SQUARE D

Meter mains, QO, CSED, ringless socket, 200A, surface mount, no bypass

METER MAIN RINGLESS T-SURFACE

SQDRC2M200S RC2M200S 785901396697
1076.43 / EACH
http://schema.org/OutOfStock
  • Depth: 4.60 in
  • Height: 18.23 in
  • Number of Circuits: 0
  • Number of Spaces: 0
  • Short Circuit Current Rating: 22 kA
  • Warranty Length: 18 mth
  • Width: 19.58 in
QO All In One combination service entrance devices are available with ring or ringless type meter socket designs. Devices have factory installed service disconnect(s) in most cases. Supplied with 100% branch neutrals, all unused terminals may be used for equipment grounding wires. These Homeline combination service entrance devices meet the Federal Specification W P 115c as Type 1, Class 2 specifications. This QO All In One combination service entrance device has a ringless meter socket with no bypass. This unit can be feed from an overhead or underground service. The service disconnect, which must be ordered separately, is a QOM2 VH (200 A maximum) and a QO VH (50 A maximum). Device has a 22 kA short circuit current rating. Load center has no spaces. This unit has a NEMA 3R surface mounting enclosure that is 18.23 inches tall, 19.58 inches wide and 4.60 inches deep. The line side lugs will accept 6 AWG to 350 kcmil copper or aluminum wire. The service ground lug will accept up to two 8 AWG to 2/0 AWG copper or aluminum wire. This QO combination service entrance device is UL Listed. Device meets EUSERC standards.
QTY
  • Product Description
  • Features
  • Specifications
QO All In One combination service entrance devices are available with ring or ringless type meter socket designs. Devices have factory installed service disconnect(s) in most cases. Supplied with 100% branch neutrals, all unused terminals may be used for equipment grounding wires. These Homeline combination service entrance devices meet the Federal Specification W P 115c as Type 1, Class 2 specifications. This QO All In One combination service entrance device has a ringless meter socket with no bypass. This unit can be feed from an overhead or underground service. The service disconnect, which must be ordered separately, is a QOM2 VH (200 A maximum) and a QO VH (50 A maximum). Device has a 22 kA short circuit current rating. Load center has no spaces. This unit has a NEMA 3R surface mounting enclosure that is 18.23 inches tall, 19.58 inches wide and 4.60 inches deep. The line side lugs will accept 6 AWG to 350 kcmil copper or aluminum wire. The service ground lug will accept up to two 8 AWG to 2/0 AWG copper or aluminum wire. This QO combination service entrance device is UL Listed. Device meets EUSERC standards.
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Environment
    • Product Certifications : UL E-6294
  • Contractual warranty
    • Warranty : 18 months
  • Environmental data
    • Rohs Exemption Information : Yes
    • Packaging Made With Recycled Cardboard : No
    • Mercury Free : Yes
    • Environmental Disclosure : ENVPEP1407020EN
    • Packaging Without Single Use Plastic : Yes
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
    • Reach Free Of Svhc : Yes
    • Circularity Profile : N/A
    • Take-Back : No
    • Eu Rohs Directive : Compliant with Exemptions
  • Complementary
    • Height : 18.23 in
    • Tightening Torque : lugs 250 lb.in, AWG 6...350 kcmil, aluminium/copper || lugs 250 lb.in, AWG 4...250 kcmil, aluminium/copper || service ground 50 lb.in, AWG 3...AWG 2/0, aluminium/copper || service ground 45 lb.in, AWG 6...AWG 4, aluminium/copper || service ground 40 lb.in, AWG 8, copper || lugs 50 lb.in, AWG 3...AWG 2/0, aluminium/copper || lugs 45 lb.in, AWG 6...AWG 4, aluminium/copper || lugs 40 lb.in, AWG 8, copper || Cover 10 lb.in
    • Bypass Type : no bypass
    • Service Feed Location : OH || UG
    • Electrical Connection : lugs, line side || lugs, service ground
    • Number Of Circuits : 0
    • Number Of Spaces : 0
    • Short-Circuit Current : 22 kA
    • Number Of Tandem Circuit Breakers : 0
    • Hub Type : A
    • Meter Socket Type : ringless
    • Service Disconnect Rated Current : 200 A
    • Line Rated Current : 200 A
    • Awg Gauge : AWG 6...300 kcmil aluminium/copper)line side || AWG 8...AWG 2/0 2 aluminium/copper)service ground
    • Width : 19.58 in
    • Depth : 4.60 in
    • Network Number Of Phases : 1
    • Device Composition : service disconnect (ordered separately)
    • Device Mounting : surface
  • Specifications
    • Country of Origin : Mexico
    • Width : 19.58 in
    • Height : 18.23 in
    • Range Of Product : QO
    • Product Or Component Type : Meter Mains