transformer has a temperature rise of 115 °C and a insulation temperature rating of 185 °C. These transformers are installed on the interior of the load center that has 27 spaces. With a rated power of 15kVA, it has a short circuit current of 18kA. The enclosure material is hot-rolled steel and is rated at NEMA 3R. This transformer complies to UL listed standards.
QTY
  • Product Description
  • Features
  • Specifications
Square D™ brand Mini Power-Zone™ unit substation from Schneider Electric provides the answer to requirements for a portable, compact power supply for small loads. It features a separate transformer and panel section, allowing for flexible installation. This allows the panel section to be removed and wired first if desired. These transformers can be replaced without disturbing the panel section and associated wiring. The new transformer simply slides into the top of the panel section and primary and secondary leads are reconnected to the main circuit breakers. Provides a wide range of breaking capacity between 18 to 65 kA at 480 Vac. This Mini Power-Zone Sealed Transformer is a 3 phase, with a primary voltage of 480V and a secondary voltage of 208Y/120V with bolt on breakers. This transformer has a temperature rise of 115 °C and a insulation temperature rating of 185 °C. These transformers are installed on the interior of the load center that has 27 spaces. With a rated power of 15kVA, it has a short circuit current of 18kA. The enclosure material is hot-rolled steel and is rated at NEMA 3R. This transformer complies to UL listed standards.
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Nickel (Metallic), which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Conformance Attributes
    • Product Certifications : UL Listed
  • Complementary Attributes
    • Rated Power In Va : 15 kVA
  • Important Information Attributes
    • Circuit Breaker Application : feeder breaker, primary main breaker, secondary main breaker
    • Medium Desc : Unit substation, Mini Power-Zone, plug on, 15kVA, 3 phase, 480V primary, 208Y/120V secondary, 18kA, C
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-11-18
    • Global Commercial Status : Commercialised
    • Return Indicator : Y
    • Stocking Flag : Y
    • Device Type : Transformer - dry
    • Serviceability : No
    • Traceability : Yes
    • Field Service Division : PSIBS
    • Average Life Duration : 25 year(s)
    • Legacy Weee Scope : In
    • Scope Perimeter : Outside of Europe
    • Reach Full Compliance Status : Free of Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : NOT_CONTAINING_SVHC
    • Reach Compliance Directive : Free of Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : Yes
    • Rohs Eur Status : Compliant By Exemption
    • Rohs Eur Full Compliance Status : Compliant By Exemption
    • China Rohs In Scope : No
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : No
    • Product Contributes To Saved And Avoided Emissions : No
    • Product Kit Identifier : N
    • Board Name : QO Load Center interior
    • Box Number : C
    • Insulation Temperature : 185 °C
    • Material : copper
    • Number Of Tap Offs : 2 5 % FCBN
    • Phase : 3 phase
    • Primary Voltage : 480 V
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Or Component Type : Sealed Transformer
    • Range Of Product : Mini Power-Zone
    • Returnability : Yes
    • Secondary Voltage : 208Y/120 V
    • Short Circuit Current : 18 kA
    • Sustainable Packaging : No
    • Temperature Rise : 115 °C
    • Height Nominal : 1148.08 mm
    • Width Nominal : 695.96 mm
  • Environment Attributes Main
    • China Rohs Regulation : Product out of China RoHS scope , Product out of China RoHS scope. Substance declaration for your information.
    • Take Back : No
    • Reach Free Shvc : Yes
    • Recycled Metal Content At Cr Level : 0 %
    • Mercury Free : Yes
    • Eu Rohs Directive : Compliant By Exemption
    • Nema Degree Of Protection : NEMA 3R hot-rolled steel
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : No
    • Reach Free Of Svhc : Yes
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
  • General Attributes
    • Phase : 3 phase
    • Product Or Component Type : Sealed Transformer
    • Range Of Product : Mini Power-Zone
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Specifications
    • Depth : 342.9 mm